Part Description QTY
A Spillway 1
B 3/4 in., 1in. ID tubing Adapter 1
C Gasket 1
D Diverter 1
Information about these operating instructionsWelcome to OASE Living Water. You made a great choice with the purchase of this product Waterfall Spillway 8 in. Prior to operating the unit, please read the instructions of use carefully and fully familiarize yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions. Please strictly follow the enclosed instructions to ensure safe and correct handling of the product. Keep these instructions in a safe place. Please also hand over the instructions when passing the unit on to a new owner.
B.A.C.D.
Questions, problems, missing parts? Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at [email protected]. Or visit our website at www.oase-livingwater.com
- English -
32
WARNINGS AND CAUTIONS SYMBOLSSymbols used in these instructionsThe symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage.This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.
Risk of personal injury caused by a general source of danger.This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate measures are not taken.
Important information for trouble-free operation.
!
Intended useWaterfall Spillway 8 in., referred to in the following as “unit”, may only be used as specified in the following:• Operation under observance of the technical data. The following restrictions apply to the unit:• Do not use in swimming pools or hot tubs.• Never use the unit to convey fluids other than water.• Never run the unit without water.• Do not use for commercial or industrial purposes.• Do not use in conjunction with chemicals, food products, easily flammable or explosive substances.• Do not connect to the domestic water supply.
Use other than that intendedThis unit can be dangerous and cause harm if not used in accordance with these instructions. Any use not in accordance with these instructions or modification(s) to the unit will void the limited warranty.
4
- English -
Installation1. For maximum water flow, it is recommended that the
largest tubing size for your pump is used. ○ If needed, cut the adapter as shown using a hacksaw;
consult packaging for tubing size.
2. Assemble the Diverter, Gasket, and Adapter
1.
3. Select a level location to place the waterfall spillway. ○ Begin by building a base with the desired waterfall
height.
4. Place the spillway onto the base. NOTE: It is very important that the spillway is level, so be sure to check that the structure is level from front to back as well as left to right.
5. Connect tubing to the outlet adapter. Connect the other side of the tubing to the pump. Place the pump in the pond.NOTE: Tubing and pump are not included.
6. Continue building the rest of the structure. Carefully cover the waterfall spillway and tubing with natural material for a professional look.NOTE: Design the structure to fit the tubing through the back without any kinks.
3.
2.
5.
4.
6.
Questions, problems, missing parts? Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at [email protected]. Or visit our website at www.oase-livingwater.com
- English -
54
Maintenance and cleaning
Attention! Dangerous electrical voltage.Possible consequences: Death or severe injury.Protective measures: Prior to reaching into the water, disconnect the power supply to all units used in the water.
Disconnect the power plug prior to carrying out work on the unit.
● Before cleaning, always disconnect the pump from the power source.
● At least once a year the entire system should be disassembled and cleaned thoroughly using warm, soapy water (mild detergent).
1.
Start-up
Important:
● This waterfall spillway is designed to work with a pump. PUMP NOT INCLUDED. The pump switches on automatically when power connection is established.
1. Switching on the pump: Connect power plug to the socket.○ After the pump has been connected the waterfall spillway
will start to fill up and then create waterfall
2. Switching off the pump: Disconnect the power plug.
DisposalDo not dispose of this unit with domestic waste! The spillway is ABS plastic. Further information about the recycling of this product can be obtained from your local municipal authority.
Issue Cause Solution
The unit is not performing
Pump power supply not connected
Connect pump power supply
Inappropriate pump size Check box for proper pump size
Insufficient flow Spillway blocked Check outlet on spillway for blockage
Tubing blocked Clean or replace tubing
Tubing kinked Eliminate kink, replace tubing if it is damaged
Excessive flow loss in the tubing due to friction
Reduce tubing length to reduce frictional loss
Pump is clogged Check and clean pump
Troubleshooting
● The basic rule of thumb is that you need 100 GPH of flow for every 1 in. of width for your waterfall.○ Example: if you have an 8 in. wide waterfall and the waterfall is at a height of 5 ft., then you need a pump to
be able to deliver 800 GPH at 5 ft.● If you prefer a more subtle flow of water, cut the flow rate in half, making 50 GPH your target for every 1 in. of
waterfall width.● If you prefer a more robust flow of water, double the flow rate, making 200 GPH your target for every 1 in. of
waterfall width.● Don’t forget to take friction loss into account when selecting the pump. For this reason it is recommended to
use a dedicated pump that is plumbed directly to the waterfall and a separate pump for filters and water features.
- English -
6
Spillway width
Model no. Inlet size Spillway dimensions Target flow rate
for a subtle flowTarget flow rate for a
moderate flowTarget flow rate for a robust flow
8 in. 45388 3/4, 1 in. 12.5 x 10.4 x 6 in. 400 GPH 800 GPH 1600 GPH
Pos.
Waterfall Spillway
8 in.
1 Spillway
2 Diverter
3 Gasket
4 Adapter
Wat
erfa
ll Sp
illw
ay
1
24
3
RAPPELAPPELEZ LE 1-866-627-3435
AVANT DE RETOURNER AU MAGASIN.
Aliviadero ancho
No. de modelo
Tamaño de entrada Dimensiones Tasa de flujo meta
para un flujo sutilTasa de flujo meta para
un flujo moderadoTasa de flujo meta para
un flujo fuerte
203 mm 45388 19 / 25 mm 368 x 262 x 152 mm 1514 LPH 3028 LPH 6057 LPH
OASE North America INC. · www.oase-livingwater.com 4870
6/09