1 introduction to the softwarethe electricity quantity records. data shows in list and with...
TRANSCRIPT
1 Introduction to the software
The monitoring software is matched with our company controller. It can monitor different controller models for
local monitor and remote monitor. Main functions include: displaying real-time data for wind power, solar panel
power, battery; storage and transferring system operation data; modify and set the controller parameters; control
wind turbine operating status. Monitoring data displays through curvilinear figure, real-time data tables, stimulated
diagrams and other forms. Users can be warned by alarm mode, the alarm content is saved automatically for
reference. This software is simple to use with large capacity, full functions, multi-language version, etc. The
following are brief introduction to every function model.
Multi-type interface unit:
The software supports a variety of forms such as serial com port, GPRS, internet etc. Controller can directly be
connected with serial port in the local; when the controller is distributed in different locations, especially in the
wild, you can connect it through the GPRS or wired Internet. Access types can be mixed in use. And a typical
multi-use-pattern is showing below:
Database Storage Unit:
This software can choose the MYSQL database system or ACCESS database system according to node number.
ACCESS database system is recommended for a dozen or dozens of node numbers. It is convenient and quick and
you do not need to install separately but with limited storage capability. So for hundred of node number, user is
recommended to choose MYSQL database system (If choose the MYSQL database, user need to install the
MYSQL database software at the end of the software installation.)
Multi-type Display Unit:
Software display type includes the trends chart, mimic diagram, data table, multi-channel display. Trends chart
shows node data trends of the controller in a period time. The graph can show the data for wind, solar and battery.
Mimic diagram directly show the wind turbine, wind power, solar power data and running state. Date table shows
real-time data intensively through the database forms, data refresh auto by time. Multi-channel display divides by
region, the running state of the controller in the region shall be displayed in which you choose.
1/21 Introduction to the software
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Introduction%20to%20softw...
Parameter configuration unit
No matter the access form is a serial port GPRS or wired network, the software can configure and control the
controller running state. After connected with PC, the system can identify different types of controller auto, user
can check and adjust the parameters, change wind turbine running state or reset factory default through the
software.
2/21 Introduction to the software
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Introduction%20to%20softw...
2 Software Installation
2.1 System Requirement
2.2 Installation Procedure
1. In system Windows 7, Vista, Windows 8, right click on the installer “WPNet Setup.exe” , start the
software via “run as administrator” , the program installation is starting. (Remark: In
system Windows 2000, Windows XP just double-click on the “WPNet Setup.exe” to install the program.) Click
[Next] to continue.
2. Select database and click [Next] to continue. If MYSQL is selected then you need to install MYSQL database.
Item Recommendations
CPU Dual-core 1GHz or above
Memory 1G or above
Hard Disk 4G or above
Operation System Windows XP, Vista, Windows 7,windows 8
Resolution 1024×768
1/52 Software Installation
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Software%20Installation.htm
3. Input the User information and click [Next].
4. Select installation path in your disk. Click [Next].
2/52 Software Installation
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Software%20Installation.htm
5. Create shortcuts and click [Next].
6. Click [Finish] to exit.
3/52 Software Installation
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Software%20Installation.htm
Note: If you select MYSQL database during the installation process, then firstly you should save mysql-5.1.46-
win32.msi (MYSQL database installation files) and mysql-connector-odbc- 5.1.6-win32.msi (MYSQL database
ODBC driver) in the same directory with the monitoring software, then install monitoring software first. You need
to install mysql-5.1.46-win32.msi and mysql-connector-odbc-5.1.6-win32.msi again at the end of software
installation. You need to configure the MYSQL database in the installation process of mysql-5.1.46-win32.msi. In
the following interface, the “New root password” edit box should be filled with “power121”, other configurations
are just set as default.
4/52 Software Installation
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Software%20Installation.htm
2.3 Uninstall software
Click “Start->Program->WinPower Net->unload WinPower Net” to uninstall this software.
5/52 Software Installation
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Software%20Installation.htm
Wind & Solar Hybrid Controller Monitoring Software
User Manual
Version: 3.0
1/1Wind & Solar Hybrid Controller Monitoring Software
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Wind%20Solar%20Hybrid%...
3.1 Starting the software
The software can be started by:
� Selecting “Start->Programs->WinPowerNet”
� Double-clicking the WinPowerNet desktop shortcut
Notes: In system Vista, Windows 7 or Windows 8, have to right-click the WinPowerNet desktop shortcut and
select the “run as administrator” item to start the software.
After the software start, the main interface appears, as shown below.
1/13
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Starting%20the%20Software....
3.2 Menu Bar
3.2.1 System― Switch User
The submenu can be used to switch the current user logining the software. The default current user is anyone
when the software starts. You can change the current user to be admin. The default password of user admin to
login the software is admin. Only the user admin has the access to setting the controller parameters and wind
turbine running state.
― Exit
The submenu can be used to exit from the software
1/13
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System.htm
3.2.2 View
The software has four kind of interface to display data including trend diagram, data table, simulation graph and
multi-path graph. The menu can be used to switch the interface among them.
― Trend Diagram
After software starts, the default screen shows trend diagram as above. The meaning of each function area in the
trend diagram is as following.
A: Area & nodes displaying list, click the node in the list then the data of selected node will be displayed in the
trend.
B: Trend diagram options, click the check-box to choose or cancel the option, the trend of checked options will be
displayed at the same time.
C: Voltage-time trend, displaying voltage curve of checked option, the time length is 10 minutes.
D: Power-time trend, displaying power curve of checked option, the time length is 10 minutes.
E: Voltage-time and power-time radar graph, displaying voltage and power curve of checked option in a radar
graph. The length of time is 24 hours, if the time lasts longer than 24 hours, the data will be displayed in cycle
automatically. The red line points to the current time.
F: Real-time data showing area, showing the real-data of selected node, including voltage, current, instantaneous
power, daily total power, monthly total power and yearly total power of batteries, the wind generator and solar
panels, etc.
G: State signal indication, the details is shown in the table as below.
Red Green Yellow Gray
Communication
State
Normal No signal
Battery State Over-Voltage
Lower-Voltage
Normal No signal
Wind State Brake Normal Unloading or
No signal
Overload or Load1 is on and No signal
1/33
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/View.htm
H: Instant Message Bar: when system is abnormal (such as short circuit, over-voltage, over-speed brake, low
voltage etc.), the alarm sounds, and instant message bar will display the corresponding error at the same time.
Alarm sounds will be released when users click alarm confirmation.
― Data Table
The data table displays real-time data of selected node within 20 seconds, including voltage, current, power of
battery, wind turbine, solar panels; load current and fan speed.
― Simulation Graph
Output1 State Short circuit Current is normal
but zero
Load1 is on but
current is zero
Load1 is off
Output2 State
Overload or
Short circuit
Load2 is on and
Current is normal
but zero
No signal
Load2 is on but
Current is zero
Load2 is off
2/33
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/View.htm
Simulation graph shows systematic relationship chart and the real time data of battery, wind turbine, solar in
current system.
― Multi-path Graph
Multi-path graph is used to show load state of all controllers in the same area, and gives convenience for user to
monitor the running status of loads. The upper indicator of each icon shows the load state of controller and the
lower indicator shows the load2 state of controller.
3/33
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/View.htm
3.2.3 Tools
The software stores large amount of historical data records in computer when runs. The records include historical
data of system running, log information, alarm information and system power records. Tools menu is used to check
these records. The function of it’s submenus is described as below.
― Query History Data
Click “Tools->Query History Data”, the query data interface will show as above.
After choosing “Area Name” and “Ctrl Name”, setting “Begin Time” and “End Time”, click “Requery” button, the
historical data of the controller between begin time and end time will be listed in the data grid. Click “Save To
Excel” button, the software will export the historical data into an excel file.
Click “Curve” button, the graphic interface displays as the following figure shows. Click check-box selecting the
parameters to display in the graphic interface. Different parameter curve shows with different color. Click “Adjust
View Range” button to adjust the display range of parameters.
1/43
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Tools.htm
― Query Log
Click “Tools->Query Log”, the log query widow shows as above. Select time period and event type, click “Query”
button then log information will be listed in the grid.
2/43
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Tools.htm
― Query Power
Click “Tools->Query Power”, the power query widow shows as above. Select the controller by region and
controller name, and choose query format as by day or month or year, then click "Requires" button user can view
the electricity quantity records. Data shows in list and with histogram style. Clicking on the "Next>>" or "<<Prev"
button can change query date. Click the “Save To Excel” button, the records in the list will be saved to an excel
file.
― Query Alarm
3/43
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Tools.htm
Click “Tools -> Query Alarm”, the alarm query window shows as above. Select the controller by area name and
controller name, input time period and select alarm type, then click “Query” button, the related alarm information
will be listed in the grid.
Note: When the communication between the software and the controller has been built, the software will sample
the data from the controller automatically. If Access database is selected when install the software, all the data will
be exported to excel files every day after 0 o’clock and the database will be cleared up. Excel files are saved to sub-
folder “HisData” where the software is installed.
4/43
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Tools.htm
3.2.4 Setting
The menu is used to set area and node information, adjust controller system parameters and control the state of
wind generator. But only the user admin has the privilege to adjust system parameters and control the state of wind
generator. The menu has four submenus including parameters setting, fan’s state control, area & node setting and
options.
― Parameters Setting
If current user is anyone, you have to switch it to admin. Then click “Setting -> Parameters Setting”, a frame shows
as below.
Select area name and controller name, then click “Connect” button. The controller parameters setting interface
displays as below.
The interface may be some different according to different controllers. You can change the parameters in the
interface, then click “Save Para” button to save the changes. Or click “Restore Factory” button to restore the
factory parameters. Otherwise you can select another controller name and click “Connect” button to view or change
it’s parameters. The meaning of parameters is described as following.
General: Release Voltage, when battery voltage is up to the voltage, the controller begins to unload. Release
Current, when wind current is up to the current, the controller begins to unload. Device ID, is the number of
controller.
1/63
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Setting.htm
Charge: it applys for the lower-voltage-charge controllers. The admittance and start charge should be set according
to the characteristics of the wind turbine output so that the wind turbine could achieve the best effect to match the
controller.
Output: Less Voltage, when battery voltage is lower than the voltage, the load will be off. Over Voltage, when
battery voltage is up to the voltage, the load will be off. LessVolRes voltage, if the battery voltage increases to the
voltage from lower-voltage state first time, the load will be on again. Day point voltage, if the sun panels’ output
voltage is upper than the voltage, the controller predicates that it’s day time. Night Point voltage, if the sun panels’
output voltage is lower than the voltage, the controller predicates that it’s night time. The day point voltage and
night point voltage can be used to control the load state.
Load: Load output mode setting, including light control on/off, light control on/time control off, always on/off,
light control on/off/time control half power, light control on/time control half power/ time control off, always half
power.
― Running State Control
If current user is anyone, you have to switch it to admin. Then Click “Setting -> Running State Control”, the
following interface will appear. Select area and controller name, then click “Connect” button, the current state of
wind turbine will show in the interface.
Select the state option which you want the wind turbine to be, and then click “Save” button to save the change.
― Area & Node Setting
Click “Setting -> Area & Node Setting”, the area and node setting interface will appear as below.
2/63
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Setting.htm
A. Area Setting
In the “Area Setting” tab, input the area name and area memo, click “Add Area” button to add an area, and the area
information will shown in the list on the left hand side. By clicking “Remove Area” button you can remove the
selected area in the list.
B. Node Setting
In the “Node Setting” tab, select an area from area list, input the controller name which will be shown as the node
name, and then select an interface type from type list. There are five types to be selected, including Serial Server
(WM) Serial Server Com 485 Bus and WM Server.
3/63
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Setting.htm
If the interface type is Serial Server (WM), Module ID and Password are required as following.
If the interface type is Serial Server, Device IP is required as following.
4/63
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Setting.htm
If the interface type is COM, then the COM PORT is required as following.
If the interface type is 485 Bus, then Com Port and Device ID is required as following:
5/63
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Setting.htm
If the interface type is WM Server, Module ID and Password are required as following.
By clicking "Add Node" button, controller node can be added and shown in the list below. Clicking “Remove
Node” button can remove the selected node in the list.
Note: After modifying the area and node setting, you have to click “Save” button to make the modification come
into effect. Then restart the software.
6/63
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Setting.htm
4 System Integration and Configuration
The software supports a variety of interfaces and can construct the local serial ports, remote network, remote
wireless, mix varieties of forms above as monitoring system. It meets user demands fully in different environments.
System composition could be from single controller to hundreds of controllers. System scalability is strong and
flexible.
4.1 RS232 serial
If the distance between the controller and the monitor computer is less than fifteen meters, it is best to choose
RS232 serial communication. The system composition diagram shows as below.
Operation steps:
1. Connect the controller to the monitor computer with rs232 serial port cable.
2. Start the software, set area and node, the interface type should be Com and select the corresponding com port.
3. Restart the software, the software begins to sample data automatically.
For computers without serial ports, such as laptops, you can use the usb to serial converters as the communication
cable.
Note: Recommended to use the computer with serial port for long-term data acquisition.
4.2 RS485 serial system
For long distance monitoring it can be set up with a RS485 data collection system. The system composition
diagram shows as below.
A. Monitor a single controller with rs485 interface
Operation steps:
1 Connect the controller with rs485 interface to the monitor computer with rs485 to rs232 converters. Otherwise
you can install the rs485 repeaters to extend the communication distance.
1/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
2 Start the software, set area and node, the interface type should be Com and select the corresponding com port.
3 Restart the software, the software begins to sample data automatically.
B. Monitor several controllers with rs485 interface at the same time
Operation steps:
1. Following the operation steps in the A part above to set an area and a node. Connect the controllers to computer
one by one, set the device id of all controllers to be different with one another, because the id of device should be
unique in the same rs485 bus.
2. Connect all controllers to monitor computer in parallel with one rs485 to rs232 converters, add an area and a
node, the interface type should be 485 bus, select the corresponding com port and the device id can keep the
default.
3. Restart the software, click the node added in the step 2, the rs485 node searching tool will appear at the upper of
the window as below.
Input the corresponding com port, begin address and end address. All the device id of controllers should be
contained in the range of begin address to end address. Click “Search” button to search all the controllers in the 485
bus.
4. After the searching process finishes, restart the software, the nodes of controllers searched will be shown in the
area & nodes list at the right hand side of the window. The software begins to sample data automatically.
4.3 Local multi-serial port monitoring system
Through Multi-serial-port Card user can set up multi controllers monitoring system. Currently popular Multi-serial-
port Card is PCI bus interface card. The multi-serial port monitoring system diagram shows as below.
Operation steps:
1. Shut down monitoring computer, and then install the multi-serial-port card to computer PCI slots.
2. Start the computer, and then install the multi-serial-port card drive, virtual serial ports will be generated in the
computer.
3. Connect controllers to multi-serial-port card with rs232 communication cable. Start the software, set area and
nodes, the interface type should be Com, select the corresponding com port.
4. Restart the software, the software begins to sample data automatically.
4.4 Local area network monitoring system
2/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
Choosing the controller with network interface or the serial server produced by our company can directly connect
the controller to the Internet, and realize the local area network monitor. The local area network monitoring system
diagram shows as below.
Operation steps:
1 Connect the serial server and a computer for configuring to the same router with Ethernet cable. The way to
get IP address of the computer should be configured to get dynamic IP from router.
2. Power on the serial server, and then start the configuration software in the computer, the interface of the
software shows as below.
3/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
Input “1” to select the first item of menu. The software will search the serial server in the local network and list
their information in the interface.
3. Select the second item of the menu and input an IP address in the list to configure the serial server parameters.
4/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
4. Select the item you need to change in the list above to modify the configuration. If there is more than one serial
server in the same monitoring system, you have to change the MAC address of all servers to be different with one
another. And the remote IP address should be the same as the IP address of the monitoring computer. Remote port
address should be changed to 65000.Other parameters need not to be changed just same as shown in the picture
above. Input “S” to make modifications come to effect.
5. After configuring is done. Connect the controller with serial port interface to the serial server with rs232 serial
port cable. Connect the serial server to a router in the local area network. The DHCP service of the router has to be
started to assign IP address to computer dynamically.
6. Select a computer in the local area network as monitoring computer whose IP address should be the same as the
remote IP address in the serial server. Start monitoring software in the computer, configure area and node, the
interface type should be Serial Server (WM). Input Module ID and Password which are labeled on the serial server.
7. Restart the software, the software begins to sample data automatically.
Note: For the controller with network interface, the serial server just is installed inside the controller. Please refer
to the operation steps above to configure.
4.5 Wired remote network monitoring system
By choosing the serial server and cloud server developed by our company or the universal serial server such as
CNS311, you can connect the controller to the Internet, and realize the remote network monitor.
A. Remote network monitoring system based of the serial server and cloud server developed by our company.
The system diagram shows as below.
5/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
Operation steps:
1. Connect the controller with serial port interface to the serial server with rs232 serial port cable. Connect the
serial server to a router. Power on the serial server.
2. Start the monitoring software in the remote monitor computer. Configure area and nodes, the interface type
should be “WM Server”. Input Module ID and Password which are labeled on the serial server if the server is used
first time. After the node logins the remote server, you can change the Password in the area and node setting
interface.
3. Restart the software, the node will login the remote server automatically and begin to sample data.
Note: The router connected with the serial server should access to Internet and the DHCP service has to be started
to assign IP address to computer dynamically. The remote monitor computer should have access to Internet. For the
controller with network interface, the serial server just is installed inside the controller. Please refer to the operation
steps above to configure.
B. Remote network monitoring system based of the universal serial server such as CNS311. The system diagram
shows as below.
6/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
Operation steps:
1. The universal serial server configuration (for CNS311 here)
1> Select a computer for configuring the CNS311, and configure the IP address of the computer to be static and
under the same subnet with the CNS311. The default IP address of CNS311 is “192.168.1.60”, the default subnet
mask is “255.255.255.0”. Connect the CNS311 to the computer with Ethernet cable. Power on the CNS311.
2> Run CNS311 Config Tool in the computer under the same local area network with CNS311. Click “Refresh
Device List” button to search the CNS311 device in the local area network and list them in the device list. Select a
device in the list, then click “read” button to read parameters of the device selected and show them at the right hand
side of the window.
7/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
3> Select the parameter in the list, then input value in the edit box or down-list box at the upper right of the
interface. Click “Write” button to save the modification. To make the modification come into effect, you have to
reset the device by clicking “reset” button or power on it second time. The parameters should be configured as
following.
Parameter Name Value
Mac address Not same value for each device
Auto get IP Close
IP address The static IP address of device in the local area
network where the device will work
Subnet mask The same value as subnet mask of the local area
network where the device will work
Gateway IP address The gateway IP address of the local area network
where the device will work
Net mode TCP client
Remote IP/domain 1. The public IP address of the local area network
where monitor computer works should be filled if
the device and monitor computer are not in the
same network..
2. The static IP address of monitor computer
8/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
1. Monitoring center configuration
If network type is small LAN -> router -> ADSL and then make configuration of router. Open the service port
64000, bind it to LAN IP of the computer running monitoring software.
Start the software in the monitor computer, configure area and node, the interface should be Serial Server. Input the
device IP. If monitoring the controller in the LAN, the device IP should be the static IP of serial server. If
monitoring the controller in the WAN, the device IP should be the public IP of serial server. If use the way of
domain name, have to install the dynamic DNS client-side and run it in the monitor computer.
3. Restart monitoring software, the software begins to sample data automatically.
4.6 GPRS monitoring system
For scattered area, it can realize remote wireless monitoring through the GPRS DTU and cloud server developed by
our company. The system diagram shows as below
Operation steps:
1. Insert the SIM card opened GPRS data transmission function to the card slot of GPRS DTU, connect the
controller to GPRS DTU via rs232 serial port cable and power on the DTU.
2. Start the monitoring software in the monitor computer. Select “Parameters Setting->Area & Node Setting”, add
area and node, the interface type is “WM Server”, Input Module ID and Password which are labeled on the GPRS
DTU if it is used first time. After the node logins the remote server, you can change the Password in the area and
node setting interface.
3. Restart the software, the node will login the remote server automatically and begin to sample data.
should be filled if the device and monitor
computer work in the same local area network.
3. If use the way of domain name, then fill out the
domain name instead.
Remote Port number 64000
Local Port number 64000
Serial Port Mode Transparent mode
Baud rate 9600
Data Option 8N1
Flow control Close
Packet end char null
Packet interval 1
9/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
4.7 Mixed monitoring system
For the monitoring systems which have different communication ways and scattered places, all-in-one mixed
monitoring is accepted. It is made up of RS232/485 serial port ways, wired communication ways, GPRS wireless
communication ways etc. It can centralize several monitoring system. The system diagram shows as below.
Configuration steps please refer to above.
10/104 System Integration and Configuration
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/System%20Integration%20an...
4.1 RS232 serial
If the distance between the controller and the monitor computer is less than fifteen meters, it is best to choose
RS232 serial communication. The system composition diagram shows as below.
Operation steps:
1. Connect the controller to the monitor computer with rs232 serial port cable.
2. Start the software, set area and node, the interface type should be Com and select the corresponding com port.
3. Restart the software, the software begins to sample data automatically.
For computers without serial ports, such as laptops, you can use the usb to serial converters as the communication
cable.
Note: Recommended to use the computer with serial port for long-term data acquisition.
1/14
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/RS232%20serial.htm
4.2 RS485 serial system
For long distance monitoring it can be set up with a RS485 data collection system. The system composition
diagram shows as below.
A. Monitor a single controller with rs485 interface
Operation steps:
1 Connect the controller with rs485 interface to the monitor computer with rs485 to rs232 converters. Otherwise
you can install the rs485 repeaters to extend the communication distance.
2 Start the software, set area and node, the interface type should be Com and select the corresponding com port.
3 Restart the software, the software begins to sample data automatically.
B. Monitor several controllers with rs485 interface at the same time
Operation steps:
1. Following the operation steps in the A part above to set an area and a node. Connect the controllers to computer
one by one, set the device id of all controllers to be different with one another, because the id of device should be
unique in the same rs485 bus.
2. Connect all controllers to monitor computer in parallel with one rs485 to rs232 converters, add an area and a
node, the interface type should be 485 bus, select the corresponding com port and the device id can keep the
default.
3. Restart the software, click the node added in the step 2, the rs485 node searching tool will appear at the upper of
the window as below.
Input the corresponding com port, begin address and end address. All the device id of controllers should be
contained in the range of begin address to end address. Click “Search” button to search all the controllers in the 485
bus.
4. After the searching process finishes, restart the software, the nodes of controllers searched will be shown in the
area & nodes list at the right hand side of the window. The software begins to sample data automatically.
1/14
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/RS485%20serial%20system....
4.3 Local multi-serial port monitoring system
Through Multi-serial-port Card user can set up multi controllers monitoring system. Currently popular Multi-serial-
port Card is PCI bus interface card. The multi-serial port monitoring system diagram shows as below.
Operation steps:
1. Shut down monitoring computer, and then install the multi-serial-port card to computer PCI slots.
2. Start the computer, and then install the multi-serial-port card drive, virtual serial ports will be generated in the
computer.
3. Connect controllers to multi-serial-port card with rs232 communication cable. Start the software, set area and
nodes, the interface type should be Com, select the corresponding com port.
4. Restart the software, the software begins to sample data automatically.
1/14
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Local%20multi-serial%20por...
4.4 Local area network monitoring system
Choosing the controller with network interface or the serial server produced by our company can directly connect
the controller to the Internet, and realize the local area network monitor. The local area network monitoring system
diagram shows as below.
Operation steps:
1 Connect the serial server and a computer for configuring to the same router with Ethernet cable. The way to
get IP address of the computer should be configured to get dynamic IP from router.
2. Power on the serial server, and then start the configuration software in the computer, the interface of the
software shows as below.
1/34
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Local%20area%20network%...
Input “1” to select the first item of menu. The software will search the serial server in the local network and list
their information in the interface.
3. Select the second item of the menu and input an IP address in the list to configure the serial server parameters.
2/34
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Local%20area%20network%...
4. Select the item you need to change in the list above to modify the configuration. If there is more than one serial
server in the same monitoring system, you have to change the MAC address of all servers to be different with one
another. And the remote IP address should be the same as the IP address of the monitoring computer. Remote port
address should be changed to 65000. Other parameters need not to be changed just same as shown in the picture
above. Input “S” to make modifications come to effect.
5. After configuring is done. Connect the controller with serial port interface to the serial server with rs232 serial
port cable. Connect the serial server to a router in the local area network. The DHCP service of the router has to be
started to assign IP address to computer dynamically.
6. Select a computer in the local area network as monitoring computer whose IP address should be the same as the
remote IP address in the serial server. Start monitoring software in the computer, configure area and node, the
interface type should be Serial Server (WM). Input Module ID and Password which are labeled on the serial server.
7. Restart the software, the software begins to sample data automatically.
Note: For the controller with network interface, the serial server just is installed inside the controller. Please refer
to the operation steps above to configure.
3/34
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Local%20area%20network%...
4.5 Wired remote network monitoring system
By choosing the serial server and cloud server developed by our company or the universal serial server such as
CNS311, you can connect the controller to the Internet, and realize the remote network monitor.
A. Remote network monitoring system based of the serial server and cloud server developed by our company.
The system diagram shows as below.
Operation steps:
1. Connect the controller with serial port interface to the serial server with rs232 serial port cable. Connect the
serial server to a router. Power on the serial server.
2. Start the monitoring software in the remote monitor computer. Configure area and nodes, the interface type
should be “WM Server”. Input Module ID and Password which are labeled on the serial server if the server is used
first time. After the node logins the remote server, you can change the Password in the area and node setting
interface.
3. Restart the software, the node will login the remote server automatically and begin to sample data.
Note: The router connected with the serial server should access to Internet and the DHCP service has to be started
to assign IP address to computer dynamically. The remote monitor computer should have access to Internet. For the
controller with network interface, the serial server just is installed inside the controller. Please refer to the operation
steps above to configure.
B. Remote network monitoring system based of the universal serial server such as CNS311. The system diagram
1/44
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Wired%20remote%20networ...
shows as below.
Operation steps:
1. The universal serial server configuration (for CNS311 here)
1> Select a computer for configuring the CNS311, and configure the IP address of the computer to be static and
under the same subnet with the CNS311. The default IP address of CNS311 is “192.168.1.60”, the default subnet
mask is “255.255.255.0”. Connect the CNS311 to the computer with Ethernet cable. Power on the CNS311.
2> Run CNS311 Config Tool in the computer under the same local area network with CNS311. Click “Refresh
Device List” button to search the CNS311 device in the local area network and list them in the device list. Select a
device in the list, then click “read” button to read parameters of the device selected and show them at the right hand
side of the window.
2/44
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Wired%20remote%20networ...
3> Select the parameter in the list, then input value in the edit box or down-list box at the upper right of the
interface. Click “Write” button to save the modification. To make the modification come into effect, you have to
reset the device by clicking “reset” button or power on it second time. The parameters should be configured as
following.
Parameter Name Value
Mac address Not same value for each device
Auto get IP Close
IP address The static IP address of device in the local area
network where the device will work
Subnet mask The same value as subnet mask of the local area
network where the device will work
Gateway IP address The gateway IP address of the local area network
where the device will work
Net mode TCP client
Remote IP/domain
1. The public IP address of the local area network
where monitor computer works should be filled if
the device and monitor computer are not in the
same network..
2. The static IP address of monitor computer
3/44
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Wired%20remote%20networ...
1. Monitoring center configuration
If network type is small LAN -> router -> ADSL and then make configuration of router. Open the service port
64000, bind it to LAN IP of the computer running monitoring software.
Start the software in the monitor computer, configure area and node, the interface should be Serial Server. Input the
device IP. If monitoring the controller in the LAN, the device IP should be the static IP of serial server. If
monitoring the controller in the WAN, the device IP should be the public IP of serial server. If use the way of
domain name, have to install the dynamic DNS client-side and run it in the monitor computer.
3. Restart monitoring software, the software begins to sample data automatically.
should be filled if the device and monitor
computer work in the same local area network.
3. If use the way of domain name, then fill out the
domain name instead.
Remote Port number 64000
Local Port number 64000
Serial Port Mode Transparent mode
Baud rate 9600
Data Option 8N1
Flow control Close
Packet end char null
Packet interval 1
4/44
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Wired%20remote%20networ...
4.6 GPRS monitoring system
For scattered area, it can realize remote wireless monitoring through the GPRS DTU and cloud server developed by
our company. The system diagram shows as below
Operation steps:
1. Insert the SIM card opened GPRS data transmission function to the card slot of GPRS DTU, connect the
controller to GPRS DTU via rs232 serial port cable and power on the DTU.
2. Start the monitoring software in the monitor computer. Select “Parameters Setting->Area & Node Setting”, add
area and node, the interface type is “WM Server”, Input Module ID and Password which are labeled on the GPRS
DTU if it is used first time. After the node logins the remote server, you can change the Password in the area and
node setting interface.
3. Restart the software, the node will login the remote server automatically and begin to sample data.
1/14
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/GPRS%20monitoring%20sys...
4.7 Mixed monitoring system
For the monitoring systems which have different communication ways and scattered places, all-in-one mixed
monitoring is accepted. It is made up of RS232/485 serial port ways, wired communication ways, GPRS wireless
communication ways etc. It can centralize several monitoring system. The system diagram shows as below.
Configuration steps please refer to above.
1/14
2017-09-20mk:@MSITStore:D:\WinPower%20Net\helpEng.chm::/Mixed%20monitoring%20sys...
5 FAQ
5.1 No data display when serial port collecting
Display real time electrical quantities in the bottom of tendency chart, if data display is always “0.0”, please check
status indicator light in the bottom right corner. If communication indicator light is yellow and display
“communication no signal”, that is communication bug possibly, user should check serial port’s hardware
connection and serial port setting of parameters setting. If both connection and setting are correct, please check
whether the controller is powered up correctly.
5.2 No operating right
For the parameters setting and staff management, dialog box about operating right may pop out, user can switch to
the user in the menu who has related right to operate again.
5.3 GPRS can not collect data after collecting for a while
Check whether network environment is changed or not, whether SIM is overdue or not.
5.4 Data can not be collected after setting Area and Node
After setting Area and Node, system should restart the software.
5.5 Still pictures with USB to serial port module collecting
If use serial port collecting, it is recommended to use PC with serial port. If use USB virtual serial port, the
software may not read data successfully as USB virtual serial port is unstable.
5.6 Vista/Windows7 system saving data fault
Vista and Windows7 system strengthens user permission management. At the configuration area panel port,
software need read-write magnetic disk file when outputting Excel file, if user has no writing magnetic disk
authorization , will cause software running abnormal, so it is necessary to assign software writing magnetic disk
authorization. For that how to assign permission under Vista, Windows 7 system, please refer to related documents.
1/15 FAQ