when you expect capillary electrophoresis...providing customers a high level of...
TRANSCRIPT
w w w . a n a l i s . b e / c e o f i x
when you expect more from capillary electrophoresis
ANALIS
Scientific Instruments for Laboratories
Providing Customers a high Level of Competence
Distributor and Manufacturer of Scientific Apparatus for Laboratories
Analis is a leading laboratory equipment trade company in the BENELUX market.
Our mission is to be present in every laboratory as the leading laboratory instrument supplier. We aim to be a true partner, who gives application support and a professional technical after sales service.
Our purpose and goal is to provide the laboratory the highest level of competence and service.
www.anal is.be 3
ANALIS
Scientific Instruments for Laboratories
A Well-Known & Well-Established Belgian CompanyA Well-Established Belgian CompanyAnalis headquarter is located in the south of Belgium (Suarlée, near Namur) and there is a branchoffice in the north (Ghent).Analis headquarter (5 200 m2 a warehouse 1 100 m2) includes a research laboratory (160 m2) and a production unit (180 m2).
Analis employs more than 140 people with over 90 highly skilled people at university level (PhD, Engineer, Biologists,…).
Key figures:• A current ratio of 2,22 (ability to meet short term commitments)• A solvent ratio of 49,4% (financial independence)• A turnover of 33 Million €
Certified ISO 9001 – 2008This covers all our activities including conception, production, distribution and also technical assistance.
www.anal is.be 5
analis
“R&D Diag” laboratory
25 years experience
Expertise and Leadership at your service
www.anal is.be 7
our “R&D Diag” laboratory
25 years experience
A Total Solution Oriented Team
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 37 [email protected] I www.analis.be/ceofix
R&D LaboratoryApplication oriented
• In Vitro Diagnostics
• Pharmaceutics
• Food
• Chemicals
ProductionQuality
• CEofix™ kits
• OEM kits
• Customer buffers
Training – SupportCustomer oriented
• CEofix™ kits
• Capillary Electrophoresis
• Customer samples
A Total Solution Oriented Team
www.anal is.be 9
Our “R&D Diag” Laboratory
25 years experience
Recognized by Major Companies
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 37 [email protected] I www.analis.be/ceofix
Export > 80%Europe, United States, Canada, Australia, Japan, China, Taiwan, Korea…
Customers:• Major clinical labs in Belgium, France,
Italy, Switzerland, Netherlands,…
• Pharmaceutical companies such as: Johnson and Johnson, Novartis, Baxter, GSK, Safoni Pasteur,...
• Collaboration: Beckman Coulter
Recognized by Major Companies
www.anal is.be 11
Our “R&D Diag” Laboratory
25 years experience
A Total Solution Oriented Team
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 37 [email protected] I www.analis.be/ceofix
A Network of Partners all over the world
• Professional associations: IFCC, CASSS, UDIAS, UNAMEC, BIOWIN, Wal-DX FLANDErS BIO , …
• A wide knowledge network all over the world of more than 100 suppliers of scientific instruments
• Collaboration with research communities and laboratories all over the world.
• ANALIS r&D has a strong relation with Beckman Coulter
• Supported by AWEX (Wallonia Foreign Trade and Investment Agency)
A Total Solution Oriented Team
www.anal is.be 13
Our “R&D Diag” Laboratory
25 years experience
Partner of ScientificCommunities
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 37 [email protected] I www.analis.be/ceofix
Applications notes• ANALYSIS OF HAEMOGLOBINES using CEofix™ HbA1 c and HbA2 for
Beckman Coulter P/ACE™ MDQ. François de l’Escaille, Jean-Bernard Falmagne ANALIS.
• Glycated Hemoglobin (HbA1c) measurement and Hemoglobin variant characterization by CE with Beckman Coulter P/ACE 5000 and MDQ Instruments. François de l’Escaille, Jean-Bernard Falmagne ANALIS.
• CEofix™ - Analysis of neutral and charged molecules using CEofix MEKC KIT. François de l’Escaille, Jean-Bernard Falmagne ANALIS.
• Determination of Oxidized and ReducedGlutathione in Whole Blood Using CEofix™ GSH/GSSG and Beckman Coulter P/ACE™ MDQ. François de l’Escaille, Jean-Bernard Falmagne ANALIS.
• CE Analysis of Propranolol in Human Serum Using Dynamic Capillary Coating. Lilian Clohs and Angelina K. Winstanley,Cardiome Pharma Corp., Vancouver, British Columbia, Canada.
• Advantages of Capillary Electrophoresis In the determination of Carbohydrate-deficient Transferrin (CDT). François de l’Escaille, Michel Brohet, Francis Pourignaux ANALIS.
• ANALYSIS OF CARBOHYDRATE DEFICIENT TRANSFERRIN using CEofix™ CDT for Beckman Coulter P/ACE™ MDQ.
• CEofix™ - Coating dynamique pour des analyses CE-DAD et CE-MS rapides et reproductibles de drogues basiques. Vanhoenacker G.1, de l’Escaille F.2, Sandra P.1 1. Gent University 2. Analis Namur.
• Simultaneous Analysis of Artificial Sweeteners and Preservatives in Soft Drinks: a fast and easy method by using Micellar Electrokinetic Chromatography.
• Purification of Transferrin Isoforms from Serum prior to analysis with Capillary. François de l’Escaille, Jean-Bernard Falmagne ANALIS.
• Scientific Poster CEPharm 2010 Strategy to Analyze Aminoglycosides type molecules with Capillary Electrophoresis. François de l’Escaille, Jean-Bernard Falmagne, Philippe Louis, Fabrice Benoit - ANALIS.
• Scientific Poster CEPharm 2010 Pattern Oriented Approach of Analyzing Herbal Medicines with Capillary Electrophoresis. François de l’Escaille, Jean-Bernard Falmagne, Philippe Louis, Fabrice Benoit - ANALIS.
• Scientific Poster Drug Analysis 2010 Preliminary Evaluation of Carbohydrate Determination with Direct UV Detection. François de l’Escaille, Jean-Bernard Falmagne, Fabrice Benoit - ANALIS.
• Scientific Poster Drug Analysis 2010 Optimization of Anion Analysis on Capillary Electrophoresis. François de l’Escaille, Jean-Bernard Falmagne, Fabrice Benoit - ANALIS.
• Scientific Poster MSB 2010 Preliminary Evaluation of Carbohydrate Determination with Direct UV Detection. François de l’Escaille, Jean-Bernard Falmagne, Fabrice Benoit - ANALIS.
• Scientific Poster MSB 2010 Optimization of Anion Analysis on Capillary Electrophoresis. François de l’Escaille, Jean-Bernard Falmagne, Fabrice Benoit - ANALIS.
Partner of ScientificCommunities
www.analis.be/ceofix see applications www.anal is.be 15
Our “R&D Diag” Laboratory
25 years experience
Our Researchers recognized in ScientificCommunities
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 37 [email protected] I www.analis.be/ceofix
Publication as co-author• Capillary electrophoresis system for hemoglobin A1c determination evaluated.
Doelman C. et al. (1997). Clin Chem 43:4, 644-648.
• Quantitative determination of haptoglobin (HAP) in human and bovine sera by capillary electrophoresis (CZE). Pirlot et al. (1999). Vet res 30, 483-493.
• Determination of Carbohydrate-deficient Transferrin Using Capillary Zone Electrophoresis. Wuyts B. et al. (2001). Clin Chem 47:2, 247-255.
• Carbohydrate-deficient Transferrin Isoforms Measured by Capillary Zone Electrophoresis for Detection of Alcohol Abuse. Legros F. et al. (2002). Clin Chem 48:12, 2177-2186.
• Diagnosis of Congenital Disorders of Glycosylation by Capillary Zone Electrophoresis of Serum Transferrin. Carchon H. et al. (2004). Clin Chem 50:1, 101-111
• La transferrin hyposialylée et le % CDT. Mesure par électrophorèse capillaire avec le coffret CEofix CDT (ANALIS) chez des sujets consommateurs modérés. Loiseaux M.-N. et al. (2004). Immuno-analyse & Biologie spécialisée 19, 148-156.
• Dynamic coating for fast and reproducible determination of basic drugs by capillary electrophoresis with diode-array detection and mass spectrometry. Vanhoenacker G. et al. (2004). J Chromatogr B 799, 323-330.
• Analysis of Benzodiazepines in Dynamically Coated Capillaries by CE-DAD, CE-MS and CE-MS2. Vanhoenacker G. et al. (2004). J. Pharm. Biomed. Anal. 34, 595-606.
• Determination of carbohydrate-deficient transferrin in human serum with capillary zone electrophoresis: Sample preparation strategies for the removal of interferences caused by increased levels of immunoglobulins. Lanz C. et al. (2008). J Chromagr A 1206, 33-40.
• Ion Analysis using Capillary Electrophoresis. de l’Escaille F. and Falmagne J.-B. (2008). In « Capillary Electrophoresis Methods for Pharmaceutical Analysis » (J. Ahuja, M. Jimidar Ed.). pp. 391-433 Elsevier
• Contribution of CE to the Analysis of Protein or Peptide Biomarkers. Mesbach K., Verlpillot r., de l’Escaille F., Falmagne J.-B., and Taverna M. (2013). In « Capillary Electrophoresis and Protocols » (Volpi N., Maccari F. Eds.), vol. 984 pp. 167-190 Springer Science+Business Media
Our Researchers recognized in ScientificCommunities
www.anal is.be 17
“R&D Diag” laboratory
Training
application support congress
Attendance at Major International Exhibitions:
• AACC Annual Meeting (US) Clinical Laboratory
• Arab Health Medlab Dubai (U.A.E.) Clinical Laboratory
• CE in the Biotechnology & Pharmaceutical Industries CASSS (US) Separation sciences
• CMEF China Medical Equipment Fair Shenzhen (China) Clinical laboratory
• IFCC-Worldlab Euromedlab Europe Clinical laboratory
• MEDICA Düsseldorf (Germany) Clinical laboratory
• MSB MicroScale Bioseparations and Analyses (EU, US, China) Separation Sciences
www.aacc.org www.arabhealthonline.com www.casss.org www.medica.de www.casss.org
A Total Solution Oriented Team
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 [email protected] I www.analis.be/ceofix
A Total Solution Oriented Team PROjECTS AND COLABORATION
Analis r&D is looking to collaborate with specialized distributors in several countries to sell and promote its kits and applications.
Through collaboration with specialized research centers and research organizations, Analis r&D intends to develop new applications and kits using primary capillary electrophoresis. Several projects are currently under way.
SAMPLES ANALYSIS ON DEMAND (*)• CLINICAL LABOrATOrIES:
To help our customers with the Analis r&D kits we may analyze your samples which causes problems in your laboratory.
• BIOPHArMACEUTICAL and BIOTECH LABOrATOrIES: While we have experience analyzing protein and peptides using our CEofix™ kits and using Beckman Coulter kits (Molecular Weight, cIEF, or Glycans), we may share our expertise for feasibility studies and assistance.
• PHArMACEUTICAL, FOOD, ENVIrONMENTAL and CHEMICAL LABOrATOrIES: Also for small molecules such as anions and cations but also organic acids and many other analytes, including chiral molecules, we may provide recommendation and help.
(*) Ask our team to submit your specific problem and samples. We will also provide you with a detailed description of our proposal.
TRAINING FOR BECKMAN COULTER P/ACE™ MDQ OR PA 800 USERS (**)
• We provide 3 day training for new and experienced users of 32K software for P/ACE MDQ. This training includes hands-on and troubleshooting.
• Specific training in customers laboratories are also organized in order to refresh the existing knowledge and troubleshoot existing problems.
(**) Training program and calendar is available on request
www.anal is.be 19
“R&D Diag” laboratory
our solutions our products
Applications notes available
Analyses of Haemoglobines using CEofix™ HbA1c and HbA2 for Beckman Coulter P/ACE™ MDQ.François de l’Escaille, Jean-Bernard Falmagne ANALIS.
Children’s Health & Prevention
www.analis.be/ceofix see applications
CE - IVD
OUR SOLUTION: our diagnostic kits CEofix™ HbA2 allows screening for hemoglobin- opathies using capillary electrophoresis at basic pH, while CEofix™ HbA1c allows confirmation using an acidic buffer.
IMPORTANCE: sickle cell anemia, hemoglobin SC disease and some thalassemias are common major life-threatening diseases which are important to detect as soon as possible.
Children’s Health and Prevention Screening for Hemoglobines
Hemoglobinopathies and ThalassemiaHemoglobinopathy: a genetic defect that results in abnormal structure of the globin chains of the hemoglobin molecule.
Thalassemia: a genetic defect that results in production of an abnormally low quantity of a given hemoglobin chain or chains.
Children’s Health & Prevention
www.anal is.be 21
“R&D Diag” laboratory
our solutions our products
Health & Prevention
CE - IVD
OUR SOLUTION: CEofix™ HbA1c will allow an easy screening for HbA1c as well as follow-up of affected individuals
IMPORTANCE: Diabetes (type 1 and type 2) is a worldwide epidemic that affects more than 220 million people worldwide and is expected to reach 366 million in 2030. Diabetes is likely to be the fifth leading cause of death. Early diagnosis is therefore mandatory
Screening and Prevention of Diabetes
Diabetes is a chronic disease that occurs when the body does not produce enough insulin. While insulin regulates the blood sugar, too high amount of sugar will lead to serious damage. Diagnosis can be done by measuring the HbA1c level in the red blood cell for both types of diabetes type 1 and type 2 (new guidelines).
Health & Prevention
www.anal is.be 23
our “R&D Diag” laboratory
25 years experience
Children’s Health & PreventionCEofix™ SPE kit
“Serum Protein Electrophoresis”
Brochure: www.analis.be/ceofix
CE - IVD
Health Prevention screening of abnormal proteins
SPE “Serum Protein Electrophoresis”Electrophoresis is used to identify the presence of abnormal proteins, to identify the absence of normal proteins, and to determine when different groups of proteins are present in unusually high or low amounts. It is useful to detect acute and chronic inflammation, liver and renal disorders…
Children’s Health & Prevention
OUR SOLUTION: our CEofix™ SPE kit allows fast en easy testing for serum proteins.
IMPORTANCE: Alterations to the usual appearance of these patterns can help in the diagnosis of disease. The presence of an abnormality on a protein electrophoretic pattern provides an indication for inflammation, liver disorder, renal disorder etc…. It may be a starting point for further follow-up testing.
www.anal is.be 25
“R&D Diag” laboratory
our solutions our products
Applications notes available
Analysis of Carbohydrate Deficient Transferrin using CEofix™ CDT for Beckman Coulter P/ACE™ MDQ.
A Total Solution Oriented Team
www.analis.be/ceofix see applications
CE - IVD • FDA device listed
Health Prevention - Screening for Alcohol Abuse or Dependence
CDT “Biomarker for Excessive Alcohol Consumption”Alcohol Abuse is a psychiatric diagnosis describing the use of alcoholic beverages despite negative consequences.
Alcohol Dependence is a psychiatric dependence on alcohol.
CDT or carbohydrate deficient transferrin will increase when consuming regularly alcohol.
A Total Solution Oriented Team
OUR SOLUTION: our CEofix™ CDT kit allows high resolution separation of transferrin isoforms even in presence of variants.
IMPORTANCE: regularly consuming alcohol is correlated with an increased risk of developing alcoholism, alcoholic liver disease and cancer. Screening will help health care professionals with diagnosis, withdrawal and follow-up of alcohol abusers. It is also helpful for liver transplantation.
www.anal is.be 27
“R&D Diag” laboratory
our solutions our products
Security & Forensics Analysis
www.analis.be/ceofix see applications
Applications notes available
Analysis of Carbohydrate Deficient Transferrin using CEofix™ CDT for Beckman Coulter P/ACE™ MDQ.
CE - IVD • FDA device listed
Security & Forensic Analysis Screening for Alcohol Consumption
CDT “Biomarker for Excessive Alcohol Consumption” Alcohol Abuse is a psychiatric diagnosis describing the use of alcoholic beverages despite negative consequences.
Alcohol Dependence is a psychiatric dependence on alcohol.
CDT or carbohydrate deficient transferrin will increase when consuming regularly alcohol.
Security & Forensics Analysis
OUR SOLUTION: our CEofix™ CDT kit allows high resolution separation of transferrin soforms even in presence of variants.
IMPORTANCE: social problems are associated with alcohol abuse, this includes traffic accidents, work-place related problems, family and domestic problems, and interpersonal violence.
www.anal is.be 29
“R&D Diag” laboratory
our solutions electrophoresis Diagnostic Kits
Applications notes availableTotal Solution Oriented
www.analis.be/ceofix see applications
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 [email protected] I www.analis.be/ceofix
CE - IVD
Protur™ HiSi - Protur™ Plus - Protur™ Bence jones Kits Urine Proteins Analysis.Urine protein electrophoresis pattern is a highly sensitive diagnostic system that can detect pre-renal, renal and post-renal physiologic and pathologic events. Protur™ HiSi is used for screening as well as Protur™ Plus and Protur™ B.J., but the last two also enables confirmation and typing of monoclonal components.
Isopal™ Plus Kit Kit for Alkaline Phosphatase Isoenzymes.Alkaline phosphatase is part of a group of enzymes that catalyze the hydrolysis and transfer of a phosphate group from a donor to an acceptor at alkaline pH. Alkaline phosphatase is used to aid in diagnosis of hepatobiliary disease and bone disease associated with increased osteoblastic activity.
IsoAmyl Amylase Isoenzymes Kit Pancreas DiseaseAssays of amylase activity in serum and urine are used in the diagnosis of disease of pancreas and in investigations of pancreatic function.
Total Solution Oriented
www.anal is.be 31
Our “R&D Diag” Laboratory
25 years experience
Capillary Electrophoresis Technology
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 37 [email protected] I www.analis.be/ceofix
Technology
Electrophoresis is a separation technique that is based on the differential migration of charged compounds in a semi-conductive medium under the influence of an electrical field. When using capillary electrophoresis (CE) or capillary zone electrophoresis (CZE,) separation is done inside a narrow bore capillary (with an internal diameter between 20 and 100 µ).
The capillaries are made of fused silica and filled with an electrolyte or gel. For high separation efficiency the current may be as high as 30 kV. A cooling system will remove excessive Joule heating. Detection is performed online on the capillary with an UV, LIF (Laser Induced Fluorescence), or CCD (Contactless Conductivity Detection) detector. CE is also connected to MS.
The mean characteristics of Capillary Electrophoresis are: simplicity, selectivity and low cost. Furthermore, Capillary Electrophoresis offers higher efficiency than HPLC and thus greater resolution power for separating various components. It is recognized as an ideal method to separate proteins but also small molecules.
Capillary Electrophoresis Technology
www.anal is.be 33
Our “R&D Diag” Laboratory
25 years experience
Other Solution
Other Solutions
FOR CLINICAL RESEARCH (RUO)Kits and applications are available that allow analysis of oxidized and reduced Glutathione in whole blood, but also proteins in Cerebrospinal Fluid or anions and organic acids in urine and serum. A new application allows determination of carbohydrates in serum or urine.
FOR ANALYTICAL APPLICATIONSSeveral kits and applications are available for:
• Biopharmaceutical applications for proteins and peptides
• Traditional Pharmaceutical applications, including purity, counter-ion and chiral analysis
• Food Analysis, including anions, cations, organic acids, carbohydrates, edulcorants, conservatives, etc…
• Environmental analysis
• Forensic analysis including sized drugs and explosives.
Other Solution
www.anal is.be 35
Our “R&D Diag” Laboratory
25 years experience
A Team you can build on
Zoning Industriel de Rhisnes11 Rue de Neverlée I 5020 Suarlée (Belgium) Tel +32 (0)81 25 50 50 I Fax +32 (0)81 23 12 37 [email protected] I www.analis.be/ceofix
Conclusion
CEofix™ buffers a product development & solutions
Analis r&D Diag a expertise & 25 years experience
Analis r&D Diag a support and training
A Team you can build on
www.anal is.be 37
Your Contact:
ANALIS sa/nvBelgium
Tel + 32 81 25 50 50Fax + 32 81 23 12 37www.analis.be/ceofixe-mail: [email protected]
François de l’EscailleBusiness Development & r&D Managere-mail: [email protected]
Our “R&D Diag” Laboratory
25 years experience
Our products
Our products Our products
CLINICAL DIAGNOSTICSSerum Proteins (Capillary Electrophoresis)
• CEofix™ CDT for alcohol abuse• CEofix™ SPE for serum proteins• CEofix™ CDT for Congenital Disorders of Glycosylation (CDG)
Hemoglobin Analysis (Capillary Electrophoresis)• CEofix™ HbA1c
for glycated hemoglobin and Hb variants• CEofix™ HbA2
for thalassemia and Hb variant
Isoenzyme Electrophoresis (Paragon Electrophoresis)• Isopal™ Plus for alkaline phosphatase• Isoamyl for alpha-amylase isoenzymes
Urine Protein Analysis (Paragon Electrophoresis)• Protur™ HiSi for proteins in unconcentrated urine• Protur™ Plus for immunofixation of proteins in urine• Protur™ B.J. for Bence Jones proteins
Clinical Research (Capillary Electrophoresis)• CEofix™ GSH for oxidized and reduced glutathione.• Anions/Cations for anions, cations and
organic acids in biological fluids• CEofix™ NTMP for proteins in cerebrospinal fluid• CEofix™ CARBO for analysis of mono- and disaccharides
ANALYTICAL FOR R&D AND QCPharmaceutical Applications
• Anions/Cations : counterion analysis, purity profiling• CEofix™ MS for CE/MS Coupling• CEofix™ pH/MEKC for drug analysis• CEofix™ MEKC for edulcorants• CEofix™ Carbo for analysis of carbohydrates
Ion Analysis• Anions/Cations :
Analysis of anions, cations, organic acids and aliphatic amines
Applications for Food Analysis• Anions/Cations :
Analysis of anions, cations, organic acids and aliphatic amines• CEofix™ MEKC for edulcorants and conservatives• Follow up of cell culture and fermentation (by combining different kits)
Applications for Protein Analysis• CEofix™ NTMP : for protein analysis• CEofix™ pH : for peptide analysis
Forensic Applications• CEofix™ CDT for alcohol abuse• Urine toxicology CE Kit : for screening of basic drugs with Beckman
Coulter P/ACE MDQ DAD (also applicable for serum)• CEofix™ MS for CE/MS Coupling• CEofix™ pH and MEKC kit for analysis of seized drugs• Anions for counter-ion analysis of seized drugs• CEofix™ CARBO for analysis of sugar in explosives or in drugs
www.anal is.be 39
www.analis.be/ceofix
when you expect more from capillary electrophoresis
r&
D_b
roc
hu
reC
ap
illa
ryEl
ec
tro
2013
• 0
3-20
13
ANALIS s.a./n.v. BelgiumTel + 32 81 25 50 50 Fax + 32 81 23 12 [email protected]