Wood-Frame Shear Wall and Diaphragm Design Ricky McLain, MS, PE, SE Technical Director – WoodWorks Chicago Area Workshops – April, 2017

Upload: others

Post on 05-Aug-2020

5 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Wood-FrameShearWallandDiaphragmDesign

RickyMcLain,MS,PE,SE

TechnicalDirector– WoodWorks

ChicagoAreaWorkshops – April, 2017

Page 2: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Overview

• Diaphragms

• Shearwalls

Page 3: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmDesign

Page 4: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

WindLoadDistributiontoDiaphragm

WINDINTODIAPHRAGMS

WINDSURFACELOADSONWALLS

Page 5: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

WindLoadPaths

WINDINTODIAPHRAGMSASUNIFORMLINEARLOADS

Page 6: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

WindLoadPaths

DIAPHRAGMSSPANBETWEEN

SHEARWALLS

WINDINTOSHEARWALLSASCONCENTRATEDLOADS

Page 7: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

StudtoDiaphragm

WINDLOAD

DIAPHRAGMSHEATHING

Floor/Roofframing

perpendiculartowalls

FLOORJOIST

Page 8: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

StudtoDiaphragm

WINDLOAD

DIAPHRAGMSHEATHING

Floor/Roofframing

paralleltowalls(addblocking)

FLOORJOIST

BLOCKING

Page 9: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

CalculatingDiaphragmForces

AWCDesignAid6

MaxShearatEnds

MaxMoment

atMid-Span

Page 10: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

CalculatingDiaphragmForces

AWCDesignAid6

DiaphragmShear:• MaxShear=Diaphragm

ReactionatShearwall• DiaphragmUnitShear=

Reaction/LengthofDiaphragm=plf

Page 11: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

UnblockedDiaphragm

Page 12: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

UnblockedDiaphragmCapacity

• CapacitiesinSDPWSareNominal values.NotASDDivideNominalValuesby2.0forASDCapacity

MultiplyNominalValuesby0.8forLRFDCapacity

• CapacityisreducedforspecieswithSpecificGravity<0.5

• ForSprucePineFirmultiplyby0.92

Page 13: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

BlockedDiaphragm

Page 14: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

BlockedDiaphragmCapacity

• CapacitiesinSDPWSareNominal values.NotASDDivideNominalValuesby2.0forASDCapacity

MultiplyNominalValuesby0.8forLRFDCapacity

• CapacityisreducedforspecieswithSpecificGravity<0.5

• ForSprucePineFirmultiplyby0.92

Page 15: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ShearWallCapacitiesinAWCSDPWS

UnblockedBlocked

Page 16: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmTypes

CASE1DIAPHRAGM

•HigherShearValues•Panelsperpendiculartofloorframingfor

improvedperformance

CASES2-6Maybepreferred

forlowsheardemandwhere

changingframingdirection

helps

•HVACruns•FireBlocking/DraftStopping

RoofTrusses4x8sheathingN-S

Page 17: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmTypes

SDPWSTables4.2A&B

Page 18: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmAspectRatio

SDPWSTable4.2.4

Page 19: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

CalculatingDiaphragmForces

24’

72’

Diaphragm Fastener Schedule

Zone A12’

Zone A 12’Zone B 48’

Page 20: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Diaphragm– BendingMember

Tensionedge

Compressionedge

Page 21: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmChordForces

AWCDesignAid6

DiaphragmChordForces:• MaxChordForceOccursat

LocationofMaxMoment• ChordForce=TorC• ChordForce=MMAX /

DiaphragmDepth• ChordUnitShear=ChordForce

/LengthofDiaphragm=plf

Page 22: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmChords

WallTopPlatesTypicallyFunctionasBothDiaphragmChordsandDragStruts

Page 23: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmBoundary

Strut

Strut

Cho

rdC

hord

Strut

Cho

rd

SW1 – 10’ SW2 – 10’

SW3 – 16’

1 2 3

B

A

Strut

Stru

t

W =

200

plf

24’

80’

Reaction = 200 plf * 24’/2 = 2400 lbsDiaphragm Only at Shearwall = 2400 lbs / 16’ = 150 plf

Page 24: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmBoundary

Strut

Strut

Cho

rdC

hord

Strut

Cho

rd

SW1 – 10’ SW2 – 10’

SW3 – 16’

1 2 3

B

A

Strut

Stru

t

W =

200

plf

Does this mean that no drag struts are required?

24’

80’

Page 25: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmBoundary

Alledgesofadiaphragmshallbesupportedbyaboundaryelement.(ASCE7-10Section11.2)

• DiaphragmBoundaryElements:• Chords,dragstruts,collectors,Shearwalls,frames

• Boundarymemberlocations:• Diaphragmandshearwall perimeters• Interioropenings• Areasofdiscontinuity• Re-entrantcorners.

Page 26: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

AssumeBasicWindSpeed=115mphUltimate

ExposureB

DiaphragmDesign

• Capacity

Shearwall Design

• Conventional• ForceTransferAroundOpening• PerforatedShearwall

Example:RetailRestaurant

Page 27: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

RetailRestaurant– DiaphragmDesignCriticalShearwall atfrontofbuilding

CheckDiaphragmforwindloadson84’wall

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’

3’3’

4’

29’24’

Page 28: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmAspectRatios

SDPWSTABLE4.2.4

TYPE- MAXIMUMLENGTH/WIDTHRATIO

Foran84x34diaphragmtheaspectratiois2.5<3.

DiaphragmaspectratioisOK.

Woodstructural panel,unblocked 3:1

Woodstructural panel,blocked 4:1

Single-layerstraightlumbersheathing 2:1

Single-layerdiagonallumbersheathing 3:1

Double-layerdiagonallumbersheathing 4:1

Page 29: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

CalculatingMWFRSWindLoadsCalculatewindpressureusingDirectionalMethod(ASCE7Chpt 27)

p=qh[(GCpf)-(GCpi)]

qh =0.00256*0.57*1.0*0.85*1152*1=16.4psf

GCpf =0.85*[0.8– (-0.3)]=0.935

GCpi =0.18- 0.18=0

p=(16.4psf)(0.935)=15.34psf

0.6*W=0.6*15.34=9.2 psf onwalls

Usemin9.6psf perASCE27.1.5

ASCE7-10Figure27.4-1

Page 30: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ParapetDesign– Figure27.6-2

Atparapetswindward

andleewardpressures

occuroneachparapet.

Section27.4.5:Pp =q(GCpn)GCpn =1.5Windwardparapet,-1.0LeewardparapetWindwardParapetGCpf is1.5:16.4*1.5*0.6=14.76psf

LeewardParapetGCpf is1.0:16.4*1.0*0.6=9.84psf

NetParapet=14.76+9.84=24.6psf

Page 31: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

RetailRestaurant– DiaphragmDesign

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’4’

29’24’

10’

3’

3’

W=(9.6psf*(5’+3’)+(24.6)*3’)=150.6plfV=(150.6plf)*(84’/2)=6,325lbM=(150.6plf)*(84’2)/8=132,829lb*ft

T=C=(132,829lb*ft)/(34ft)=3,907lb

νdiaphragm =6,325lb/34’=186plfνdiaphragm =3,907lb/84’=47plf

P

Page 32: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

DiaphragmCapacity:SDPWSTable4.2C

PANEL

GRADE

COMMON

NAILSIZE

ORSTAPLEf

LENGTHANDGAGE

MINIMUM

FASTENER

PENETRATION

INFRAMING

MINIMUM

PANEL

THIICKNESS

MINIMUM

NOMINALWIDTHOFFRAMINGMEMBERSAT

ADJOININGPANELEDGESAND

BOUNDARIESg

NAIL

SPACING

ATALL

PANEL

EDGES

Case1

(Nounblocked

edgesor

continuous

jointsparallelto

load)

Allother

configurations

(Cases2,3,4,5

and6)

Sheathing

&single

floor

8d(2½“x

0.131”)

13/8”

7/16”

2IN. 6IN. 460(Seismic)

645(Wind)

340(Seismic)

475(Wind)

3IN. 6IN. 510(Seismic)

715(Wind)

380(Seismic)

530(Wind)

CapacityisreducedforspecieswithSpecificGravity<0.5.

ForSprucePineFirmultiplyby0.92

Capacity =(645plf)(0.92)/2=297plf297plf >186plf,diaphragmisadequatewithsheathing&fasteningasshownabove

Page 33: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

SmallOpeningsinDiaphragms

http://cwc.ca/wp-content/uploads/2013/11/Design-example-of-

designing-for-openings-in-wood-diaphragm.pdf

Accountingforopeningsinshearpanels(diaphragmsandshear

walls)isacoderequirement(IBC2305.1.1)

Nocodepathforcheckingminimumsizeopeninglimit(otherthan

prescriptivedesign– IBC2308.4.4.1&2308.7.6.1)

Doyouneedtoaccountfora

12”squareopeninginadiaphragm?

Page 34: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

SmallOpeningsinDiaphragms

FPInnovationsmethodforcheckingsmallholesindiaphragms:

Recommendrunningananalysisoftheopening’seffectsonthediaphragmunlessthefollowingconditionsaremet.

Page 35: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Overview

• Diaphragms

• Shearwalls

Page 36: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

WindLoadscreateshear(sliding)andrackingforcesonastructure

Slidingresistedbyshearwall baseanchorageRackingresistedbyshearpanel&fasteners

Shearwall Functions

Page 37: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ComponentsofShearWallDesignCollector&Drag

Design

ShearWallConstruction

ShearTransferDetailing

ShearResistance

Page 38: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ShearWallConfigurationOptions

SolidorSegmentedWalls

PerforatedWallsForceTransferAround

OpeningsWalls

MaximumASDCapacityof870plf (Seismic)1217plf (Wind)

Useful,If Necessary.

Page 39: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwalls

HOLD-DOWN

WSPSHEATHING

ANCHORBOLTS

WOODSTUDS

Page 40: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

RackedShearwall

EDGENAILINGPROVIDESRACKINGRESISTANCE

Page 41: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

PanelFasteners

Page 42: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwalls

ANCHORBOLTSTOFOUNDATION

PREVENTSLIDING!

Page 43: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Hold-DownsResistEndUplift

HOLD-DOWNS

Page 44: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ShearWallRequirementsinAWCSDPWS

3:5:1maxaspectratioforblockedWoodStructural PanelShearWall.

Reduction inCapacitywhengreaterthan2:1

WoodEducation Institute

Page 45: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwall AspectRatio

NDSSDPWSTABLE4.3.4

MAXIMUMSHEARWALLDIMENSIONRATIOS

SeeSDPWSTable4.3.4forfootnotes

Woodstructural panels,blocked Forotherthanseismic:3½:11

Forseismic:2:11

Woodstructural panels,unblocked 2:1

Diagonalsheathing, single 2:1

StructuralFiberboard 3½:13

Gypsumboard,portland cementplaster 2:12

L

H

AR=H/L

Page 46: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

WSPShearwall Capacity• CapacitieslistedinAWC’sSpecialDesign

ProvisionsforWindandSeismic(SDPWS)

• Sheathedshearwallsmostcommon.Canalsousehorizontalanddiagonalboardsheathing,gypsumpanels,fiberboard,lathandplaster,andothers

• Blockedshearwallsmostcommon.SDPWShasreductionfactorsforunblockedshearwalls

• Notethatcapacitiesaregivenasnominal:mustbeadjustedbyareductionorresistancefactortodetermineallowableunitshearcapacity(ASD)orfactoredunitshearresistance(LRFD)

Page 47: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwall Capacity- SDPWSChpt 4

Page 48: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwall Capacity- SDPWSChpt 4

Page 49: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwall Capacity- SDPWSChpt 4

Capacitybasedonblockedshearwall.

Reducecapacitiesforunblocked

Page 50: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ComponentsofShearWallDesign

Holdown

Anchorage

BoundaryPosts

Compression

Tension

Page 51: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwall HoldDowns

Straps

Source:strongtie.com

Page 52: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwall HoldDowns

Source:DartDesignInc.com

Source:strongtie.com

BucketStyle

Page 53: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ComponentsofShearWallDesign

Accumulatedtensionfromframingtohardwaretoframingateachfloorlevel

1kip

2kips

3kips

7k

4k

1.5k 1.5k

1.5k

4k

4k

7k

7k

Overturningrestrained

connectionatbottomofstory

20ft

10ft,typ

DiscreteHoldown Systems

Page 54: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ComponentsofShearWallDesignCollector&Drag

Design

ShearWallConstruction

ShearTransferDetailing

ShearResistance

Page 55: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ShearTransferDetailing

Source:WoodWorks Five-Story

Wood-Frame Structureover

PodiumSlabDesignExample

Page 56: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ShearTransferDetailing

Source:WoodWorks Five-StoryWood-Frame

StructureoverPodiumSlabDesignExample

Designacompleteloadpath

Page 57: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ComponentsofShearWallDesign

Collector&DragDesign

ShearWallConstruction

ShearTransferDetailing

ShearResistance

Page 58: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

LoadPath,LoadPath,LoadPath…IBC1604.4Analysis. Loadeffectsonstructuralmembersandtheirconnectionsshallbe

determinedbymethodsofstructuralanalysisthattakeintoaccountequilibrium, general stability,

geometriccompatibilityandbothshort- andlong-termmaterialproperties.

[…]

Anysystemormethodofconstructiontobeusedshallbebasedonarationalanalysisin

accordancewithwell-established principlesofmechanics.Suchanalysisshallresultinasystemthatprovidesacompleteloadpathcapableoftransferringloadsfromtheirpointoforigintotheload-resistingelements.

Resources:

TheAnalysisofIrregularShapedDiaphragms. WhitepaperbyR.TerryMalonehttp://www.woodworks.org/wp-content/uploads/Irregular-Diaphragms_Paper1.pdf

TheAnalysisofIrregularShapedStructures.TextbookbytheR.TerryMalone

NEHRPSeismicDesignTechnicalBrief.SeismicDesignofWoodLight-FrameStructuralDiaphragmSystems:AGuideforPracticingEngineers

http://www.nehrp.gov/library/techbriefs.htm

Collector&Drag(Diaphragm)Design

Page 59: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

RetailRestaurant– Shearwall Design

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’4’

29’24’

10’

3’

3’

P =6,325lb – fromdiaphragmcalcs usingDirectionalMethod

Let’sseewhathappenswhenweuseEnvelopeMethodtocalculateMWFRSloadstofrontshearwall

P

Page 60: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

CalculatingMWFRSWindLoadsCalculatewindpressureusingEnvelopeMethod(ASCE7Chpt 28)

p=qh[(GCpf)-(GCpi)]

qh =0.00256*0.70*1.0*0.85*1152*1=20.14psf

GCpf (Zones1&4) =0.4– (-0.29)=0.69(ASCE7Fig.28.4-1)

GCpf (Zones1E&4E) =0.61– (-0.43)=1.04(ASCE7Fig.28.4-1)

GCpi=0.18- 0.18=0

P1&4=(20.14psf)(0.69)=13.9psf;0.6*W=0.6*13.9=8.3psfwallstyp.

P1E&4E=(20.14psf)(1.04)=20.9psf;0.6*W=0.6*20.9=12.5psf wallscrnr

ASCE7-10Figure28.4-1

Page 61: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

CalculatingMWFRSWindLoads

ASCE7-10Figure28.4-1

a=Lesserof:

• 10%leasthorizontaldimension(LHD)34’*0.1=3.4’

• 0.4h=0.4*13’=5.2’.Butnotlessthan:

• 0.04LHD=1.4’or3’

Usea=3.4’forzones1E&4E

2a=3.4’*2=6.8’

Page 62: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ParapetDesign– Section28.4.2

Atparapetswindward

andleewardpressures

occuroneachparapet.

Section28.4.2:Pp =q(GCpn)GCpn =1.5Windwardparapet,-1.0LeewardparapetWindwardParapetGCpf is1.5:20.14*1.5*0.6=18.12psf

LeewardParapetGCpf is1.0:20.14*1.0*0.6=12.08psf

NetParapet=18.12+12.08=30.2psf

Page 63: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

RetailRestaurant– Shearwall Design

84’

34’

10’6’ 8’5’

6’

6’

6’

6’

6’4’

29’24’

10’

3’

3’

P

6.8’12.5psf8.3psf

77.2’

P=(8.3psf*(5’+3’)+(30.2)*3’)*(84’/2)+((12.5psf-8.3psf)*(5’+3’))*6.8’*(77.2’/84’)=6,804lb(forcomparison:Directionalmethodgaveus6,325lb)

Page 64: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Shearwall AspectRatios

10’

3’

3’

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

• CheckAspectRatios:AssumeblockedWSPShearwall

• 10’/2’=5>3.5;Inadequate

• 10’/6’=1.67<3.5;OK

FrontWallElevation

Page 65: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

• CheckAspectRatios:AssumeblockedWSPShearwall

• 10’/2’=5>3.5;Inadequate

• 10’/6’=1.67<3.5;OK

Shearwall AspectRatios

10’

3’

3’

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =6,804lb/12’=567plf

Page 66: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ConventionalShearwall Capacities

νshearwall =567plf

Assume15/32”,StructuralIsheathingattachedwith8dnails

NominalTabulatedCapacity=1540plf

AdjustedASDCapacity =(1370plf)(0.92)/2=630plf630plf >567plf,OK

8dnailsat3”o.c.acceptable

PANELGRADE FASTENER

TYPE&

SIZE

MINIMUM

PANEL

THIICKNESS

MINIMUM

FASTENER

PENETRATION

INFRAMING

NAIL SPACING

ATALLPANEL

EDGES

PANEL EDGE

FASTENERSPACING

Wood Structural

Panels–

Sheathing

8d(2½“x

0.131”)

15/32” 13/8” 3IN. 980(Seismic)

1370(Wind)

SDPWSTable4.3A

Page 67: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ConventionalShearwall Overturning

νshearwall =567plfHolddownsrequiredatshearwalls

T=νhT=567plf*10’=5,670lb

Holddowncapacity=7,045lbManyavailableprefabricatedholddownswithcapacitieslistedbymanufacturers

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

Page 68: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Hold-DownAnchor

Page 69: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ConventionalShearwall Overturningνshearwall =567plfPostsarealsorequiredatendsofthewalltoresistcompressionforces

C=T=νhC=567plf*10’=5,670lb

6’ 6’ 6’ 6’ 6’2’ 2’

10’

SizepostforbearingonwallsoleplateAssume2x6wall,

Requiredpostwidth=5,670lb/(565psi)(5.5in)=1.8in;

Use2-2x6postmin.

Page 70: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ConventionalShearwall BaseAnchorage• νshearwall =567plf• ½”AnchorBoltcapacityforwoodbearing=680lb*1.6=1,088lb

perNDSTable11E

• Spacing=1088lb/567plf =1’-11”o.c.max.

Page 71: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Hold-Downs:Segmentedv.PerforatedSegmentedShearwall

PerforatedShearwall

Page 72: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

PerforatedShearWallMethod

HOLDDOWNSATENDOF

WALL

WSPSHEATHING

Fewerholddownsrequired,shearcapacityisreduced

Uniformupliftatbaseofwallrequired– magnitude=shearforce– SDPWS4.3.6.4.2.1

Page 73: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

• CheckAspectRatios:AssumeblockedWSPShearwall

• 10’/2’=5>3.5;Inadequate

• 10’/6’=1.67<3.5;OK

Useonlyfullheightsheathedsectionstoresistshear

PerforatedShearwall Design

10’

3’

3’34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =6,804lb/12’=567plf

TotalPerforatedShearwall

Page 74: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

PerforatedShearwall CapacityWallhas12’/18’=67%fullheightsheathing,max.openingH=6’-8”

Multiplycapacityby0.75foropening2H/3

Reducedcapacityis630plf*0.75=473plf <567plf,Inadequate

SDPWSTable4.3.3.5

Page 75: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

PerforatedShearwall Capacity

νshearwall =567plf

Tryreducingnailspacingto2”with8dnails– willrequire3xframing

NominalTabulatedCapacity=1790plf

AdjustedASDCapacity=(1790plf)(0.92)(0.75)/2=618plf618plf >567plf,OK8dnailsat2”o.c.acceptableforperforatedwall

PANELGRADE FASTENER

TYPE&

SIZE

MINIMUM

PANEL

THIICKNESS

MINIMUM

FASTENER

PENETRATION

INFRAMING

NAIL SPACING

ATALLPANEL

EDGES

PANEL EDGE

FASTENERSPACING

Wood Structural

Panels–

Sheathing

8d(2½“x

0.131”)

15/32” 13/8” 2IN. 1280(Seismic)

1790(Wind)

SDPWSTable4.3A

Page 76: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

PerforatedShearwall Overturning

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =567plfHolddownsrequiredatendsofperforatedwall

T=νh/CoT=567plf*10’/0.75=7,560lb

Holddowncapacityfromsegmentedwalloption=7,045lb,Inadequate– needtoselecthighercapacityholddown

Page 77: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

PerforatedShearwall Uplift

34’

6’ 6’ 6’ 6’ 6’2’ 2’

10’

νshearwall =567plf/0.75=756plf,usesamemagnitudeforuniformupliftatfullheightsegmentsOneoptionistouseanchorboltswithlargewasherstoresistupliftin

bearingIfnetwasherarea=8in2,canresist(565psi)(8in2)=4,520lb inuplift

• Max.anchorboltspacing=4,520lb/756plf =5’-11”o.c.• Willalsoneedtocheckshearloadsonanchorboltsforcontrolling

case

Page 78: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ForceTransferAroundOpening(FTAO)

Page 79: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

FTAOShearwalls Methodologies• Shearwall designmethodologywhichaccountsforsheathed

portionsofwallaboveandbelowopenings(perforatedneglects)

• Openingsaccountedforbyreinforcingedgesusingstrappingorframing

• SDPWS4.3.5.2providesspecificrequirements

• H/Lratiodefinedbywallpier

• Min.wallpierwidth=2’-0”

• Reducednumberofholddowns(onlyatendsoftotalwall)

• Thereare3mainmethodsofFTAOanalysis;SDPWSdoesnotrequireoneparticularmethodbeused,onlythatdesignis“basedonarationalanalysis”

• DragStrut,CantileverBeam,&Diekmann DesignOptions

Page 80: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

WhyUseForceTransferAroundOpenings?

Fullheightwallpiersdonotmeetmax3.5:1Ratio

10feettall

2feetwide

10/2=5>3.5

NotAShearwall!

Page 81: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

WhyUseForceTransferAroundOpenings?

ShorterConstrainedpiersdomeet3.5:1max

aspectratio

5feettall

2feetwide

5/2=2.5< 3.5

CanbeaShearWall!

Page 82: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ReferencesforFTAODesign

APAAuthoredSEAOCPaperhttps://www.apawood.org/Data/Sites/1/documents/technicalresearch/seaoc-2015-ftao.pdf

SEAOCStructural/SeismicDesignManual,Volume2Providesnarrativeandworked outexample

DesignofWoodStructuresTextbookbyBreyeretal.

Page 83: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Double-SidedShearwalls

High-strengthwoodshearwallscanbedouble-sidedwithWSPsheathingoneachside:

SDPWS4.3.3.3SummingShearCapacities:Forshearwallssheathedwiththesameconstructionandmaterialsonoppositesidesofthesamewall,thecombinednominalunitshearcapacity shallbepermittedtobetakenastwicethenominalunitshearcapacityforanequivalentshearwallsheathedononeside(4.3.5.3hasmaxcapacitiesfordouble-sidedperforatedwalls)

Page 84: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Double-SheathedShearwalls

Thereisalsoanoptiontohaveasinglesided,doublesheathedshearwall.

TestingandreportbyAPAconcludethatitispermissibletousethecapacityofthewallthesameasiftherewasonelayerofWSPoneachsideofthewallprovidedthatanumberofcriteriaaremetincluding:

• Framingmembersatpaneljointsare3xor2-2x

• Minimumnailspacingis4”

• Others

Page 85: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

Questions?

ThisconcludesTheAmericanInstituteofArchitectsContinuingEducationSystemsCourse RickyMcLain,MS,PE,SE

TechnicalDirector- WoodWorks

[email protected]

(802)498-3310

Visitwww.woodworks.org formoreeducationalmaterials,casestudies,designexamples,aprojectgallery,andmore

Page 86: Wood-Frame Shear Wall and Diaphragm Design · MAXIMUM SHEAR WALL DIMENSION RATIOS See SDPWS Table 4.3.4 for footnotes Wood structural panels, blocked For other than seismic: 3½:11

ThispresentationisprotectedbyUS

andInternationalCopyrightlaws.

Reproduction,distribution,displayanduseofthepresentationwithoutwrittenpermission

ofthespeakerisprohibited.

©TheWoodProductsCouncil2017

CopyrightMaterials