23 march 2016 microscada pro sys600 total solution for ...file/abb+microscada+-sas+semin… ·...

33
© ABB Group March 22, 2016 | Slide 1 ABB MicroScada Pro Release Tour 2.0 – 23 th March 2016 MicroSCADA Pro SYS600 Total solution for Substation Automation System [email protected]

Upload: vukien

Post on 20-Apr-2018

286 views

Category:

Documents


11 download

TRANSCRIPT

Page 1: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 1

ABB MicroScada Pro Release Tour 2.0 – 23th March 2016

MicroSCADA Pro SYS600Total solution for SubstationAutomation System [email protected]

Page 2: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 2

Substation Automation SystemsPortfolio

Systems forcontrol,protection andmonitoring oftransmission todistribution AIS,GIS and hybridsubstations

Protectionsystems for theprimaryequipment inpower plants,substations aswell as industrialapplications

Prefabricatedbay houses forsubstationautomation,protection andcontrol includingcommunicationsand cabling formedium to high-voltage AIS &GIS substations

Monitoring andcontrol systemsfor utilities,industries andinfrastructure(eg, railways,tunnels, largebuildings, etc.)

Integrated solutions for grid reliability, industrial productivity and energy efficiency

Robust global value chain to serve established and emerging markets

Extensive global network of value-added channel partners

Substationautomation Protection Small SCADA Drop-in P&C

houses

Systems foronline protectionand control ofpower systemstability based oncurrent andvoltage phasormeasurements

Wide-areaprotection

Page 3: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

ABB Portfolio and architecture

© ABB GroupMarch 22, 2016 | Slide 3

IEC 61850-8-1

IEC 61850-9-2

Frontend

MUSAMU

IED Configuration

SystemConfiguration

670 series REB500

RTU560SYS600C

MicroSCADA Pro

RTU540

smallSCADADMS600

RTU540630 series 620 series

650 series

650 series

SAMU

615 series

Combiflex

RTU511

Tools

Page 4: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 4

Substation Automation SystemsMarkets served

Electrical grids

Industry

Power plants

all around the globe

Wind farms

Railways

Page 5: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 5

Technology overview

RTU RTU RTU

RTU RTU RTUParallel,hardwiredcabling

Interbay bus Interbay bus

Process bus

Station bus Station bus

Conventional Modern(retrofit)

Modern Intelligent(retrofit)

Intelligent

Network level

Station level

Bay level

Process level

Parallel,hardwiredcabling

Parallel,hardwiredcabling

Page 6: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 6

ABB AB B M ASTER

IP

A BB ABB MASTE R

IP

RTU

NLDC

MARSHALING RACK

Conventional Architecture

Conventional Vs Modern Architecture

Protection panels

Control panels

Page 7: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 7

What is going on in the market ?

12

4

5

8

39

68C

ubic

les,

>180

Dev

ices

è Line

èTransformer

è Busbar

è Feeder

è Control

1960 1970 1980 1990 2000 2010?

Figures for Reference Station - 220/33kV S/S - 6nos 220kV feeders & 8 nos 33kV feeders

12

4

3

8

39

66C

ubic

les,

>160

Dev

ices

6

4

3

4

39

56C

ubic

les,

>140

Dev

ives

6

2

3

4

3247

Cub

icle

s,>1

00D

evic

es

13C

ubic

les,

>50

Dev

ices

3

1

7

2

4

Morepowerfuldevices.Functionalintegrationon going

Functional integration

Page 8: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 8

Proc

ess

Leve

lB

ayLe

vel

Stat

ion

Leve

l

GIS or AISSwitchgear

-Q1

-Q0 -Q8-Q9

-Q2

1

38

=D04+R01225kV LIGNE ABOBO 1ABB

125VDC Distributuion Battery A 125VDC Distributuion Battery B

FaultRecording

=D04+R01225kV LIGNE ABOBO 1ABB

125VDC Distributuion Battery A 125VDC Distributuion Battery B

BAY CONTROL RELAY REC316*41ABB

2435678912111314151610LOCAL CONTROL METERING

LINE PROTECTION RELAY REL316*41ABB

ABB2435678912111314151610BUSBAR PROTECTION REB500

ABB

-Q1==12345678910111213141516cc

Bay Protection

LocalControl

=D04+R01225kV LIGNE ABOBO 1ABB

125VDC Distributuion Battery A 125VDC Distributuion Battery B

Busbar ProtectionSCADA

RTU=D04+R01225kV LIGNE ABOBO 1ABB

125VDC Distributuion Battery A 125VDC Distributuion Battery B

RTU 200IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 OUT

ON/OFF

RTU 200IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 OUT

ON/OFF

RTU 200IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 OUT

ON/OFF

=D04+R01225kV LIGNE ABOBO 1ABB

125VDC Distributuion Battery A 125VDC Distributuion Battery B

EventRecording

BayControl

=D04+R01225kV LIGNE ABOBO 1ABB

ABB

-Q2SEL

-Q1SEL

-Q0SEL

=W1

=W2

FERMEROUVRIR

EXEESC

LAMPETESTE

DISTANCELOC

ABB ABB ABB

=D04+R01225kV LIGNE ABOBO 1ABB

ABB

-Q2SEL

-Q1SEL

-Q0SEL

=W1

=W2

FERMEROUVRIR

EXEESC

LAMPETESTE

DISTANCELOC

ABB ABB ABB

For each function a dedicated deviceand separate kiosks Extensive station

wide cabling

Extensive bay cabling

Conventional Substation Control

Conventional Vs Modern Architecture

Page 9: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 9

IEC 61850The standard in substation automation

EPRI

IEC61850Is the first truly global standard in the electric

utility fieldHas been established by some 60 experts from

Europe and North AmericaInfluences other areas like wind and hydro

power plants, distributed energy resources,etc.

IEC61850 provides:Process-oriented data model, independent

of communication technologyStandardized description of primary and

secondary apparatuses and theirfunctionality

Compatible data exchange betweenengineering tools

Real-time capabilities for vertical andhorizontal (bay-bay) communication

IEC61850“Communicationnetworks andsystems insubstations ”

Page 10: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 10

Substation automation solutionsThe smart way to operate your substations

SAS 600 Series station-level solutionsfor:Reliable local and/or remote control and

monitoring of substations atAll voltage levelsAny configurationEvery size

Integration of bay-level solutionsFully distributed functionalityOpen connectivity (to remote control centers,

integration of third-party IEDs)

Secure operation

Indoor GIS substation Outdoor AIS substation Distribution substationHybrid substation

Page 11: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 11

Typical structure of a SubstationScalable architectures

Stat

ion

leve

lB

ayle

vel

Proc

ess

leve

l

Functions

Station automationMonitoringFault evaluationEvent & alarm viewing

and AcknowledgementRemote communication for

Telecontrol & supervision

ProtectionControlMonitoringInterlockingData acquisition

GIS or AIS switchgearInstrument transformersPower transformersSurge arrestersNon-conventional transformers

Page 12: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 12

ABB’s station and bay level solutions

SAS600 Seriesstation levelsolutions

Secure localand/or remotecontrol andmonitoring ofall substations

BPS600 Seriesbay protectionsolutions

Flexiblerealization ofyour protectionphilosophy andschemes

BCS600 Seriesbay controlsolutions

Optimizedpackages forlocal andremote controlin MV to EHVsubstationsFuture-proof systems with IEC61850

interoperability for optimal life cycle managementand low lifecycle cost

Page 13: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 13

Enhanced SASSAS650

SAS630

Advanced SASSAS690

SAS670

ABB Substation Automation Systems SolutionStation Level

Components

Station HMIMicroSCADA PRO

GatewayCOM581

COM500

RTU560

Station busIEC61850-8-1

Basic SASSAS610

Page 14: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 14

Substation automation solutions – Station Level

Page 15: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 15

Substation automation solutionsGeneral selection guide

Customer requirements SAS 605 SAS 610 SAS 630 / 635 SAS 650 SAS 670 SAS 690

FunctionalityBasic control and monitoring of substations ● ● ● ● ● ●Advanced control and monitoring functions Option Option Option Option OptionOperationRemote only ●Local only ● ●Local and remote with priority on local Option ●Local and remote with priority on remote Option ●Local and remote with equally high priority Option ●Recommended applicationSubstationDistribution and subtransmission ● ●High-voltage transmission ● ● ●Extra voltage transmission ● ●Complex distribution ● ●

Page 16: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 16

RTU560G-based substation automation systemsCompact low-end solution

Main characteristicsCentralized compact DIN-rail-mountable

RTUFocus on remote controlConnection of I/O modulesSupports various protocols for IED

integration (IEC61850, IEC103, DNP3.0and Modbus)

System functionsTime synchronization üBasic user authority handling üGroup alarms, group signals ü

Basic monitoring and control functionsSystem supervision, alarms, events, status indications,measurements ü

Remote control, monitoring and diagnostics (Gateway) ü

Advanced monitoring and control functionsUploading and storage of disturbance fault records ü

System sizeNumber of bay-level IEDs (estimation) 1..20Max. number of data points (fix limitation) 750Max. number of serial ports eg, for IEC101, IEC103, .. 2Max. number of Ethernet Ports eg, for IEC61850, IEC104, … 1

Smallest distribution applications,proxy

Page 17: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 17

SAS605 – flexible RTU-based solutionDistribution and sub-transmission applications

Main characteristicsCentralized RTU-based station computerDirect I/O boardsLarge number of protocols for IED

integration and remote communicationsupported

Focus on remote control, optional basiclocal control

System functionsTime synchronization üBasic user authority handling üGroup alarms, group signals ü

Basic monitoring and control functionsSystem supervision, alarms, events, status indications,measurements ü

Remote control, monitoring and diagnostics (Gateway)

Local control and monitoring (HMI) ü

Advanced monitoring and control functionsUploading and storage of disturbance fault records ü

System sizeNumber of bay level IEDs (estimation) 1..60Max. number of data points (fix limitation) 5’000Number of remote links 4Number of IEC61850 Networks 1..3

Page 18: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 18

SAS635 – flexible RTU-based solutionDistribution and sub-transmission applications

Main characteristicsDistributed station level devicesRTU-based gatewayLarge numbers of protocols for IED

integration and remote communicationsupported

Highly reliable remote control andadvanced local control functionality

System functionsTime synchronization üMulti level user authorization handling üVersatile language support, including operator-specific languages üGroup alarms, group signals üBlocking list üZooming, panning, de-cluttering ü

Basic monitoring and control functionsSystem supervision, alarms, events, status indications,measurements ü

Remote control, monitoring and diagnostics (Gateway) üSingle line pictures and system supervision pictures üControl dialogues, select before execute for operation ü

Advanced monitoring and control functionsRemote parameter setting and reading üUploading and storage of disturbance fault records üFault record analysis üMeasurement reports üTrends üExternal alarming (e-mail, short message, fax…) üDynamic busbar coloring üAutomatic sequence control ü

System sizeNumber of bay level IEDs (estimation) 1..60Max. number of data points (fix limitation) 5’000Number of remote links 4Number of IEC61850 Networks 1..3

Page 19: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 19

SAS610…690 - high-end solutionsHigh-end solutions for a range of applications

Main characteristicsDistributed station-level devicesScalable architecture and functionality (from

single to fully redundant systemarchitecture, from basic to advancedfunctions)

Large systems supported (large numbers ofIEDs, highest performance)

Extremely high flexibility (functionality,communication topology)

System FunctionsTime synchronization üMulti level user authorization handling üVersatile language support, including operator-specific languages üGroup alarms, group signals üBlocking list üZooming, panning, de-cluttering üRedundancy (hot stand-by) ü

Basic monitoring and control functionsSystem supervision, alarms, events, status indications,measurements ü

Remote control, monitoring and diagnostics (Gateway) üSingle line pictures and system supervision pictures üControl dialogues, select before execute for operation ü

Advanced monitoring and control functionsRemote parameter setting and reading üUploading and storage of disturbance fault records üFault record analysis üMeasurement reports üTrends üExternal alarming (e-mail, short message, fax…) üDynamic busbar coloring üAutomatic sequence control ü

System SizeNumber of bay level IEDs (estimation) 1..150 *)Max. number of data points (fix limitation) > 10’000Number of remote links 4 *)Number of IEC61850 Networks 1..3 *)

*) more on request

Page 20: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 20

SAS 610…690Overview, basic functions

Primary equipment supervision Control Secure operation

Measurements

AlarmsSystem supervision

User management

Sequences of events

Page 21: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 21

SAS 610…690Overview, advanced functions

DR upload and Analysis Measurement Trends and Reports Trip Counter Table

Load Shedding

Automatic SequencesExternal Alarming

IED parameterization

Dynamic Busbar Coloring

Page 22: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 22

Bay Level - Protection Panel & a Modern control Panel

BPS 6xxLine ProtectionMain 1 RED67087L67N79 AR25DRLine protectionMain 2 REL65021 Z<67N79 AR2527 / 59Busbar Protection500BU02BBPBFP

BCS 6xxModern BayControl

BCM 800REC650

Page 23: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 23

ApplicationFunctionalityPerformance

670 series

610 series

650 series

630 series

605 series

615 series

Sub-transmission TransmissionDistribution

Relion® Product Family - Positioning

Page 24: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 24

Relion® Product FamilyActual portfolio per application

Application Type 670 series 650 series 630 series 615 series 610 series 605 series

Feeder protection & control REF ● ● ● ●

Bay control REC ● ●

Transformer protection RET ● ● ● ●

Line distance protection REL ● ●

Line differential protection RED ● ●

Motor protection REM ● ● ●

Generator protection REG ● ●

Busbar protection REB ● ●

Breaker protection REQ ●

Voltage protection REU ● ●

Load shedding PML ●

Shunt reactor protection REG ●

Shunt capacitor bankprotection RET/REC ●

Covers all applications, from interconnected transmission grids to secondary distribution kiosks

Page 25: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

SAS System Configuration

© ABB GroupMarch 22, 2016 | Slide 25

150kV GIS/AIS Substation System

Page 26: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

Power Grid – Grid AutomationLocal Team Support

© ABB GroupMarch 22, 2016 | Slide 26

PGGAPGGA

SalesSales EngineeringEngineering ProjectManagement

ProjectManagement Field ServiceField Service

Mr. Anton Bangun (Manager)Mr. Irwan Santoso (Key Account)Mr. Eko Setiawan (SAS)Mr. Ridzky Arya (Telcom)Ms. Ulil Ulya (Tech Support)

Mr. Moh Adil (Manager)Mr. MustafaMr. Insanul AzisMr. Rifqi MarzuqiMr. RahmadMr. M YaqinMr. Irfan

Mr. Hario P (Manager)Mr. Parlin SihotangMs. Genesia

Mr. M. Hanafi (Manager)Mr. Ayub SMs. LiaMs. AlfaisMr. Harfizuldy

Mr.Predrag G

Page 27: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

Our Project References

© ABB GroupMarch 22, 2016 | Slide 27

Package 9 Jawa Region

Kudus 150 kV S/S

Consist of 11 Bays (8 Line Bays, 2 Tranformer Bays, 1 Bus Coupler)SAS using MicroScada Pro Software & RTU560 as Gateway

East Kalimantan

Kayutangi 150 kV S/S

Consist of 3 Bays ( 2 Line Bays, 1 Tranformer Bays)SAS using MicroScada Pro Software & RTU560 as Gateway

South Kalimantan

Batulicin 150 kV S/S

Consist of 3 Bays ( 2 Line Bays, 1 Tranformer Bays)SAS using MicroScada Pro Software & RTU560 as GatewayRedundant SAS Server (Hot & Standby)

Page 28: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

Our Several Local Project References

© ABB GroupMarch 22, 2016 | Slide 28

Site Location Project Year

Blora, Pati, Kudus, Rembang,Jekulo, Wonosari, Solo Baru 150 kV(Package-9)

Jawa Tengah 2008

Kayutangi 150 kV KalimantanSelatan 2008

Batu Licin 150 kV KalimantanSelatan 2009

Kedung Badak, Depok, Mandirancan150 kV (ADB) Jawa Barat 2010

Pringgabaya 150 kV Nusra 2010

Nguntoronadi 150 KV Jawa Tengah 2010

Serang 150 kV Banten 2010

Meulaboh kV Aceh 2010

Betano 150 kV Timor Leste 2011

Lautan Steel 150 kV Jawa Barat 2011

PLTU Kaltim Kalimantan Timur 2012

KDL Pass 150 kV Jawa Barat 2012

Gumawang Sumatra Selatan 2013

Page 29: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

The next steps towardsDigital Substation

Page 30: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

Evolution of process bus

IEC 61850 Station Bus

IEC 61850 Process Bus

Remote control

Analog / 9-2LE

Station levelSAS600 series of substation automationsolutions with IEC 61850 station bus

Bay level670 series control and protection IEDsREB500 Busbar Protection system

IET600 SAS Expert Engineering &ITT600 SA Explorer to Access andmonitor ApplicationsProcess level - NCITNon Conventional Instrument Transformer

ABB NCITs for GIS, CP-MU merging unit forELK-CP14 and ELK-CP3(current and voltage)ABB LTB with integratedFiber Optic Current Sensor FOCS-MU(current only)

Page 31: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

Evolution of process bus

IEC 61850 Station Bus

IEC 61850 Process Bus

Remote control

Analog / 9-2LE

Make process bus available for anyconvention instrument transformer

9-2LE for Conventional Current andVoltage Transformer from any primaryequipment vendor

Combine newest ABB FOCStechnology with ConventionalInstrument Transformer

Merge NCIT Current with ConventionalVoltage Transformer to 9-2LE

Scalable and modular I/O platformfor process level installations

Page 32: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

SAM600 I/O SystemDigitizing Primary signals made easy

§ Modular I/O Platform for interfacing primary equipment§ Fully IEC 61850 compliant

§ Extendable Bus architecture to chain up multiple Modules

§ Conventional current or voltage transformers (1.0)

§ High Precision Time synchronization

§ Circuit breaker, Disconnector, Earthing switches (2.0)

§ Optimized form factor for Indoor and Outdoor Application§ Bay cubicles for retrofit applications

§ Marshaling kiosks, VT terminal boxes for new or retrofitinstallations

§ Customizable Termination for primary cabling§ Process interface terminals are part of SAM600

§ Analog modules include binary inputs forMCB supervision and test switch indication

SAM600-CT

SAM600-VT

RE.670

REB500

GPS

9-2LE

1PPS

1588

SAM600-TS

3rd

party

Page 33: 23 March 2016 MicroSCADA Pro SYS600 Total solution for ...file/ABB+MicroSCADA+-SAS+Semin… · Total solution for Substation Automation System Eko.Setiawan@id.abb.com ... transmission

© ABB GroupMarch 22, 2016 | Slide 33