yaskawa vs-606 v7 compact vector - controlled inverter for general use 230v (single-phase).1kw ~...

27
YASKAWA VS-606 V7 VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase) .1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase) .1Kw ~ 7.5Kw (.13HP ~ 10HP) 460V (Three-Phase) .2Kw ~ 7.5Kw (.25HP ~ 10HP)

Upload: tracey-doyle

Post on 13-Dec-2015

227 views

Category:

Documents


2 download

TRANSCRIPT

YASKAWA

VS-606 V7VS-606 V7

COMPACT VECTOR - CONTROLLEDINVERTER FOR GENERAL USE

230V (Single-Phase) .1Kw ~ 3.7Kw (.13HP ~ 5HP)230V (Three-Phase) .1Kw ~ 7.5Kw (.13HP ~ 10HP)460V (Three-Phase) .2Kw ~ 7.5Kw (.25HP ~ 10HP)

YASKAWA

VS-606 V7 ObjectiveVS-606 V7 Objective

Define the IDEAL Characteristics of a Drive

Define Features and Functions Cost Comparison Benefits and Advantages Target Application

YASKAWA

VS-606 V7 Customer VS-606 V7 Customer RequirementsRequirements

Full Feature Cost Reduction

Price Space Savings Optimum Motor/Drive Operation Optimum Global Enclosure Design

“World Class” Quality

YASKAWA

VS-606 V7 Customer VS-606 V7 Customer RequirementsRequirements

Global Construction Customization Wide HP Range Full Line of Network Options

YASKAWA

VS-606 V7VS-606 V7 Design Features Design Features

HP Range 230V, 1 Ph, 1/8 to 5HP 230V, 3 Ph, 1/8 to 20 HP 460V, 3 Ph, 1/4 to 20HP

Output Frequency - 400Hz Speed Regulation:

V/Hz w/Slip Compensation - +/- 0.5% to 1%

Open Loop Vector Control - +/-0.2%

YASKAWA

VS-606 V7VS-606 V7 Design Features Design Features

Digital Operator with analog speed pot 4 Character 7 Segment LED Display Copy Keypad Function RJ-11 Style Connector for Remote Mounting

Digital Inputs - Qty. 7 7 multi-function logic inputs 24 Vdc Control Logic compatible with sourcing

or sinking outputs (PNP or NPN)

YASKAWA

VS-606 V7VS-606 V7 Design Features Design Features

Digital Pulse Train Input Analog Inputs - Qty. 2

Digital Operator Speed Pot 0-10v, 4-20mA, or 0-20mA input terminal

Digital Outputs - Qty. 2 1 multi-function relay - Form C 2 programmable open collector outputs

YASKAWA

VS-606 V7VS-606 V7 Design Features Design Features

Analog/Pulse Output Monitor Analog Output: 0-10vdc Frequency Output: 1f, 6f, 12f, 24f, 36f

selectable Monitor Functions:

Output Frequency Output Current Torque

Built-in Braking Transistor

YASKAWA

VS-606 V7VS-606 V7 Design Features Design Features

RS-485/422 Serial Communication Port Standard - Control up to 32 Drives

Future Available Networks: DeviceNet Profibus-DP Interbus-S Modbus Plus SDS Others

YASKAWAV7 Connection DiagramV7 Connection Diagram

YASKAWA

VS-606 V7 Program FeaturesVS-606 V7 Program Features

Approx. 200 Programming Parameters V/Hz or Open Loop Vector Control 16 Preset Speeds plus Jog Energy Savings PID Control with Loss of Feedback

YASKAWA

VS-606 V7 Program FeaturesVS-606 V7 Program Features

Cooling fan controlled by Power ON Run/Stop Command

Momentary Power Loss Ride-Thru 3 Skip Frequencies Elapse Timer Function Auto Tuning of Primary Resistance

YASKAWA

VS-606 V7 Protective FeaturesVS-606 V7 Protective Features

UL Recognized Electronic Motor Overload

Current limit Stall prevention during;

accel, decel, and run

DC Bus Charge Indicator

YASKAWA

VS-606 V7 Protective FeaturesVS-606 V7 Protective Features

Motor and Drive overload Instantaneous Overcurrent Short Circuit Undervoltage and Overvoltage Heatsink Overtemperature Ground Fault Protection Over/Under torque

YASKAWA

VS-606 V7 OptionsVS-606 V7 Options

Enclosures NEMA 1 NEMA 12 & NEMA 4 (Planned)

Dynamic Braking Resistor External DC Link Reactor Future Serial Communications

YASKAWA

VS-606 V7 Cost ComparisonVS-606 V7 Cost Comparison

VS-606 V7 comparison versus; VS mini VS-606 PC3

YASKAWA

VS-606 V7 Cost ComparisonVS-606 V7 Cost Comparison

020406080

100120140160

Percent Variation( Per HP Rating )

.75HP 1HP 2HP 3HP

HP Rating

230V VS-606V7 Comparison

V7VS miniPC3

YASKAWA

VS-606 V7 Cost ComparisonVS-606 V7 Cost Comparison

020406080

100120140160

Percent Variation( Per HP Rating )

0.75HP 1HP 2HP 3HP

HP Rating

460v VS-606 V7 Comparison

V7VS miniPC3

YASKAWA

VS-606 V7 Our StrengthsVS-606 V7 Our Strengths

Features/Functions Yaskawa AB Toshiba Master VectorVS-606 V7 Bulletin 160 VF-S7 6SE92

Control Methods V/Hz or V/Hz V/Hz or Sensorlessopen loop vector sensorless vector vector

PID PID PI PID w/dig. setptEnergy Saver Standard StandardPreset Speeds 17 8 15 3Low Noise Operation up to 10 kHz up to 8 kHz 2.2 - 12 kHz 2.44,4,8,&16 kHzAnalog Inputs 2 2 2 2Analog Outputs 1 none 1 1Digital Inputs 7 + Pulse Train 7 5 6Digital Outputs 3 1 2 2RS-422/485 port Standard Standard StandardKeypad / Operator 4 digit, 7 segment LED Optional- 7 segment 4 digit, 7 segment LED 4 digit, 7 button

display w /speed pot LED display display w /speed pot LED's

YASKAWA

VS-606 V7 Our StrengthsVS-606 V7 Our Strengths

Features/functions Yaskawa Mitsubishi Baldor FujiVS-606 V7 A024 Series 10 FVR-E7S

Control Methods V/Hz or V/Hz or V/Hz V/Hzopen loop vector flux vector

PID PID N/AEnergy Saver Standard N/APreset Speeds 17 7 8 7 (opt. for 15)Low Noise Operation up to 10 kHz up to 14.5 kHz 9.2 kHzAnalog Inputs 2 3 3 1Analog Outputs 1 1 1 1Digital Inputs 7 + Pulse Train 2 7Digital Outputs 3 2 2 2RS-422/485 port Standard Option N/AKeypad / Operator 4 digit, 7 Segment LED simple 4 x 7 7 segment 4 digit

display w /speed pot segment backlit LCD LED keypad

YASKAWA

VS-606 V7 Our StrengthsVS-606 V7 Our Strengths

Features/functions Yaskawa ABB Square D AC TechVS-606 V7 ACS 140 Altivar 16 1000/3000

Control Methods V/Hz or V/Hz V/Hz V/Hzopen loop vector

PID PID PID Option for PI PID (M3000)Energy Saver Standard N/A N/APreset Speeds 17 7 Option for 4 4Low Noise Operation up to 10 kHz 4.0 kHz 5 or 10 kHz upto 8 kHzAnalog Inputs 2 2 2 1Analog Outputs 1 1 1 1Digital Inputs 7 + Pulse Train 5 3Digital Outputs 3 2 2 3RS-422/485 port Standard Option Option StandardKeypad / Operator 4 digt, 7 segment LED Digit Keypad Option 16 character

display w /speed pot back lit LCD

YASKAWA

VS-606 V7 Our StrengthsVS-606 V7 Our Strengths

Features/functions Yaskawa TB WoodsVS-606 V7 E-Trac-XFC

Control Methods V/Hz or voltage vectoropen loop vector

PID PID N/AEnergy Saver Standard N/APreset Speeds 17 8Low Noise Operation up to 10 kHz 9.2 kHzAnalog Inputs 2 3Analog Outputs 1 1Digital Inputs 7 + Pulse Train 15 LogicDigital Outputs 3 Inputs/OutputsRS-422/485 port Standard N/AKeypad / Operator 4 digt, 7 segment LED Optional: 6 digit

display w /speed pot backlit LCD

YASKAWA

VS-606 V7 Key BenefitsVS-606 V7 Key Benefits

Globally Designed AC Drive Global package/construction CE Mark and UL/cUL Recognized

Compact Size Small package w/o sacrificing noise Smaller than previous generations Space Saving Design

YASKAWA

V7-606 V7 Key BenefitsV7-606 V7 Key Benefits

Cost Savings Quality

Proven Power Section Design (Mature) Mean Time Between Failure (MBTF)

exceeds 28 years

YASKAWA

VS-606 V7 Key BenefitsVS-606 V7 Key Benefits

Custom Capabilities Custom Programming Area* Special Application Area* Customer Specified Drive* Keep Customer Current w/ latest software

via fast download program

* Available in the future

YASKAWA

VS-606 V7 Key BenefitsVS-606 V7 Key Benefits

Network-ability Open Architecture support Network Interfaces Full Line of Network cards (in the near

future) Efficient Control Method

Open Loop Vector Optimized Current Control

YASKAWA

VS-606 V7 Target ApplicationsVS-606 V7 Target Applications

Textile Machines Conveyors Machine Tool Grinders Material Handling Equipment Fans and Pumps Mixers