your power solution - kejuruteraan mega acp …€¦ · your power solution ... alternator model...

4
YOUR POWER SOLUTION KEJURUTERAAN MEGA ACP SDN BHD Co. Reg:856023-D | Gst No:000755671040

Upload: ngonga

Post on 30-Aug-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

YOUR POWER SOLUTION

KEJURUTERAAN MEGA ACP SDN BHD Co. Reg:856023-D | Gst No:000755671040

Cummins Generator Cummins engine generators are very consistent in their efficiency as well as low operating cost and easy

maintenance. They are produced in accordance with ISO8528, ISO3046, IEC34 and other international

standards. Cummins engine generators are the optimum choice for use not only in standby field but also

in prime field. Technical Data

Power (KW) Engine Model Alternator Model No. of cyclinders Bore X Stroke 100% load fuel Overall Dimension Net Weight

Model Prime Standby CUMMINS STAMFORD & configuraƟon (mm) Displacement (L) consumpƟon

(L x W x H) (mm) (kg)

(g/kw*h)

RC-16GF 16 18 4B3.9-G2 BC1184E 4L 102/120 3.9 210 1700X730X1400 700

RC-20GF 20 22 4B3.9-G2 BC1184F 4L 102/120 3.9 210 1700X730X1400 700

RC-25GF 25 28 4BT3.9-G2 BC1184G 4L 102/120 3.9 210 1800X760X1400 800

RC-30GF 30 32 4BT3.9-G2 BC1184H 4L 102/120 3.9 210 1800X760X1400 800

RC-40GF 40 45 4BTA3.9-G2 UC1224D 4L 102/120 3.9 210 1850X730X1400 900

RC-45GF 45 50 4BTA3.9-G2 UC1224E 4L 102/120 3.9 210 1850X730X1400 900

RC-50GF 50 55 6BT5.9-G2 UC1224F 6L 102/120 5.9 210 2200X830X1400 1100

RC-80GF 80 88 6BT5.9-G2 UC1274C 6L 102/120 5.9 210 2200X830X1400 1100

RC-90GF 90 100 6BTA5.9-G2 UC1274D 6L 102/120 5.9 210 2200X830X1400 1200

RC-100GF 100 110 6BTAA5.9-G2 UC1274E 6L 102/120 5.9 210 2300X830X1400 1300

RC-120GF 120 140 6CTA8.3-G2 UC1274F 6L 114/135 8.3 210 2450X850X1500 1700

RC-140GF 140 150 6CTA8.3-G2 UC1274G 6L 114/135 8.3 210 2450X850X1500 1700

RC-160GF 160 180 6CTAA8.3-G2 UC1274H 6L 114/135 8.3 210 2550X950X1600 1800

RC-200GF 200 220 6LTAA8.9-G2 UCD1274K 6L 114/145 8.9 210 2550X950X1650 2000

RC-250GF 250 280 MTAA11-G3 HC1444ES 6L 125/147 10.8 210 3050X1150X1700 2800

RC-280GF 280 300 NTA855-G2A HC1444E 6L 140/152 14 210 3100X1000X1700 3100

RC-300GF 300 320 NTAA855-G7A HC1444FS 6L 140/152 14 210 3200X1100X1900 3200

RC-320GF 320 360 NTAA855-G7A HC1444F 6L 140/152 14 210 3200X1100X1900 3200

RC-360GF 360 400 KTA19-G3 HC1544C 6L 159/159 19 208 3450X1250X2100 4200

RC-400GF 400 440 KTA19-G4 HC1544C 6L 159/159 19 208 3450X1250X2100 4200

RC-450GF 450 500 KTAA19-G5 HC1544E 6L 159/159 19 208 3650X1250X2300 4500

RC-500GF 500 550 KTAA19-G6A HC1544FS 6L 159/159 19 208 3650X1420X2300 4300

RC-600GF 600 660 KTA38-G2 LV1634B 12V 159/159 38 208 4400X1700X2400 7600

RC-720GF 720 800 KTA38-G2A LV1634D 12V 159/159 38 208 4400X1700X2400 7800

RC-800GF 800 880 KTA38-G5 LV1634E 12V 159/159 38 208 4500X1900X2400 8000

RC-900GF 900 1000 KTA38-G9 LV1634F 12V 159/159 38 208 4600X2100X2400 9400

RC-1000GF 1000 1100 KTA50-G3 LV1634G 16V 159/159 50 208 5200X2000X2400 10000

NOTE: The above gensets are based on 50HZ, 1500RPM, rated voltage are 400/230V. Power factor is 0.8 and the connecƟng method is 3 phase and 4 wire.60HZ gensets can be supplied according to the customers' requirements. The above technical data can be subject to change without noƟce due to conƟnuous improvements by manufacturers

Original Cummins Generator Technical Data

Power (KW) Engine Model Alternator Model No. of cyclinders Bore X Stroke 100% load fuel Overall Dimension Net Weight

Model Prime Standby CUMMINS (Original) STAMFORD

& configuration (mm) Displacement (L) consumption (L x W x H) (mm) (kg)

(g/kw*h)

RC2-200GF 200 220 QSL9-G5(UK) UCDI274K 6.L 114/145 8.8 199 3200x1100x2000 2200

RC2-240GF 240 260 QSL9-G5(UK) HCI444D 6.L 114/145 8.8 199 3200x1100x2000 2500

RC2-360GF 360 400 QSX15-G8(USA) HCI544C 6.L 137/169 15 198 3500x1500x2100 4250

RC2-400GF 400 440 QSX15-G8(USA) HCI544D 6.L 137/169 15 198 3500x1500x2100 4250

RC2-500GF 500 550 VTA28-G5(India) HCI544FS 12.V 140/152 28 213 4000x1500x2100 6000

RC2-600GF 600 660 VTA28-G5(India) LVI634B 12.V 140/152 28 226 4100x1500x2000 6700

RC2-640GF 640 720 QSK23-G3(Japan) LVI634C 6.L 170/170 23.15 195 4600x1550x2100 7000

RC2-720GF 720 800 QST30-G3(USA) LVI634D 12.V 140/165 30.48 194 4300x1500x2100 7450

RC2-800GF1 800 880 QST30-G4(USA) LVI634E 12.V 140/165 30.48 194 4600x1750x2400 8000

RC2-800GF2 800 880 KTA38-G5(India) LVI634E 12.V 159/159 37.8 202 4500x1800x2300 8350

RC2-900GF 900 1000 KTA38-G9(India) LVI634F 12.V 159/159 37.8 202 4600x2100x2300 9400

RC2-1000GF 1000 1120 KTA50-G3(India) LVI634G 16.V 159/159 50.3 202 5200x2000x2300 10050

RC2-1200GF 1200 1320 KTA50-GS8(India) PI734C 16.V 159/159 50.3 205 5900x2100x2800 11000

RC2-1500GF 1500 1650 QSK60-G3(UK) PI734E 16.V 159/190 60.2 191 6200x2300x2600 15100

RC2-1600GF 1600 1800 QSK60-G4(UK) PI734F 16.V 159/190 60.2 193 6200x2300x2600 15400

NOTE: The above gensets are based on 50HZ, 1500RPM, rated voltage are 400/230V. Power factor is 0.8 and the connecƟng method is 3 phase and 4 wire. 60HZ gensets can be supplied according to the customers' requirements. The above technical data can be subject to change without noƟce due to conƟnuous improvements by manufacturers

Cummins Marine Engine Generator Cummins engine marine auxiliary generators consist of marine engine, alternator and monitoring system.The

chosen engine conforms to National Marine generator standard GB/T-13032-1991, RCB-JT01/2001 and CCS

Standard. Cummins marine engine and Stamford alternator are the standard configuration, but customers can

opt for other brand of alternators according to their requirements. Technical Data

Model Power (KW) Engine Model Alternator Model No. of

Bore X Stroke Displacement (L) 100% load fuel

Overall Dimension Net Weight (kg)

cyclinders & consumpƟon

Prime Standby CUMMINS STAMFORD configuraƟon (mm)

(g/kw*h) (L x W x H) (mm)

C-CCF30J 30 33 4BTA3.9-GM47 UCM224C 4.L 102/120 3.9 210 1600x730x1200 900

C-CCF40J 40 44 4BTA3.9-GM47 UCM224E 4.L 102/120 3.9 210 1650x730x1200 1000

C-CCF50J 50 55 6BT5.9-GM83 UCM224F 6.L 102/120 5.9 210 2000x730x1200 1100

C-CCF64J 64 70 6BT5.9-GM83 UCM274C 6.L 102/120 5.9 210 2000x730x1200 1200

C-CCF75J 75 83 6BTA5.9-GM100 UCM274D 6.L 102/120 5.9 210 2000x850x1200 1200

C-CCF90J 90 100 6CT8.3-GM115 UCM274E 6.L 114/135 8.3 210 2250x850x1400 1500

C-CCF100J 100 110 6CTA8.3-GM155 UCM274E 6.L 114/135 8.3 210 2300x850x1400 1500

C-CCF120J 120 132 6CTA8.3-GM155 UCM274G 6.L 114/135 8.3 210 2300x850x1400 1700

C-CCF140J 140 150 6LTAA8.9-GM200 UCM274H 6.L 114/145 8.9 210 2400x1000x1550 1900

C-CCF160J 160 176 6LTAA8.9-GM200 UCM274J 6.L 114/145 8.9 210 2400x1000x1550 1900

C-CCF200J 200 220 NTA855-D(M)/240 HCM434D 6.L 140/152 14 210 2800x1000x1700 3100

C-CCF250J 250 275 NTA855-D(M)/284 HCM434E 6.L 140/152 14 210 2800x1000x1700 3200

C-CCF280J 280 310 NTA855-D(M)/317 HCM434F 6.L 140/152 14 210 3000x1000x1700 3400

C-CCF300J 300 330 KTA19-D(M)/336 HCM534C 6.L 159/159 18.9 208 3150x1250x1900 4200

C-CCF350J 350 385 KTA19-D(M)/403 HCM534D 6.L 159/159 18.9 208 3150x1250x1900 4200

C-CCF400J 400 440 KTA19-D(M)/448 HCM534E 6.L 159/159 18.9 208 3150x1250x1900 4200

C-CCF500J 500 550 KT38-D(M)/560 LVM634B 12.V 159/159 37.8 208 4000x1250x2000 7400

C-CCF600J 600 660 KTA38-D(M)/664 LVM634D 12.V 159/159 37.8 208 4000x1250x2000 7600

C-CCF800J 800 880 KTA38-D(M)/880 LVM634F 12.V 159/159 37.8 208 4000x1250x2000 8000

NOTE: The above gensets are based on 50HZ, 1500RPM, rated voltage are 400/230V. Power factor is 0.8 and the connecƟng method is 3 phase and 4 wire. 60HZ gensets can be supplied according to the customers' requirements. The above technical data can be subject to change without noƟce due to conƟnuous improvements by manufacturers

Perkins Generator Perkins engine generators adopt the United Kingdom original Perkins engine with wide power ranges,

excellent reliability and service life, low operation cost and fast speed return cycle. Perkin series

generators are widely used in the communication, industrial sector, outdoor project and mining. The

Perkins diesel engines are manufactured by the UK Perkins company and its subordinate factories

according to their unified quality standards.

Model Power (KW) Engine Model Alternator Model No. of Bore X Stroke Displacement (L) 100% load fuel Overall Dimension Net Weight (kg)

Prime Standby PERKINS STAMFORD cyclinders &

(mm) consumpti on (L x W x H) (mm)

configuration (g/kw*h)

RP 7.2GF 7.2 8 403D-11G BC1164B 3L 77/81 1.13 248 1570X730X1200 360

RP-10GF 10 12 403D-15G BC1164C 3L 84/90 1.5 247 1570X730X1200 430

RP-12GF 12 13.2 404D-22G BC1164D 4L 84/100 2.2 245 1600X730X1250 500

RP-16GF 16 18 404D-22G BC1184E 4L 84/100 2.2 245 1600X730X1250 530

RP-20GF 20 22 404D-22TG BC1184F 4L 84/100 2.2 245 1600X730X1250 550

RP-24GF 24 26.4 1103A-33G BC1184G 3L 105/127 3.3 211 1750X730X1600 800

RP-30GF 30 33 1103A-33TG1 BC1184H 3L 105/127 3.3 215 2050X730X1600 920

RP-36GF 36 40 1103A-33TG1 UC1224D 3L 105/127 3.3 215 2050X730X1600 950

RP-40GF 40 44 1103A-33TG2 UC1224D 3L 105/127 3.3 215 2100X730X1600 950

RP-48GF 48 52 1103A-33TG2 UC1224E 3L 105/127 3.3 215 2100X730X1600 950

RP-52GF 52 58 1104A-44TG1 UC1224F 4L 105/127 4.4 208 2150X730X1600 1050

RP-64GF 64 70 1104A-44TG2 UC1224G 4L 105/127 4.4 215 2150X730X1600 1100

RP-80GF 80 90 1104C-44TAG2 UC1274C 4L 105/127 4.4 205 2250X730X1600 1250

RP-110GF 110 121 1006TAG UC1274E 6L 100/127 5.99 208 2600X730X1600 1400

RP-120GF 120 132 1006TAG2 UC1274F 6L 100/127 5.99 208 2600X730X1600 1450

RP-145GF 145 160 1106C-E66TAG4 UC1274G 6L 105/127 6.6 205 2650X730X1650 1700

RP-200GF 200 220 1306C-E87TAG6 UCD1274K 6L 116.6/135.9 8.7 201 3100X900X1600 2100

RP-250GF 250 280 2206C-E13TAG2 HC1444ES 6L 130/157 12.5 209 3500X1150X2000 3400

RP-280GF 280 300 2206C-E13TAG2 HC1444E 6L 130/157 12.5 209 3500X1150X2000 3450

RP-320GF 320 360 2206C-E13TAG3 HC1444F 6L 130/157 12.5 206 3500X1150X2000 3500

RP-360GF 360 400 2506CXE15TAG1 HC1544C 6L 137/171 15.2 216 4000X1200X2100 3600

RP-400GF 400 440 2506C-E15TAG2 HC1544C 6L 137/171 15.2 211 4000X1200X2100 3700

RP-480GF 480 528 2806A-E18TAG1A HC1544E 6L 145/183 18.1 203 4000X1600X2100 4500

RP-520GF 520 580 2806A-E18TAG2 HC1544F 6L 145/183 18.1 202 4000X1600X2100 4600

RP-580GF 580 640 4006-23TAG2A LV1634B 6L 160/190 22.9 209 4500X1750X2300 5500

RP-640GF 640 720 4006-23TAG3A LV1634C 6L 160/190 22.9 210 4500X1750X2300 5500

RP-720GF 720 800 4008TAG2A LV1634D 8L 160/190 30.5 206 4700X2050X2500 7700

RP-800GF 800 880 4008TAG2A LV1634E 8L 160/190 30.5 206 4700X2050X2500 7900

RP-1000GF 1000 1100 4012-46TWG2A LV1634G 12V 160/190 45.8 212 5300X2200X2600 10000

RP-1200GF 1200 1320 4012-46TAG2A P1734C 12V 160/190 45.8 207 5300X2200X2600 10200

RP-1320GF 1320 1500 4012-46TAG3A P1734D 12V 160/190 45.8 212 5300X2200X2600 10200

RP-1400GF 1400 1540 4016TAG P1734E 16V 160/190 61.1 205 5700X2800X3100 13200

RP-1600GF 1600 1800 4016TAG2A P1734F 16V 160/190 61.1 208 5800X2800X3500 13500

NOTE: The above gensets are based on 50HZ, 1500RPM, rated voltage are 400/230V. Power factor is 0.8 and the connecƟng method is 3 phase and 4 wire. 60HZ gensets can be supplied according to the customers' requirements. The above technical data can be subject to change without noƟce due to conƟnuous improvements by manufacturers

Imported Yanmar Engine Generator The original Yanmar engines are imported from Japan and are widely used in the

factories, railways and outdoor projects for small power generation because of their

compact configuration, ease of operation, environment friendly and low fuel consumption.

The Yanmar engines are in accordance with the EU and EPA Emissions standard. Power (KW) Engine Model Alternator Model No. of

Bore X Stroke 100% load fuel Overall Dimension

Model

cyclinders & Displacement (L) consumption Net Weight (kg)

Prime Standby YANMAR STAMFORD (mm) (L x W x H) (mm)

configuration

(g/kw*h)

RYM-6.4GF 6.4 7.0 3TNV76-GGE(T4) BCI164A 3.L 76/82 1.116 258 1100x530x1020 350

RYM-7.5GF 7.5 8.2 3TNV82A-GGE(T2) BCI164B 3.L 82/84 1.331 245 1150x530x1020 360

RYM-10GF1 10 11 3TNV88-GGE(T2) BCI164C 3.L 88/90 1.642 245 1200x530x1020 430

RYM-10GF2 10 11 3TNV88-BGGE(T3) BCI164C 3.L 88/90 1.642 245 1200x530x1020 430

RYM-12.8GF1 12.8 14 4TNV88-GGE(T2) BCI164D 4.L 88/90 2.19 245 1350x560x1060 480

RYM-12.8GF2 12.8 14 4TNV88-BGGE(T3) BCI164D 4.L 88/90 2.19 251 1350x560x1060 480

RYM-15GF1 15 16.5 4TNV84T-GGE(T2) BCI184E 4.L 84/90 1.995 245 1350x560x1060 490

RYM-15GF2 15 16.5 4TNV84T-GGE(T3) BCI184E 4.L 84/90 1.995 245 1350x560x1060 490

RYM-20GF1 20 22 4TNV98-GGE(T2) BCI184F 4.L 98/110 3.319 231 1650x600x1150 640

RYM-20GF2 20 22 4TNV98-ZGGE(T3) BCI184F 4.L 98/110 3.319 234 1650x600x1150 640

RYM-25GF1 25 28 4TNV98-GGE(T2) BCI184G 4.L 98/110 3.319 231 1650x600x1150 640

RYM-25GF2 25 28 4TNV98-ZGGE(T3) BCI184G 4.L 98/110 3.319 234 1650x600x1150 640

RYM-30GF1 30 33 4TNV98T-GGE(T2) BCI184H 4.L 98/110 3.319 222 1680x600x1150 680

RYM-30GF2 30 33 4TNV98T-GGE(T3) BCI184H 4.L 98/110 3.319 231 1680x600x1150 680

RYM-36GF 36 40 4TNV106-GGE(T2) UCI224D 4.L 106/125 4.412 238 1860x650x1250 800

RYM-40GF 40 44 4TNV106T-GGE(T2) UCI224D 4.L 106/125 4.412 221 1860x650x1250 870

NOTE: The above gensets are based on 50HZ, 1500RPM, rated voltage are 400/230V. Power factor is 0.8 and the connecƟng method is 3 phase and 4 wire. 60HZ gensets can be supplied according to the customers' requirements. The above technical data can be subject to change without noƟce due to conƟnuous improvements by manufacturers

Sound Proof Gensets Silent gensets are manufactured in accordance with GB/T2820-97

standard. The gensets operate well with good ventilation system and

heat protection and noise reduction measures.

Trailer Gensets The trailer gensets are can be mounted on trailers that are single

bearing or double bearing, and dual wheels or four wheels. The trailer

units are in compliance with vehicle running safety requirements and

standards.

Special Type Gensets The gensets can be containerised or installed on vehicles. The safety and electrical features can be made in accordance with

customers' requirements and are in compliance with the relevant

standards.

Kejuruteraan Mega ACP Sdn Bhd (www.megaacp.com.my)

Johor : Tel: 607 3867168, Fax: 607 3861729, Email: [email protected]

Selangor : Tel: 603 80239248, Fax: 603 80239249, Email: [email protected]

Penang : Tel: 604 5072727, Fax: 604 5072728, Email: [email protected]