SECTION 08 71 53 DOOR HARDWARE Display hidden notes to specifier. (Don't know how? Click Here ) Copyright 2015 ARCAT, Inc. - All rights reserved 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Hinges and Pivots. 1.1.2 Mortise Locksets and Deadbolts. 1.1.3 Cylindrical Locksets and Deadbolts. 1.1.4 Dead Bolts. 1.1.5 Cylinders. 1.1.6 Keying. 1.1.7 Exit Devices. 1.1.8 Surface Door Closers. 1.1.9 Concealed Door Closers. 1.1.10 Low Energy Operators. 1.1.11 Fire/Life Safety Devices. 1.1.12 Miscellaneous Trim. 1.2 RELATED SECTIONS 1.2.1 Section 05 10 00 - Structural Metal Framing. 1.2.2 Section 06 10 00 - Rough Carpentry. 1.2.3 Section 07 84 13 - Penetration Firestopping Mortars. 1.2.4 Section 08 11 00 - Metal Doors and Frames. 08 71 00-1

Upload: others

Post on 23-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

SECTION 08 71 53DOOR HARDWARE

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2015 ARCAT, Inc. - All rights reserved

1 GENERAL

1.1 SECTION INCLUDES

1.1.1 Hinges and Pivots.

1.1.2 Mortise Locksets and Deadbolts.

1.1.3 Cylindrical Locksets and Deadbolts.

1.1.4 Dead Bolts.

1.1.5 Cylinders.

1.1.6 Keying.

1.1.7 Exit Devices.

1.1.8 Surface Door Closers.

1.1.9 Concealed Door Closers.

1.1.10 Low Energy Operators.

1.1.11 Fire/Life Safety Devices.

1.1.12 Miscellaneous Trim.

1.2 RELATED SECTIONS

1.2.1 Section 05 10 00 - Structural Metal Framing.

1.2.2 Section 06 10 00 - Rough Carpentry.

1.2.3 Section 07 84 13 - Penetration Firestopping Mortars.

1.2.4 Section 08 11 00 - Metal Doors and Frames.

1.2.5 Section 08 10 00 - Doors and Frames.

1.2.6 Section 08 41 23 - Steel-Framed Entrances and Storefronts.

1.2.7 Section 08 71 70 - Weatherstripping and Seals*.

08 71 00-1

Page 2: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

1.2.8 Section 28 16 00 - Intrusion Detection.

1.2.9 Section 28 13 53 - Security Access Detection.

1.2.10 Section 26 05 00 - Common Work Results for Electrical.

1.3 REFERENCES

1.3.1 ANSI A117.1 - American National Standard for Accessible and Useable Buildings and Facilities.

1.3.2 ANSI/BHMA A156.1, "Butts and Hinges" (copyrighted by BHMA, ANSI approved).

1.3.3 ANSI/BHMA A156.2 - American National Standard for Bored and Preassembled Locks & Latches.

1.3.4 ANSI/BHMA A156.3 - American National Standard for Exit Devices.

1.3.5 ANSI/BHMA A156.4 - American National Standard for Door Controls - Closers.

1.3.6 ANSI/BHMA A156.5 - American National Standard for Auxiliary Locks and Associated Products.

1.3.7 ANSI/BHMA A156.6, "Architectural Door Trim" (copyrighted by BHMA, ANSI approved).

1.3.8 ANSI/BHMA A156.7, "Template Hinge Dimensions" (copyrighted by BHMA, ANSI approved).

1.3.9 ANSI/BHMA A156.8, "Door Controls - Overhead Holders" (copyrighted by BHMA, ANSI approved).

1.3.10 ANSI/BHMA A156.13 - American National Standard for Mortise Locks and Latches Series 1000.

1.3.11 ANSI/BHMA A156.15 - Life Safety Closer/Holder/Release Devices.

1.3.12 ANSI/BHMA A156.16 - Auxiliary Hardware.

1.3.13 ANSI/BHMA A156.18 - Materials and Finishes.

1.3.14 ANSI A156.19 - American National Standard for Power Assist and Low Energy Power Operated Doors.

1.3.15 ANSI A156.23 - American National Standard for Electromagnetic Locks

1.3.16 ANSI A156.24 - American National Standard for Delayed Egress Locks

1.3.17 ANSI A156.25 - American National Standard for Electrified Locking Devices

1.3.18 ANSI A156.28 - American National Standard for Keying Systems

1.3.19 ANSI A156.29 - American National Standard for Exit Locks and Alarms, Exit Locks with Exit Alarms and Alarms for Exit Devices

1.3.20 ANSI A156.31 - American National Standard for Electric Strikes and Frame Mounted Actuators

1.3.21 NFPA 80 - Standard for Fire Doors, Fire Windows.

1.3.22 NFPA 252 - Standard Methods of Fire Tests of Door Assemblies.

08 71 00-2

Page 3: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

1.3.23 Underwriters Laboratories (UL). - Fire Resistance Directory.

1.3.24 ANSI/UL 10C - Standard for Safety for Positive Pressure Fire Tests of Door Assemblies.

1.4 PERFORMANCE REQUIREMENTS

1.4.1 Fire Rated Openings: Provide door hardware listed by UL or Intertek Testing Services (Warnock Hersey Listed), or other testing laboratory approved by applicable authorities.1.4.1.1 Comply with NFPA 80 for fire ratings indicated, based on testing according to

NFPA 252.1.4.1.2 Comply with UL10C, Positive Pressure Fire Tests of Door Assemblies.

1.4.2 Accessibility Requirements: Comply with requirements of Local building code, and Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities.

1.5 SUBMITTALS

1.5.1 Submit under provisions of Section 01 30 00.

1.5.2 Product Data: Manufacturer's catalog cuts on each product to be used.

1.5.3 Shop Drawings: Indicate locations and mounting heights of each type of hardware, schedules, electrical characteristics and connection requirements.

1.5.4 Schedule:1.5.4.1 Submit schedule indicating each type of hardware for each door.1.5.4.2 List manufacturer's name with each manufacturer's hardware number together

with finishes in US standards.1.5.4.3 Show door number/location, handing, door and frame material, manufacture and

catalog numbers, all finishes and keying information. Explain fully all abbreviations.

1.5.5 Shop Drawings:1.5.5.1 Indicate locations and mounting heights of each type of hardware.1.5.5.2 Supply templates to door and frame manufacturer(s) to enable proper and

accurate sizing and locations of cut-outs for hardware.1.5.5.3 Detail any conditions requiring custom extended lip strikes, or any other special

or custom conditions.1.5.5.4 Wiring diagrams including point to point and riser diagrams, function statements

and system descriptions for all electrical hardware

1.5.6 Verification Samples: For each finish product specified.1.5.6.1 If required by the Architect, submit one sample of each type of typical hardware

required illustrating style, color, and finish.1.5.6.2 Approved samples may be incorporated into Work.

1.5.7 Closeout Submittals:1.5.7.1 Project Record Documents: Schedule showing actual locations of installed

cylinders and their master key code.1.5.7.2 Parts lists and maintenance instructions including data on operating hardware,

lubrication requirements, and inspection procedures related to preventative maintenance.

1.5.7.3 Keys: Deliver with identifying tags to Owner by security shipment direct from hardware supplier.

1.6 QUALITY ASSURANCE

08 71 00-3

Page 4: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

1.6.1 Manufacturer Qualifications: A manufacturer with a minimum of ten years experience manufacturing door hardware.

1.6.2 Supplier Qualifications: A supplier with a minimum of two years demonstrated experience in the sale and distribution of builders' hardware for commercial projects and who has successfully completed at least three projects of similar complexity to the project specified.

1.6.3 Hardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services required for the project.

1.7 DELIVERY, STORAGE, AND HANDLING

1.7.1 Package hardware items individually with necessary fasteners and installation templates when necessary; label and identify each package with door opening code to match hardware schedule.

1.7.2 Store products in manufacturer's unopened packaging until ready for installation.

1.7.3 Protect materials from exposure to moisture. Do not deliver until after wet work is complete and dry.

1.7.4 Store materials in a dry, warm, ventilated weathertight location.

1.8 PROJECT CONDITIONS

1.8.1 Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

1.9 WARRANTY

1.9.1 Provide factory warranty against defects in material and workmanship as follows:1.9.1.1 Overhead Surface Closers, Grade 1, 25 Year Warranty.1.9.1.2 Overhead Concealed closers 10 Year Warranty.1.9.1.3 Floor Closers 25 Year Warranty.1.9.1.4 Mortise locks, Grade 1, 10 Year Warranty.1.9.1.5 Cylindrical locks, Grade 1, 10 Year Warranty.1.9.1.6 Cylindrical locks, Grade 2, 5 Year Warranty.1.9.1.7 Standard and Interchangeable Cylinders, 2 Year Warranty.1.9.1.8 Patented Key Control SKC Cylinders, Lifetime Warranty.1.9.1.9 Electrical components 2 Year Warranty.1.9.1.10 9000 series exit devices 10 year mechanical / 2 years electrical1.9.1.11 8000 series exit devices 5 year mechanical / 2 years electrical

1.10 MAINTENANCE MATERIALS

1.10.1 Provide special wrenches and tools applicable to each different or special hardware component.

1.11 COORDINATION

1.11.1 Coordinate work with other directly affected components involving manufacture or fabrication of internal reinforcement for door hardware and recessed items.

1.11.2 Coordinate work with other directly affected components involving electrical wiring and components.

08 71 00-4

Page 5: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2 PRODUCTS

2.1 MANUFACTURERS

2.1.1 Acceptable Manufacturer: DORMA, which is located at: Dorma Dr. Drawer AC; Reamstown, PA 17567-0411; Toll Free Tel: 800-523-8483; Tel: 717-336-3881; Fax: 800-274-9724; Email:request info ([email protected]); Web:www.dorma.com

2.1.2 Substitutions: Not permitted.

2.1.3 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00.

2.2 HINGES AND PIVOTS

2.2.1 Hinges: ANSI A156.1, full mortise template type complying with following general requirements unless otherwise scheduled.2.2.1.1 Widths: Sufficient to clear trim projection when door swings 180 degrees.2.2.1.2 Number: Furnish minimum three hinges to 90 inches (2 286 mm) high, four

hinges to 120 inches (3 048 mm) high for each door leaf.2.2.1.2.1 Fire Rated Doors To 86 inches (2 184 mm) High: Minimum three ball

bearing hinges.2.2.1.2.2 Residential Wood Doors: Furnish minimum two hinges.

2.2.1.3 Size and Weight: 4-1/2 inch (114 mm) heavy weight typical for 1-3/4 inch (44 mm) doors.

2.2.1.3.1 Doors Over 40 inches (1 016 mm) Wide: Extra heavy weight ball or oilite bearing hinges.

2.2.1.3.2 Doors 1-3/8 inch (35 mm) Thick: 3-1/2 inch (89 mm) size.2.2.1.3.3 Doors 2 inch (50 mm) Thick: 5 inch (125 mm) extra heavy weight ball or

oilite bearing.2.2.1.3.4 Doors Over 48 inches (1 220 mm) Wide: 5 inch (125 mm) extra heavy

weight ball or oilite bearing.2.2.1.4 Pins: Furnish nonferrous hinges with non-removable pins (NRP) at exterior and

locked outswinging doors, non-rising pins at interior doors.2.2.1.5 Tips: Furnish with matching plug.2.2.1.6 Material: Steel - Polished and plated.2.2.1.7 Material: Steel - Bonderized and prime coated to receive paint.2.2.1.8 Material: Brass - Polished and plated.2.2.1.9 Material: Stainless Steel - Polished and satin finished.

2.2.2 LM Series Pivots: ANSI A156.4, center and offset pivots2.2.2.1 CO7032 Center Pivoted, 440 lb Door Maximum. DORMA LM Series CP440,

CPA440.2.2.2.2 CO7131 Offset Pivoted, Side Jamb Bottom Pivot, 350 lb Door Maximum.

DORMA LM Series OPJ350.2.2.2.3 CO7162 Offset Pivoted, 440/200 lb Door Maximum. DORMA LM Series OP440.2.2.2.4 CO7172 Offset Pivoted, Side Jamb Bottom Pivot, 350 lb Door Maximum.

DORMA LM Series OPJ350.2.2.2.5 CO7202 Offset Pivoted, Labeled Fire Doors, 350 lb Door Maximum. DORMA

LM Series OPF440.2.2.2.6 CO7321 Offset Pivoted, Intermediate Pivot DORMA LM Series 75220, 15220.2.2.2.7 CO7321 Offset Pivoted, Intermediate Pivot, 20 minute Labeled Fire Doors

DORMA LM Series 75222.2.2.2.8 CO7371 Offset Pivoted, Intermediate Pivot, Labeled Fire Doors DORMA LM

Series 75233.2.2.2.9 C07601 Pocket Pivoted, DORMA LM Series 75520 bronze pocket pivot for 90

degree pocket doors.

08 71 00-5

Page 6: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.2.2.10 C07611 Pocket Pivoted, DORMA LM Series 75523 steel pocket pivot for 90 degree pocket doors, UL listed for 20 minute wood fire doors and 3 hour rated steel fire doors.

2.2.2.11 Finish: As specified in the Door Hardware Schedule.2.2.2.12 Standard Sprayed Finish: As selected by the Architect.2.2.2.13 Custom Paint Finish: Optional Special color as selected by the Architect.2.2.2.14 Finish: 689 (Aluminum).2.2.2.15 Finish: 690 (Dark Bronze).2.2.2.16 Finish: 691 (Light Bronze).2.2.2.17 Finish: 693 (Black).2.2.2.18 Finish: 695 (Dark Duronodic Bronze).2.2.2.19 Finish: 696 (Gold).2.2.2.20 Finish: 600 Primer.2.2.2.21 Plated Finish: Brass: 605 (Bright).2.2.2.22 Plated Finish: Brass: 606 (Satin).2.2.2.23 Plated Finish: Bronze: 611 (Bright).2.2.2.24 Plated Finish: Bronze: 612 (Satin).2.2.2.25 Plated Finish: Bronze: 613 (Dark).2.2.2.26 Plated Finish: Nickel: 618 (Bright).2.2.2.27 Plated Finish: Nickel: 619 (Satin).2.2.2.28 Plated Finish: Chrome: 625 (Bright).2.2.2.29 Plated Finish: Chrome: 626 (Satin).

2.3 MORTISE LOCKSETS AND DEADBOLTS

2.3.1 Lockset: DORMA ML9000 Series.2.3.1.1 Standards:

2.3.1.1.1 ANSI Conformance - ANSI A156.13, Operational Grade 1, Security Grade 1.

2.3.1.1.2 U.L. and C.U.L. listed for use on 3-hour fire-rated doors and for all positive pressure applications.

2.3.1.1.3 U.L. and C.U.L. listed for UL 10B/10C.2.3.1.1.4 Lever trim meets A117.1 and ADA requirements.

2.3.1.2 Features:2.3.1.2.1 Stainless steel latch.2.3.1.2.2 Stainless steel dead bolt.2.3.1.2.3 Hardened steel rollers in dead bolt.2.3.1.2.4 Security spacer between inside and outside lever.2.3.1.2.5 Steel lock case and internal components.2.3.1.2.6 Full length face plate.2.3.1.2.7 All trim through-bolted through the lock case.2.3.1.2.8 Accepts standard and interchangeable core cylinders.

2.3.1.3 Function:2.3.1.3.1 As noted on the hardware schedule attached to this section.2.3.1.3.2 As noted on the hardware schedule on the Drawings.2.3.1.3.3 ML9010 - F01 Passage Set2.3.1.3.4 ML9040 - F22 Privacy Lock2.3.1.3.5 ML9050 - F04 Single Cylinder Office Lock2.3.1.3.6 ML9060 - F09 Double Cylinder Entrance or Stairwell Lock2.3.1.3.7 ML9070 - F05 Single Cylinder Classroom Lock2.3.1.3.8 ML9080 - F07 Single Cylinder Storeroom Lock2.3.1.3.9 ML9001 - Single Dummy Trim2.3.1.3.10 ML9953 - F20 Single Cylinder Deadbolt Entrance Lock2.3.1.3.11 MB9960 - F17 Dead Bolt Cylinder by Turn Piece2.3.1.3.12 MB9962 - F16 Dead Bolt Cylinder both sides.

2.3.1.4 Trim:

08 71 00-6

Page 7: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.3.1.4.1 Lever: LRA, 2-1/4 inch (57 mm) rose.2.3.1.4.2 Lever: LRB, 2-9/16 inch (65 mm) rose.2.3.1.4.3 Lever: LRH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.2.3.1.4.4 Lever: LRM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.2.3.1.4.5 Lever: LCA, 2-1/4 inch (57 mm) rose.2.3.1.4.6 Lever: LCB, 2-9/16 inch (65 mm) rose.2.3.1.4.7 Lever: LCH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.2.3.1.4.8 Lever: LCM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.2.3.1.4.9 Lever: LTA, 2-1/4 inch (57 mm) rose.2.3.1.4.10 Lever: LTB, 2-9/16 inch (65 mm) rose.2.3.1.4.11 Lever: LTH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.2.3.1.4.12 Lever: LTM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.2.3.1.4.13 Lever: LGA, 2-1/4 inch (57 mm) rose.2.3.1.4.14 Lever: LGB, 2-9/16 inch (65 mm) rose.2.3.1.4.15 Lever: LGH, 2 inch (51 mm) by 8-1/2 inch (216 mm) escutcheon.2.3.1.4.16 Lever: LGM, 2-1/2 inch (63.5 mm) by 8 inch (203 mm) escutcheon.

2.3.1.5 Lock Cylinder:2.3.1.5.1 DORMA standard keyway with two nickel silver keys.2.3.1.5.2 Interchangeable Core.2.3.1.5.3 Patented SKC key system.

2.3.1.6 Finish:2.3.1.6.1 Finish: As specified in the Door Hardware Schedule.2.3.1.6.2 Brass: 605 (Bright).2.3.1.6.3 Brass: 606 (Satin).2.3.1.6.4 Bronze: 612 (Satin).2.3.1.6.5 Bronze: 613 (Dark).2.3.1.6.6 Chrome: 626 (Satin).2.3.1.6.7 Stainless: 630 (Satin).

2.4 CYLINDRICAL LOCKSETS AND DEADBOLTS

2.4.1 Lockset: DORMA C300 Series, Economy.2.4.1.1 Standards:

2.4.1.1.1 ANSI Conformance - ANSI A156.2, Series 4000, Grade 2.2.4.1.1.2 U.L. and C.U.L. listed for use on 3-hour fire-rated doors and for all positive

pressure applications.2.4.1.1.3 Lever trim meets ANSI A117.1 and ADA requirements.

2.4.1.2 Features:2.4.1.2.1 Concealed fasteners on rose.2.4.1.2.2 Available backset 1-3/8 inch to 1-3/4 inch.2.4.1.2.3 Door thickness range 1-3/8 inch to 1-3/4 inch.

2.4.1.3 Function:2.4.1.3.1 As noted on the hardware schedule attached to this section.2.4.1.3.2 As noted on the hardware schedule on the Drawings.2.4.1.3.3 C301 - Dummy Trim One Side2.4.1.3.4 C310 - Passage/Closet2.4.1.3.5 C330 - Patio2.4.1.3.6 C340 - Privacy, Bedroom, Bath2.4.1.3.7 C353 - Entrance

2.4.1.4 Trim:2.4.1.4.1 Lever: LC, 2-1/2 inch (64 mm) rose.2.4.1.4.2 Lever: LG, 2-1/2 inch (64 mm) rose.2.4.1.4.3 Lever: LR, 2-1/2 inch (64 mm) rose.2.4.1.4.4 Lever: LS, 2-1/2 inch (64 mm) rose.

2.4.1.5 Lock Cylinder:2.4.1.5.1 DORMA standard keyway with two nickel silver keys.

08 71 00-7

Page 8: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.4.1.5.2 Interchangeable core.2.4.1.5.3 Patented SKC key system.

2.4.1.6 Strikes:2.4.1.6.1 ANSI Strike.2.4.1.6.2 T Strike.2.4.1.6.3 Full Lip Strike.

2.4.1.7 Finish:2.4.1.7.1 Finish: As specified in the Door Hardware Schedule.2.4.1.7.2 Brass: 605 (Bright).2.4.1.7.3 Bronze: 613 (Dark).2.4.1.7.4 Nickel 619(Satin).2.4.1.7.5 Chrome: 626 (Satin).

2.4.2 Lockset: DORMA C500 Series.2.4.2.1 Standards:

2.4.2.1.1 ANSI Conformance - ANSI A156.2, Series 4000, Grade 2.2.4.2.1.2 U.L. and C.U.L. listed for use on 3-hour fire-rated doors and for all positive

pressure applications.2.4.2.1.3 U.L. and C.U.L. listed for UL 10B/10C.2.4.2.1.4 Lever trim meets ANSI A117.1 and ADA requirements.

2.4.2.2 Features:2.4.2.2.1 Auxiliary support springs.2.4.2.2.2 Optional through-bolted chassis.2.4.2.2.3 Door thickness range 1-3/8 inch to 1-3/4 inch.

2.4.2.3 Function:2.4.2.3.1 As noted on the hardware schedule attached to this section.2.4.2.3.2 As noted on the hardware schedule on the Drawings.2.4.2.3.3 C501 - Dummy Trim One Side2.4.2.3.4 C510 - Passage/Closet2.4.2.3.5 C525 - Exit Communicating Passage2.4.2.3.6 C530 - Patio2.4.2.3.7 C540 - Privacy, Bedroom, Bath2.4.2.3.8 C550 - Office/Entry2.4.2.3.9 C553 -Entry2.4.2.3.10 C570 - Classroom2.4.2.3.11 C580 - Storeroom

2.4.2.4 Trim:2.4.2.4.1 Lever: LR, 3-15/16 inch (84 mm) rose.2.4.2.4.2 Lever: LC, 3-15/16 inch (84 mm) rose.

2.4.2.5 Lock Cylinder:2.4.2.5.1 DORMA standard keyway with two nickel silver keys.2.4.2.5.2 Patented SKC key system.

2.4.2.6 Strikes:2.4.2.6.1 ANSI Strike.2.4.2.6.2 T Strike.2.4.2.6.3 Full Lip Strike, square corner.2.4.2.6.4 Full Lip Strike, radius corner.

2.4.2.7 Finish:2.4.2.7.1 Finish: As specified in the Door Hardware Schedule.2.4.2.7.2 Brass: 605 (Bright).2.4.2.7.3 Brass: 606 (Satin).2.4.2.7.4 Bronze: 613 (Dark).2.4.2.7.5 Nickel 619 (Satin).2.4.2.7.6 Chrome: 625 (Bright).2.4.2.7.7 Chrome: 626 (Satin).

08 71 00-8

Page 9: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.4.3 Interconnected Lockset: DORMA J300 Series, Light Duty Commercial.2.4.3.1 Standards:

2.4.3.1.1 ANSI Conformance - ANSI A156.2, Grade 2.2.4.3.1.2 U.L. and C.U.L. listed for use on 3-hour fire-rated doors and for all positive

pressure applications.2.4.3.1.3 Lever trim meets ANSI A117.1 and ADA requirements.

2.4.3.2 Features:2.4.3.2.1 Concealed fasteners on outside rose..2.4.3.2.2 Door thickness range 1-3/8 inch to 1-3/4 inch.

2.4.3.3 Function:2.4.3.3.1 As noted on the hardware schedule attached to this section.2.4.3.3.2 As noted on the hardware schedule on the Drawings.2.4.3.3.3 J310 - Entry Single Cylinder2.4.3.3.4 J353 - Entry Double Cylinder

2.4.3.4 Trim:2.4.3.4.1 Lever: LC, 2-1/2 inch (64 mm) rose.2.4.3.4.2 Lever: LG, 2-1/2 inch (64 mm) rose.2.4.3.4.3 Lever: LR, 2-1/2 inch (64 mm) rose.2.4.3.4.4 Lever: LS, 2-1/2 inch (64 mm) rose.

2.4.3.5 Lock Cylinder:2.4.3.5.1 DORMA standard keyway with two nickel silver keys.2.4.3.5.2 Interchangeable core.2.4.3.5.3 Patented SKC key system.

2.4.3.6 Strikes:2.4.3.6.1 Full Lip Striker.2.4.3.6.2 T Strike.2.4.3.6.3 No Lip Strike, Deadbolt Strike.

2.4.3.7 Finish:2.4.3.7.1 Finish: As specified in the Door Hardware Schedule.2.4.3.7.2 Brass: 605 (Bright).2.4.3.7.3 Nickel: 619 (Satin).2.4.3.7.4 Chrome: 626 (Satin).

2.4.4 Lockset: DORMA CL800 Series, Heavy Duty.2.4.4.1 Standards:

2.4.4.1.1 ANSI Conformance - ANSI A156.2, Series 4000, Grade 1.2.4.4.1.2 U.L. and C.U.L. listed for use on 3-hour fire-rated doors and for all positive

pressure applications.2.4.4.1.3 U.L. and C.U.L. listed for UL 10B/10C.2.4.4.1.4 Lever trim meets ANSI A117.1 and ADA requirements.

2.4.4.2 Features:2.4.4.2.1 Stainless steel latch.2.4.4.2.2 Auxiliary deadlocking latch bolt.2.4.4.2.3 Cast stainless steel latch retractor with bronze bearings.2.4.4.2.4 Lock chassis constructed of steel and stainless steel components.2.4.4.2.5 Key-in-lever lock through-bolted.

2.4.4.3 Function:2.4.4.3.1 As noted on the hardware schedule attached to this section.2.4.4.3.2 As noted on the hardware schedule on the Drawings.2.4.4.3.3 CL810 - F75 Passage Set2.4.4.3.4 CL840 - F76A Privacy Lock2.4.4.3.5 CL853 - F109 Entrance/Office Lock2.4.4.3.6 CL860 - F88 Double Cylinder Vestibule Lock2.4.4.3.7 CL870 - F84 Classroom Lock2.4.4.3.8 CL801 (BE) - Single Dummy Trim.

2.4.4.4 Trim:

08 71 00-9

Page 10: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.4.4.4.1 Lever: LR, 3-7/16 inch (87 mm) rose.2.4.4.4.2 Lever: LC, 3-7/16 inch (87 mm) rose.2.4.4.4.3 Lever: LG, 3-7/16 inch (87 mm) rose.

2.4.4.5 Lock Cylinder:2.4.4.5.1 DORMA standard keyway with two nickel silver keys.2.4.4.5.2 Interchangeable core.2.4.4.5.3 Patented SKC key system.

2.4.4.6 Finish:2.4.4.6.1 Finish: As specified in the Door Hardware Schedule.2.4.4.6.2 Brass: 605 (Bright).2.4.4.6.3 Brass: 606 (Satin).2.4.4.6.4 Bronze: 612 (Satin).2.4.4.6.5 Bronze: 613 (Dark).2.4.4.6.6 Chrome: 626 (Satin).2.4.4.6.7 Chrome: 625 (Polished).

2.5 DEAD BOLTS

2.5.1 Tubular Auxiliary Dead Bolts: DORMA DB800 Series.2.5.1.1 Features:

2.5.1.1.1 Solid steel reinforced strike plate.2.5.1.2 Backset: 2-3/4 inch (70 mm) backset 1 inch (25.5 mm) throw dead bolt with

hardened steel roller.2.5.1.3 Lock Cylinder:

2.5.1.3.1 DORMA standard keyway with two nickel silver keys.2.5.1.3.2 Interchangeable core.2.5.1.3.3 Patented SKC key system.

2.5.1.4 Finish:2.5.1.4.1 Finish: As specified in the Door Hardware Schedule.2.5.1.4.2 Chrome: 626 (Satin).2.5.1.4.3 Brass: 605 (Bright).2.5.1.4.4 Brass: 606 (Satin).2.5.1.4.5 Bronze: 612 (Satin).2.5.1.4.6 Bronze: 613E (Satin.

2.5.2 Tubular Auxiliary Dead Bolts: DORMA DB600 Series.2.5.2.1 Standards:

2.5.2.1.1 ANSI Conformance - ANSI A156.5, Grade 2.2.5.2.2 Features:

2.5.2.2.1 Solid steel reinforced strike plate.2.5.2.2.2 Adjustable 2-3/4 inch (70 mm) to 2-3/8 inch (60 mm) backset 1 inch (25.5

mm) throw dead bolt with hardened steel roller.2.5.2.3 Lock Cylinder:

2.5.2.3.1 DORMA standard keyway with two nickel silver keys.2.5.2.3.2 Interchangeable core.2.5.2.3.3 Patented SKC key system.

2.5.2.4 Latch Bolt: 1 inch (25.5 mm) Throw Latch Bolt:2.5.2.4.1 1-1/8 inch (28.5 mm) by 2-1/4 inch (57 mm) front 1 inch (25.5 mm)

diameter, 1 inch (25.5 mm) throw dead bolt with adjustable 2-3/8 inch (60 mm) to 2-3/4 inch (70 mm) backset. Square corner.

2.5.2.4.2 1-1/8 inch (28.5 mm) by 2-1/4 inch (57 mm) front 1 inch (25.5 mm) diameter, 1 inch (25.5 mm) throw dead bolt with adjustable 2-3/8 inch (60 mm) to 2-3/4 inch (70 mm) backset. Drive in.

2.5.2.5 Finish:2.5.2.5.1 Finish: As specified in the Door Hardware Schedule.2.5.2.5.2 Chrome: 626 (Satin).

08 71 00-10

Page 11: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.5.2.5.3 Brass: 605 (Bright).2.5.2.5.4 Brass: 606 (Satin).2.5.2.5.5 Bronze: 612 (Satin).2.5.2.5.6 Bronze: 613E (Satin).

2.6 CYLINDERS

2.6.1 Conventional Lock Cylinder: ANSI A156.5, Grade 1, 6 pin cylinders.

2.6.2 Interchangeable Core Lock Cylinder: ANSI A156.5.2.6.2.1 Pin Count: 7 Pin.

2.6.3 Patented Key Control Cylinders: DORMA SKC (Serialized Key Control) Cylinders, ANSI A156.5, Grade 1, seven nickel-silver pin cylinders.

2.7 KEYING

2.7.1 Keying:2.7.1.1 Keying: Factory Keyed to existing system..2.7.1.2 Keying: Factory Keyed as directed by Architect.2.7.1.3 Keying: Factory Keyed in like-groups2.7.1.4 Keying: Factory Keyed differently.2.7.1.5 Keying: Factory Master keyed.2.7.1.6 Keying: Factory Grand master keyed.2.7.1.7 Keying: Factory Great grand master keyed.2.7.1.8 Include construction keying.2.7.1.9 Interchangeable Core with temporary construction cores.

2.7.2 Keys:2.7.2.1 Nickel silver. Stamp keys with "DO NOT DUPLICATE".2.7.2.2 Nickel silver. Each DORMASKC key and key blank is engraved with a unique

serial number at the factory. Serial numbers are never repeated, allowing identification and tracking of each key.

2.7.2.3 Supply keys in the following minimum quantities:2.7.2.3.1 Master keys 2.2.7.2.3.2 Grand master keys 2.2.7.2.3.3 Great grand master keys 10.2.7.2.3.4 Construction keys 10.2.7.2.3.5 Change keys 2.

2.7.3 Key Cabinet:2.7.3.1 Construction: Sheet steel or aluminum construction, piano hinged door with

cylinder type lock master keyed to building system.2.7.3.2 Size: Size for Project keys plus sufficient space for 10 percent growth.2.7.3.3 Key and key hook labeling system.2.7.3.4 Finish:

2.7.3.4.1 Baked enamel.2.7.3.4.2 Brushed finish.2.7.3.4.3 Manufacturer's standard as selected by the Architect.

2.8 EXIT DEVICES

2.8.1 General:2.8.1.1 DORMA exit devices are listed by U.L. and C.U.L. under their continuing

reinspection programs and conform to standards U.L. 10C and U.B.C. 7-2 (1997) positive pressure testing. They are BHMA certified to the requirements of ANSI A156.3 for Grade 1 exit devices.

08 71 00-11

Page 12: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.8.1.2 Exit Devices: Exit devices shall be type and function as listed in hardware sets. Use fire exit hardware where exit devices are scheduled for fire door assemblies. Where lever handle trim is specified, match lever trim on locksets. Furnish free wheeling lever trim as standard. Construct device touchbar, rail and cover assemblies of heavy gauge solid wrought materials for true architectural finishes. Provide cylinder dogging on all non-rated devices. Furnish all devices with stainless 3/4 inch (19 mm) throw deadlocking latchbolts.

2.8.2 9000 Series, Heavy Duty Exit Device: ANSI A156.3, Grade 1, heavy duty exit devices. Heavy duty RIM devices shall maintain a minimum latch bolt static load rating of 3,000 lbs.2.8.2.1 Model: 9100 Concealed Exit Device, panic listed only.2.8.2.2 Model: 9100LB Concealed Exit Device less bottom rod, panic listed only.2.8.2.3 Model: F9100 LB Concealed Exit Device less bottom rod, and fire listed.2.8.2.4 Model: F9100 Concealed Exit Device Fire listed2.8.2.5 Model: 9300 Rim Device, panic listed only.2.8.2.6 Model: F9300 Rim Device, panic and fire listed.2.8.2.7 Model: HCF9300 Rim Hurricane Rated Exit Device fire listed.2.8.2.8 Model: 9400 Surface Vertical Rod Exit Device, panic listed only.2.8.2.9 Model F9400 Surface Vertical Rod.2.8.2.10 Model: 9400 LB Concealed Exit Device less bottom rod.2.8.2.11 Model: F9400 LB Concealed Exit Device less bottom rod, and fire listed.2.8.2.12 Model: 9500 Mortise Exit Device, panic listed only.2.8.2.13 Model: F9500 Mortise Exit Device, and fire listed.2.8.2.14 Function:

2.8.2.14.1 As noted on the hardware schedule attached to this section.2.8.2.14.2 As noted on the hardware schedule on the Drawings.2.8.2.14.3 YR03 Key retracts latch bolt2.8.2.14.4 YR08 Key locks or unlocks lever handle2.8.2.14.5 R03 Key retracts latch bolt (suffix J for interchangeable core)2.8.2.14.6 R08 Key locks or unlocks lever handle (suffix J for interchangeable core)2.8.2.14.7 HRTO5 Pull Plate with cylinder & thumbpiece2.8.2.14.8 HRT22 Pull Plate with thumbpiece2.8.2.14.9 PRTO3 Pull Plate with cylinder2.8.2.14.10 CD Cylinder Dogging2.8.2.14.11 LBR Less bottom rod2.8.2.14.12 F Fire label device2.8.2.14.13 BPA Battery alarm exit device kit2.8.2.14.14 DE Delayed egress2.8.2.14.15 ES Electronic latch retraction2.8.2.14.16 E Electronic locking or unlocking of trim2.8.2.14.17 MS Request to exit feature2.8.2.14.18 LM Monitors exit device latch bolt2.8.2.14.19 MLR Motorized latch retraction

2.8.2.15 ES105 Power Transfers for all wired electronic functions.2.8.2.16 PS501 Power Supply required for ES.

2.8.2.16.1 Requirements:2.8.2.16.1.1 Input: 120 V.2.8.2.16.1.2 Input Circuit Protection: 1.0 A circuit breaker.2.8.2.16.1.3 Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.2.8.2.16.1.4 Output Circuit Protection: 4 A fuse.2.8.2.16.1.5 Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4

inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.

2.8.2.17 ES100 Power Supply required for DE.2.8.2.17.1 Requirements:

2.8.2.17.1.1 Input: 120 V.

08 71 00-12

Page 13: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.8.2.17.1.2 Input Circuit Protection: 1.0 A circuit breaker.2.8.2.17.1.3 Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.2.8.2.17.1.4 Output Circuit Protection: 4 A fuse.2.8.2.17.1.5 Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4

inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.

2.8.2.18 Power Supply for MLR2.8.2.18.1 Requirements: PS532RF-Power and control (2) exit devices

2.8.2.18.1.1 Input: 110 VAC/60 Hz2.8.2.18.1.2 Output: 2.0 A @ 24 VDC, Class 22.8.2.18.1.3 Enclosure Size: 14 inches H by 16 inches W by 6.5 inches D

2.8.2.18.2 PS610RF-Power and control (1) exit device2.8.2.18.2.1 Input: 110 VAC/60 Hz2.8.2.18.2.2 Output: 1.0 A @ 24 VDC, Class 22.8.2.18.2.3 Enclosure Size: 12.5 inches H by 12.5 inches W by 4 inches D2.8.2.18.2.4 Current: .88A max. inrush, 400mA max. hold2.8.2.18.2.5 24VDC +10% Filtered and regulated power supply; DORMA

PS610RF or PS532RF2.8.2.19 Trim:

2.8.2.19.1 Tubular Pull - T.2.8.2.19.2 Rectangular Pull - R.2.8.2.19.3 Curved Pull - C.2.8.2.19.4 Straight Pull - G.2.8.2.19.5 Lever Model: _____________.2.8.2.19.6 Knob Model: _____________.2.8.2.19.7 Cylinder: _____________.2.8.2.19.8 Mortise Cylinder: _____________.2.8.2.19.9 Electrified Trim: _____________.2.8.2.19.10 Battery Alarm: _____________.

2.8.2.20 Strikes: Provide types suitable for opening.2.8.2.21 Finish:

2.8.2.21.1 Finish: As specified in the Door Hardware Schedule.2.8.2.21.2 Brass: 605 (Bright).2.8.2.21.3 Brass: 606 (Satin).2.8.2.21.4 Bronze: 611 (Bright).2.8.2.21.5 Bronze: 612 (Satin).2.8.2.21.6 Bronze: 613E (Satin).2.8.2.21.7 Nickel: 619 (Satin).2.8.2.21.8 Chrome: 625 (Bright).2.8.2.21.9 Chrome: 626 (Satin).2.8.2.21.10 Stainless: 630 (Satin).2.8.2.21.11 Antimicrobial Protected Coating (AM).2.8.2.21.12 Clear Powder Coating (P).

2.8.3 9000 Series Narrow Stile, Heavy Duty Exit Device: ANSI A156.3, Grade 1, heavy duty exit devices. Narrow Stile RIM devices shall maintain a minimum latch bolt static load rating of 1,500 lbs.2.8.3.1 Model: 9600 Concealed Exit Device, panic listed only.2.8.3.2 Model: 9600LB Concealed Exit Device less bottom rod, panic listed only.2.8.3.3 Model: F9600 LB Concealed Exit Device less bottom rod, and fire listed.2.8.3.4 Model: F9600 Concealed Exit Device Fire listed.2.8.3.5 Model: 9700 Rim Device, panic listed only.2.8.3.6 Model: F9700 Rim Device, panic and fire listed.2.8.3.7 Model: 9800 Surface Vertical Rod Exit Device, panic listed only.2.8.3.8 Model F9800 Surface Vertical Rod.2.8.3.9 Model: 9800 LB Concealed Exit Device less bottom rod.

08 71 00-13

Page 14: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.8.3.10 Model: F9800 LB Concealed Exit Device less bottom rod, and fire listed.2.8.3.11 Function:

2.8.3.11.1 As noted on the hardware schedule attached to this section.2.8.3.11.2 As noted on the hardware schedule on the Drawings.2.8.3.11.3 ZR03 Key retracts latch bolt2.8.3.11.4 ZR08 Key locks or unlocks lever handle2.8.3.11.5 CD Cylinder Dogging2.8.3.11.6 LBR Less bottom rod2.8.3.11.7 F Fire label device2.8.3.11.8 BPA Battery alarm exit device kit2.8.3.11.9 DE Delayed egress2.8.3.11.10 ES Electronic latch retraction2.8.3.11.11 MS Request to exit feature2.8.3.11.12 LM Monitors exit device latch bolt2.8.3.11.13 MLR Motorized latch retraction

2.8.3.12 ES105 Power Transfers for all wired electronic functions.2.8.3.13 PS501 Power Supply required for ES.

2.8.3.13.1 Requirements:2.8.3.13.1.1 Input: 120 V.2.8.3.13.1.2 Input Circuit Protection: 1.0 A circuit breaker.2.8.3.13.1.3 Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.2.8.3.13.1.4 Output Circuit Protection: 4 A fuse.2.8.3.13.1.5 Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4

inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.

2.8.3.14 ES100 Power Supply required for DE.2.8.3.14.1 Requirements:

2.8.3.14.1.1 Input: 120 V.2.8.3.14.1.2 Input Circuit Protection: 1.0 A circuit breaker.2.8.3.14.1.3 Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.2.8.3.14.1.4 Output Circuit Protection: 4 A fuse.2.8.3.14.1.5 Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4

inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.

2.8.3.15 Power Supply for MLR2.8.3.15.1 Requirements: PS532RF-Power and control (2) exit devices

2.8.3.15.1.1 Input: 110 VAC/60 Hz2.8.3.15.1.2 Output: 2.0 A @ 24 VDC, Class 22.8.3.15.1.3 Enclosure Size: 14 inches H by 16 inches W by 6.5 inches D

2.8.3.15.2 PS610RF-Power and control (1) exit device2.8.3.15.2.1 Input: 110 VAC/60 Hz2.8.3.15.2.2 Output: 1.0 A @ 24 VDC, Class 22.8.3.15.2.3 Enclosure Size: 12.5 inches H by 12.5 inches W by 4 inches D2.8.3.15.2.4 Current: .88A max. inrush, 400mA max. hold2.8.3.15.2.5 24VDC +10% Filtered and regulated power supply; DORMA

PS610RF or PS532RF2.8.3.16 Trim:

2.8.3.16.1 Tubular Pull - T.2.8.3.16.2 Rectangular Pull - R.2.8.3.16.3 Curved Pull - C.2.8.3.16.4 Straight Pull - G.2.8.3.16.5 Lever Model: _____________.2.8.3.16.6 Knob Model: _____________.2.8.3.16.7 Cylinder: _____________.2.8.3.16.8 Mortise Cylinder: _____________.2.8.3.16.9 Electrified Trim: _____________.

08 71 00-14

Page 15: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.8.3.16.10 Battery Alarm: _____________.2.8.3.17 Strikes: Provide types suitable for opening.2.8.3.18 Finish:

2.8.3.18.1 Finish: As specified in the Door Hardware Schedule.2.8.3.18.2 Brass: 605 (Bright).2.8.3.18.3 Brass: 606 (Satin).2.8.3.18.4 Bronze: 611 (Bright).2.8.3.18.5 Bronze: 612 (Satin).2.8.3.18.6 Bronze: 613E (Satin).2.8.3.18.7 Nickel: 619 (Satin).2.8.3.18.8 Chrome: 625 (Bright).2.8.3.18.9 Chrome: 626 (Satin).2.8.3.18.10 Stainless: 630 (Satin).2.8.3.18.11 Antimicrobial Protected Coating (AM).2.8.3.18.12 Clear Powder Coating (P).

2.8.4 8000 Series Heavy Duty Exit Device: ANSI A156.3, Grade 1, exit devices.2.8.4.1 Model: 8300 Rim Device, panic listed only.2.8.4.2 Model: F8300 Rim Device, panic and fire listed.2.8.4.3 Model: 8400 Surface Vertical Rod Exit Device, panic listed only.2.8.4.4 Model: F8400 Surface Vertical Rod Exit Device, panic listed and fire listed.2.8.4.5 Model: 8400LB Surface Vertical Rod Exit Device less bottom rod, panic listed

only.2.8.4.6 Function:

2.8.4.6.1 As noted on the hardware schedule attached to this section.2.8.4.6.2 As noted on the hardware schedule on the Drawings.2.8.4.6.3 R03 Key retracts latch bolt (suffix IC for interchangeable core)2.8.4.6.4 R08 Key locks or unlocks lever handle (suffix IC for interchangeable core)2.8.4.6.5 HTSO5 Pull Plate with cylinder and thumbpiece2.8.4.6.6 80O3P Pull with cylinder2.8.4.6.7 LBR Less bottom rod2.8.4.6.8 F Fire label device2.8.4.6.9 BPA Battery alarm exit device kit2.8.4.6.10 ES Electronic latch retraction2.8.4.6.11 MS Request to exit feature2.8.4.6.12 LM Monitors exit device latch bolt

2.8.4.7 ES105 Power Transfer ES105 for all wired electronic functions.2.8.4.8 ES100 Power Supply required for ES.

2.8.4.8.1 Requirements:2.8.4.8.1.1 Input: 120 V.2.8.4.8.1.2 Input Circuit Protection: 1.0 A circuit breaker.2.8.4.8.1.3 Output: 24 VDC, 14-18 A surge, 2 A @ 5 V continuous, per zone.2.8.4.8.1.4 Output Circuit Protection: 4 A fuse.2.8.4.8.1.5 Enclosure: 8 inches (203 mm) H by 8 inches (203 mm) W by 4

inches (102 mm) D NEMA 1 Type enclosure for indoor use with hinged cover and knock-outs.

2.8.4.9 Trim:2.8.4.9.1 Tubular Pull - T.2.8.4.9.2 Rectangular Pull - R.2.8.4.9.3 Curved Pull - C.2.8.4.9.4 Straight Pull - G.2.8.4.9.5 Lever Model: _____________.2.8.4.9.6 Knob Model: _____________.2.8.4.9.7 Cylinder: _____________.2.8.4.9.8 Mortise Cylinder: _____________.2.8.4.9.9 Electrified Trim: _____________.

08 71 00-15

Page 16: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.8.4.9.10 Battery Alarm: _____________.2.8.4.10 Strikes: Provide types suitable for opening.2.8.4.11 Finish:

2.8.4.11.1 Finish: As specified in the Door Hardware Schedule.2.8.4.11.2 Stainless: 630 (Satin).2.8.4.11.3 Powder Coated Aluminum: 689.2.8.4.11.4 Powder Coated Bronze: 691.2.8.4.11.5 Powder Coated Dark Duranodic: 695.2.8.4.11.6 Powder Coated Gold: 696.

2.8.5 Removable Mullions:2.8.5.1 1310 Aluminum Mullion

2.8.5.1.1 Finish: Aluminum: 628 (Satin).2.8.5.1.2 Finish: Bronze: 313 (Dark).

2.8.5.2 1330 Steel Mullion2.8.5.2.1 Finish: Prime: 600.

2.8.5.3 F1300-8 Steel Mullion: For use with U.L. listed fire exit devices. Standard in 8 foot length.

2.8.5.3.1 Finish: Prime 600.2.8.5.4 1300-10 Steel Mullion: 10 foot non-fire-rated mullion

2.8.5.4.1 Finish: Prime 600.2.8.5.5 F1340KR-8 Key Removable Steel Mullion: For use with U.L. listed fire exit

devices. Standard in 8 foot length.2.8.5.5.1 Finish: Prime 600.

2.8.5.6 1340KR-8 Key Removable Steel Mullion: 8 foot non-fire rated2.8.5.6.1 Finish: Prime 600.

2.8.5.7 1340KR-10 Key Removable Steel Mullion: 10 foot non-fire-rated key removable mullion.

2.8.5.7.1 Finish: Prime 600.2.8.5.8 HC1300 Hurricane Rated Steel Mullions: 8 foot non-fire-rated mullion 80 psf

design pressure rating positive/negative deflection with HCF9300 rim device. Tested to Miami-Dade TAS 201, 202, 203.

2.8.5.8.1 Finish: Prime 600.2.8.5.9 1340SK Storage Kit for use with 1340KR Series Mullions: Includes a top fitting

with cylinder, bottom fitting, mounting plate, floor anchors and mounting fasteners.

2.9 SURFACE DOOR CLOSERS

2.9.1 Closers used in conjunction with overhead stops and holders shall be templated and coordinated to function properly. Properly detail closers to meet application requirements by providing drop plates, brackets, etc. to meet application and installation requirements as indicated.

2.9.2 TS93 Series: ANSI A156.4, Grade 1, compact design surface door closer with unique cam and roller design.2.9.2.1 Model TS93-1 features adjustable spring sizes from 1 to 5 and meets the

requirements of ANSI A117.1 and ADA for interior and exterior barrier-free accessibility.

2.9.2.2 Model TS93-5 features adjustable spring sizes from 5 to 6 plus 50 percent adjustment for wide, tall or heavy doors.

2.9.2.3 Model TS93 PKT for pocket door applications.2.9.2.4 Standard independent, latch, sweep and backcheck intensity valves.2.9.2.5 Compliant with UL10C for positive pressure.2.9.2.6 Non-handed.2.9.2.7 Finish: As specified in the Door Hardware Schedule.

08 71 00-16

Page 17: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.9.2.8 Standard Sprayed Finish: As selected.2.9.2.8.1 689 (Aluminum).2.9.2.8.2 690 (Dark Bronze).2.9.2.8.3 691 (Light Bronze).2.9.2.8.4 693 (Black).2.9.2.8.5 695 (Dark Duronodic Bronze).2.9.2.8.6 696 (Gold).2.9.2.8.7 600 Primer.2.9.2.8.8 Custom Paint Finish: Optional Special color as selected by the Architect.

2.9.2.9 Plated Finish:2.9.2.9.1 Brass: 605 (Bright).2.9.2.9.2 Brass: 606 (Satin).2.9.2.9.3 Bronze: 611 (Bright).2.9.2.9.4 Bronze: 612 (Satin).2.9.2.9.5 Bronze: 613 (Dark).2.9.2.9.6 Nickel: 618 (Bright).2.9.2.9.7 Nickel: 619 (Satin).2.9.2.9.8 Chrome: 625 (Bright).2.9.2.9.9 Chrome: 626 (Satin).

2.9.3 8900 Series: ANSI A156.4, Grade 1, heavy duty surface door closer.2.9.3.1 Model 8916 for interior and exterior applications features adjustable spring sizes

from 1 to 6 and meets ANSI A117.1 and ADA for barrier-free accessibility.2.9.3.2 Model 8956 features adjustable spring sizes from 5 to 6 plus 50 percent

adjustment for wide, tall or heavy doors.2.9.3.3 Compliant with UL10C for positive pressure.2.9.3.4 Certified to 10 million cycles by a recognized test lab.2.9.3.5 Non-handed.2.9.3.6 Featuring full range spring power adjustment and backcheck, with a narrow

projection full cover and flatform style arm.2.9.3.7 Door control also features a backcheck positioning adjustment for parallel arm

applications, to maintain an ANSI backcheck range similar to regular and top jamb applications.

2.9.3.8 Independent sweep and latch non-critical closing speed adjustment.2.9.3.9 Finish: As specified in the Door Hardware Schedule.2.9.3.10 Standard Sprayed Finish: As selected.

2.9.3.10.1 689 (Aluminum).2.9.3.10.2 690 (Dark Bronze).2.9.3.10.3 691 (Light Bronze).2.9.3.10.4 693 (Black).2.9.3.10.5 695 (Dark Duronodic Bronze).2.9.3.10.6 696 (Gold).2.9.3.10.7 600 Primer.2.9.3.10.8 Custom Paint Finish: Optional Special color as selected by the Architect.

2.9.3.11 Plated Finish:2.9.3.11.1 Brass: 605 (Bright).2.9.3.11.2 Brass: 606 (Satin).2.9.3.11.3 Bronze: 611 (Bright).2.9.3.11.4 Bronze: 612 (Satin).2.9.3.11.5 Bronze: 613 (Dark).2.9.3.11.6 Nickel: 618 (Bright).2.9.3.11.7 Nickel: 619 (Satin).2.9.3.11.8 Chrome: 625 (Bright).2.9.3.11.9 Chrome: 626 (Satin).

2.9.4 8600 Series: ANSI A156.4, Grade 1, surface door closer.

08 71 00-17

Page 18: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.9.4.1 Model 8616 for interior and exterior applications and meets ANSI A117.1 and ADA for barrier-free accessibility.

2.9.4.2 Model 8616 features adjustable spring sizes from 1 to 6.2.9.4.3 Compliant with UL10C for positive pressure.2.9.4.4 Non-handed.2.9.4.5 Door control also features a backcheck positioning adjustment for parallel arm

applications, to maintain an ANSI backcheck range similar to regular and top jamb applications.

2.9.4.6 Independent sweep and latch non-critical closing speed adjustment.2.9.4.7 Finish: As specified in the Door Hardware Schedule.2.9.4.8 Standard Sprayed Finish: As selected.

2.9.4.8.1 689 (Aluminum).2.9.4.8.2 690 (Dark Bronze).2.9.4.8.3 691 (Light Bronze).2.9.4.8.4 693 (Black).2.9.4.8.5 695 (Dark Duronodic Bronze).2.9.4.8.6 696 (Gold).2.9.4.8.7 600 Primer.2.9.4.8.8 Custom Paint Finish: Optional Special color as selected by the Architect.

2.9.4.9 Plated Finish:2.9.4.9.1 Brass: 605 (Bright).2.9.4.9.2 Brass: 606 (Satin).2.9.4.9.3 Bronze: 611 (Bright).2.9.4.9.4 Bronze: 612 (Satin).2.9.4.9.5 Bronze: 613 (Dark).2.9.4.9.6 Nickel: 618 (Bright).2.9.4.9.7 Nickel: 619 (Satin).2.9.4.9.8 Chrome: 625 (Bright).2.9.4.9.9 Chrome: 626 (Satin).

2.9.5 7400 Series: ANSI A156.4, Grade 1, surface door closer.2.9.5.1 Model 7414 for interior and exterior applications and meets ANSI A117.1 and

ADA for barrier-free accessibility. Features adjustable spring sizes from 1 to 4.2.9.5.2 Model 7436 for interior and exterior applications. Features adjustable spring

sizes from 3 to 6.2.9.5.3 Compliant with UL10C for positive pressure.2.9.5.4 Non-handed.2.9.5.5 Door control features a backcheck adjustment and adjustable spring sizes.2.9.5.6 Independent sweep and latch non-critical closing speed adjustment.2.9.5.7 Finish: As specified in the Door Hardware Schedule.2.9.5.8 Standard Sprayed Finish: As selected.

2.9.5.8.1 689 (Aluminum).2.9.5.8.2 690 (Dark Bronze).2.9.5.8.3 691 (Light Bronze).2.9.5.8.4 693 (Black).2.9.5.8.5 695 (Dark Duronodic Bronze).2.9.5.8.6 696 (Gold).2.9.5.8.7 600 Primer.2.9.5.8.8 Custom Paint Finish: Optional Special color as selected by the Architect.

2.9.6 7300 Series: ANSI A156.4, Grade 1, surface door closer.2.9.6.1 Features fixed spring sizes 2, 3, 4, and 5.2.9.6.2 Compliant with UL10C for positive pressure.2.9.6.3 Independent sweep and latch non-critical closing speed adjustment.2.9.6.4 Non-handed.2.9.6.5 Adjustable backcheck.

08 71 00-18

Page 19: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.9.6.6 Finish: As specified in the Door Hardware Schedule.2.9.6.7 Standard Sprayed Finish: As selected.2.9.6.8 Custom Finish: Optional Special color.

2.9.7 STA Series: ANSI A156.4, Grade 1, corrosion resistant surface door closer.2.9.7.1 Model STA8616 for interior and exterior applications and meets ANSI A117.1

and ADA for barrier-free accessibility. Model 8616 features adjustable spring sizes from 1 to 6.

2.9.7.2 Model STA7414 for interior and exterior applications and meets ANSI A117.1 and ADA for barrier-free accessibility. Model 7414 features adjustable spring sizes from 1 to 4.

2.9.7.3 Model 7436 features adjustable spring sizes from 3 to 6.2.9.7.4 Compliant with UL10C for positive pressure.2.9.7.5 Non-handed.2.9.7.6 Stainless steel S-IS option available for use in severe climate conditions, or

where there is exposure to corrosive environments.2.9.7.7 Finish: As specified in the Door Hardware Schedule.2.9.7.8 Standard Sprayed Finish: As selected by the Architect.2.9.7.9 Custom Paint Finish: Optional Special color as selected by the Architect.

2.9.8 Spring Assist Arm Dead Stop: ANSI A156.4, Grade 1, DORMA Spring Assist Arm Systems for high volume high traffic applications. Meets requirements for UL10C for positive pressure (non-hold open).2.9.8.1 Model S-DS heavy duty, dead stop, parallel arm, pull side mount.2.9.8.2 Model S-IS regular, dead stop and top jamb mount, push side mount.2.9.8.3 Arms:

2.9.8.3.1 Heavy-Duty Parallel Arm x Spring Door Saver:2.9.8.3.2 Regular x Spring Integra Stop Arm:2.9.8.3.3 Top Jamb x Spring Integra Stop Arm

2.9.8.4 Finish: As specified in the Door Hardware Schedule.2.9.8.5 Standard Sprayed Finish: As selected.2.9.8.6 Custom Paint Finish: Optional Special color as selected by the Architect.2.9.8.7 Finish: 689 (Aluminum).2.9.8.8 Finish: 690 (Dark Bronze).2.9.8.9 Finish: 691 (Light Bronze, Dull).2.9.8.10 Finish: 695 (Dark Duronodic Bronze).2.9.8.11 Finish: 696 (Gold).2.9.8.12 Finish: 693 (Black).2.9.8.13 Finish: 600 Primer.

2.10 CONCEALED DOOR CLOSERS

2.10.1 BTS75V Series: ANSI A156.4, Grade 1, compact design floor-concealed door closers.2.10.1.1 Adjustable spring power allows the necessary adjustment.2.10.1.2 Controlled closing with two independent valves.2.10.1.3 Model BTS75V BF meets the requirements of ANSI A117.1 and ADA for barrier-

free accessibility.2.10.1.4 Non-handed.2.10.1.5 Finish: As specified in the Door Hardware Schedule.2.10.1.6 Standard Sprayed Finish: As selected as selected by the Architect.2.10.1.7 Custom Paint Finish: Optional Special color as selected by the Architect.2.10.1.8 Plated Finish: Brass: 605 (Bright).2.10.1.9 Plated Finish: Brass: 606 (Satin).2.10.1.10 Plated Finish: Bronze: 611 (Bright).2.10.1.11 Plated Finish: Bronze: 612 (Satin).2.10.1.12 Plated Finish: Bronze: 613 (Dark).

08 71 00-19

Page 20: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.10.1.13 Plated Finish: Nickel: 618 (Bright).2.10.1.14 Plated Finish: Nickel: 619 (Satin).2.10.1.15 Plated Finish: Chrome: 625 (Bright).2.10.1.16 Plated Finish: Chrome: 626 (Satin).

2.10.2 BTS80 Series: ANSI A156.4, Grade 1, compact design floor-concealed door closers.2.10.2.1 Field selectable either multipoint hold open between 75 and 175 degrees or

selectable delayed action to allow delayed closing from 175 to 75 degrees.2.10.2.2 A wide selection of interchangeable spindles offers suitability for virtually any

floor covering or threshold application.2.10.2.3 Model BTS80 E for exterior application.2.10.2.4 Model BTS80 BFE: Meets ADA barrier-free accessibility requirements for

exterior use.2.10.2.5 Non-handed.2.10.2.6 Finish: As specified in the Door Hardware Schedule.2.10.2.7 Standard Sprayed Finish: As selected as selected by the Architect.2.10.2.8 Custom Paint Finish: Optional Special color as selected by the Architect.2.10.2.9 Plated Finish: Brass: 605 (Bright).2.10.2.10 Plated Finish: Brass: 606 (Satin).2.10.2.11 Plated Finish: Bronze: 611 (Bright).2.10.2.12 Plated Finish: Bronze: 612 (Satin).2.10.2.13 Plated Finish: Bronze: 613 (Dark).2.10.2.14 Plated Finish: Nickel: 618 (Bright).2.10.2.15 Plated Finish: Nickel: 619 (Satin).2.10.2.16 Plated Finish: Chrome: 625 (Bright).2.10.2.17 Plated Finish: Chrome: 626 (Satin).

2.10.3 ITS96-1 Series: Compact design overhead-concealed door closers.2.10.3.1 Aluminum alloy body with high compression steel springs and steel cams and

rollers for doors opening up to 130 degrees maximum.2.10.3.2 Two noncritical thermostatic valves to separately control sweep and latch speeds

and provide constant closing speeds.2.10.3.3 Adjustable springs to meet the requirements of ADA for barrier-free accessibility.2.10.3.4 Compliant with UL10C for positive pressure.2.10.3.5 Finish: As specified in the Door Hardware Schedule.2.10.3.6 Standard Sprayed Finish: As selected as selected by the Architect.2.10.3.7 Custom Paint Finish: Optional Special color as selected by the Architect.2.10.3.8 Finish: Bronze: 691 (Dull).2.10.3.9 Finish: Statuary Bronze: 690.2.10.3.10 Finish: Dark Duranodic Bronze: 695.2.10.3.11 Finish: Gold: 696.2.10.3.12 Finish: Black: 693.2.10.3.13 Finish: Primed for Painting: 600.

2.10.4 RTS88 Series: Compact design overhead-concealed door closers.2.10.4.1 Cast Iron body with steel springs and steel cams and rollers for doors opening

up to 90 to 105 degrees maximum.2.10.4.2 Two noncritical valves to separately control sweep and latch speeds and provide

constant closing speeds.2.10.4.3 Finish: As specified in the Door Hardware Schedule.2.10.4.4 Standard Sprayed Finish: As selected as selected by the Architect.2.10.4.5 Custom Paint Finish: Optional Special color as selected by the Architect.2.10.4.6 Plated Finish: Brass: 605 (Bright).2.10.4.7 Plated Finish: Brass: 606 (Satin).2.10.4.8 Plated Finish: Bronze: 611 (Bright).2.10.4.9 Plated Finish: Bronze: 612 (Satin).

08 71 00-20

Page 21: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.10.4.10 Plated Finish: Bronze: 613 (Dark).2.10.4.11 Plated Finish: Nickel: 618 (Bright).2.10.4.12 Plated Finish: Nickel: 619 (Satin).2.10.4.13 Plated Finish: Chrome: 625 (Bright).2.10.4.14 Plated Finish: Chrome: 626 (Satin).

2.11 LOW ENERGY OPERATORS

2.11.1 ED800 Series: ANSI A156.19, Grade 1, surface applied power assist and low energy power operated doors.2.11.1.1 Closer with latch, sweep and backcheck intensity valves.2.11.1.2 Compliant with UL10C for positive pressure.2.11.1.3 Non-handed.2.11.1.4 Wired Wall Switch: WS-1 with Logo and PRESS TO OPEN, 6 inch (152 mm) by

6 inch (152 mm) stainless steel wall plate.2.11.1.5 Wired Narrow Frame Wall Switch: FS-1 with Logo and PRESS TO OPEN, 1-3/4

inch (44 mm) by 4.5 inch (114 mm) stainless steel wall plate.2.11.1.6 Wireless Wall Switch: WSRFT-1 with Logo and PRESS TO OPEN, 6 inch (152

mm) by 6 inch (152 mm) stainless steel wall plate with 1-3/4 inch (44 mm) deep mounting box.

2.11.1.7 Receiver: 800 RFR Hard wired receiver mounted separately.2.11.1.8 Power requirements: 120 VAC, 50/60 Hz, 2 amp.2.11.1.9 Finish: As specified in the Door Hardware Schedule.2.11.1.10 Standard Sprayed Finish: As selected by the Architect.2.11.1.11 Custom Paint Finish: Optional Special color as selected by the Architect.2.11.1.12 Finish: 689 (Aluminum).2.11.1.13 Finish: 690 (Dark Bronze).2.11.1.14 Finish: 691 (Light Bronze).2.11.1.15 Finish: 693 (Black).2.11.1.16 Finish: 695 (Dark Duronodic Bronze).2.11.1.17 Finish: 696 (Gold).2.11.1.18 Finish: 600 Primer.

2.12 FIRE/LIFE SAFETY DEVICES

2.12.1 EM Series: ANSI A156.15, Grade 1 electromagnetic door holder device.2.12.1.1 Floor mount. Single or double magnet.2.12.1.2 Semi-Flush wall mount.2.12.1.3 Surface wall mount.2.12.1.4 Power requirements: 120 VAC, 24 VDC or 24 VAC input.2.12.1.5 Finish: As specified in the Door Hardware Schedule.2.12.1.6 Standard Finish: As selected by the Architect.2.12.1.7 Powder Coated Finish: 689 (Aluminum).2.12.1.8 Powder Coated Finish: 695 (Dark Duronodic Bronze).2.12.1.9 Sprayed Finish: 696 (Gold).

2.13 MISCELLANEOUS TRIM

2.13.1 Push/Pulls: ANSI A156.6; push plates minimum 0.050 inch (1.27 mm) thick.2.13.1.1 Type:

2.13.1.1.1 Straight.2.13.1.1.2 Offset.2.13.1.1.3 Flush.2.13.1.1.4 Straight push-pull.2.13.1.1.5 Offset push-pull.2.13.1.1.6 Push-pull plate.2.13.1.1.7 Provide as indicated on the Schedule.

08 71 00-21

Page 22: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.13.1.2 Size: Push plates shall be ANSI J302, size 4 inches (102 mm) by 16 inches (406 mm), thickness .050 inch.

2.13.1.3 Size: Pull plates shall be ANSI J405, size 4 inches (102 mm) by 16 inches (406 mm), thickness .050 inch.

2.13.1.4 Cut plates for cylinder or thumb piece when used with deadlock.2.13.1.5 Provide with through bolts to secure from opposite door face.2.13.1.6 Finish: As specified in the Door Hardware Schedule.

2.13.2 Flush Bolts: ANSI A156.16 Grade 1 top and bottom flush bolts, with dust-proof floor strike.2.13.2.1 Manual.2.13.2.2 Automatic.2.13.2.3 Provide as indicated on the Schedule.2.13.2.4 Finish: As specified in the Door Hardware Schedule.

2.13.3 Kickplates, Mop Plate, Armor Plates: ANSI A156.6, metal; height indicated in Schedule by 1 inch (25 mm) less than door width:2.13.3.1 Minimum 0.050 inch (1.27 mm) thick stainless steel.2.13.3.2 Height: 8 inches (203 mm).2.13.3.3 Width: 2 inches (51 mm) less than the width of each door..2.13.3.4 Provide as indicated on the Schedule.

2.13.4 Weatherstripping and thresholds specified in Section 08 71 70.

2.13.5 Fire rated gaskets at perimeter of doors specified in Section 07 84 13.

2.13.6 Stops: Provide for all doors to control the desired limit of opening helping to prevent damage to adjacent walls, columns, equipment, the door or its hardware2.13.6.1 Provide floor or wall stops when overhead stops have not been listed except in

areas where their location would impede traffic. Stops of correct height shall be used on exterior and interior doors.

2.13.6.2 Doors with surface closers may be provided with S-DS or S-IS dead stop arms2.13.6.3 Use roller type stops in areas where the interfering swing of one door may cause

damage through contact with another door.2.13.6.4 Wall Stops: ANSI A156.1, Grade 1, with no visible screws:

2.13.6.4.1 3 inch (75 mm) wall stop.2.13.6.4.2 2-1/2 inch (6.35 mm) wall stop.2.13.6.4.3 Convex pad wall stop.2.13.6.4.4 Concave pad wall stop.2.13.6.4.5 Provide as indicated on the Schedule.2.13.6.4.6 Finish: As specified in the Door Hardware Schedule.

2.13.6.5 Floor Stops: ANSI A156.1 Grade 1:2.13.6.5.1 Dome type.2.13.6.5.2 Standard floor type.2.13.6.5.3 Standard floor type with no visible screws2.13.6.5.4 Provide as indicated on the Schedule.2.13.6.5.5 Finish: As specified in the Door Hardware Schedule.

2.13.6.6 Roller Latch Angle Stops: Special angle stop ANSI A156.16 Type E19111.

2.13.7 Standard Duty Door Stops and Holders: 700 Series, Standard Duty door stops and holders. Conforms to ANSI A156.8 Grade 3.2.13.7.1 Type:

2.13.7.1.1 700S: Surface applied stop only.2.13.7.1.2 700H: Surface applied stop and hold open.2.13.7.1.3 700F: Surface applied stop friction.2.13.7.1.4 710S: Concealed stop only.2.13.7.1.5 710H: Concealed hold open.

08 71 00-22

Page 23: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.13.7.1.6 710F: Concealed stop friction.2.13.7.2 Built-in cushioned stop.2.13.7.3 Non-handed.2.13.7.4 Adjustable friction tension with friction stop unit2.13.7.5 Finish: As specified in the Door Hardware Schedule.2.13.7.6 Standard Sprayed Finish: As selected.

2.13.7.6.1 689 (Aluminum).2.13.7.6.2 690 (Dark Bronze).2.13.7.6.3 691 (Light Bronze).2.13.7.6.4 693 (Black).2.13.7.6.5 695 (Dark Duronodic Bronze).2.13.7.6.6 696 (Gold).2.13.7.6.7 600 Primer.2.13.7.6.8 Custom Paint Finish: Optional Special color as selected by the Architect.

2.13.7.7 Plated Finish:2.13.7.7.1 Brass: 605 (Bright).2.13.7.7.2 Brass: 606 (Satin).2.13.7.7.3 Bronze: 611 (Bright).2.13.7.7.4 Bronze: 612 (Satin).2.13.7.7.5 Bronze: 613 (Dark).2.13.7.7.6 Nickel: 618 (Bright).2.13.7.7.7 Nickel: 619 (Satin).2.13.7.7.8 Chrome: 625 (Bright).2.13.7.7.9 Chrome: 626 (Satin).

2.13.8 Heavy Duty Door Stops and Holders: 900 Heavy-Duty door stops and holders. Conforms to ANSI A156.8 Grade 1.2.13.8.1 Type:

2.13.8.1.1 900S: Surface applied stop only.2.13.8.1.2 900H: Surface applied stop and hold open.2.13.8.1.3 900F: Surface applied stop friction.2.13.8.1.4 910S: Concealed stop only.2.13.8.1.5 910H: Concealed hold open.2.13.8.1.6 910F: Concealed stop friction.

2.13.8.2 Built-in cushioned stop2.13.8.3 Non-handed2.13.8.4 Finish: As specified in the Door Hardware Schedule.2.13.8.5 Standard Sprayed Finish: As selected.

2.13.8.5.1 689 (Aluminum).2.13.8.5.2 690 (Dark Bronze).2.13.8.5.3 691 (Light Bronze).2.13.8.5.4 693 (Black).2.13.8.5.5 695 (Dark Duronodic Bronze).2.13.8.5.6 696 (Gold).2.13.8.5.7 600 Primer.2.13.8.5.8 Custom Paint Finish: Optional Special color as selected by the Architect.

2.13.8.6 Plated Finish:2.13.8.6.1 Brass: 605 (Bright).2.13.8.6.2 Brass: 606 (Satin).2.13.8.6.3 Bronze: 611 (Bright).2.13.8.6.4 Bronze: 612 (Satin).2.13.8.6.5 Bronze: 613 (Dark).2.13.8.6.6 Nickel: 618 (Bright).2.13.8.6.7 Nickel: 619 (Satin).2.13.8.6.8 Chrome: 625 (Bright).2.13.8.6.9 Chrome: 626 (Satin).

08 71 00-23

Page 24: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

2.13.9 Coordinators: GSR Series, ANSI A156.4 Grade 1, coordinator system for proper sequential closing of pairs of doors equipped with astragals or exit devices.2.13.9.1 TS93 GSR with two TS93 closers and a GSR mechanism to control sequential

closing for pairs of doors.2.13.9.2 TS93-1 GSR meets the requirements of ANSI A117.1 and ADA for barrier-free

accessibility.2.13.9.3 8956 GSR Series with two 8956 surface closers and a GSR mechanism to

control sequential closing for pairs of doors.2.13.9.4 Non-handed.2.13.9.5 Compliant with UL10C for positive pressure.2.13.9.6 Active door field-selectable.2.13.9.7 Finish: As specified in the Door Hardware Schedule.2.13.9.8 Standard Sprayed Finish: As selected.

2.13.9.8.1 689 (Aluminum).2.13.9.8.2 690 (Dark Bronze).2.13.9.8.3 691 (Light Bronze).2.13.9.8.4 693 (Black).2.13.9.8.5 695 (Dark Duronodic Bronze).2.13.9.8.6 696 (Gold).2.13.9.8.7 600 Primer.2.13.9.8.8 Custom Paint Finish: Optional Special color as selected by the Architect.

2.13.9.9 Plated Finish:2.13.9.9.1 Brass: 605 (Bright).2.13.9.9.2 Brass: 606 (Satin).2.13.9.9.3 Bronze: 611 (Bright).2.13.9.9.4 Bronze: 612 (Satin).2.13.9.9.5 Bronze: 613 (Dark).2.13.9.9.6 Nickel: 618 (Bright).2.13.9.9.7 Nickel: 619 (Satin).2.13.9.9.8 Chrome: 625 (Bright).2.13.9.9.9 Chrome: 626 (Satin).

2.13.10 Silencers for Metal Door Frames: ANSI A156.16, Type L03011; grey rubber, minimum diameter 1/2 inch (13 mm); fabricated for drilled-in application to frame, specifically designed to form an air pocket to absorb shock and reduce noise of door closing. Provide 2 silencers for each pair of doors, 3 silencers for each single door.

3 EXECUTION

3.1 EXAMINATION

3.1.1 Do not begin installation until substrates have been properly prepared.

3.1.2 Verify doors and frames are ready to receive door hardware and dimensions are as indicated on shop drawings.

3.1.3 Verify electric power is available to power operated devices and is of correct characteristics.

3.1.4 If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 INSTALLATION

3.2.1 Install in accordance with manufacturer's instructions.

3.2.2 Coordinate mounting heights with door and frame manufacturers. Use templates provided by hardware item manufacturer.

08 71 00-24

Page 25: €¦ · Web viewHardware Supplier Personnel: Employ Architectural Hardware Consultant (AHC) or equally qualified person to supervise and prepare all schedules, details, and services

3.2.3 Install with fasteners provided by hardware item manufacturer.

3.2.4 Adjust hardware for smooth operation.

3.3 PROTECTION

3.3.1 Protect installed products until completion of project.

3.3.2 Touch-up, repair or replace damaged products before Substantial Completion.

3.4 DOOR HARDWARE SCHEDULE

3.4.1 Provide the following hardware sets ........Hardware Set 1: Fire rated.

Hinges:

Lock:

Closer:

Kickplate:

Gaskets:

Floor Stop:

Hardware Set 2: Non-fire rated.

Hinges:

Latch Set:

Floor Stop:

Silencers:

END OF SECTION