Summary:

This document describes how to analyze

performance on an IBM Storwize V7000.

Page 2: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 2

This white paper was prepared by:

IntelliMagic B.V.

Leiden, The Netherlands

Phone: +31 71 579 6000

IntelliMagic, Inc.

Texas, USA

Phone: +1 214 432 7920

Email: [email protected]

Web: www.intellimagic.net

Disclaimer

This document discusses storage performance analysis for IBM Storwize V7000® storage

systems.

IntelliMagic products can be used to support all phases of the storage performance management

processes. Appropriate usage and interpretation of the results of IntelliMagic products are the

responsibility of the user.

Support

Please direct support requests to [email protected].

Please direct requests for general information to [email protected].

Trademarks

All trademarks and registered trademarks are the property of their respective owners.

© 2012 IntelliMagic B.V.

Page 3: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 3

Table of Contents

Section 1. Introduction .......................................................................................................................................... 4

1.1 I/O Path ...................................................................................................................................................................... 4

Section 2. IBM Storwize V7000® Architectural Overview and Measurements ................................. 5

2.1 IBM Storwize V7000® Architecture Overview ............................................................................................. 5

Measurement Overview ...................................................................................................................................... 6

2.2 I/O Group .................................................................................................................................................................. 7

Measurements ......................................................................................................................................................... 7

2.3 Nodes .......................................................................................................................................................................... 7

Measurements ........................................................................................................................................................ 8

Cache ........................................................................................................................................................................... 9

Cache Measurements .......................................................................................................................................... 10

2.4 Ports ........................................................................................................................................................................... 11

2.5 Internal RAID Groups or External Managed Disks .................................................................................... 11

Managed Disk Measurements........................................................................................................................... 11

2.6 Internal Disk .......................................................................................................................................................... 14

Disk Measurements .............................................................................................................................................. 14

2.7 Storage Pool ........................................................................................................................................................... 15

Storage Pool Measurements ............................................................................................................................. 16

2.8 Volume .................................................................................................................................................................... 16

Measurements ....................................................................................................................................................... 17

2.9 Thin Provisioning ................................................................................................................................................ 18

2.10 Easy Tier ................................................................................................................................................................ 18

Section 3. Conclusion ........................................................................................................................................... 20

Additional Resources .................................................................................................................................................... 21

Page 4: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 4

Section 1. Introduction The purpose of this paper is to provide a practical guide for conducting performance analysis on

an IBM Storwize V7000®. This paper will discuss the end-to-end I/O path, the Storwize V7000

architecture, and key Storwize V7000 measurements. In addition, it will provide guidance in

diagnosing and resolving performance issues using IntelliMagic products such as IntelliMagic

Vision and IntelliMagic Direction.

IntelliMagic Vision and IntelliMagic Direction are part of the IntelliMagic Storage Performance

Management Suite. For additional information on these software products, please refer to

http://www.intellimagic.net/intellimagic/products.

1.1 I/O Path

Figure 1: End-to-End View illustrates how I/Os traverse the I/O path. At its simplest level, any

host initiated I/O request is either a read or a write. The host device driver instructs the host bus

adapter (HBA) to initiate communication with the IBM Storwize V7000® fibre channel ports. The

connectivity equipment, such as the SAN switches and directors, confirm access and send the

packet to the destination fibre ports on the IBM Storwize V7000. If the data requested by the

host resides within the V7000 cache, then the data is sent back across the fabric and to the host.

If the data requested by the host does not reside within the IBM Storwize V7000’s cache, the IBM

Storwize V7000 requests it from its local disks, or the back-end storage array associated with the

volume. A detailed discussion of the read and write paths for different types of I/O will be

discussed in the cache section.

Figure 1: End-to-End View

Page 5: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 5

Section 2. IBM Storwize V7000® Architectural Overview and

Measurements

This section contains a brief overview of the IBM Storwize V7000 components and their relevant

measurements. For an in-depth discussion on the IBM Storwize V7000 architecture and

performance considerations see the references in the Additional Resources section of this paper.

2.1 IBM Storwize V7000® Architecture Overview

The IBM Storwize V7000 is a storage system residing in the I/O path between the host and the

back-end storage as illustrated in Figure 1: End-to-End View. It leverages software from the IBM

SAN Volume Controller® (SVC), IBM XIV, and IBM DS8000® series to provide block level storage

virtualization, and automated storage tiering for either internally or externally managed drives.

Typically the IBM Storwize V7000 includes internal disk drives, but in some environments it may

also be used to virtualize external storage. The IBM Storwize V7000 can support up to 32 PB of

externally managed storage.

The advantage to virtualizing the back-end storage arrays is that it facilitates centralized

migrations, provisioning, and replication. The virtualization and pooling of traditional storage

may also lead to improved capacity utilization, as well as performance improvements, as I/O can

be easily balanced across the back-end resources.

An IBM Storwize V7000 consists of two or four hardware components called nodes or node

canisters. Each pair of nodes is known as an I/O group, and it may contain up to twenty disk

storage enclosures. The I/O group consists of two redundant, clustered nodes. At the time that

this document was published, each node consists of an Intel chipset, 8 GB of memory, four 8

Gbps fibre channel ports, two Ethernet ports, two USB 2.0 ports, two 6 Gbps SAS ports, and either

12, 3.5 inch drives, or 24, 2.5 inch drives. The Storwize V7000 supports up to eighteen disk

expansion enclosures each containing either 12, 3.5 inch drives or 24, 2.5 inch drives. The physical

components of IBM Storwize V7000 are commodities. The uniqueness of IBM Storwize V7000 is

in the software and the logical components that will be discussed in the remainder of this

section.

Figure 2: IBM Storwize V7000® Components illustrates the IBM Storwize V7000 components.

Working our way from the bottom of the diagram to the top of the diagram, the LUNs can be

from internal storage system RAID groups or external storage system LUNs. The IBM Storwize

V7000 manages these objects as managed disks (mdisks). Each mdisk consists of a number of

extents of a specified size (default 256 MB). The mdisks are grouped together to form storage

pools. Once part of the storage pools, the extents are grouped to form volumes. Hosts are zoned

to the nodes which have access to all the volumes within the storage pools. The volumes are

assigned to the hosts. The individual components, how they relate to each other, and their

associated measurements will be discussed in more detail in the remainder of this section.

Page 6: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 6

Figure 2: IBM Storwize V7000® Components

Measurement Overview

Both front-end and back-end measurements are available for read response times, write

response times, read I/O rate, write I/O rate, read throughput, and write throughput. Front-end

only metrics include write cache delays, and read hit percentage for the I/O groups and nodes.

Back-end only metrics include read queue time and write queue time. Users who are familiar

with the measurements available for the IBM SAN Volume Controller® (SVC) will find nearly

identical measurements for the IBM Storwize V7000®. The V7000 also includes statistics on the

physical disks internal to the controller.

Figure 3: V7000/SVC Multi-Chart Performance Overview illustrates how one might track key

performance indicators for their IBM Storwize V7000.

Page 7: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 7

Figure 3: V7000/SVC Multi-Chart Performance Overview

2.2 I/O Group

The I/O group is a logical entity that refers to a pair of redundant clustered controller nodes or

controller node canisters. If one node fails within the I/O group, its workload will be transferred

to the other node. Hosts should be zoned to both nodes within the I/O group so that a node

failure does not cause a host’s volumes to become inaccessible.

Within an I/O group, a volume is associated with a preferred node. In normal operations, the

preferred node services all the I/Os for a given volume. The preferred node can be selected at

volume creation. By default, the IBM Storwize V7000® attempts to distribute the volumes evenly

across the nodes. If a preferred node is not manually selected, the IBM Storwize V7000 will

assign the volume to the node with the fewest volumes. As with host workloads, volume

workloads can vary dramatically. If one node is more heavily utilized than the other node, the

preferred node can be manually changed for a specific volume.

Measurements

The IBM Storwize V7000 aggregates volume measurements such as response times, throughput

and I/O rates to the I/O group. The read response time, and write response times for the volumes

associated with the I/O group represent the average amount of time required for IBM Storwize

V7000 to service the workload. Acceptable I/O response times will vary depending on application

and user requirements, the IBM Storwize V7000 hardware, the IBM Storwize V7000 firmware,

and back-end storage hardware and configuration. In addition to monitoring the I/O response

times, the read and write I/O rates and throughput should be monitored to understand if the

workload is balanced across the I/O groups and the nodes and if the workload is approaching the

limits of the I/O group.

2.3 Nodes

The nodes run the IBM Storwize V7000 software and provide I/O processing, memory buffering,

and connectivity. The IBM Storwize V7000 nodes utilize off the shelf Intel processors, memory,

network, and fibre channel ports. The processors provide the compute power for processing all

Page 8: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 8

the I/O operations. The memory serves as both a read and write I/O cache. The Ethernet ports

enable iSCSI host connections while the fibre ports provide fibre connectivity between the

attached hosts, IBM Storwize V7000®, and externally managed storage systems. The selected

connectivity medium can also enable communication between peer IBM Storwize V7000 clusters

for replication activities.

Measurements

The IBM Storwize V7000® provides a robust set of measurements for both the front-end, and

back-end measurements, as well as individual node CPU utilization. The node CPU utilization is

illustrated in Figure 4: Node Utilization.

Perhaps the only shortcoming of the IBM Storwize V7000 node metrics is the lack of visibility into

the internal bandwidth utilization; however, IntelliMagic

Direction may be used to estimate these metrics as

shown in Figure 5: IntelliMagic Direction Internal

Components.

Data throughput and I/O rate per port are required to

understand the port utilizations. The IBM Storwize

V7000 provides response times for each of the volumes

associated with the node from the viewpoint of the host

to the IBM Storwize V7000. These can be rolled up at the

node level to provide a view of the latency for any

particular node.

Tip #1: When planning connectivity requirements ensure that there are adequate bandwidth

and processor resources on the IBM Storwize V7000 ports to handle all the read hits, writes, and

the read misses. The read miss payload and the write payload must be staged and destaged to

Storwize V7000 cache from the internal disks or external storage controllers, and sent out to the

host over the same ports, effectively doubling the port bandwidth requirement for read miss

workloads and write workloads.

Figure 4: Node Utilization

Figure 5: IntelliMagic Direction Internal Components

Page 9: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 9

Cache

The primary purpose of cache is to reduce the host I/O response time. This is achieved by

providing cache hits for read requests, and buffering of fast cache writes.

The entire cache on an IBM Storwize V7000® node can be used for read or write activity. If all the

cache is consumed by write activity, and draining writes to the back-end storage is slow, the

system will go into write-through mode. This allows for unwritten write data to be drained to

internal storage in the case of a power outage.

Cache on an IBM Storwize V7000 is segmented into 4 KB segments or pages. A track is used to

describe the unit of locking and de-stage granularity. There are up to eight 4 KB segments in a

track. The IBM Storwize V7000 attempts to coalesce multiple segments into a track destage

when the segments to be written are within the same track.

Read I/O requests are either read cache hits or read cache misses. If the requested data is

resident in cache, the data is immediately transferred to the requestor from memory. This is

called a read cache hit and avoids back-end disk access. If the requested data is not resident in

cache, the data is requested from the internal disk drives or the external storage systems. This is

called a read cache miss. After the data is loaded into cache from internal drives or the external

storage system, the front-end adapter sends it to the host that initiated the request.

For write I/O requests, the data is written to cache on the host’s preferred node. It is then

mirrored to the partner node to provide resilience in the event of a node failure. Subsequently,

the preferred node sends an acknowledgement to the host that the I/O has been completed. This

is called a fast write (FW). At some point after the acknowledged completion of the I/O, the write

is destaged to the internal drives or external storage system. The tracks are marked unmodified

at this point and will stay in cache until they are moved out of cache by the controller using an

LRU algorithm. Assuming there is sufficient free write cache on the external storage system, the

write response times to external storage systems should be fast writes. This latency is not

accumulated on the front-end response time; rather it is associated with the mdisk latency as

will be discussed further in the mdisk section.

In the event of a node failure, all the modified cache from the remaining node will be drained to

the internal drives or external storage system. The behavior of write I/Os in this scenario will

change to write through mode. The acknowledgement from an IBM Storwize V7000® to the host

that a write has been completed will only be sent upon confirmation that the write has been

completed to the internal drives or acknowledged as completed by the back-end storage system.

Tip #2: Consider running your nodes and their associated components at no more than 50%

utilization during online periods. That way if you have a node failure, your cluster will not

severely impact the performance of your online applications.

Page 10: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 10

Cache is also managed at the storage pool level. This is referred to as partitioning. There is an

upper cache limit set for each of the storage pools. This prevents a single pool from getting more

than its fair share of cache. The upper cache limit depends on the number of storage pools. If the

cache limit is reached for I/Os to a particular storage pool, write I/Os will behave in a write

through mode. This behavior will only continue while the amount of cache consumed for write

I/Os to a specific storage pool exceeds the upper limit. As discussed previously, this has the effect

of requiring write I/Os to be completed to internal drives or acknowledged by the external

storage system prior to informing the initiator that the write has been completed. It is rare to

encounter this behavior unless there is a problem draining writes to an external storage system

due to overutilization, or a problem within the storage system.

Cache Measurements

From a performance analysis perspective, it is important to understand the effectiveness of the

cache management. Key cache measurements include the read cache hit ratios, and the write

cache delays. Consistent low read cache hit ratios may indicate that the storage system has

insufficient cache for the workload. These metrics are available at the IBM Storwize V7000® I/O

group, node, partition, and volume level. They can be rolled up at the storage pool level as

illustrated in Figure 6: Read Hit % vs I/O Rate.

Figure 6: Read Hit % vs I/O Rate

Tip #3: For open systems workloads, an average read cache hit ratio greater than 50% is desired.

IntelliMagic Direction can help identify whether additional cache will help improve the response

time or throughput for a particular workload. For certain workloads that have very random read

access patterns it may be completely acceptable to have a read cache hit ratio much lower than

50%.

The number of write cache delays per second indicates whether or not the IBM Storwize V7000 is

able to destage I/Os quickly enough to the back-end storage system. A write delay event

indicates that cache is full, and that new write I/O operations may only be completed after a

physical destage to disk frees up space. This typically only happens when the internal drives or

external storage system is saturated.

Page 11: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 11

Tip #4: A small number of write delays can significantly increase write response times to hosts.

2.4 Ports

There are fibre channel and Ethernet ports on the nodes. All traffic from hosts, between nodes,

and to external storage systems passes through the node’s ports. Measurements include read

and write throughput, and read and write operations to and from hosts, other SVC nodes, and

external controllers. It is important to keep the node port throughput balanced and less than

50% utilized in case there is a node failure. Figure 7: Fibre Host Read MB/sec Balance Chart

illustrates how balanced the ports are on a V7000 cluster. Each bar represents a single fibre

channel port. The average read mb/sec, standard deviation and minimum/maximum values

provide the analyst a quick view of how well balanced port activity is across the entire cluster.

Figure 7: Fibre Host Read MB/sec Balance Chart

2.5 Internal RAID Groups or External Managed Disks

A managed disk has a one-to-one relationship with a back-end storage system LUN or internally

managed RAID group. There should also be a 1:1 relationship between externally managed LUNs

and their supporting RAID groups. This section uses mdisk to refer to both the internally

managed RAID groups and the external managed disks.

Managed Disk Measurements

You can monitor the performance of your managed disks using the managed disk statistics that

include both the internal RAID group and external mdisk read and write response times. These

statistics measure the amount of time required to perform a read or write operation from the

Storwize V7000 to internal RAID groups or the external mdisk. For externally managed mdisks,

read and write queue times measure how long read or write operations are waiting to be sent to

the back-end storage system or internally managed drives.

Tip #5: Average external mdisk queue times should be less than a couple of milliseconds as the

Storwize queue times only measure the amount of time the I/O request spends waiting to be

Page 12: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 12

sent to the internal disk or external storage systems. If this is over 1.0 ms, it is a sign of

contention on the fabric or on the back-end internal disks or external storage system.

Figure 8: External Write Queue Time illustrates a situation where the external write queue time

is exceptionally high.

Figure 8: External Write Queue Time

Tip #6: For increases in front-end response time that do not correlate to increases in the RAID

group or external mdisk response times, the performance issue is with the path from the host to

the Storwize V7000 or the Storwize V7000’s ports or processors.

Tip #7: Average mdisk response times greater than 12.0 ms for fibre channel drives and 15.0 ms

for SATA drives indicate some sort of constraint within the Storwize V7000 to the internally

managed drives, or for externally managed mdisks it indicates a problem along the path or

within the external storage system. The expected response times will vary depending on the

exact configuration.

Page 13: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 13

Figure 9: Managed Disks External Read Response Time SLA Chart illustrates a situation in which

the read response times to a significant number of the mdisks is exceeding desirable service

levels.

Figure 9: Managed Disks External Read Response Time SLA Chart

In order to understand if high back-end response times on the Storwize V7000 are a result of

saturated internal disk RAID groups or an external storage system component, you will need to

have visibility into the storage system’s components. For supported platforms, IntelliMagic

Vision provides end-to-end visibility into both the internal RAID groups and the external storage

system components.

When vendors describe I/O response times they typically mean weighted averages similar to

what is described in Example 1: Average Response Time.

Example 1: Average Response Time

Workload Type: OLTP

Read / Write Ratio: 80/20

Read Hit Ratio: 50%

Write Hit Ratio: 100%

Write Hit Response Time: 1.0 ms

Read Hit Response Time: 1.0 ms

Read Miss Response Time: 6.0 ms

Read I/Os per Second: 800

Write I/Os per Second: 200

Average Response Time =

((400*1.0) + (200*1.0) + (400*6.0))/1000 = 3.0 ms per I/O

Page 14: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 14

2.6 Internal Disk

The IBM Storwize V7000® can have up to 240 3.5 inch drives or 480 2.5 inch drives. Table 1: Drives

Supported shows the drives currently supported:

Table 1: Drives Supported

Drive Type Speed (RPM) Size

2.5-inch form factor SSD N/A 200, 300, and 400 GB

2.5-inch form factor SAS 10,000 300,450, and 600 GB

2.5-inch form factor SAS 15,000 146 and 300 GB

2.5-inch form factor Nearline SAS 7,200 1 TB

3.5-inch form factor Nearline SAS 7,200 2 TB

Note: For the latest supported disk drives, please consult the IBM web site.

Disk Measurements

For each drive, the IBM Storwize V7000 provides read I/O, write I/O, read throughput, write

throughput, read response time, and write response time. From these metrics, disk utilization

can be calculated. Depending on the type of drive, you can expect different types of response

times. For an estimation of expected service times, you can refer to Table 2: Disk Service Time

Estimates:

Table 2: Disk Service Time Estimates

Drive

IOPS

(No

Queue)

Average Service

Time (ms)

SATA 7200 RPM 120 8.5

SAS/FC 10K RPM 167 6

SAS/FC 15K RPM 250 4

Page 15: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 15

Figure 10: Internal Disk Drive Utilization SLA Chart illustrates the utilization of all the internal

drives of a six-node SVC cluster. This is a good way to quickly identify and disk hot spots within

the internal drives.

Figure 10: Internal Disk Drive Utilization SLA Chart

2.7 Storage Pool

A storage pool is a grouping of more than one managed disk. When planning a storage pool it is

important to remember that when a single managed disk experiences a failure, it brings the

entire storage pool offline. As a result, one of the primary design goals is to limit the hardware

failure boundaries. General performance guidelines should also be addressed as part of the

design, and will also be discussed in this section. With these thoughts in mind, there are several

best practices to consider when creating a storage pool as enumerated in Table 3: Storage Pool

Best Practices.

Table 3: Storage Pool Best Practices

Best Practice Availability Performance A storage pool should utilize managed disks from one storage system. X Each external storage system should provide managed disks to a single

Storwize V7000 cluster. X

A V7000 can present storage to SVC, but a V7000 cannot present storage to

another V7000.

Each internal or external RAID group must be included in only one storage

pool. X

Rather than adding capacity to an existing storage pool, create a new

storage pool. X X

Implement striped volumes for all workloads except 100% Sequential. X For externally managed disks, utilize storage pools with at least eight

managed disks to take advantage of the round-robin distribution of I/O

workload to the external storage controller. X X

Select an extent size that balances cluster capacity and volume granularity.

Testing has shown good results with 128 MB and 256 MB extents. X

Page 16: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 16

Storage Pool Measurements

The storage pool measurements provide a good means for monitoring the performance of both

the front end (host to port) and the back end (cache to disk). The storage pool measurements

provide a combination of measurements that are aggregated from both the front-end volume

operations, as well as the back-end managed disks operations. On the front end, the response

times, I/O rates, and I/O throughput provide an excellent means for understanding if the storage

pools are responsive and balanced. The response times include the read cache hits as well as the

read cache misses. On a system with a normal read cache hit percentage, the average front-end

read response time will be understandably lower than the back-end read response times for the

same storage pool. The front-end write response times should generally be 1.0 ms or less as they

are only measuring the amount of time required to write to the preferred node’s cache and

mirror to the secondary node.

Figure 11: V7000 Read Response Time by Storage Pool

2.8 Volume

Storage pools are created from the storage provided by externally managed disks (mdisks) or

internally managed RAID Groups. The storage from the managed volumes are grouped together

and divided into extents. A volume is a discrete grouping of storage extents can be made

addressable to a host. The size of the extent can be selected during the storage pool creation but

the default size is 256 MBytes. When volumes are created the capacity and the layout of the

volume are selected. For IBM Storwize V7000® managed disks, the data layout can be striped or

sequential. In all cases but 100% sequential workloads, the volumes should be created as striped

volumes. Striped volumes consist of extents that are spread across the managed disks in a

round-robin fashion. Non-managed Storwize V7000 volumes or image-mode disks are not

covered in this paper as they not typically part of steady state configurations.

Table 4: vdisk Best Practices

Best Practice Management Availability

New vdisks should go to least utilized storage pool within cluster. X

Page 17: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 17

Vdisk size should be appropriate for hosts. For most hosts, fewer

larger vdisks work better from a performance and management

perspective. This should be balanced with the size and activity level

of the vdisk in relationship to the storage pool in which it resides. A

rule of thumb is the vdisk should not consume more than 10% of

the capacity of the storage pool nor should it consume more than

20% of the performance bandwidth of the storage pool.

X X

Use striped volumes even if application or host has its own striping

as long as stripe sizes are dissimilar. Fine-grained host LVM

striping can be beneficial for performance.

X

Set Thin Disk to auto-expand, so if allocated space is used the disk

doesn’t go offline if additional writes occur. X X

Measurements

In order to detect whether performance problems exist, it is important to ignore inactive

volumes, since those volumes have an insignificant impact on the overall performance of the

storage system. It is common for some of the volumes with the highest response time to have

little I/O activity. Sorting the volumes based on their response time alone, therefore, is not a good

way to find the volumes that cause bad overall performance. A good way to find the volumes

that have the biggest impact on the overall performance is to sort the volumes by their I/O rate

time's response time, which is called “I/O Intensity” as illustrated in Figure 12: Top Volume by I/O Intensity.

Figure 12: Top Volume by I/O Intensity

Response times for volumes are provided from the view of the front end of the IBM Storwize

V7000®, so they include both cache hits and cache misses. On a well balanced system that is not

overloaded, 100% of writes should be satisfied from cache. The response time for writes satisfied

from cache should be no more than the amount of time required to write to the target node’s

cache, mirror to the secondary node, and then send the host an acknowledgement.

Page 18: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 18

Read hits should also take very little time to process and transfer the data. For internally

managed disks, the read misses will require a physical disk access. For externally managed disks,

the read miss may be served from the externally managed controller’s cache or its back-end disk

drives if the requested tracks are not in cache. In either case, a read miss is significantly slower

than a read hit. Figure 13: v7000 vdisk Response Time illustrates the average vdisk response

time for the top 30 volumes.

Figure 13: v7000 vdisk Response Time

2.9 Thin Provisioning

Thin provisioning provides a mechanism to assign more logical capacity than physical capacity.

In a thin provisioning environment, only the portion of the LUN that is written to is actually used.

This means that if 1 GB of a 20 GB LUN is written to, then only 1 GB is in use. To accomplish this,

the extents are divided into smaller elements called grains. The grain size is configurable at the

storage pool or volume level. The default is 32 Kbytes. In a thin provisioned environment, only

the grains that are written to will be counted towards the amount of storage actually used by the

volume. The IBM Storwise V7000® tracks both the allocated and the used.

Tip #8: When you create a thin-provisioned volume, set the cache mode to readwrite to cache

metadata. This will reduce latency associated with I/Os to thin provisioned volumes as the

metadata will be cached.

2.10 Easy Tier

Easy Tier provides a mechanism to transparently migrate hot extents to the most appropriate

storage tier within an IBM Storwise V7000 environment. It evaluates the read miss activity of the

volumes within an Easy Tier enabled storage pool and moves the active extents to a higher disk

tier. The current implementation is designed to take advantage of a storage pool containing

mixed drive technology such as SSD and FC. Hot extents will be migrated to the SSD drives and

extents with low activity will be migrated to the slower and less expensive disk technology. The

migration does not take place between storage pools.

Page 19: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 19

The SSDs should be placed internally within the IBM Storwise V7000® even if the FC or SATA

drives are located externally. This will reduce the fabric overhead.

Tip #9: Set grain size for non flash copy thin volumes to 256 KB. For flash copy volumes, set the

grain size to 64 KB. Default is 32 KB! If you leave the grain size at 32 KB, EasyTier will assume that

it is not sequential I/O even when it is. This may result in sub-optimal data placement and

performance.

Page 20: WP-Storage Performance Analysis for an IBM Storewize V7000

© IntelliMagic 2012 Page 20

Section 3. Conclusion In this paper, we highlighted some of the architectural components of the IBM Storwize V7000®.

We also discussed some of their associated measurements. Finally, we utilized IntelliMagic

Vision to examine several of the key performance metrics for the IBM Storwize V7000 storage

system performance. Using IntelliMagic Vision we were able to easily identify imbalances and

service level exceptions.

We realize that many subjects were greatly simplified, and understand that becoming an expert

in storage performance management requires significant real world experience that cannot be

obtained by reading a white paper. Here at IntelliMagic, we strive to make storage performance

management easier by providing world class solutions, support, training, and services. Next

time you need some guidance on storage performance issues, feel free to contact us for a free

performance analysis at [email protected].