work on flat roofs
TRANSCRIPT
-
8/17/2019 Work on Flat Roofs
1/2
[Member Company Name]Standard Risk
Assessment
ROOF – 005a
Operation: Work on Flat Roofs
Potential
Hazards:
• Fall of persons or materials from height.
• Fall of persons or materials through fragile material.
•
Falls of persons or materials through roof openings.• Bitumen boilers.
• Fire
• Unauthorised access to the ork area.
• !anual handling of materials.
Persons
"#ected:
Operati$es % &ite
Workers
'lient
&ta# ☐Public ☐
'ontrol
!easures
( "ll roof ork sites ill be full) sur$e)ed b) a trained* competent person prior to an) orkcommencing and ill include assessment of ad$erse eather conditions and o$erhead
ser$ices or other hazards. &hould an) o$erhead ser$ices e+ist on site* H&, document -&
and the local utilit) compan) must be consulted.
/ " ritten 0safe s)stem of ork1* detailing all ork procedures* ill be prepared b) a
trained* competent person and kept on site* readil) a$ailable to all concerned parties for
reference purposes. " standard procedure ma) be adopted or adapted.
2 3he site orks are to be controlled and coordinated b) a competent person at all times.
4 "ll operati$es engaged ithin the ork acti$it) ill be competent for their allotted task.
5 "ll roof openings* hen not orked on* ill be co$ered and%or guarded and clearl)
delineated. 'o$ers should be 6tted to the e+ternal of the roof and be greater in size thanthe opening. Pl)ood or similar materials must be of su7cient strength to hold the eight
of a person or materials.
Full edge protection ill be 6tted on all roof ele$ations to hich access is needed here
there is a risk of a person or materials falling a distance liable to cause personal in8ur).
9 Where independent sca#old edge protection is not reasonabl) practicable* barriers high
and strong enough to stop a person rolling or sliding don a roof slope* ill be attached to
the structure.
" competent person ill carr) out the statutor) inspections of sca#olds and maintain a
ritten record of such inspections:
1. Before initial use/. At regular intervals, not exceeding 7 days from the last inspection; and2. After any substantial alteration or after any event likely to have aected the
scaold strengthstability.
; "ppropriate and su7cient personal protecti$e e
-
8/17/2019 Work on Flat Roofs
2/2
(
/
Barriers ill be erected and arning signage to be displa)ed to pre$ent unauthorised
access to the ork area.
(
2
'onstruction $ehicles and e