we will start in a few minutes - c.ymcdn.comc.ymcdn.com/sites/ · we will start in a few minutes...

34
COAL USERS’ GROUP www.prbcoals.com 1 We will start in a few minutes Enjoy the music of Tig Wired

Upload: hoangnga

Post on 11-Apr-2018

216 views

Category:

Documents


4 download

TRANSCRIPT

COAL USERS’ GROUPwww.prbcoals.com 1

We will start in a

few minutesEnjoy the music of Tig Wired

www.prbcoals.com 2

An Interactive Conversation on Coal +

COAL USERS’ GROUP3

John BridsonChairman, Board of Directors

– PRB Coal Users’ Group

andVice President, Westar Energy

www.prbcoals.com

COAL USERS’ GROUP

Annual Meeting

Plant of the Year

Industry/Best Practices

E-Learning (Combustible Dust)

Interactive Forum

Promote the SAFE and efficient use of coals by those who are using it or those who are considering its use

www.prbcoals.com 4

COAL USERS’ GROUPwww.prbcoals.com 5

Coal Handling

Jim Wiseman

Vice Chairman – Suppliers, PRBCUG / Wiseman Consulting

Boiler and Combustion

Don Pearson

Retired, Board of Directors, PRBCUG / B & W

Safety, Health, & Fire Protection

Bob Taylor

Secretary, PRBCUG / Retired - AEP

COAL USERS’ GROUPwww.prbcoals.com 6

COAL USERS’ GROUPwww.prbcoals.com 7

COAL USERS’ GROUP

Robert E. Sommerlad, Consultant

Donald B. Pearson, The Babcock & Wilcox Co.(Retired),

Secretary, PRB Coal Users Group

Grant E. Grothen, Burns & McDonnell,

and Steven McCaffrey, Greenbank Energy Solutions

TransAlta Centralia Plant PRB Coal Users’ Plant of the Year

Open House Seminar – September 16-17, 2013

www.prbcoals.com 8

COAL USERS’ GROUP

1960s - Industrial Waste

1970s - Municipal Solid Waste

1980s - Hazardous Waste & Medical Waste

2000s - Energy, and other environmental issues

2011 - Renaissance

Fuel Delivery System Upgrades for Utility Boilers Subcommittee

Subcommittee deals with coal-fired boilers and the fuel delivery system evaluating upgrades & benefits; costs & savings

www.prbcoals.com 9

COAL USERS’ GROUP

* Robert Chase, Terrasource

(Supplier)

* Blaz Jurko, Gebr. Pfeiffer, Inc.

(Supplier)

* David J. Stopek, Consultant,

Sargent & Lundy LLC (Consultant)

*Grant E. Grothen, Principal,

Burns & McDonnell (Consultant)

* Steve McCaffrey, President,

Greenbank Energy (Supplier)

*Melanie Green, Director, CPS

Energy (User)

* Don B. Pearson, Babcock &

Wilcox (Retired) (Supplier)

* Richard Himes, EPRI (User)

* Tony Licata, Licata EEC & Chair

RC EEW (Supplier)

* Robert E. Sommerlad, Consultant

& Chair, FDS Subcommittee

(Consultant)

* Todd Melick, Vice President,

Promecon USA (Supplier)

* Joe Von der Haar, Plant Manager,

East Kentucky Power (User)

www.prbcoals.com 10

COAL USERS’ GROUP

• Plant Retirements

• Focus on 35- to 45- year old coal-fired units

• Fuel Delivery System

• Potential Upgrades

• Methodology – Present status; Determine Upgrades & Benefits: Costs & Savings; Breakevens

• Case Studies – 500-MW units converted to PRB Coal

1. Opposed Wall

2. Tangential

3. Cyclone

• Results

www.prbcoals.com 11

COAL USERS’ GROUP

Given: A group of boilers will be retired putting increased

performance requirements on the next younger boilers.

To Prove: Younger group of boilers can be upgraded and achieve

significant benefits

Analogies:

• Analyze critical parts of typical coal-fired power plant

• Select Fuel Delivery System as the carburetor of the system

• Consider, select potential upgrades, and cost same

• Determine potential benefits, and savings

• Evaluate, review, re-review, and report

• “To Prove” proven

www.prbcoals.com 12

www.prbcoals.com 13

Greater than 50 years – 53 GW or 20% of fleet

30 to 45 year old units – 216 GW or 63% - 500 MW

www.prbcoals.com 14

30 to 45 year old with >50 year old gone

75% of fleet and Capacity Factor near 80%

COAL USERS’ GROUP

Coal Bunker

Burners

Furnace

Burners

Coal to Burner

Coal to Burner

Primary AirMill

Tempering Air

Feeder

www.prbcoals.com 15

COAL USERS’ GROUP

Component Upgrade Benefit

Feeders Metering Flow control

Pulverizers Dynamic

Classifier

Fineness/Capacit

y

Coal Pipes Coal-air flow

Metering

Flow & Air/Fuel

Ratio

Burners Metering Improved

combustion

Boiler Control

System

Neural Networks Improved

performance

www.prbcoals.com 16

COAL USERS’ GROUP

*Based on real 35- to 45- year

old 500-MW boilers now firing

PRB coal & derated

*No Air Quality Control System

Upgrades

*No increase in emissions to

avoid NSR & PSD

1. Opposed-Wall

2. Tangential

3. CycloneCoal fleet boiler design

www.prbcoals.com 17

COAL USERS’ GROUP

Component

Feeder

Pulverizer

Coal Pipes

Burner Modernization

Boiler Control System

Upgrade

New Feeder

Dynamic Classifier

Coal-air flow

LNBs & OFA

Neural Network

www.prbcoals.com 18

COAL USERS’ GROUP

Component Upgrade Benefits

Feeder New Feeders Improved Flow Control

Pulverizer Dynamic Classifiers Increase Fineness (X50

Mesh) & Capacity (~5% )

Coal Pipes Coal-air flow Improved Flow Control

Burner Modernization LNBs & OFA NOx and UBC; <NH3

Boiler Control System Neural Network Improve Boiler

Efficiency & Fan Power;

<NH3

www.prbcoals.com 19

COAL USERS’ GROUP

0

10

20

30

40

50

60

70

R533 R593

Mill Type

Cap

acity

& F

inen

ess

Incr

ease

s, %

Capacity

Increase, %

Fineness

Increase, %

0

10

20

30

40

50

60

R643 R643 R673

Mill Type

Cap

acit

y &

Fin

en

ess In

cre

ase, %

Capacity

Increase, %

Fineness

Increase, %

Courtesy of Loesche Energy Systems

www.prbcoals.com 20

COAL USERS’ GROUP

Component Upgrade Cost, $k Savings, $k/y

Feeder New Feeders 900 Combine with DCs

Pulverizer Dynamic

Classifiers

3,600 5% “Recovery” 8,760

2 Days Op 960

Subtotal 9,720

Coal Pipes Coal-air flow 700 Combine with BCS

Burner Mods LNBs & OFA 5,400 NH3 210

Boiler Control

System

Neural

Network 300

Subtotal 10,900

Efficiency 596

Fan 314

NH3 85

Subtotal 995

PM&ES 25% 2,725

Total 13,625 10,925

Breakeven 15 months

www.prbcoals.com 21

COAL USERS’ GROUP

Component Upgrade Cost, $k Savings, $k/y

Feeder New Feeders 750 Combine with DCs

Pulverizer Dynamic

Classifiers

3,000

5% “Recovery” 8,760

2 Days Op 960

Subtotal 9,720

Coal Pipes Coal-air flow 584 Combine with BCS

Burner Mods

(Burners & SOFA)

New Burners &

SOFA & Other 4,800

Some NOx, UBC but no

significant savings 0

Boiler Control

System

Subtotal

Neural

Network 300

9,434

Efficiency 596

Fan 314

Subtotal 910

PM & ES 25% 2,359

Total 11,763 10,630

Breakeven 13 months

www.prbcoals.com 22

COAL USERS’ GROUP

Component Upgrade Cost, $k Savings, $k/y

Feeder/Crusher

“Island”

New Feeders

&

Instrumentation 1,200

Combine with

Cyclone

Modernization

Cyclone

Modernization

Cyclone

upgrades and

new “Split” air

damper 2,880

Regain 7 days

full load oper-

ation due to

slagging 3,360

Boiler Control

System

Update Boiler

Control System 400

Subtotal 4,480

Efficiency 268

Fan 57

Subtotal 455

PM & ES 25% 1,120

Total 5,600 3,815

Breakeven 18 months

www.prbcoals.com 23

COAL USERS’ GROUP

Case

Study

Type Cost,

$k

Savings,

$k/y

Breakeven,

Months

1 Opposed Wall 13,625 10,925 15

2 Tangential 11,697 10,630 13

3 Cyclone 5,600 3,815 18

500 MW, 80% Capacity Factor

www.prbcoals.com 24

COAL USERS’ GROUP

Capacity

Factor, %

60 70 80

Case

Study

Boiler

Type

1 Opposed

Wall

Savings, $k 8,295 9,096 10,925

Breakeven, Months 20 18 15

2 Tangential Savings, $k 7,973 9,301 10,630

Breakeven, Months 18 15 13

3 Cyclone Savings, $k 2,861 3.331 3,815

Breakeven, Months 23 20 18

www.prbcoals.com 25

COAL USERS’ GROUP

Redoing Case Studies for Eastern Coal

Price of eastern coal has increased

Market Size - approximate

Opposed Wall – 226

Tangential – 143

Cyclone - 15Next steps

Presentations, feedback

www.prbcoals.com 26

COAL USERS’ GROUP

CO2 Emissions

Pulverized coal units (Case Studies 1 and 2)

0.34% Improvement in Boiler Efficiency

6.5 lb CO2 /MW or 11,380 t CO2 /y

Cyclone units (Case Study 3)

About half of pulverized coal units

Investigate other potential way of reducing CO2 Emissions not

only for 30 – 45 year old units but also 0-25 year old units

www.prbcoals.com 27

COAL USERS’ GROUP

This Research Subcommittee came together with concerns by

some that this effort could not be done, but with some

considerable give and take the Subcommittee succeeded. Most

were surprised by the short breakevens or short payback

periods. The costs and savings were revisited and largely

remain unchanged. Clearly the Dynamic Classifier and Neutral

Network upgrades provided some amazing savings.

The Subcommittee is to be applauded for its enthusiastic

efforts over a 20-month effort in monthly one-hour conference

calls. Bob Sommerlad, its Chair, says it was an honor and

pleasure to work with them.

www.prbcoals.com 28

www.prbcoals.com 29

COAL USERS’ GROUPwww.prbcoals.com 30

COAL USERS’ GROUP

Harm

What do you do on a regular basis to prevent injuries or illnesses?

Fire

What do you do on a regular basis to prevent fires?

Dust

What do you do on a regular basis to control dust?

31www.prbcoals.com

COAL USERS’ GROUP

• Fire and Explosion Risk

• Carbon Monoxide

• Respirable Dust

• Inorganic Arsenic

• Machine (Conveyor Guarding)

• Particulate Matter (PM)

• Fugitive Dust

32www.prbcoals.com

COAL USERS’ GROUP

Powerton Power Plant

33

What ya doing to prevent this?

www.prbcoals.com

www.prbcoals.com 34