welding positions according to din en iso 6947
TRANSCRIPT
PA
PB
PD
PE
PH
PJ
PG
PF
PC
Messer Group GmbHGahlingspfad 31, 47803 Krefeld, Germany
Phone +49 2151 7811-162, Fax +49 2151 7811- 598www.messergroup.com
Messer offers shielding gases for all welding applications:
Ferroline Shielding gases for unalloyed and low-alloyed steels
Inoxline Shielding gases for high-alloyed steels
Aluline Shielding gases for aluminum and non-ferrous metals
Lasline Gases for laser welding and cutting
Formiergas Root protection for high and low-alloyed steels
As of 10/2014 | © Messer Group GmbH
Different positioning of the wire electrode is recommended depending on the welding task.
Key:
PA flat position
PB horizontal vertical position
PC horizontal position
PD horizontal overhead position
PE overhead position
PF vertical up position
PG vertical down position
PH pipe position for welding upwards (formerly PF)
PJ pipe position for welding downwards (formerly PG)
Welding positions according to DIN EN ISO 6947
pipe rotation
pipe rotation
pipe rotation
pipe fixed
pipe fixed
pipe fixed
J-L045pipe fixed
inclined positionwelding downwards
H-L045 pipe fixed
inclined position welding upwards
pipe fixed
pipe fixed
pipe fixed
pipe fixed
buttwelds
flletwelds
6G downhill
6G uphill
5F downhill
5F uphill
3F uphill
5G uphill
3G uphill
4G 4F
4F
2G
2G
2F
1G1G
2F
2FR
1FR
5G downhill
3G downhill
3F downhill
Welding positions according to AWS 3.0 ASME Section IX
1F