01-ehs servers and systems
TRANSCRIPT
-
8/10/2019 01-EHS Servers and Systems
1/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 1 of 12 Saved on :12/29/201411:59 PM
EHSGENERATION SERVERS /SYSTEM TESTS
CHPPRODCUTION
CHQQUALITY AND CHSSANDBOX
-
8/10/2019 01-EHS Servers and Systems
2/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 2 of 12 Saved on :12/29/201411:59 PM
TABLE OF CONTENTS
1.
TESTING SERVICES ...................................................................................................................................................... 3
1.1. WWISERVICE 31.2. GLM(LABEL)SERVICE 41.3. EXPERTSERVICE 4
2. TESTING REPORT CREATION ..................................................................................................................................... 5
2.1. SDSCREATION 5
3. TESTING REPORT SHIPPING ....................................................................................................................................... 7
3.1. SDSMANUAL REPORT SHIPPING 7
4. TESTING LABEL PRINTING ........................................................................................................................................ 10
4.1.
LABEL PRINTING 10
5. TESTING EXPERT RULES ........................................................................................................................................... 11
5.1. EXPERT RULES 11
-
8/10/2019 01-EHS Servers and Systems
3/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 3 of 12 Saved on :12/29/201411:59 PM
1. TESTING SERVICES
1.1. WWISERVICE
Functional Requirement: Used to generate Safety Data Sheets and for report shipping.
Transaction: CGSADM
Detailed Testing Steps:1. Check SM59 entry EHS_WWI_MSDS
2. Click the test connection icon
3. A succesful test looks like this
-
8/10/2019 01-EHS Servers and Systems
4/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 4 of 12 Saved on :12/29/201411:59 PM
Test Status:
1.2. GLM(LABEL)SERVICE
Functional Requirement: Used for printing labels
Detailed Configuration Steps:1. Check SM59 entry EHS_WWI_MSDS
2. Test Connection
Test Status:
1.3. EXPERTSERVICE
Functional Requirement: Executing Expert rules and populating the EHS property tree with the appropriate data.
Detailed Configuration Steps:
1. Check SM59 entry EHS_EXPERT
-
8/10/2019 01-EHS Servers and Systems
5/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 5 of 12 Saved on :12/29/201411:59 PM
2. Connection Test
Test Status:
2. TESTINGREPORT CREATION
2.1. SDSCREATION
Functional Requirement: Create a report so that it is saved in the report information system
Transaction: CG02
Detailed Testing Steps:1. Go to transaction CG02 and find specification 000000019008
2. Create Report
-
8/10/2019 01-EHS Servers and Systems
6/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 6 of 12 Saved on :12/29/201411:59 PM
3. Generation Variant EU-GB-SDS
4. Message at the bottom of the screen should show
5. The WWI monitor (CG5Z) will show your username and the status should display completed
6. Look at the report information system
-
8/10/2019 01-EHS Servers and Systems
7/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 7 of 12 Saved on :12/29/201411:59 PM
7. It should display a released report as shown.
8. Clicking on the report icon will bring the finished report up for viewing.
Test Status:
3. TESTINGREPORT SHIPPING
3.1. SDSMANUAL REPORT SHIPPING
Functional Requirement: Create a report so that it is saved in the report information system
Transaction: CG02
Detailed Testing Steps:1. Go to transaction CG02 and find specification 000000019008
2. Look at the report information system
-
8/10/2019 01-EHS Servers and Systems
8/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 8 of 12 Saved on :12/29/201411:59 PM
3. It should display a released report as shown.
4. Go to the menu item
5. Use material number 4071108
6. Use report recipient 590696
7. Use the Process parameter immediately and communication type INT
-
8/10/2019 01-EHS Servers and Systems
9/12
-
8/10/2019 01-EHS Servers and Systems
10/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 10 of 12 Saved on :12/29/201411:59 PM
4. TESTING LABEL PRINTING
4.1. LABEL PRINTING
Functional Requirement: Printing labels requires a Synchronous server connection, which is different than thenormal report generation that uses a Asynchronous connection.
Transaction: ZLABEL
Detailed Testing Steps:1. Go to transaction ZLABEL and use the material scenario
2. Click on the Label tree icon
3. Information should look like thismeaning the material has been set up for label printing
-
8/10/2019 01-EHS Servers and Systems
11/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 11 of 12 Saved on :12/29/201411:59 PM
4. Double click on SHIPPING LABEL 3 x 5 (General) and then hit the eyeglasses to activate previewing the label.The label will display in microsoft word.
Test Status:
5. TESTING EXPERT RULES
5.1. EXPERT RULES
Functional Requirement: Expert rules are a way for us to automate classification and enables consistency ofdata througout our system.
Transaction: CG02
Detailed Testing Steps:
1. Go to transaction CG02 and find specification 000000019008
2. Highlight the specification and go to the menu item as shown
3. Choose the expert rule ZEXP_COMP EHS-Exp: Standard Composition
4. Hit the green check
-
8/10/2019 01-EHS Servers and Systems
12/12
Systems Unit Testing
Environmental Health & Safety
01-EHS Servers and Systems.docx Page 12 of 12 Saved on :12/29/201411:59 PM
5. The results should look like this