Page 1: 72131500 Licence UpGrade SRAL XD

SRAL XD

License Upgrading Procedure

IMC 7318AEDG

Page 2: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 2/15 -

Mod. IMC 7318AEDG – Issue 01

Copyright (C) Siemens Mobile Communications S.p.A. V.le Piero e Alberto Pirelli, 10 I-20126 Milano

Issued by Technical Assistance Department S.S. 11 Padana Superiore, km 158 I-20060 Cassina de’ Pecchi MI Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract. Authors: E. Ciferri Authorized: M. Diani

Page 3: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 3/15 -

Mod. IMC 7318AEDG – Issue 01

1 SRAL XD ALLOWED CONFIGURATIONS.................................................................. 5

2 LICENSE UPGRADING PROCEDURE ....................................................................... 6

2.1 REQUIREMENTS................................................................................................. 6

2.2 PROCEDURE....................................................................................................... 7

3 ANNEX A ................................................................................................................... 14

Page 4: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 4/15 -

Mod. IMC 7318AEDG – Issue 01

REVISIONS Issue Date Author(s) Chapter(s) Cause Change

1 May 2004 E. Ciferri ALL NEW

Acronyms • MW Microwave Networks

• TAC Technical Assistance Centre

• TSO Technical Support Organization

• LC Siemens Local Company

Page 5: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 5/15 -

Mod. IMC 7318AEDG – Issue 01

1 SRAL XD ALLOWED CONFIGURATIONS

The license of the system is stored into the Memory Key unit. The license is composed by parameters as Capacity, Modulation and System Type.

When a change of configuration leads to modify one of this feature, the system check if the fees present permits the new setting.

Below the upgradeable parameters with the possible values are listed:

Parameters Meaning Default value(1) Available Value

Capacity Maximum capacity software selectable

(up to 16E1) 4E1 4E1/8E1/16E1

Modulation Maximum modulation

levels (up to HD 16TCM)

ND ND/HD

System type System type covered

(1 or 2 Base Band working)

1+0 1+0/ALL

Following table shows the allowed configurations related to the license type of IDU unit:

License type Allowed configurations

4E1,1+0, ND capacity 4X2, Not protected 1+0, ND modulation

8E1,1+0,ND capacity up to 8X2,Not protected 1+0, ND modulation

16E1,1+0,ND capacity up to 16X2,Not protected 1+0, ND modulation

8E1,1+0,HD capacity up to 8x2, Not protected 1+0, ND modulation

capacity 8x2, Not protected 1+0, HD modulation

16E1,1+0,HD capacity up to 16x2, Not protected 1+0, ND modulation

capacity 8x2/16x2, Not protected 1+0, HD modulation

4E1,1+1, ND capacity 4X2, All system types, ND modulation

8E1,1+1,ND capacity up to 8X2, All system types, ND modulation

16E1,1+1,ND capacity up to 16X2, All system types, ND modulation

8E1,1+1,HD capacity up to 8X2, All system types, ND modulation

capacity 8X2, All system types, HD modulation

16E1,1+1,HD capacity up to 16X2, All system types, ND modulation

capacity 8X2/16x2, All system types, HD modulation

(1) The default value is the minimum license for each parameter.

Page 6: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 6/15 -

Mod. IMC 7318AEDG – Issue 01

2 LICENSE UPGRADING PROCEDURE

2.1 REQUIREMENTS

In order to upgrade the License Type of IDU SRAL XD an Upgrading kit is provided.

It is composed of:

• A Smart Key (with USB interface): this key is programmed with specific number of credits and allows upgrading a specific license feature among capacity, modulation, and system type.

• A CD rom with the following files:

Readme --> this file contains important notes and instruction

LicenseManager --> contains file for install LicenseManager tool

SmartKey_Drivers --> contains port drivers for Smart Key

See Annex A. to the end of document to see all codes of offered kit.

Page 7: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 7/15 -

Mod. IMC 7318AEDG – Issue 01

2.2 PROCEDURE

This procedure is applicable to Single Board and Plug-in IDU version.

Each parameter described must be upgraded separately from the other ones.

Thus the following procedure must be repeated if more than one parameter needs to upgrade.

Note: The license downgrading is not foreseen.

1. Install LicenseManager tool running lm*_***SETUP.exe (where *_*** corresponds to the version of LicenseManager tool, for example: lm3_4b2SETUP.exe) on CD of Upgrading License Kit:

2.Flag SRAL XD

3.Press Next button

Page 8: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 8/15 -

Mod. IMC 7318AEDG – Issue 01

At the end of installation, the lm_SRAL XD shortcut is available on desktop or in Start Menu (in SIEMENS License Manager folder).

4.Press Install button

5.Press Close button

Page 9: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 9/15 -

Mod. IMC 7318AEDG – Issue 01

6.Have a connection with LCT or NetViewer to IDU SRAL XD, open Feature Control window and read License-Mask and Challenge-Number fields.

Page 10: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 10/15 -

Mod. IMC 7318AEDG – Issue 01

Important Note:

Make sure that IDU is in stable condition: do not switch of the IDU, do not perform software reset or controller switch bank up to the end of license upgrading procedure.

7. Connect Smart Key (contained in Upgrading License Kit) to appropriate PC port.

8. Run LicenseManager tool (lm_SRAL XD shortcut).

If a message below appears

the Smart Key is not properly equipped or a wrong type is used or the appropriate driver is not correctly installed. In this case run the skeyadd.exe present in the KeyP.zip folder contained in the CD-Rom.

When the LicenseManager is on run, the window below appears:

9.Write current License Mask

10.Write current Challenge Number

11. Press Show License button to verify the existing license into the Smart Key

12.Flag feature you want to enable

13.Press Generate button (*)

14.License Key is generated

Page 11: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 11/15 -

Mod. IMC 7318AEDG – Issue 01

(*) Note:

Press Generate button only when you filled all boxes with the correct values.

When License key is generated the total Credits of smart key will be decreasing according to the value of updated feature.

Moreover every License-Key is strictly associated to the IDU that has the specified License-Mask and Challenge-Number.

15. Press OK button on Status window

and DON’T CLOSE the License Key Generation window (for more safety memorize the four License-Key fields in a text file).

16. Press Modify button on Feature Control window in order to enable License Mask writing:

Page 12: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 12/15 -

Mod. IMC 7318AEDG – Issue 01

17. Copy the first field of generated License-Key into the License Key #1 field:

Copy and Paste

Double Click

Page 13: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 13/15 -

Mod. IMC 7318AEDG – Issue 01

18. Repeat previous step for the other 3 fields of License-Key and Press Upgrade button on Feature Control Window:

19. Feature Control window automatically close. Open it again and verify that License Type has the new value:

20. Close License Key Generation window (Quit button).

Page 14: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 14/15 -

Mod. IMC 7318AEDG – Issue 01

3 ANNEX A The list below shows the code of all license kit can be ordered. The kit changes about the wanted parameter to upgrade and number of fee the Smart Key has got.

CODE LICENSE UPGRADING KIT IDU SINGLEBOARD FAMILY

625-018/11A100Q SB KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (1 NE)

625-018/11A200Q SB KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (1 NE)

625-018/11A300Q SB KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (1 NE)

625-018/11A010Q SB KIT FOR EXP. FROM (1+0) TO (1+1) (1 NE)

625-018/11A001Q SB KIT FOR EXP. FROM HP TO HD (1 NE)

625-018/11B100Q SB KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (2 NEs)

625-018/11B200Q SB KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (2 NEs)

625-018/11B300Q SB KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (2 NEs)

625-018/11B010Q SB KIT FOR EXP. FROM (1+0) TO (1+1) (2 NEs)

625-018/11B001Q SB KIT FOR EXP. FROM HP TO HD (2 NEs)

625-018/11C100Q SB KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (10 NEs)

625-018/11C200Q SB KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (10 NEs)

625-018/11C300Q SB KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (10 NEs)

625-018/11C010Q SB KIT FOR EXP. FROM (1+0) TO (1+1) (10 NEs)

625-018/11C001Q SB KIT FOR EXP. FROM HP TO HD (10 NEs)

625-018/11D100Q SB KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (50 NEs)

625-018/11D200Q SB KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (50 NEs)

625-018/11D300Q SB KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (50 NEs)

625-018/11D010Q SB KIT FOR EXP. FROM (1+0) TO (1+1) (50 NEs)

625-018/11D001Q SB KIT FOR EXP. FROM HP TO HD (50 NEs)

IDU PLUG-IN FAMILY

625-018/10A100Q PI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (1 NE)

625-018/10A200Q PI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (1 NE)

625-018/10A300Q PI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (1 NE)

625-018/10A010Q PI KIT FOR EXP. FROM (1+0) TO (1+1) (1 NE)

625-018/10A001Q PI KIT FOR EXP. FROM HP TO HD (1 NE)

625-018/10B100Q PI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (2 NEs)

625-018/10B200Q PI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (2 NEs)

625-018/10B300Q PI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (2 NEs)

625-018/10B010Q PI KIT FOR EXP. FROM (1+0) TO (1+1) (2 NEs)

625-018/10B001Q PI KIT FOR EXP. FROM HP TO HD (2 NEs)

Page 15: 72131500 Licence UpGrade SRAL XD

SRAL XD License Upgrading Procedure

Document IMC 7318AEDG Issue 1, May 2004 - 15/15 -

Mod. IMC 7318AEDG – Issue 01

625-018/10C100Q PI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (10 NEs)

625-018/10C200Q PI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (10 NEs)

625-018/10C300Q PI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (10 NEs)

625-018/10C010Q PI KIT FOR EXP. FROM (1+0) TO (1+1) (10 NEs)

625-018/10C001Q PI KIT FOR EXP. FROM HP TO HD (10 NEs)

625-018/10D100Q PI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (50 NEs)

625-018/10D200Q PI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (50 NEs)

625-018/10D300Q PI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (50 NEs)

625-018/10D010Q PI KIT FOR EXP. FROM (1+0) TO (1+1) (50 NEs)

625-018/10D001Q PI KIT FOR EXP. FROM HP TO HD (50 NEs)

MINIDU FAMILY

625-018/12A100Q MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (1 NE)

625-018/12A200Q MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (1 NE)

625-018/12A300Q MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (1 NE)

625-018/12A010Q MI KIT FOR EXP. FROM (1+0) TO (1+1) (1 NE)

625-018/12A001Q MI KIT FOR EXP. FROM HP TO HD (1 NE)

625-018/12B100Q MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (2 NEs)

625-018/12B200Q MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (2 NEs)

625-018/12B300Q MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (2 NEs)

625-018/12B010Q MI KIT FOR EXP. FROM (1+0) TO (1+1) (2 NEs)

625-018/12B001Q MI KIT FOR EXP. FROM HP TO HD (2 NEs)

625-018/12C100Q MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (10 NEs)

625-018/12C200Q MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (10 NEs)

625-018/12C300Q MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (10 NEs)

625-018/12C010Q MI KIT FOR EXP. FROM (1+0) TO (1+1) (10 NEs)

625-018/12C001Q MI KIT FOR EXP. FROM HP TO HD (10 NEs)

625-018/12D100Q MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (50 NEs)

625-018/12D200Q MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (50 NEs)

625-018/12D300Q MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (50 NEs)

625-018/12D010Q MI KIT FOR EXP. FROM (1+0) TO (1+1) (50 NEs)

625-018/12D001Q MI KIT FOR EXP. FROM HP TO HD (50 NEs)