water industry wis 4-02-06 specification january 2019: …€¦ · wis 4-02-06 january 2019: issue...

30
WATER INDUSTRY SPECIFICATION Fine to Flush: WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117.

Upload: others

Post on 12-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

WATER INDUSTRY

SPECIFICATION

Fine to Flush:

WIS 4-02-06 January 2019: Issue 1

(Page 1 of 30)

1 Water Industry Act 1991: Section 117.

Page 2: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

2

Page 3: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

3

confirm that the product

material does not contain petro chemical derived plastic fibres. The test will

French Standard

Page 4: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

4

2 A 4.5 litre flush volume toilet has been selected because it:

• Is considered representative of the most commonly used units now being installed in the UK.

3 The WC Bowl Clearance Test may be carried out in conjunction with the Drainline Clearance Test, in which case it shall be connected to a drainline as specified in Appendix B.

Page 5: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

5

Page 6: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

6

4

Page 7: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

7

Page 8: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

8

Page 9: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

9

Page 10: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

10

Page 11: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

11

Page 12: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

12

Page 13: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

13

1005.12

1%

samplecontrolofmassdry

sievemmonretainedmassdrythroughpassedproductofMass

5 This is to encourage the sample material to turn over during the rinsing and, in doing so, exposing any loose fibres to the flow of water. 6

45o

300 mm

Sieve with 12.5 mm round holes

Page 14: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

14

Page 15: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

15

Page 16: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

16

Page 17: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

17

Page 18: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

18

Page 19: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

19

7 Number of flushes for a single person household per day. Compendium of micro-component statistics. WRc Report Ref: P9193.03: 2012.

Page 20: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

20

Page 21: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

21

Page 22: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

22

8 Whilst it is accepted that the transport time for a product to progress from a WC flush to treatment works inlet will vary considerably, a time of six hours has been chosen for the test as representative the average time of transit from a property to a wastewater treatment facility. 9 This procedure ensures loose fibres are disengaged from the larger fragments.

Page 23: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

23

from all eight one litre sub samples

Page 24: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

24

Page 25: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

25

Page 26: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

26

10 When the tap water is much colder than the laboratory temperature, bubbles can form over the 24 hour test period as the water warms. In this situation, it is highly recommended that the temperature of water in the column and air temperature in the laboratory be allowed to come into equilibrium over 24 hours before starting a test.

2.0

m

Upper timing line

Lower timing line

Floatation line

Drain valve

200mm diameter transparent pipe

Drain valve

0.1 m

0.3 m

1.2 m

Page 27: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

27

or below the 300 mm

marker line

Page 28: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

28

Page 29: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

Water UK 2019

29

11

Page 30: WATER INDUSTRY WIS 4-02-06 SPECIFICATION January 2019: …€¦ · WIS 4-02-06 January 2019: Issue 1 (Page 1 of 30) 1 Water Industry Act 1991: Section 117. 2 Water UK 2019 3 confirm

30