a macab power point presentation rian bv waalre 040-2213656 cable –rian – access system

24
a macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

Upload: raven-sugar

Post on 01-Apr-2015

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

CABLE –RIAN – Access System

Page 2: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Multilet access system MAS-64

• Access switch, CMTS, for up to 64 users.

• Extra outlet for every connected user.

• Not connected users are not affected

• Frequency 5 – 36 MHz for upstream

• Frequency 64 – 76 MHz for downstream

• Use existing coax installation, no upgrade to network required.

• Build VLAN between users

• Range up to 5 km between MAS and MIO

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 3: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

MAS 64

• Build in Bridge and Switch/Router with DHCP and NAT.

• Windows XP embedded

• Small installation size

• 10/100 Base-T for the WAN port (RJ-45)

• 10/100 Base-T for the Management port (RJ-45)

• F-female for RF-connection

• Automatic registration and provisioning

• Home-network VLAN supported

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 4: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Multilet intelligent outlet MIO-04

• Data interface 10/100 Base-T with RJ45 connector

• Plug ´n Play

• Easy to install

• Management per outlet

• Possible to turn of outlet from MAS

• Small size

• Need powersupply

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 5: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Connecting the MAS to the Cable system

-1dB

8 dB TAP

OUT IN

Output level from MAS:Max 108 dBuV

Min Input level to MAS from Mio: 63 dBuV

TV-Channels fromHead-End

coax

>-30dB

TV + Data

2 Mbit

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 6: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Attenuation MAS and MIO

Max output from theMAS is 108 dBuV

Min input to theMIO is 63 dBuV

Min input to theMAS is 63 dBuV

Max output fromThe MIO is 108 dBuV

Attenuation betweenMAS & MIO shouldbe 25 – 37 dBuV

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 7: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Use 3 MAS in same coax

MAS 1 DS 68 MHz US 16 MHzMAS 2 DS 72 MHz US 20 MHzMAS 3 DS 76 MHz US 24 MHz

dBuV

Fq

STOP FILTER5-65 MHz

MAS 1 MAS 2 MAS 3

SystemMAS-64MIO-04ConnectionAttenuation3 MAS 1 2UPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 8: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Use 3 MAS on same frequency

STOP FILTER5-65 MHz

STOP FILTER5-65 MHz

STOP FILTER5-65 MHz

MAS 1

MAS 2

MAS 3

MAS 1 DS 70 MHz US 20 MHzMAS 2 DS 70 MHz US 20 MHzMAS 3 DS 70 MHz US 20 MHz

SystemMAS-64MIO-04ConnectionAttenuation3 MAS 1 2UPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 9: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Allways use a UPS if possible

220v220v

• Transients and lighting (Thunderstorm)• Protect the equipment• Needs 8 min to restart

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 10: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Bandwith of the MAS

Bandwith of the upstream is 3.8 MHz as default

Bandwith of the downstream is 3,5 MHz as default

Don´t use ch.4 and down-stream lower then 70 Mhz

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwith 1 2 3Return Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 11: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Using a return-amplifier 5 – 35 MHz

Bandwith of the upstream is 3.8 MHz as default

Bandwith of the downstream is 3,5 MHz as default

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwith 1 2 3Return Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 12: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Using a return-amplifier 5 – 65 MHz

Bandwith of the upstream is 3.8 MHz as default

Bandwith of the downstream is 3,5 MHz as default

Problems !

The guardband of5 – 60/65 MHz return amplifier will interfear on the downstream.

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwith 1 2 3Return Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 13: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Passing amplifiers with no return-path

• Passing a amplifier with no return-path.

You will loose ~ 1dB in forward and ~ 1dBin return by using 2 diplex-filter.

Diplex filterDiplex filter

TV

DA

TA

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 14: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

QoS

With Macab MTR-serie (traffic-shaper) you will be able to:

• Control the bandwith to each user from 128 Kb/s up to 10 Mbit/s

• Login- / User authentification System

• VoIP (priority)

• Advanced logg-functions

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO MTR-100,200,300,400

2 Mbit/s from ISP

RJ-45coax

Page 15: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Connect the MIO

Use a patch cable to connectMIO-04

If Multimedia is availableuse MM port

Trough loss MIO to TV out47 till 860MHz < -2dB

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 16: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

System loss TV when connecting the MAS

MAS to the system with a 10 dB tap -1 dB

Passing MIO-04 -2 dB

TOTAL LOSS ON TV-CHANNELS -3 dB

MIO Max input level 90dBuV, Min input level 63 dBuV

MIO Max Output level 108 dBuV, Min Output level 90dBuV NB: AUTO LEVEL

MAS Max Output level 108 dBuV, Min Output level 70dBuV NB: Manually Adjust

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 17: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Transfer Speed

• Download speed (3 Msymb. & QAM64)

7 Mbps• Upload speed (3 Msymb. & QPSK)

3 Mbps

• Data rate MAS System Downstream

18* Mbps• Data rate MAS System Upstream

6* Mbps

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Notice! 8 bit = 1 byte

240 kB/s in downloadspeed is equal to a Internetspeed of 2 Mbit/s

Page 18: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Data capability, Different symbol rates Down Stream 64 – 76 MHz

Symbol rate Bandwidth QAM16 QAM64 QAM256

1 MS/s 1,15 MHz 4 MB/s 6 MB/s 8 MB/s

1.5 MS/s 1,73 MHz 6 MB/s 9 MB/s 12 MB/s

2 MS/s 2,3 MHz 8 MB/s 12 MB/s 16 MB/s

3 MS/s 3,45 MHz 12 MB/s 18 MB/s 24 MB/s

4 MS/s 4,6 MHz 16 MB/s 24 MB/s 32 MB/s

6 MS/s 6,9 MHz 24 MB/s 36 MB/s 48 MB/s

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 19: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Data capability, Different symbol rates Up Stream 5 – 36 MHz

Symbol rate Bandwidth QPSK

O,750 MS/s 0,937 MHz 1,5 Mb/s

1,5 MS/s 1,875 MHz 3 Mb/s

3 MS/s 3,750 MHz 6 Mb/s

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 20: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Factory default setup

• MIO-04 Upstream frequency 5-36MHz (20 MHz)QPSK, 3MS/s (6MBit), 108dBuV

• MAS Downstream frequency 64 – 76 MHz (74 MHz)QAM64, 3MS/s (18Mbit), 108dBuV

• Bridge setup

• MIO Plug & Play

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 21: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Preparations

• Measure the forward and return path frequency response

• Chose forward and return path that gives the best performance regarding loss, noise and interference

• Measure the TV channels levels to check the system performance before Multilet installation

• If you need to upgrade the system do this before Multilet installation

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 22: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

System Calculations

• Keep same level of downstream signal as the TV channels. Min level to MIO 63 dBuV.

• Calculate the return attenuation as a normal TV channel. Max transmission level of MIO is 108 dBuV. Min input level to MAS is 63 dBuV.

• Do not FORGET to include a margin.

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 23: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Ranager

Manage all IO´sSet DS & US FrequencyCheck link to all IO´s

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO

Page 24: A macab power point presentation RIAN BV WAALRE 040-2213656 CABLE –RIAN – Access System

a macab power point presentation

RIAN BV WAALRE 040-2213656

Config IO

Check link to MASSee the US powerCheck firmwareSee the US & DS frequency

SystemMAS-64MIO-04ConnectionAttenuation3 MASUPSBandwithReturn Amp.QoSMIO-04System lossSpeedDownstreamUpstreamDefaultPreparationsCalculationsRanagerConfig IO