yoga extraction arms - formula-air.com · the yoga extraction arms are designed for dust and...

18
YOGA extraction arm hanging version Application The YOGA extraction arms are designed for dust and welding fume extraction as well as capturing fine dust particles. The pollutants are captured directly at the emission source, avoiding their expansion within the room and inhaling by people. The arms are manufactured in a hanging or standing version. The extraction arm can work independently, with a single extraction fan or connected to the main collecting ductwork with a central fan. Structure The YOGA extraction arm consists of following elements: • swivel with integrated shut-off damper, • hood made of plastic with integrated handle, two pipe segments integrated by frictional joints, gas springs to balance the weight of the pipe segments, Operational use Use a wall bracket to mount the arm on a wall or column. Additionally, the wall bracket can be connected to a extraction fan or connection ferrule. Adequately adjusted frictional joints, along with the springs, provide convenient arm manoeuvring and position adjustment. The suction hood can be equipped with a halogen spotlight to light up the workspace. Recommended volume flows for following arm sizes are: Ø 100 = 350 m³/h Ø 125 = 700 m³/h Ø 160 = 1000 m³/h Ø 200 = 2000 m³/h YOGA - Extraction arms TAB5 | Fume extraction FA.T05.FE.2017.V2.1.UK workranges of the YOGA extraction arms Type YOGA L & D-2 1400 2300 2400 600 YOGA L & D-3 2200 3200 3200 750 YOGA L & D-4 2700 3800 3700 1200 Type 2200 1700 0 3000 2500 150 YOGA L & D-2-R 2000 YOGA L & D-3-R 2850 YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N WORK RANGE K [mm] L [mm] M [mm] N [mm] K [mm] L [mm] M [mm] N [mm]

Upload: lamphuc

Post on 28-Feb-2019

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

YOGA extraction arm – hanging version

ApplicationThe YOGA extraction arms are designed for dust and welding fume extraction as well as capturing fine dust particles. The pollutants are captured directly at the emission source, avoiding their expansion within the room and inhaling by people. The arms are manufactured in a hanging or standing version. The extraction arm can work independently, with a single extraction fan or connected to the main collecting ductwork with a central fan.

Structure

The YOGA extraction arm consists of following elements:• swivel with integrated shut-off damper,• hood made of plastic with integrated handle,• two pipe segments integrated by frictional joints,• gas springs to balance the weight of the pipe segments,

Operational useUse a wall bracket to mount the arm on a wall or column. Additionally, the wall bracket can be connected to a extraction fan or connection ferrule. Adequately adjusted frictional joints, along with the springs, provide convenient arm manoeuvring and position adjustment. The suction hood can be equipped with a halogen spotlight to light up the workspace.

Recommended volume flows for following arm sizes are: Ø 100 = 350 m³/hØ 125 = 700 m³/hØ 160 = 1000 m³/hØ 200 = 2000 m³/h

YOGA - Extraction arms

TAB5 | Fume extraction

FA.T05.FE.2017.V2.1.UK

workranges of the YOGA extraction arms

Type

YOGA L & D-2 1400 2300 2400 600YOGA L & D-3 2200 3200 3200 750

YOGA L & D-4 2700 3800 3700 1200

Type

2200 1700 03000 2500 150

YOGA L & D-2-R 2000

YOGA L & D-3-R 2850

YOGA L & D-4-R 3400 3650 3000 500

Volumes

L

KM

N

WORK RANGE

L

KM

N

WORK RANGE

K [mm] L [mm] M [mm] N [mm] K [mm] L [mm] M [mm] N [mm]

Page 2: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Hanging version Standing version

eRGO extractio arms local exhausts

TypeDimensions Weight

[kg]Dn [mm] L [m] A [mm] B [mm] C [mm]

Hang

ingversion St

anda

rdhoo

d

100 1,8 630 555 335 10,0100 2,2 960 675 335 11,0125 2,3 1055 650 335 12,5125 3,0 1540 915 335 14,0160 2,3 905 790 335 17,5160 3,15 1530 1030 335 19,5160 3,8 1910 1260 335 22,0200 2,3 645 790 335 19,0200 3,15 1530 1030 335 22,5200 3,8 1910 1260 335 25,0

Hood

with

ha

logenlight

160 2,3 905 790 335 17,5160 3,15 1530 1030 335 19,5160 3,8 1910 1260 335 22,0200 2,3 905 790 335 19,0200 3,15 1530 1030 335 22,0200 3,8 1910 1260 335 25,0

Stan

ding

versio

n

Stan

dardhoo

d

100 1,6 9,5100 2,1 10,5125 2,2 12,5125 2,9 14,0160 2,2 17,0160 3,0 19,0160 3,65 21,0200 2,2 17,5200 3,0 21,0200 3,65 23,5

Hood

with

ha

logenlight

160 2,2 17,0160 3,0 19,0160 3,65 21,0200 2,2 17,5200 3,0 21,0200 3,65 23,5

YOGA - Extraction arms

TAB5 | Fume extraction

FA.T

05.F

E.20

17.V

2.1.

UK

Wall bracket Material S [mm] Weight [kg]

steelsheet 250 3

320 4,6

Suitable extraction arms

YOGA M & K

340 6,1 YOGA D

steelsheet

steelsheet

steelsheet

630 555 335960 675 335

1055 650 3351540 915 335905 790 335

1530 1030 3351910 1260 335645 790 335

1530 1030 3351910 1260 335

905 790 3351530 1030 3351910 1260 335905 790 335

1530 1030 3351910 1260 335

YOGA L

YOGA-M/1,5YOGA-M/2YOGA-K/2YOGA-K/3YOGA-L/2YOGA-L/3YOGA-L/4YOGA-D/2YOGA-D/3YOGA-D/4

YOGA-LL/2YOGA-LL/3YOGA-LL/4YOGA-DL/2YOGA-DL/3YOGA-DL/4

YOGA-M/1,5-R YOGA-M/2-R YOGA-K/2-R YOGA-K/3-R YOGA-L/2-R YOGA-L/3-R YOGA-L/4-R YOGA-D/2-R YOGA-D/3-R YOGA-D/4-R

YOGA-LL/2-RYOGA-LL/3-RYOGA-LL/4-RYOGA-DL/2-RYOGA-DL/3-RYOGA-DL/4-R

Type

YOGA-K-WALLSUPP

YOGA-L-WALLSUPP

YOGA-D-WALLSUPP

Page 3: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Suction hood Material Type Z [mm] T [mm] H [mm] Weight [kg] Equipment

ABS plastic MST 330 100 190 0,350 replaceableinlet wire-mesh

KST 330 125 190 0,436

ABS plastic LST 365 170 190 0,420

DST 415 210 190 0,530

ABS plastic LLT 365 170 190 0,450 halogenlight12Vswitch

DLT 415 210 190 0,550

YOGA - Extraction arms

TAB5 | Fume extraction

FA.T05.FE.2017.V2.1.UK

ABS plastic

ABS plastic

replaceableinlet wire-mesh

replaceableinlet wire-mesh

replaceableinlet wire-mesh

replaceableinlet wire-mesh

ABS plastic halogenlight12Vswitch

replaceableinlet wire-mesh

flow charts of YOGA extraction arms

Wire mesh Type Weight [kg] Hood type

D ST 0,15 DST

L ST 0,10

MKST

DLT

0,08

LL T 0,09

LST

SMT, KST

LLT

LLT0,14

YOGA - M YOGA - K

YOGA - L YOGA - D

Page 4: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

YOGEX-L/Z extraction arms are manufactured according to the ATEX 95 (94/9/EC) directive and carry the Research Certificate No 737/Cw/001 issued by the Technical Supervision Office.

YOGEX extraction arm - hanging version

ApplicationTheYOGEX-L/Zextraction armsaredesigned for capturing thedustandgasesarisingduringtechnologicalprocesses,inareasofexplosion risk, where explosive atmosphere can occur, as amixtureofflammablesubstancesinformofdustorgasesintheair.YOGEX-L/ZextractionarmshavebeenclassifiedasdevicesofgroupII,category2,forgaseousriskGanddustriskD.

The devices guarantee high level of protection therefore theycanbeappliedinareas1(G)or21(D).Admissibletemperatureofthetransportedairis+70°C.

StructureYOGEX-L/Zextraction armsconsistoffollowingelements:

• full-rotation stainless steel swivel,• stainless steel circularhood,• twostainless steel pipesegmentswithjoints,• textolite frictional spacers,• stainless steel gassprings,• stainless steel shut-offdamperlocatedinthepipesegment

nearabovethe hood• Conductive polyurethane hosesections with steel wire spiral

(joiningthepipesegments)

Superficial resistance <106 Ω. All steel elements ; pipes and stainless profile are made of 1.4301 materialaccordingtoPN-EN 10088, whereas screw materials, washers and rivets are of A2 material according to PN-EN ISO 7089. All the steel elements are joined together by copper wires that ensure the conductivity of the whole and conduct the electrostatic discharges to the grounding of the installation.

YOGEX - Extraction arms ATEX II 2G/D

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGEX extraction arm -standing version

0

200

400

600

800

1000

1200

1400

1600

1800

2000

2200

2400

2600

2800

200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600

2

1

Flow

resis

tanc

es[P

a]

1.Stretchedarm2.Bentarm

airflow [m³/h]

flow charts of the YOGEX extraction arms

Page 5: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Hanging version Standing version

Suction hood Material Type d [mm] D [mm] Weight [kg]

stainlesssteel LS 160 336 1,3

YOGEX-L-WALLSUPP 160 320 445 3,9

S

L

D

YOGEX - Extraction arms ATEX II 2G/D

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

Type Dimensions Weight

[kg]Dn [mm]

L [mm] A [mm] B [mm] C [mm]YOGEX-L/Z-2 160 2280 947 580 534 22,5YOGEX-L/Z-3 160 3100 1527 820 534 25,5YOGEX-L/Z-4 160 3710 1907 1050 534 28,0

YOGEX-L/Z-2-R 160 3710 947 580 534 19,5YOGEX-L/Z-3-R 160 3033 1527 820 534 22,5YOGEX-L/Z-4-R 160 3643 1907 1050 534 25,0

Type Dn [mm] S [mm] L [mm] Weight [kg]Wall bracket

wallbracket

Page 6: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Hanging version Standing version

YOGF extraction arm- hanging version

ApplicationYOGF extraction arms are designed for dust and welding fumeextraction, as well as the capturing of fine dust particles. Thepollutantsarecaptureddirectlyattheemissionsource,avoidingtheirexpansion within the room and inhaling by people. The arms aremanufactured in a hanging or standing version.The extraction arm can work independently, with a single extraction fan or connected to the main collecting ductwork with a central fan. Structure

TheYOGFextractionarmconsistsoffollowingelements:

• swivel,• hood,• flexible hose sleeved onto the supporting structure in

aluminumprofiles,• tensionspringtoprovidethebalanceofthearm.

Use a wall bracket to mount the arm on a wall or column. Additionally, the wall bracket can be connected to a extraction fan or connection ferrule. Adequately adjusted frictional joints, along with the springs, provide convenient arm manoeuvring and position adjustment. The suction hood can be equipped with a halogen spotlight to light up the workspace.

The YOGF isonly manufactured indiameter160mm,with a recommendedair volumeof1000m³/h.

TypeDimensions Weight

[kg]A [mm] B [mm] C [mm] L [m]Dn [mm]

YOGF-2 396 553 976 2160 6YOGF-3 396 953 1531 3160 8YOGF-4 396 1253 2031 4160 9

YOGF-2-R 396 553 976 2160 6YOGF-3-R 396 953 1531 3160 8YOGF-4-R 396 1253 2031 4160 9

YOGF - Extraction arms

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

Page 7: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

FlowchartoftheYOGF–length2m FlowchartoftheYOGF–length3m

FlowchartoftheYOGF–length4m

Flow

resis

tanc

es[P

a]

Flow

resis

tanc

es[P

a]

Flow

resis

tanc

es[P

a]

aluminum LSO/YOGF 173 336 226,5 1 replaceableinletwire-mesh

aluminum LLO/YOGF 173 336 226,5 1,4replaceableinletwire-meshhalogenlight12Vswitch

1.Stretchedarm2.Bentarm

airflow [m³/h]

steel YOGA-L-WALLSUPP 277 7 YOGF-L/Z

S

airflow [m³/h]airflow [m³/h]

YOGF - Extraction arms

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

flow charts of the YOGF extraction arms

Suction hood Material Type d [mm] D [mm] L [mm] Weight [kg] Equipment

Wall bracket Material Type S [mm] Weight [kg] Suitable extraction arms

Page 8: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

YOGB-l-2-2400

YOGB-l-3-2000YOGB-l-1600

Application

YOGBextractionarmsare designed foreffectiveextractionofwelding dust and gas contamination, as well as other smalldustparticles, directly at the emission source. It is importantnottoallowthecontaminationtoexpandintheprocessroom,preventing it from being inhaled by people. The extractionarms can be applied in any areas where the workspace islimited.Commonly, this is thecase inweldingschools,wheretheweldingbootsareverysmall.The extraction arm can work independently, with a single extraction fan or connected to the main collecting ductwork with a central fan.

StructureTheextractionarmconsistsoffollowingelements:

• swivel,• suctionhoodwithashut-offdamper,• pipe segments of telescopic construction – the segments

slide in one another (in case of YOGB the supporting structureismadeoftheslidersinsidetheflexible hose).

Pipesegmentsaremadeofstainlesssteel,whereastheswivelelements are aluminum cast. The nominal diameter of thearms is 160 mm. The extraction arm is equipped with africtionaljointlocatedneartheswivel.

Operational useUse a Wall bracket to install the extraction arm on a wall orsupportingcolumn.Additionally,theextraction fan or ducting can be directly connected to the wall bracket. Thepipe segmentscanslidetelescopically, one segment can turn within the other segment,providing themost useful position of the suction hood. Adequatelyadjustedfrictionaljointgiveseasymanoeuvrabilitywiththearm.Thesuction hood is equipped with a shut-off damper to adjust theairflow.TheYOGB-L-3-3000 isadditionallyequippedwitha supportofthegasspring,improvingthemanoeuvrabilityperformance.

YOGB - Extraction arms

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

0

200

400

600

800

1000

1200

1400

1600

1800

2000

200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400airflow[m³/h]

Flow

resis

tanc

es[P

a]

flow chart

Page 9: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Type Nominal diameter Dn [mm]

Ds [mm]

Recommended airflow

[m³/h]

Quantity ofsegments

Workrange [mm] Weight[kg]Rmin Rmax

160 315 1000 2 1600 2000 11,5160 315 1000 2 1800 2400 13

YOGB-L-2-2000 YOGB-L-2-2400 YOGB-L-3-3000 160 315 1000 3 1850 3000 15

Nominal diameter Dn [mm]

Ds [mm]

Recommended airflow[m³/h]

Quantity ofsegments

Workrange [mm] Weight [kg]Rmin Rmax

Type

YOGB-L-3-2000 160 235 1000 3 1000 2000 13

YOGB-l-3-2000

YOGB-l-2-2400

teleRGO extractio arms local exhausts

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGB - Extraction

arms Dimensions

Rmax

Ds

Rmin

YOGT-l-1600

Nominal diameter Dn [mm]

Ds [mm]

Recommended airfloww [m³/h]

Workrange [mm] Weight [kg]Rmin Rmax

Type

YOGB-L-1600 160 235 1000 1000 1600 10

Page 10: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGB - Extraction

arms Accessories

Suction hood Material Type d [mm] D [mm] L [mm] Weight [kg] Remarks

aluminum LSO-S 170 275 125 0,65

replaceableinlet wire-mesh

shut-offdamper for arms :

YOGB-L-1600, YOGB-L-3-2000

aluminum LSO/YOGB 173 340 227 0,72

replaceableinlet wire-mesh

shut-off damper for arms :

YOGB-L-2-2000, YOGB-L-2-2400, YOGB-L-3-3000

Type D [mm] Weight [kg] Remarks

WOLS 226 0,06 forthehoodLSO-S

Replaceable inlet wire-mesh

steelsheet YOGA-L-WALLSUPP 277 7

S

Dd

L

d

L

D

D

Wall bracket Material Type S [mm] Weight [kg]

WOL 287 0,09 forthehoodLSO/YOGB

Page 11: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

A set of arms in basic version – rotational extension YOGA-RO-2,5-E-L/x and an extraction arm :

A set of arms in a “broken” version – rotational extension YOGA-RO-4-E-L/y, with rotational extension YOGA-RO-2,5-E-L/x and extraction arm :

extraction arm

rotational extensionYOGA-RO-4-E-L/Y

rotational extensionYOGA-RO-2,5-E-L/X

extraction armrotational extensionYOGA-RO-2,5-E-L/X

Application Structure

Therotationalextensionconsistsofabearingswivelandthesteelductof rectangular section. the YOGA-RO-L/Xextensions of range1,5and2,5mareequippedwith swivelsmadeofaluminiumcastringswitharollerbearing,whereastheotherrotational extensionshavesteelswivelswithslidebearings.Theirtorsionresistancesareminimal,providingeasymanoeuvringof thearmwithin theworkarea.

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-RO-L/X extension - Extraction arms

The YOGA-RO rotationalextensions increase the rangeof thehangingYOGAextractionarms.Inthebasicversion,attheendoftherotationalextensionisfastenedanYOGAextractionarm.Whereas, in the “broken” version – YOGA arm has to befastened at the end of the set consisting of two rotationalextensions.

Page 12: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Rotational extensionstypeYOGA-RO-E-L/XareadaptedtoconnecttheYOGA-Lextractionarmat its freeend.Therotational extensions YOGA-RO-1,5 and YOGA-RO-2,5havetobemountedtothewalloftheroombymeansofaYOGA-RO/Lwallbracket,whereas the YOGA-RO-4-E-L/X can bedirectlymounted on tothewall.

Rotational extension YOGA-RO-E-L/x

Rotational extension YOGA-RO-1,5-E-L/x :

Rotational extension YOGA-RO-2,5-E-L/x :

Rotational extension YOGA-RO-4-E-L/x :

M–maximumtorqueapplyingloadonthearm–seeTableTECHNICALDATA.

RO rotationa arms local exhausts

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-RO-L/X extension - Extraction arms

Page 13: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Rotational extension YOGA-RO-E-L/y The rota�tionalextensionYOGA-RO-E-L/Yhasbeendesignedto connecttheYOGA-RO-1,5-E-L/X or YOGA-RO-2,5-E-L/Xrota�tionalextensiontogether withtheYOGA-Lextrac�tionarm.Therota�tionalextensionismounteddirectlytothewall.

Rotational arm YOGA-RO-4-E-L/y

Rotational arm YOGA-RO-2,5-E-L/y

TheYOGA-RO/Lbracketservestoinstalltherotati�onalextensions YOGA-RO-1,5-E-L/X or YOGA-RO-2,5-E-L/X.The wallbracketis optional equipmentoftherota�tionalextensions–ithastobeorderedseparately.ExtensionsYOGA-RO-4-E-L/X,YOGA-RO-2,5-E-L/Y and YOGA-RO-4-E-L/Yarenotequippedwitha �flangetomountan extractionfan.M–maximumtorqueapplyingloadonthearm–seeTableTECHNICALDATA.

RO rota�onal arms local exhausts

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-RO-E-L/Y extension - Extraction arms

Page 14: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

TypeConnecti�on

diameter [mm]

Weight[kg]

Maximum torque M [Nm]

YOGA-RO-1,5-E-L/X 160 46 1400YOGA-RO-2,5-E-L/X 160 51 1700YOGA-RO-4-E-L/X 160 84 3100

YOGA-RO-2,5-E-L/Y 160 68 4400YOGA-RO-4-E-L/Y 160 98 6400

NOTE: Beforeinstallingtherota�tionalextensions,checkiftheloadcapacityofthewall(orotherconstructi�onalelementofthebuilding)isdufficient to bear the load M, and it is also important to select the appropriate bolts.

Flow

resis

tanc

es[P

a]

1.Armstretched2.Armbent

airflow [m³/h]

flow charts of the YOGA-RO rotational extensions

RO-4-E-L

RO-2,5-E-L

RO-1,5-E-L

RO rota�onal arms local exhausts

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-RO-E-L/X extension - Extraction arms

Page 15: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

TypeNominal diameter Dn [mm]

Recommended air volume

[m³/h]

WorkrangeWeight

[kg]

Maximum torque M

[Nm]

Sort of the applied rota�tional

armsL₁ [mm] L₂ [mm] Lmax [mm] Hmax [mm] Hmin [mm]

YOGA-ROL-TP-2,5-1,5 160 1000 2460 1700 4160 3200 1800 127 3500 YOGA-RO-2,5-E-L/Y+YOGA-RO-1,5-E-L/X

YOGA-ROL-TP-2,5-2,5 160 1000 2460 2230 4690 3200 1800 132 3800 YOGA-RO-2,5-E-L/Y+YOGA-RO-2,5-E-L/X

YOGA-ROL-TP-4-1,5 160 1000 3710 1700 5410 3200 1800 158 5000 YOGA-RO-4-E-L/Y+YOGA-RO-1,5-E-L/X

YOGA-ROL-TP-4-2,5 160 1000 3710 2230 5940 3200 1800 163 5710 YOGA--4-E-L/Y+YOGA-RO-2,5-E-L/X

NOTE: Priortoinstallingtheextrac�tionassembly,checkiftheloadcarryingcapacityofthewall(orotherconstruc�onalelement)issu�fficienttoresistthetorqueM and select the appropriate mounting bolts.

technical data

Application

The YOGA-ROL-TP extraction systems is meant for dust-gas contamination extraction at mobile workplaces. Additionally, it can be used for effective removal of exhaust gas emitted through exhaust pipe of vehicles not being in movement. Generally, the appliance can serve vehicles with a vertical exhaust pipe (directed upwards) as well as traditional vehicles with horizontal exhaust pipe. The extraction set can work with a fan mounted on a wall bracket or located on a roof. Additionally, the assembly can be connected to a collecting extraction ductwork.

StructureYOGA-ROL-TPsetconsistsoffollowingelements:

• setoftworota�tionalarms,• ver�ticaltelescopicduct,• sucti�onhood.

Therotati�onalarmconsistsofaswivelwithbearing,andahorizontalmetalductofsquaresec�tion.

Fric�tionmovementresistanceisminimal,allowingforeasymovementofthearminthehorizontalplane.

Two rota�tional arms are connected together in a “broken”version (i.e. one arm is suspended at the end of the otherarm),whereas the vertical telescopicduct is fastenedat theend of the terminal rotati�onal arm. The segmented ver�ticaltelescopic duct provides posi�tioning of the hood in therequestedheightand it ispossibletoblock itbymeansofanadjus�tingcable.A hood is fastened at the telescopic duct through a quick-connector.Wehavea choiceof three sortsofhoods:YOGAhood to extract welding fumes, large extracti�on hood toremovewelding fumes or exhaust gas from ver�tical exhaustsystems and extrac�tion nozzle for gas removal from ver�ticalexhaustpipe.

Operational useBefore the start of the process, it is important to fastenthrough a quick-connector a suitable hood, adjustadequately the set of rota�tional arms, and then with anadjustmentcablesetthehoodinadequateheight.

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-ROL-TP extension - Extraction arms

Page 16: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

0

500

1000

1500

2000

2500

500 1000 1500

Opo

rypr

zepł

ywy

[Pa]

Wydatek [m3/h]

Charakterystyka przepływowa ramion

TypeDimensions Weight

[kg] Remarks D [mm] H [mm]

Sort of the hood

YOGAsucti�onhood

SE-L-160 160 635 2,6 aluminum,hoseisfastenedbyaquick-connector

Bellsuc�tionhood

SO-L-500 500 540 2,0 aluminum,hoseisfastenedbyaquick-connector

nozzleforexhaustpipes

SW-L-200 200 190 3,0 metallic,hoseisfastenedbyaquick-connector

quick-connectorofthehood

adjusti�ngcable

ver�ticaltelescopicpipe

rota�tionalarmYOGA-RO-E-L/X

rotati�onalarmYOGA-RO-E-L/Y

2000

1500

1000

500

0

YOGA-ROL-TP-4-2,5YOGA-ROL-TP-4-1,5

YOGA-ROL-TP-2,5-2,5,YOGA-ROL-TP-2,5-1,5

Flow

resis

tanc

es[P

a]

2000

airflow [m³/h]

flow charts

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-ROL-TP extension - Extraction arms

Page 17: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Type Segment length [m]

Secti�on[cm²]

Unit weight [kg/m]

YOGA-KOS-AL 2or4 290 9,7

extraction arm YOGA extraction arm YOGB

suction duct YOGA-KOS-al

technical data

YOGA-OP-L 9Trolley

ApplicationYOGA-KOS-AL extraction system has been developed for capturing the welding fumes at the mobile workplaces, for welding straight-shaped elements – of length from several metres up to several -tens of meters.The system can be operated by one or two extraction fans, depending on the quantity of applied YOGA extraction arms (one YOGA arm is cooperating with one fan).

StructureTheYOGA-KOS-ALextrac�tionsystemconsistsofsubsequentassemblies:

• self-�thightening suc�tion duct – type YOGA-KOS-AL (ofaluminium segments of length 2 m or 4 m – joinedtogetherintoa requestedductlength),

• trolley–displacingalongtheduct,• extrac�tionarmYOGA-ERGOorERGOFLEX–suspended

underneath the trolley (maximum 3 m),• ��fittingpiecesandsuppor�tingelements–accordingtothe

arrangement below.

Operational useDuring the welding the operator moves the YOGA extraction arm with the trolley along the suction duct. The hood of the arm ought to be adjusted in a distance ca. 30 cm from the welding point. Low movement resistances of the trolley and easy adjustment of the hood provides perfect manoeuvring of the whole system. After the completed work at one welding post, close the shut-off damper (placed at the hood) to improve the suction volume in the second extraction arm. Two extraction arms can be installed at one suction duct simultaneously.

Self-tightening suction duct

Element

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-KOS-AL extension - Extraction arms

Page 18: YOGA Extraction arms - formula-air.com · The YOGA extraction arms are designed for dust and welding fume ... YOGA L & D-4-R 3400 3650 3000 500 Volumes L K M N WORK RANGE L K M N

Type Weight[kg] Remarks

YOGA-L/Z-2 16,2

Detaileddimensionsoftheextrac�tionarmsERGOandERGO-FLEXarelistedonseparatecataloguecards.

YOGA-L/Z-3 18,3YOGA-FLEX-2 6YOGA-FLEX-3 8

Extraction arms

/ƻƴƴŜŎǘƛƻƴ ŦŜNJNJdzƭŜ ¢ȅLJŜ 5ƛŀƳŜǘŜNJώƳƳϐ

wŜƳŀNJƪǎ

foraxial connection KPC 160 Toconnecttheducttothedischargeinstallati �on.

5dzŎǘ ƘŀƴƎŜNJ ¢ȅLJŜ wŜƳŀNJƪǎ

forceilingmounti�ng ZHangersarefastenedattheductbybol�ting.Thespacingbetweenthehangersshouldnotbelargerthan3m.

forwallmoun�ting Z

Type Remarks

STKTostopthemovementofthetrolleyattheductend.

Terminal stopper

Duct segment connector

KSG

Type Remarks

PZCAreinstalledatthefrontendofthe�firstsegmentorattheterminalendofthelastsegmentoftheduct.

Duct closing

TAB5 | Fume extraction

FA.T

05.F

E.20

14.V

2.0.

UK

YOGA-KOS-AL extension - Extraction arms

Hangersarefastenedattheductbybol�ting.Thespacingbetweenthehangersshouldnotbelargerthan3m.

Type