RDW2 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 1600, 2500, 4000, 6300A

Rated current: 200A~6300A

Rated operating voltage: AC 400V, AC 690V

Number of pole: 3P, 4P

Breaking capacity: 25kA~125kA

Installation mode: Fixed type, Drawer type

RDW1 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 630, 1000, 2000, 3200, 4000, 6300A

Rated current: 100A~6300A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 42kA~120kA

Installation mode: Fixed type, Drawer type

RDW17 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 1600, 1605, 2500, 2505, 3200, 3205A

Rated current: 630A~5000A

Rated operating voltage: AC 380V, AC 660V

Number of pole: 3P, 4P

Breaking capacity: 50kA~80kA

Installation mode: Fixed type, Drawer type

DW15 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 630, 1600, 2500, 4000, 6300A

Rated current: 200A~6300A

Rated operating voltage: AC 380V

Number of pole: 3P

Breaking capacity: 20kA~80kA

Installation mode: Fixed type, Drawer type (only for 630 type)

DW16 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 630, 2000, 4000A

Rated current: 100A~4000A

Rated operating voltage: AC 400V

Number of pole: 3P

Breaking capacity: 20kA~80kA

RDM1 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 63, 100, 250, 400, 630, 800, 1250A

Rated current: 10A~1250A

Rated operating voltage: AC 400V, AC 690V

Number of pole: 2P (only for 100, 250 type), 3P, 4P

Breaking capacity: 25kA~100kA

RDM1E Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 63, 100, 250, 400, 630, 800, 1250A

Rated current: 10A~1250A

Rated operating voltage: AC 400V, AC 690V

Number of pole: 3P, 4P

Breaking capacity: 25kA~100kA

RDM11 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 100, 160, 250, 400, 630A

Rated current: 16A~630A

Rated operating voltage: AC 690V

Number of pole: 3P, 4P

Breaking capacity: 25kA~50kA

www.peopleelectric.com 016

Distribution Components

RDW2 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 1600, 2500, 4000, 6300A

Rated current: 200A~6300A

Rated operating voltage: AC 400V, AC 690V

Number of pole: 3P, 4P

Breaking capacity: 25kA~125kA

Installation mode: Fixed type, Drawer type

RDW1 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 630, 1000, 2000, 3200, 4000, 6300A

Rated current: 100A~6300A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 42kA~120kA

Installation mode: Fixed type, Drawer type

RDW17 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 1600, 1605, 2500, 2505, 3200, 3205A

Rated current: 630A~5000A

Rated operating voltage: AC 380V, AC 660V

Number of pole: 3P, 4P

Breaking capacity: 50kA~80kA

Installation mode: Fixed type, Drawer type

DW15 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 630, 1600, 2500, 4000, 6300A

Rated current: 200A~6300A

Rated operating voltage: AC 380V

Number of pole: 3P

Breaking capacity: 20kA~80kA

Installation mode: Fixed type, Drawer type (only for 630 type)

DW16 Series Intelligent Universal Circuit Breaker

Confirms to: IEC60947-2

Frame size: 630, 2000, 4000A

Rated current: 100A~4000A

Rated operating voltage: AC 400V

Number of pole: 3P

Breaking capacity: 20kA~80kA

RDM1 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 63, 100, 250, 400, 630, 800, 1250A

Rated current: 10A~1250A

Rated operating voltage: AC 400V, AC 690V

Number of pole: 2P (only for 100, 250 type), 3P, 4P

Breaking capacity: 25kA~100kA

RDM1E Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 63, 100, 250, 400, 630, 800, 1250A

Rated current: 10A~1250A

Rated operating voltage: AC 400V, AC 690V

Number of pole: 3P, 4P

Breaking capacity: 25kA~100kA

RDM11 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 100, 160, 250, 400, 630A

Rated current: 16A~630A

Rated operating voltage: AC 690V

Number of pole: 3P, 4P

Breaking capacity: 25kA~50kA

www.peopleelectric.com 016

RDM6 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 125, 160, 250, 400, 630, 800, 1250, 1600A

Rated current: 12.5A~1600A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 25kA~65kA

DZ20 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 100, 225, 400, 630, 1250, 2000A

Rated current: 16A~2000A

Rated operating voltage: AC 380V

Number of pole: 3P, 4P

Breaking capacity: 18kA~100kA

RDM108 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 20, 32, 63A

Rated current: 0.16A~63A

Rated operating voltage: AC 660V

Number of pole: 3P

Breaking capacity: 1.5kA~22kA

DZ15 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 40, 100A

Rated current: 6A~100A

Rated operating voltage: AC 220V, AC 380V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 3kA~5kA

RDM10 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 100, 160, 400, 630A

Rated current: 16A~630A

Rated operating voltage: AC 400V

Number of pole: 3P

Breaking capacity: 7.5kA~15kA

RDM1L Series Residual OperatedCircuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 225, 400, 800A

Rated current: 10A~800A

Rated operating voltage: AC 400V

Number of pole: 2P (only for 100M, 225L, 225M type), 3P, 4P

Breaking capacity: 35kA~100kA

Residual operated current: 30/100/300/500/1000mA

RDL20 Series Residual OperatedCircuit Breaker

Confirms to: IEC60947-2

Frame size: 160, 250, 400, 630A

Rated current: 50A~630A

Rated operating voltage: AC 380V

Number of pole: 3P +N

Breaking capacity: 12kA~30kA

Residual operated current: 100/200/300/500mA

RDM30LE Series Intelligent LeakageCircuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 250, 400, 630A

Rated current: 63A~630A

Rated operating voltage: AC 380V

Number of pole: 3P +N

Breaking capacity: 6kA~36kA

Residual operated current: 100/300/500/1000mA

DZL25 Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 250A

Rated current: 40A~250A

Rated operating voltage: AC 380V

Number of pole: 4P

Breaking capacity: 6kA, 10kA

Residual operated current: 30/50/100/200/300/500mA

DZ15LE Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 40, 100A

Rated current: 6A~100A

Rated operating voltage: AC 220V, AC 380V

Number of pole: 2P, 3P, 4P

Breaking capacity: 3kA, 5kA

Residual operated current: 30/50/75/100mA

RDM10L Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 250A

Rated current: 40A~250A

Rated operating voltage: AC 380V

Number of pole: 4P

Breaking capacity: 6kA, 10kA

Residual operated current: 75/100/150/200/300mA

RDL18 Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 20, 32A

Rated current: 10A~32A

Rated operating voltage: AC 220V

Number of pole: 2P

Breaking capacity: 500A

Residual operated current: 30mA

RDQH Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Frame size: 63, 100, 225, 400, 630, 800, 1250, 1600A

Rated current: 10A~1600A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 5kA~35kA

ATS grade: CB class

RDQ1 Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Frame size: 63A

Rated current: 6A~63A

Rated operating voltage: AC 220V, AC 400V

Number of pole: 2P, 3P, 4P

Breaking capacity: 5kA

ATS grade: CB class

RDWQ2 Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Frame size: 1000, 2000, 3200, 4000, 6300A

Rated current: 200A~6300A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 10kA~100kA

ATS grade: CB class

RDQ6 Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Rated current: 63A~3150A

Rated operating voltage: AC 400V

Number of pole: 2P, 3P, 4P

Breaking capacity: 5kA~80kA

ATS grade: PC class

www.peopleelectric.com 018017 www.peopleelectric.com

Distribution Components

RDM6 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 125, 160, 250, 400, 630, 800, 1250, 1600A

Rated current: 12.5A~1600A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 25kA~65kA

DZ20 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 100, 225, 400, 630, 1250, 2000A

Rated current: 16A~2000A

Rated operating voltage: AC 380V

Number of pole: 3P, 4P

Breaking capacity: 18kA~100kA

RDM108 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 20, 32, 63A

Rated current: 0.16A~63A

Rated operating voltage: AC 660V

Number of pole: 3P

Breaking capacity: 1.5kA~22kA

DZ15 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 40, 100A

Rated current: 6A~100A

Rated operating voltage: AC 220V, AC 380V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 3kA~5kA

RDM10 Series Moulded Case Circuit Breaker (MCCB)

Confirms to: IEC60947-2

Frame size: 100, 160, 400, 630A

Rated current: 16A~630A

Rated operating voltage: AC 400V

Number of pole: 3P

Breaking capacity: 7.5kA~15kA

RDM1L Series Residual OperatedCircuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 225, 400, 800A

Rated current: 10A~800A

Rated operating voltage: AC 400V

Number of pole: 2P (only for 100M, 225L, 225M type), 3P, 4P

Breaking capacity: 35kA~100kA

Residual operated current: 30/100/300/500/1000mA

RDL20 Series Residual OperatedCircuit Breaker

Confirms to: IEC60947-2

Frame size: 160, 250, 400, 630A

Rated current: 50A~630A

Rated operating voltage: AC 380V

Number of pole: 3P +N

Breaking capacity: 12kA~30kA

Residual operated current: 100/200/300/500mA

RDM30LE Series Intelligent LeakageCircuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 250, 400, 630A

Rated current: 63A~630A

Rated operating voltage: AC 380V

Number of pole: 3P +N

Breaking capacity: 6kA~36kA

Residual operated current: 100/300/500/1000mA

DZL25 Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 250A

Rated current: 40A~250A

Rated operating voltage: AC 380V

Number of pole: 4P

Breaking capacity: 6kA, 10kA

Residual operated current: 30/50/100/200/300/500mA

DZ15LE Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 40, 100A

Rated current: 6A~100A

Rated operating voltage: AC 220V, AC 380V

Number of pole: 2P, 3P, 4P

Breaking capacity: 3kA, 5kA

Residual operated current: 30/50/75/100mA

RDM10L Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 100, 250A

Rated current: 40A~250A

Rated operating voltage: AC 380V

Number of pole: 4P

Breaking capacity: 6kA, 10kA

Residual operated current: 75/100/150/200/300mA

RDL18 Series Leakage Circuit Breaker

Confirms to: IEC60947-2

Frame size: 20, 32A

Rated current: 10A~32A

Rated operating voltage: AC 220V

Number of pole: 2P

Breaking capacity: 500A

Residual operated current: 30mA

RDQH Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Frame size: 63, 100, 225, 400, 630, 800, 1250, 1600A

Rated current: 10A~1600A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 5kA~35kA

ATS grade: CB class

RDQ1 Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Frame size: 63A

Rated current: 6A~63A

Rated operating voltage: AC 220V, AC 400V

Number of pole: 2P, 3P, 4P

Breaking capacity: 5kA

ATS grade: CB class

RDWQ2 Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Frame size: 1000, 2000, 3200, 4000, 6300A

Rated current: 200A~6300A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 10kA~100kA

ATS grade: CB class

RDQ6 Series Dual Power SupplyAutomatic Transfer Switch

Confirms to: GB/T14048.11

Rated current: 63A~3150A

Rated operating voltage: AC 400V

Number of pole: 2P, 3P, 4P

Breaking capacity: 5kA~80kA

ATS grade: PC class

www.peopleelectric.com 018017 www.peopleelectric.com

Distribution Components

RDH5D Series Dual Power Supply Automatic Transfer Switch

Confirms to: GB/T14048.11

Rated current: 32A~3200A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 5kA~80kA

ATS grade: PC class

HD, HS Series Open Type Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 200, 400, 600, 1000, 1500, 2000, 3000A

Rated current: 100~3000A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~50kA

Number of pole: 1P, 2P, 3P, 4P

HS11FH Series Protective Open Type Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400A

Rated current: 100~400A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~20kA

Number of pole: 3P, 4P

HD11F Series Open Type Knife Switch

Mistake-proof

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400A, 600, 1000, 1500A

Rated current: 100~1500A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~40kA

Number of pole: 3P, 4P

HD11FH Series Protective Open Type Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400A

Rated current: 100~400A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~20kA

Number of pole: 3P, 4P

HR3 Series Fuse Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400, 600, 1000A

Rated current: 100~1000A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Number of pole: 3P

RDHG1 Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Rated current: 32~63A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 3P

HR18 Series Fuse Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated current: 160~630A

Rated operating voltage: AC 400V, AC 660V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 3P

RDHG2B Series Strip Type Fuse Switch Disconnector

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated current: 160~630A

Rated operating voltage: AC 400V, AC 690V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 3P

HR5 Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated operating voltage: AC 380V, AC 660V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50~100kA

Number of pole: 3P

HR6 Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated operating voltage: AC 380V, AC 660V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50~100kA

Number of pole: 3P

HR17B Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 40, 60, 160, 250, 400, 630A

Rated operating current: 40~630A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 2P, 3P, 4P

RDH5 Series Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 63, 100, 125, 160, 200, 400, 630, 1000,1250, 1600, 2000, 2500, 3200A

Rated operating current: 63~3200A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Operation mode: operation inside of cabinet, operationoutside of cabinet

Number of pole: 3P, 4P

RDH5R Series Isolation Switch Fuse Group

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 400, 630A

Rated operating current: 160~630A

Rated operating voltage: AC 380V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Number of pole: 2P, 3P, 4P

HH15 Series Isolation Switch Fuse Group

Confirms to: GB14048.3, IEC60947-3

Rated operating current: (QSA) 63~800A (QA) 125~1000A (QP) 250~3150A

Rated operating voltage: AC 380V, AC 660V, Rated limit short-circuit current: 50kA

Operation mode: operation outside of cabinet

Number of pole: 3P

JDW2 Series Low Voltage OutdoorIsolation Switch

Confirms to: GB14048.3, IEC60947-3

Rated operating current: 200~800A

Rated operating voltage: AC 500V

www.peopleelectric.com 020019 www.peopleelectric.com

Distribution Components

RDH5D Series Dual Power Supply Automatic Transfer Switch

Confirms to: GB/T14048.11

Rated current: 32A~3200A

Rated operating voltage: AC 400V

Number of pole: 3P, 4P

Breaking capacity: 5kA~80kA

ATS grade: PC class

HD, HS Series Open Type Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 200, 400, 600, 1000, 1500, 2000, 3000A

Rated current: 100~3000A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~50kA

Number of pole: 1P, 2P, 3P, 4P

HS11FH Series Protective Open Type Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400A

Rated current: 100~400A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~20kA

Number of pole: 3P, 4P

HD11F Series Open Type Knife Switch

Mistake-proof

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400A, 600, 1000, 1500A

Rated current: 100~1500A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~40kA

Number of pole: 3P, 4P

HD11FH Series Protective Open Type Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400A

Rated current: 100~400A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated short-time withstand current: 6kA~20kA

Number of pole: 3P, 4P

HR3 Series Fuse Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 100, 200, 400, 600, 1000A

Rated current: 100~1000A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Number of pole: 3P

RDHG1 Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Rated current: 32~63A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 3P

HR18 Series Fuse Knife Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated current: 160~630A

Rated operating voltage: AC 400V, AC 660V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 3P

RDHG2B Series Strip Type Fuse Switch Disconnector

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated current: 160~630A

Rated operating voltage: AC 400V, AC 690V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 3P

HR5 Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated operating voltage: AC 380V, AC 660V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50~100kA

Number of pole: 3P

HR6 Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 250, 400, 630A

Rated operating voltage: AC 380V, AC 660V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50~100kA

Number of pole: 3P

HR17B Series Fuse Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 40, 60, 160, 250, 400, 630A

Rated operating current: 40~630A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Electrical life: 200~600 times

Number of pole: 2P, 3P, 4P

RDH5 Series Isolation Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 63, 100, 125, 160, 200, 400, 630, 1000,1250, 1600, 2000, 2500, 3200A

Rated operating current: 63~3200A

Rated operating voltage: AC 400V

Rated impact withstand voltage: 8kV

Operation mode: operation inside of cabinet, operationoutside of cabinet

Number of pole: 3P, 4P

RDH5R Series Isolation Switch Fuse Group

Confirms to: GB14048.3, IEC60947-3

Frame size: 160, 400, 630A

Rated operating current: 160~630A

Rated operating voltage: AC 380V

Rated impact withstand voltage: 8kV

Rated limit short-circuit current: 50kA

Number of pole: 2P, 3P, 4P

HH15 Series Isolation Switch Fuse Group

Confirms to: GB14048.3, IEC60947-3

Rated operating current: (QSA) 63~800A (QA) 125~1000A (QP) 250~3150A

Rated operating voltage: AC 380V, AC 660V, Rated limit short-circuit current: 50kA

Operation mode: operation outside of cabinet

Number of pole: 3P

JDW2 Series Low Voltage OutdoorIsolation Switch

Confirms to: GB14048.3, IEC60947-3

Rated operating current: 200~800A

Rated operating voltage: AC 500V

www.peopleelectric.com 020019 www.peopleelectric.com

Distribution Components

HH3 Series Load Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 60, 100, 150, 200, 300, 400, 600A

Rated current: 60~600A

Rated voltage: AC 380V

Rated limit short-circuit current: 50kA

Number of pole: 3P

HH4 Series Load Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 15, 30, 60, 100A

Rated current: 15~100A

Rated voltage: AC 380V

Rated limit short-circuit current: 50kA

Number of pole: 3P

HK2 Series Load Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 16, 32, 63, 75A

Rated current: 16~75A

Rated voltage: AC 220V, AC 380V

Rated limit short-circuit current: 50kA

Number of pole: 2P, 3P

RDT16 Series Powder Filled CartridgeKnife Type Contact FuseConfirms to: GB/T13539.2, IEC60269-2

Rated current: 10~1250A

Rated voltage: Up to AC 690V

Rated breaking capacity: 120kA

Scope of breaking and usage category: gG type and aM type

It is mainly used for electric circuit’s over-load and short-circuit protection

RDF16 Series Powder Filled CartridgeKnife Type Contact Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 16~630A

Rated voltage: Up to AC 690V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RL1 Series Screw Type Fuse

Confirms to: GB/T13539.3, IEC60269-3

Rated current: 2~200A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT18, HG30 Series Powder Filled Cartridge Cylindrical Cape Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 2~125A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG typeand aM type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT19 Series Powder Filled Cartridge Cylindrical Cape Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 2~100A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG typeand aM type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT14 Series Powder Filled Cartridge Cylindrical Cape Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 2~63A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT0 Series Powder Filled Cartridge Knife Type Contact Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 10~1000A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RS0, RS3 Series Fast Fuse

Confirms to: GB/T13539.4, IEC60269-4

Rated current: (RS 0) 10A~1250A (RS 0) 10A~1000A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: aR type

It is mainly used for the protection of semiconductorcrystal tube and its complete equipment

NGT Series Fast Fuse

Confirms to: GB/T13539.4, IEC60269-4

Rated current: 25~630A

Rated voltage: AC 380V, 660V, 800V, 1000V

Rated breaking capacity: 100kA

Scope of breaking and usage category: aR type

It is mainly used for the protection of semiconductorcrystal tube and its complete equipment

BSMJ (Y), BZMJ (Y) Series Auto-Healing Low Voltage Shunt Capacitor

Confirms to: GB/T12847, IEC831-1

Rated operating voltage: AC 250V, AC 400V, AC 450V AC 525V, AC 690V, AC 750V

Rated capacity: 1-50kvar

It can be used with CJ 19, combination switch

RD-ZM Series Intelligent Low Voltage Capacitor

Confirms to: GB/T29312

Rated operating voltage: AC 380V/ 220V

Rated capacity: total compensation of 5~40kvar;

separated compensation of 5~20kvar

It can compensation in situ by one machine, and also can networking to intelligently automatic operation by multi-machines, and no need to add reactive compensationcontroller to control.

JKW5C Series Low Voltage ReactiveCompensation Controller

Confirms to: JB/T 9663

Rated operating voltage: AC 220V/ 380V

Rated current: AC 0~5A

Capacity of contacts: AC 220V 5A

Controlled circuit No.: 1~12 circuits

Protection grade: IP40

JKW6C Series Low Voltage ReactiveCompensation Controller

Confirms to: JB/T 9663

Rated operating voltage: AC 220V/ 380V

Rated current: AC 0~5A

Capacity of contacts: AC 220V 5A

Controlled circuit No.: 1~12 circuits

Protection grade: IP40

www.peopleelectric.com 022021 www.peopleelectric.com

Distribution Components

HH3 Series Load Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 60, 100, 150, 200, 300, 400, 600A

Rated current: 60~600A

Rated voltage: AC 380V

Rated limit short-circuit current: 50kA

Number of pole: 3P

HH4 Series Load Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 15, 30, 60, 100A

Rated current: 15~100A

Rated voltage: AC 380V

Rated limit short-circuit current: 50kA

Number of pole: 3P

HK2 Series Load Switch

Confirms to: GB14048.3, IEC60947-3

Frame size: 16, 32, 63, 75A

Rated current: 16~75A

Rated voltage: AC 220V, AC 380V

Rated limit short-circuit current: 50kA

Number of pole: 2P, 3P

RDT16 Series Powder Filled CartridgeKnife Type Contact FuseConfirms to: GB/T13539.2, IEC60269-2

Rated current: 10~1250A

Rated voltage: Up to AC 690V

Rated breaking capacity: 120kA

Scope of breaking and usage category: gG type and aM type

It is mainly used for electric circuit’s over-load and short-circuit protection

RDF16 Series Powder Filled CartridgeKnife Type Contact Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 16~630A

Rated voltage: Up to AC 690V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RL1 Series Screw Type Fuse

Confirms to: GB/T13539.3, IEC60269-3

Rated current: 2~200A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT18, HG30 Series Powder Filled Cartridge Cylindrical Cape Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 2~125A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG typeand aM type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT19 Series Powder Filled Cartridge Cylindrical Cape Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 2~100A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG typeand aM type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT14 Series Powder Filled Cartridge Cylindrical Cape Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 2~63A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RT0 Series Powder Filled Cartridge Knife Type Contact Fuse

Confirms to: GB/T13539.2, IEC60269-2

Rated current: 10~1000A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: gG type

It is mainly used for electric circuit’s over-load and short-circuit protection

RS0, RS3 Series Fast Fuse

Confirms to: GB/T13539.4, IEC60269-4

Rated current: (RS 0) 10A~1250A (RS 0) 10A~1000A

Rated voltage: AC 380V

Rated breaking capacity: 50kA

Scope of breaking and usage category: aR type

It is mainly used for the protection of semiconductorcrystal tube and its complete equipment

NGT Series Fast Fuse

Confirms to: GB/T13539.4, IEC60269-4

Rated current: 25~630A

Rated voltage: AC 380V, 660V, 800V, 1000V

Rated breaking capacity: 100kA

Scope of breaking and usage category: aR type

It is mainly used for the protection of semiconductorcrystal tube and its complete equipment

BSMJ (Y), BZMJ (Y) Series Auto-Healing Low Voltage Shunt Capacitor

Confirms to: GB/T12847, IEC831-1

Rated operating voltage: AC 250V, AC 400V, AC 450V AC 525V, AC 690V, AC 750V

Rated capacity: 1-50kvar

It can be used with CJ 19, combination switch

RD-ZM Series Intelligent Low Voltage Capacitor

Confirms to: GB/T29312

Rated operating voltage: AC 380V/ 220V

Rated capacity: total compensation of 5~40kvar;

separated compensation of 5~20kvar

It can compensation in situ by one machine, and also can networking to intelligently automatic operation by multi-machines, and no need to add reactive compensationcontroller to control.

JKW5C Series Low Voltage ReactiveCompensation Controller

Confirms to: JB/T 9663

Rated operating voltage: AC 220V/ 380V

Rated current: AC 0~5A

Capacity of contacts: AC 220V 5A

Controlled circuit No.: 1~12 circuits

Protection grade: IP40

JKW6C Series Low Voltage ReactiveCompensation Controller

Confirms to: JB/T 9663

Rated operating voltage: AC 220V/ 380V

Rated current: AC 0~5A

Capacity of contacts: AC 220V 5A

Controlled circuit No.: 1~12 circuits

Protection grade: IP40

www.peopleelectric.com 022021 www.peopleelectric.com

Distribution Components

JKL6C, JKL6B Series Low Voltage Reactive Compensation Controller

Confirms to: JB/T 9663

Rated operating voltage: AC 220V/ 380V

Rated current: AC 0~5A

Capacity of contacts: AC 220V 5A

Controlled circuit No.: 1~12 circuits

Protection grade: IP 40

JKG2B, JKW5B Series Low Voltage Reactive Compensation Controller

Confirms to: JB/T 9663

Rated operating voltage: AC 220V/ 380V

Rated current: AC 0~5A

Capacity of contacts: AC 220V 5A

Controlled circuit No.: 1~12 circuits

Protection grade: IP 40

JKWR Series Low Voltage Reactive Compensation Controller

Confirms to: JB/T 9663

Rated operating voltage: AC 220V

Rated current: AC 0~5A

Capacity of contacts: AC 220V 7A

Controlled circuit No.: 1~13 circuits

Protection grade: IP 40

DB Series Distribution Box

JXF Series Outdoor DistributionBox Enclosure

Rated voltage: 220/380V

Rated current: 125A

Installation: Surface mounted

Protection grade: Ip65

Height: 250; 300; 400; 500; 600; 800; 1000; 1200mm, etc.

Width: 200; 250; 300; 400; 500; 600; 1000mm, etc.

Depth: 150; 200; 250; 300mm, etc.

Modules: 4, 6, 8, 12, 18, 24, 34 ways

Installation: Surface mounting, Flush mounting

Material: Plastic, Metal

Protection grade: IP40

023 www.peopleelectric.com