what does c2 do
TRANSCRIPT
-
8/6/2019 What does C2 do
1/16
What does CAESAR II do?
9/15/2010
-
8/6/2019 What does C2 do
2/16
Session overview
Taking the task from piping design to piping engineering.
What questions does CAESAR II answer?
.
Should conclude within the hour.
Please use the Webinar dialog box to post your questions.
9/15/2010 Intergraph CADWorx & Analysis Solutions 2
-
8/6/2019 What does C2 do
3/16
Piping designer responsibilities
Designer locates equipment and then routes pipe between these positions using anestablished pipe specification
The piping system is a unique pressure containment.
Givens:
Pipe size is based on pressure drop, flow rate
Pipe specification (e.g. wall thickness) is based on design pressure & temperature
Material based on service requirements
Designer has established rules for basic layout
Hydraulic issues
Spans between supports (deadweight sag) System stability
Access / clearance
9/15/2010 3Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
4/16
So whats left for the piping engineer?
Many systems require analysis to evaluate strain
Sources of thermal growth
Pipe
Equipment connections (vessels and equipment)
Other sources of strain Support settlement
Support movement in marine piping
Strain Load Stress
Evaluate pipe load as stress due to this strain
Evaluate load on equipment directly
Except for simple layouts, the system response due to this strain is difficult to estimate
Analysis yields a better estimate of pipe deflection, loads on pipe supports and equipmentconnections, and stress in the piping; and not only for strain.
100 feet @ 170F
9/15/2010 4Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
5/16
-
8/6/2019 What does C2 do
6/16
Four typical interests in pipe stress analysis
Selecting and sizing supports
Checking pipe deflection under load
Evaluating pipe stress
And not only for those strain-based loads
Deadweight
Pressure
Wind & wave
Earthquake
y rau c rans en s
Vibration
9/15/2010 6Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
7/16
Creating a CAESAR II Model
(the analog) Start with a stress isometric or similar concept
Mark up the drawing for analysis
Create the i in in ut model a di ital re resentation of that analo
90110
80
100
10
120
20
9/15/2010 7Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
8/16
Analog to digital
Analog Digital representation
9/15/2010 Intergraph CADWorx & Analysis Solutions 8
-
8/6/2019 What does C2 do
9/16
CAESAR II Results
1. Hanger selection, restraint load
2. Pipe sag, horizontal deflection
.
4. Stress check
A few examples will illustrate
9/15/2010 9Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
10/16
-
8/6/2019 What does C2 do
11/16
2. Check Deflection
ow muc oes s e ow
move when the systemheats up?
9/15/2010 11Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
12/16
3. Evaluate Equipment Load
Is this compressoroverloaded?
Compressor
ThermalGrowth
Anchor
9/15/2010 12Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
13/16
4. Evaluate Pipe Stress
This stub in connection isoverstressed and will failby fatigue over time.
9/15/2010 13Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
14/16
Analyze and review TURBO
9/15/2010 14Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
15/16
Document Results
9/15/2010 15Intergraph CADWorx & Analysis Solutions
-
8/6/2019 What does C2 do
16/16
Conclusion
9/15/2010 Intergraph CADWorx & Analysis Solutions 16