02 cn34042en33gln0 troubleshooting tools dx200docshare01.docshare.tips/files/30106/301061423.pdf ·...

51
1 © Nokia Siemens Networks CN34042EN33GLN0 Troubleshooting Tools in DX200 Platform

Upload: dangque

Post on 08-Feb-2018

238 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

1 © Nokia Siemens Networks CN34042EN33GLN0

Troubleshooting Tools in DX200 Platform

Page 2: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

2 © Nokia Siemens Networks CN34042EN33GLN0

Objective

After this module, the student should know:

The SCN troubleshooting tools available in the DX200 platform How to use QA Logging macro for first phase data collection

Page 3: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

3 © Nokia Siemens Networks CN34042EN33GLN0

REPORT TO THE USER

SUPER-VISION

SYSTEM

FAULTLOCATINGSYSTEM

RECOVERYSYSTEM

ALARMSYSTEM

Maintenance System

Page 4: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

4 © Nokia Siemens Networks CN34042EN33GLN0

ZA ... ALARM SYSTEM ADMINISTRATION

ZAB BLOCKED ALARMS HANDLINGZAC ALARM CANCELLINGZAE ERROR RATIO COUNTER HANDLINGZAH ALARM HISTORY HANDLINGZAL LAMP PANEL HANDLINGZAO ALARM OPERATING INSTRUCTION HANDLINGZAP ALARM PARAMETERS HANDLINGZAR ALARM SYSTEM RULEBASE HANDLINGZAT ALARM PRINTING HANDLING

Alarm system user interface

Page 5: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

5 © Nokia Siemens Networks CN34042EN33GLN0

Notices* DisturbancesNotices and Disturbances are additional information about the situation in the exchange. Notices and disturbances do not require actions from the user. * One star alarmsShould be fixed during normal maintenance hours.** Two star alarmsShould be fixed as soon as possible.*** Three star alarmsIndicate a serious situation and require immediate action.

Five Alarm Classes

Page 6: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

6 © Nokia Siemens Networks CN34042EN33GLN0

AHP

AHO

t

Alarm

Alarm

Alarm

Alarm

Alarm

No alarm

5 Alarms

Alarms at One Instance of Time

Page 7: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

7 © Nokia Siemens Networks CN34042EN33GLN0

MSS01 BSU-0 SWITCH 2004-08-06 15:37:51.71

** ALARM BSU-0 1B001-02 IC2_SS

(0039) 2186 CALL CONTROL ANALYSIS MISSING

02 0002 00 07 04 59 19 D0 00 00 00 00 00 00 00

MSS01 BSU-0 SWITCH 2004-08-06 15:38:45.22

** ALARM BSU-0 1B001-02 IC2_SS

(0040) 2186 CALL CONTROL ANALYSIS MISSING

02 0002 00 07 04 51 98 D0 00 00 00 00 00 00 00

MSS01 BSU-0 SWITCH 2004-08-09 11:41:13.07

** ALARM BSU AIF_SS

(0055) 3200 UNKNOWN RNC

222 03 0002

Alarm printout examples

Page 8: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

8 © Nokia Siemens Networks CN34042EN33GLN0

Alarm Print-Out

RECOVERY ACTION

SOURCE SYSTEM

ALARM OBJECTSOURCE COMPUTER

PRINT OUT TYPEOBJECT COORDINATES

ALARM TYPE

ALARM CLASS

CONSECUTIVE NUMBER

ALARM NUMBERSUPPLEMENTARY INFORMATION FIELD

ALARM NAME

SOURCE PROCESS

DATE TIME

MSS01 SIGU-0 SWITCH 2004-08-11 11:08:45.42

** ALARM SIGU-0 1B001-00 IC9_SX

(0033) 2186 CALL CONTROL ANALYSIS MISSING

03 0002 00 08 00 00 07 0E 00 00 00 00

Page 9: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

9 © Nokia Siemens Networks CN34042EN33GLN0

ZUD ... DIAGNOSTICS HANDLING

ZUDU START UNIT TEST/PARTIAL UNIT TESTZUDD START I/O DEVICE TESTZUDI INTERROGATE PARTIAL UNIT TESTSZUDL LIST FAULTY UNITS/PROCESSOR UNITSZUDQ INTERROGATE CURRENT TESTSZUDS STOP CURRENT TEST

Diagnostic MML

Page 10: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

10 © Nokia Siemens Networks CN34042EN33GLN0

MSCi MSS01 2004-09-09 16:51:28

DIAGNOSTIC REPORT

CLAB-4 1B001-06

PARTIAL DIAGNOSIS CLAB

DIAGNOSTIC PROGRAM 005F

DIAGNOSIS 3998

3998 DIAGNOSIS EXECUTED - UNIT NOT OK

Diagnostic Printout Example

Page 11: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

11 © Nokia Siemens Networks CN34042EN33GLN0

Logical fileLogical fileRead / write

ReadRead

DATA

Why Logical File?

Logical files buffer data between a network element and the end-user.

This is a good way to connect multiple users with only one source.

ALL I/O devices are hidden from the application. Therefore, it does not matter whether they are available or out of line.

Page 12: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

12 © Nokia Siemens Networks CN34042EN33GLN0

DIAGNOS An output logical file for all hardware diagnostic programs. Receives detailed data from the ongoing test and the results

GSMME1PR A GSM specific report file All currently active subscriber trace information is available via this logical file

OBSFAILA Collects failed call information from call control software when observation is active

Logical files used in troubleshooting

Page 13: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

13 © Nokia Siemens Networks CN34042EN33GLN0

Output Clear Codes reporting

ZTUT:CLR;

LOADING PROGRAM VERSION 14.17-0

SIGNALLING RING SPEECH CLEAR CODE0 0 235 000H NORMAL END OF THE CALL 1 3 1 005H B-SUBSCRIBER BUSY 2 0 0 00DH CALL TERMINATED BY OPER

22 7 1 015H NORMAL UNSPECIFIED 0 0 1 024H MAX DUR OF CALL EXCEEDED 1 0 0 304H B-LINE OUT OF SERVICE

89 0 0 30AH A ONHOOK DURING SET UP 51 143 0 30BH A ONHOOK DUR_WAIT ANSWER 1 0 0 603H NO RESPONSE FROM CO-PROC 4 0 0 706H CALL INTER REG ANALYSIS 3 0 0 80FH CIRCUIT CONGESTION

491 0 0 812H MAP FAILURE 2 1 1 B13H RADIO IF FAILURE

END OF REPORT

Page 14: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

14 © Nokia Siemens Networks CN34042EN33GLN0

Clear Code groups

Clear codes has been divided into four main classes:

000H - 3FFH: normal clearing400H - 7FFH: internal congestion800H - BFFH: external congestion C00H - FFFH: subscriber errors

The first main class 'normal clearing' (000H – 3FFH) consists of clear codes which have not been caused by an error in the exchange or by subscriber error, but which nevertheless leads to clearing of a call or to an interruption in call set-up.The second main class, 'internal congestion' (400H - 7FFH) consists of cases in which a call or call set-up is interrupted because of an error in the exchange. This group contains clear codes related mainly to file management and to communication between program blocks and different units of the exchange.The third main class, 'external congestion' (800H -BFFH) includes all the cases in which a call or call set-up is interrupted because of an error outside the exchange. This group consists mainly of clear codes related to inter-exchange signalling.The fourth main class, 'subscriber error' (C00H - FFFH) includes the cases in which a call or call set-up is interrupted by a subscriber's error or by a failure in the subscriber's equipment or by faulty subscriber signalling

Page 15: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

15 © Nokia Siemens Networks CN34042EN33GLN0

DX 200 MSC KL 2001-10-12 16:00:35

TRAFFIC MEASUREMENT REPORT TRACGRA CGRSOURCE: STU-1 OUTPUT INTERVAL: 60 MIN SAMPLE DATE: 2001-10-12 16:00:00

NCGR CGR CRTS DIR AVECR TC(%) CC CALLS ACCEP ANSW SFAIL IFAIL EFAIL ERLANGS

ECMFAST 187 26 IN 26.0 - - 36 21 18 0 15 0 0.5 OUT 26.0 0.0 0 0 0 0 0 0 0 0.0FAXMO 191 24 IN 22.7 - - 108 58 37 0 0 50 1.0 OUT 22.7 0.0 0 46 44 37 0 0 2 0.8BSC01 310 636 IN 635.0 - - 10569 9236 6115 159 60 1114 130.3 OUT 635.0 0.0 0 6883 6550 4915 0 2 331 129.4BSC02 320 427 IN 426.0 - - 8284 7071 5000 98 40 1075 97.5 OUT 426.0 0.0 0 5451 5056 3913 2 4 389 96.5Name & Nbr. of the CGR

Circuits in CGRper direction

avg. available(WO-EX) circuits

Time (TC) and total (CC) calls congested.Calculation based on time (%) where no circuit in CGR is available during period total amount of call attempts with no circuit available

CALLS : All call attemptsACCEP: Call attempts cleared normal,

but never reached a “conversation” state

ANSW: All answered calls

SFAIL: Failed by Subscriber errorIFAIL : Failed by exchange internal errorEFAIL : Failed by trunk circuit

Circuit Group Measurements Example

Page 16: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

16 © Nokia Siemens Networks CN34042EN33GLN0

MSCi MSS01 2004-09-09 17:43:02

MSC OBSERVATION REPORT FROM STU-0

REPORTING TIME : 2004-09-09 17:43:02.61

REPORT NUMBER : 000230

TRACED IMSI : 222039900000020

TRACE REFERENCE : 00001

OMC ID :

TRACE TYPE : ALL, BASIC, UNPRIOR

TRACE TYPE USED : ALL, BASIC, UNPRIOR

START TIME : 2004-09-09 17:42:46.99

END TIME : 2004-09-09 17:43:02.15

RECORDING ENTITY : 39269000080

REPORT REASON : EVENT

INVOKING EVENT : SUBS(A)

CALL ID : 0179H-017AH-4004H-4131H-00DCH-00H-00DCH-00H

CALL START : 2004-09-09 17:42:46.99 CALL PHASE : RELEASE

SIGNALLING COMPLETE : 2004-09-09 17:42:50.98 STAT STATE : IDLE

ANSWER : 2004-09-09 17:42:53.10 CLEAR CODE : 0000H

CHARGING END : 2004-09-09 17:43:02.15 CLEAR INFO : AIF_SS 0001H 0B2EH

PAGING TIME : 1870 CLEAR PART : SUB A

EXT CLEAR CODE : 0010H SIGNALLING : MS CC

Trace example 1/3

Page 17: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

17 © Nokia Siemens Networks CN34042EN33GLN0

MGW TRACE : OK

EXTERNAL FORWARDING COUNTER : 0

CALLING NUMBER : I 392695550020

CALLED NUMBER : N 2695550018

OUT PULSED NUMBER : I 392695550018

CONNECTED NUMBER : I 392695550018

ROAMING NUMBER : N 2698000163

ADDRESS NUMBER : U 2695550018

IP TRUNK : NOT USED IP TRUNK

OBJECT SUBSCRIBER A (TRACED) SUBSCRIBER B

IMSI : 222039900000020 222039900000018

IMEI :

Trace example 2/3

Page 18: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

18 © Nokia Siemens Networks CN34042EN33GLN0

Trace example 3/3

RADIO SYSTEM : UMTS UMTS

CGR/BSC/PCM-TSL : / / - / / -

MCC/MNC : 222 /03 222 /03

LAC/CI/CELL BAND : 00932/00932/ 00932/00932/

RNC ID : 00002 00002

MGW INDEX : 0 0

MGW NAME : MGW2 MGW2

BNC CHAR : AAL2 AAL2

UPD INDEX/NAME : 0 /UPD0 0 /UPD0

TDM TERMID :

CHANNEL RATE : FR / HFR1 / FR / HFR1 /

SPEECH VERSION : FR3 FR3

PRIORITY : 3 3

MS CLASSMARK :

ECHO CANCELLING PARAMETERS

RECEIVED IEC / OEC : INCLUDED / INCLUDED

SENT IEC / OEC : INCLUDED / INCLUDED

END OF REPORT

Page 19: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

19 © Nokia Siemens Networks CN34042EN33GLN0

2

CATEGORY Test mobile created in the HLR

Test digit analysis tree with analysisorTest attribute analysis created

TEST ACTIVITYYCH-MML

START TESTYCS-MML

TEST CATEGORY 4

Testing number analysis

Page 20: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

20 © Nokia Siemens Networks CN34042EN33GLN0

CATEGORY Test mobile created in the HLR

TEST HUNTINGYC-MML

START TESTYCS-MML

TEST CATEGORY 4

TE TIME SLOT IN TEST STATE

Testing number analysis

Page 21: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

21 © Nokia Siemens Networks CN34042EN33GLN0

X

B3 2M

Typical problem

and solution

2M

X

Loop Transmission

Page 22: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

22 © Nokia Siemens Networks CN34042EN33GLN0

MMDIREActive BLCODE

LFILES

ASWDIRMMLLOG 20040912.00

20040911.0020040910.0020040909.00

MML LOG

Page 23: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

23 © Nokia Siemens Networks CN34042EN33GLN0

MML command log

ZIGO:2006-01-26,10-00,2006-01-26,10-30:USERID=SYSTEM::;

LOADING PROGRAM VERSION 4.8-0/* MSS_880091 MSCi SYSTEM 2006-01-26 10:09:42 */AHP::NR=:2006-01-26,09-00-00:;/* 3 SESSION=00008 USERID=SYSTEM 2006-01-26 10:03:20 *//* 4 AHP::NR=:2006-01-26,09-00-00:; *//* 4c COMMAND EXECUTED *//* 4c SESSION=00008 USERID=SYSTEM 2006-01-26 10:03:20 */USI:COMP;/* 3 SESSION=00008 USERID=SYSTEM 2006-01-26 10:07:44 *//* 4 USI:COMP; *//* 4c COMMAND EXECUTED *//* 4c SESSION=00008 USERID=SYSTEM 2006-01-26 10:07:44 */NEL;/* 3 SESSION=00008 USERID=SYSTEM 2006-01-26 10:07:50 *//* 4 NEL; *//* 4c COMMAND EXECUTED *//* 4c SESSION=00008 USERID=SYSTEM 2006-01-26 10:07:50 */IGO:2006-01-26,10-00,2006-01-26,10-30:USERID=SYSTEM::;/* 3 SESSION=00008 USERID=SYSTEM 2006-01-26 10:09:42 */COMMAND EXECUTED

Page 24: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

24 © Nokia Siemens Networks CN34042EN33GLN0

DX200 SERVICE TERMINAL MAIN LEVEL COMMANDS:

? ..... MENU / HELP I .. .. GENERAL INFORMATIONA ..... ANALYZER L ..... EXTENSION HANDLINGB ..... DEFINE ENVIRONMENT O ..... OPERATING SYSTEM COMMANDSC ..... COMMAND LANGUAGE UTILITIES R ..... REMOTE DEBUGGER HANDLINGD ..... MEMORY AND I/O HANDLING S ..... SYSTEM MONITORING COMMANDSE ..... EXIT DEBUGGER SESSION T ..... TERMINAL HANDLING

EXTENSIONS:

G ..... COMPUTER LOG HANDLER (DEF) U ..... RECOVERY DEBUGGER

M ..... MASS MEMORY HANDLING

INITIAL NAME: 00BE 0000 00 CURRENT NAME: 00BE 0000 00

00-MAN>

Service Terminal

Page 25: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

25 © Nokia Siemens Networks CN34042EN33GLN0

BSUBSUCMCM

CCSU / SIGU

CCSU / SIGU

HLR

VLR

PSTN

Traffic Flow in the MSC/MSS

Page 26: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

26 © Nokia Siemens Networks CN34042EN33GLN0

QA LoggingFirst phase data collection macro

Page 27: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

27 © Nokia Siemens Networks CN34042EN33GLN0

QA Logging – Introduction

When abnormal situation occurs in customer networkProblem reported to NSNSome obligatory information need to be collected for troubleshooting

In the first phase of troubleshooting, we required information about: Detailed case description SW versions Generic configuration data from involved network elements

Based on collected information technical support engineer should be able to determine the nature of the problem Configuration error SW defect HW failure

Page 28: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

28 © Nokia Siemens Networks CN34042EN33GLN0

QA Logging – Faster troubleshooting

Provide essential information to get troubleshooting immediately to right direction without any extra delays due to unnecessary info requests

In later troubleshooting phase some extra SW monitoring or configuration data might be needed, which is requested by a new information request.

Page 29: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

29 © Nokia Siemens Networks CN34042EN33GLN0

QA Logging – Description

QA logging macro is made to execute this first phase data collection

Macro is divided in two parts: questioning and data collection.

Questioning part is first executed to define the case description Predefined problem areas (Call failures, unit restarts, site connectivity,…) If user cannot immediately answer to some questions, answers should be found

out before continuing to avoid unnecessary info requests. Generic data collection for unidentified problems

Data collection based on given answers.

Page 30: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

30 © Nokia Siemens Networks CN34042EN33GLN0

Preliminary actions

Use always latest QAL version available, getting by send e-mail:To : [email protected]: QAL_UPDATE

QA logging macro is made for HIT toolHIT must be installed in user’s Windows PCHIT 2.10-x or higher is requiredDevice connection for all involved network elements

need to be defined in HIT

QA logging include the following files which must be included in same local directory in user’s PC QAL_START.hit (macro file for execution) QAL_FUNC.tel ( function library) QAL.ini (logic for questioning phase)

QAL 2.1-3 MSS.zip

Page 31: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

31 © Nokia Siemens Networks CN34042EN33GLN0

Execution

Start HIT tools and define device connection, if not exist yet Open QAL_START.HIT and press start button

Page 32: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

32 © Nokia Siemens Networks CN34042EN33GLN0

Select Problem area to start questioning phase

Questioning based on selected problem area, answer correctly to all questions

Execution

Full data collection is not for first phase data collection. It should be run only when requested by NSN.

Page 33: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

33 © Nokia Siemens Networks CN34042EN33GLN0

Execution

Select execution mode, single or multi-tasking mode

Select network element for data collection , execution start after devices are selected

Page 34: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

34 © Nokia Siemens Networks CN34042EN33GLN0

Results

Results are collected in case specific directories under execution directory. There are subdirectories for all NE from where data was collected Directory format: /QAL_<date>_<time>/

/QAL_<date>_<time>/<element name>/

Log files must be zipped to decrease size. Usually less than 1Mbits even several elements included.

Example: /QAL_2009-12-02_13-44-27/…QAL_2009-12-02_13-44-27.ZIP

NOTE! It is mandatory to include QA logging results in every problem case before it’s escalated to level 3 in Resolve.

Page 35: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

35 © Nokia Siemens Networks CN34042EN33GLN0

QA_LOGGING creates unique case specific directory under execution directory. Under case directory there are subdirectories for all network elements from where data was collected.

Result

Page 36: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

36 © Nokia Siemens Networks CN34042EN33GLN0

Appendix

Page 37: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

37 © Nokia Siemens Networks CN34042EN33GLN0

Find your VTP/VDU

ZQNS;

MSCi MSS_880091 2006-05-20 14:28:31 PAGE 1

SYSTEM USERNAME USER USER MML SESSIONSYSTEM I/O-DEVICE NUMBER

990095 MSC02 SYSTEM 880091 MSC02 OMU-VTP17 TU 00602SYSTEM 880091 MSC02 OMU-VTP19 QN 00612SYSTEM 880091 MSC02 OMU-VTP21 US 00607

COMMAND EXECUTED

Page 38: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

38 © Nokia Siemens Networks CN34042EN33GLN0

Connect DIAGNOS logical file to your VTP

If you want the diagnostics output to appear on you screen then connect logical file to your VTP/VDU

ZIIS:,OMU:DIAGNOS,::DEV=VTP-19:;

LOGICAL FILE MODIFIED:

SYSTEM = MSS_880091 UNIT = OMU

PAGE 1LOG LOG SPARE PHYSICAL OBJ SYSTEM UNIT DEVICE/FILE FILE FILE FILE IND NAME NAME LOGICALNBR NAME & CLASS MODE NAME FILE

5B DIAGNOS P 1 MSS_880091 OMU LPT-12 MSS_880091 OMU VDU-53 MSS_880091 OMU VTP-19

Page 39: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

39 © Nokia Siemens Networks CN34042EN33GLN0

Start diagnostics

Change Computer Unit state to TE-EX…

ZUSC:SIGU,2:TE;

Then start diagnostics…

ZUDU:SIGU,2;

Page 40: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

40 © Nokia Siemens Networks CN34042EN33GLN0

Diagnostics output

Press enter several times to get partial and total diagnostics report on your screen

MSCi MSS_880091 2006-01-26 11:55:33

DIAGNOSTIC REPORT

SIGU-2 1B002-00

PARTIAL DIAGNOSIS TOTALDIAGNOSTIC PROGRAM 0000DIAGNOSIS 3999

3999 TOTAL DIAGNOSIS EXECUTED - UNIT OK

END OF REPORT

If you didn’t connect the logical file to your VTP/VDU then you can always check diagnostics result from history (see next page)…

Page 41: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

41 © Nokia Siemens Networks CN34042EN33GLN0

Diagnostics history

ZUDH:SIGU,2::;

MSCi MSS_880091 2006-01-26 11:35:43

DIAGNOSTIC REPORT HISTORYUNIT = SIGU-2 REPORT-CLASS = ALL DATE = 2006-01-26 TIME = 00:00:00

MSCi MSS_880091 2006-01-26 10:42:11PARTIAL DIAGNOSIS EXECUTED SIGU-2 POWER

MSCi MSS_880091 2006-01-26 10:42:35PARTIAL DIAGNOSIS EXECUTED SIGU-2 CPU

MSCi MSS_880091 2006-01-26 10:42:35PARTIAL DIAGNOSIS EXECUTED SIGU-2 RAM

MSCi MSS_880091 2006-01-26 10:42:40PARTIAL DIAGNOSIS EXECUTED SIGU-2 SYSB

MSCi MSS_880091 2006-01-26 10:42:40

DIAGNOSTIC REPORT

SIGU-2

PARTIAL DIAGNOSIS TOTALDIAGNOSTIC PROGRAM 0000DIAGNOSIS 3999

3999 TOTAL DIAGNOSIS EXECUTED - UNIT OK

END OF REPORT

Page 42: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

42 © Nokia Siemens Networks CN34042EN33GLN0

Set trace on Nokia Clear Code

ZIIS:,OMU:OBSFAILA,::DEV=VTP-19:;ZTOF:S,:005:; (trace for B-Subscriber busy: 0005H)

SIGNALLING COMPLETE : 2006-01-26 16:11:08.21 STAT STATE : IDLEANSWER : CLEAR CODE : 0005HCHARGING END : CLEAR INFO : AIF_SS 0003H 0B2FHPAGING TIME : 1280 CLEAR PART : SUB BEXT CLEAR CODE : 0011H SIGNALLING : MS CC

Check details in NED…

Clear Code

Additional information fields

Page 43: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

43 © Nokia Siemens Networks CN34042EN33GLN0

Connect logical file OBSFAILA to physical file on disk1. Create new directory for the physical file on both disks

ZIWL:,OMU:WSB,DEF::PHYFILES,,,XY:;

2. Create physical file (OBSFAILALOG.TXT) on both disks

ZIWC:,OMU:WSB,DEF:PHYFILES,:OBSFAILALOG,TXT,999999,XY:;

(One CC observation needs about 2490 bytes. File size "999999" gives space for about 400 CC observations)

3. Link physical (as a ring file) file to logical file (OBSFAILA)

ZIII:,OMU:OBSFAILA,B:,PHYFILES,:OBSFAILALOG,TXT,,RF:;

4. Set logical file to write to both disks

ZIIS:,OMU:OBSFAILA,::DEV=WDU-SB:;

5. Set path to read file from system disk

ZIWY:S:UNIT=OMU,PATH=-PHYFILES,DRIVE=WDU-S;

6. Output physical file in ASCII format

ZIBT:WDU,S,OBSFAILALOG,TXT,,,,A,;

Page 44: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

44 © Nokia Siemens Networks CN34042EN33GLN0

Fast Subscriber Trace for ongoing calls onlyMCJ:IMSI=460100000000104::TYPE=D:;

MSCi MSS04 2008-05-20 15:05:45

SEARCH CALL PATH

LEG TYPE : ORIGINAL LEG CALL ID : 0004H-0000000BH-4004H-4131H-0003H-00H-4131H-0005H-00HORIG CALL ID :CALL START : 2008-05-20 15:05:24 TARGET : MSC /SCALLFSIGN COMP : 2008-05-20 15:05:28 CALL TYPE : INTERNAL ANSWER : 2008-05-20 15:05:29 CALL PHASE : CONVERSATION CHAR END : ....-..-.. ..:..:.. STAT STATE : AB SEIZEDLAST MESSAGE : 2008-05-20 15:05:29 D5C8CLEAR CODE : UNIT ID : BSU -001

CALLING NUMBER : I 8622301000006 CALLED NUMBER : I 8612301000104 OUTPULSED NUMBER : I 8612301000104 CONNECTED NUMBER : I 8612301000104 FORWARDED TO : ROAMING NUMBER : N 42300100006 ADDRESS NUMBER : U 12301000104

OBJECT SUBSCRIBER A SUBSCRIBER BTRACING REF/TYPE : / 00001/ALL EVENTSIMSI : 460200000000006 460100000000104 IMEI : RADIO SYSTEM : GSM GSMCGR/PCM-TSL/STATE : 00531/2048-04/R 00531/2048-05/RBICC CIRCUITNET :

SPC : CIC :

MGW : VMGW31 VMGW31BNC CHAR : TDM TDMTDMTERMID : 00001-04 00001-05TERMID :

Page 45: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

45 © Nokia Siemens Networks CN34042EN33GLN0

Fast Subscriber Trace for ongoing calls only(Cont.)CNTL TYPE/INDEX : BSU /00001 BSU /00001MCC/MNC : 460 /30 460 /30 BSC/LAC/CI : 00003/00300/00301 00003/00300/00301RNC : NAME/INTRA CI : BTS301 /00000 BTS301 /00000LOCATION NUMBER : USED CODEC : G711 A G711 A CHANNEL RATE : FR /FR /FR FRP /FR /FRSPEECH VERSION : FR1 FR1LSA : USED CHANNEL CODINGS : PRIOR/CATEG : /ORDINARY /ORDINARYMS CLASSMARK : 3 3 MS UMTS CAPABILITY : IN CATEGORY KEY : CAMEL CALL ADDRESS : CAMEL REF NUMBER : CTM TT CAPABLE : NO NOTEST CALL CATEGORY : PAGING TIME : 01170 msBACK/FORW : / HO LINK : ROAM LINK : 0005INTERCONNECTING TDM : - -ANCHOR IC TDM : -

ECHO CANCELLING PARAMETERSRECEIVED IEC / OEC : INCLUDED / INCLUDEDSENT IEC / OEC : INCLUDED / INCLUDEDIEC STATE / OEC STATE : /

ICC-PID 4131H/0134H/0003H/00H SSI-PID / / / SSO-PID / / / AIFI-PID 4131H/0132H/002EH/00H AIFO-PID 4131H/0132H/002FH/00H OCC-PID 4131H/0136H/0005H/00H CFO-PID / / / CTH1-PID / / / CTH2-PID / / /

COMMAND EXECUTED

Page 46: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

46 © Nokia Siemens Networks CN34042EN33GLN0

Detailed Subscriber TraceZIIS:,OMU:GSMME1PR,::DEV=VTP-19:;ZMWC:MSISDN=460100000000104:REF=1,:;

MSCi MSS04 2008-05-20 15:14:36MSC OBSERVATION REPORT FROM OMU-0

REPORTING TIME : 2008-05-20 15:14:36.97

REPORT NUMBER : 000029RECORDING ENTITY : 8642300100

REPORT REASON : EVENTINVOKING EVENT : FAIL

CALL ID : 0008H-00000010H-4004H-4131H-0006H-00H-4131H-0009H-00H

CALL START : 2008-05-20 15:14:24.22 CALL PHASE : RELEASESIGNALLING COMPLETE : STAT STATE : IDLE

ANSWER : CLEAR CODE : 0874HCHARGING END : CLEAR INFO : URQPRB 0E01H 0000H

PAGING TIME : CLEAR PART : SYSTEMEXT CLEAR CODE : SIGNALLING : -

MGW TRACE : OK

EXTERNAL FORWARDING COUNTER : 0

Page 47: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

47 © Nokia Siemens Networks CN34042EN33GLN0

CALLING NUMBER : I 8612301000104 CALLED NUMBER : N 1022301000006 OUT PULSED NUMBER : CONNECTED NUMBER : ROAMING NUMBER : ADDRESS NUMBER : U 1022301000006 BIWF ADDRESS A : 8632300300

DESTINATION: 14

SUBDEST ROUTE RESULT38 2100 0874H

OBJECT SUBSCRIBER A SUBSCRIBER B IMSI : 460100000000104 IMEI : RADIO SYSTEM : GSM -CGR/BSC/PCM-TSL : 0531/0003/2048-08 / / -MCC/MNC : 460 /30 / LAC/CI/CELL BAND : 00300/00301/ / /MGW INDEX : 0MGW NAME : VMGW31BNC CHAR : TDMTDM TERMID : 1-8 NORMAL CTX ID : 524694USED CODEC : G711 ACHANNEL RATE : FRP / FR / FR / / SPEECH VERSION : FR1 PRIORITY : MS CLASSMARK : 3 DUAL BANDCTM TT CAPABILITY : NO

END OF REPORT

Page 48: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

48 © Nokia Siemens Networks CN34042EN33GLN0

Test calls

Test calls are done for two purposes:

test analysis - to test defined analyses

test hunting - to force-route a call on a certain circuit that is put in the TE state.

Test calls

Test analyses Test hunting (forced routing)

Page 49: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

49 © Nokia Siemens Networks CN34042EN33GLN0

Flow of test calls

Test origin

matched

Normal cellTest cell

Test mobile

Test phone

Normal cell

Not test mobileTest mobile or

not test mobile

Normal trunk

Test trunk

Normal trunk

Not test phone

Test phone or

not test phone

Test case

definition

A) Test analysis

B) Test hunting

C) Test analysis and

Test Hunting

Normal traffic

Own MSCExchange

No

Yes

0 test origin = normal cell

1 test origin = normal incoming circuit

2 test origin = test cell

3 test origin = incoming test circuit

4 test origin = test origin received in subscriber signalling

5 test origin = test origin received in incoming circuit signalling

4 02

1

3

5

Page 50: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

50 © Nokia Siemens Networks CN34042EN33GLN0

BSU

CM

CCSU

24

13215

33215

1) Check CM state – ZUSI:CM,:; e.g. CM,0 WO-EX

2) Connect service terminal - ZDDS:CM, 0:; ( 1 in case CM,1 is working).

3) ZOQA:W,C=32154) ZOQ:70

Message Monitoring

Page 51: 02 CN34042EN33GLN0 Troubleshooting tools DX200docshare01.docshare.tips/files/30106/301061423.pdf · The SCN troubleshooting tools available in the DX200 platform ... Diagnostic MML

51 © Nokia Siemens Networks CN34042EN33GLN0

Monitoring attribute resultsAnalysis tree Charging origin Analysed digits

Analysis type TMR TON

Type of Number in Messages:

not_exist 0not_allowed 1unknown 2reserved 3unknown_numb 4international 5national 6net_specific 7subscriber 8abbreviated 9dedicated_pad A

Numbering Plan in Messages:

not_exist 0not_allowed 1unknown 2reserved 3unknown_plan 4isdn_teleph 5data 6telex 7nation_stand 8private 9

TMR255 do_not_care_c Do not care 10 khz3_1_c 3.1 kHz audio 9 kb64_pre_c 64 kbit/s preferred 8 kb64_unres_c 64 kbit/s unrestricted 6 kb1920_unres_c Reserved for 1920 kbit/s unrestricted 5 kb1536_unres_c Reserved for 1536 kbit/s unrestricted 4 speech_c Speech 3 kb384_unres_c Reserved for 384 kbit/s unrestricted 2 kb2_64_unres_c Reserved for 2 x 64 kbit/s unrestricted 1 sv_1_sv_2_c Alternate 64 kbit/s unrestricted (service 1)/ speech (service 2) 0 sv_2_sv_1_c Alternate speech (service 2)/ 64 kbit/s unrestricted (service 1)

MONITORING TIME: 2004-03-28 11:22:27.74

RECEIVED BY: 0070 0000 00

MONITORED MESSAGE: 0053 4532 0134 0113 00 19 0000 3215 0041

00 00 02 00 00 00 00 00 00 00 FF FF FF 06 04 09 0A 09 09 03 06 00 00 00 00

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

00 00 00 00 00 FF 04 06 00 64 00 00 00 00 00 00 00