The Problem Page 3 The Solution Page 4 Benefits of Off-The-Floor Water Closet Supports Page 5 Water Closet Support Features Page 6 Water Closet Overview Page 7 Water Closet Support Battery Prefabrication Page 8 Optional Accessories Page 9-10 How to Select a Water Closet Page 11 Suggested Specifications Page 12 Applications Page 13 Certifications/Listings Page 14 Summary Page 15 Questions Page 16

Page 3: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

3

Public Restrooms can present a source of problems and extra expense to maintain and keep clean. Architects and engineers are concerned with controlling building costs and ensuring structurally sound designs by selecting proper water closet supports. Contractors are looking for products that allow them to save time and reduce installation costs during construction. Customers insist on the best value for their investment and expect a high level of sanitation.

Page 4: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

4

Off-The-Floor water closet supports for various installation applications.

Labor saving water closet supports for battery prefabrication.

Application versatility for metal stud, block or narrow wall chase configurations.

Reduced maintenance and cleaning costs.

Page 5: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

5

Fixture supports available for Off-The-Floor water closets. Off-The-Floor water closet systems can be installed more economically than conventional floor mounted systems. Less Sleeving. In most cases only one sleeve is required to take care of the vertical inlet fitting at the start of the horizontal run. Since all the roughing is done on the floor and not in the ceiling below, no scaffolding, ladders or similar supports are required. The installer works on the floor and not in the ceiling below; time is saved since working conditions are more favorable. Because all the rough-in piping is on the floor above, “dropped ceilings” are not required; ceiling space is saved. This enables building ceiling height to be lower, effectively saving overall construction costs.

Page 6: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

6

Typical Smith Fixture Support with Waste FittingLINEBACKER®

Figure 0210RY Horizontal No-Hub Right Hand Single Fitting

Face Plate GasketFace Plate Bolts &

Washers

4” Connection (NO-HUB)

Waste Fitting with 2” NO-HUB Offset

Vent

Face Plate Nuts

Fixture Studs

Face Plate

Base SupportsBase Support Bolts and Washers

ABS Nipple

ABS Adjust-To-Wall Coupling with Knockout

Test CapOutlet Gasket

Fixture Bearing Nuts & Washers

Fixture Cap Nuts

Rear Support lug __ –M51 Anchor Foot(regularlyfurnished)

Fixture Washers-Fiber

Page 7: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

7

9” (230)

7 ½” (190)

4 ¼” (110) Min9” (230) Max

Cut Off Tab

18 ¼” (465)

Front View

4” (100)

• Adjustable horizontal and vertical fitting supports to fit various installation requirements.

Figure 0210, 0220

• Wide range of applications from metal stud to block walls.

• Water closet supports designed to fit in wall chase from 12” to 18”.

• Available with no-hub connection.

Page 8: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

8

-M54 Side Mounted Leg Symmetric construction Increased load bearing capability One bolt per leg allowing faster and easier prefabrication

-M54-M58 Faceplate with “O” Ring Seal Integral adjustable wall coupling,

nipple and test cap Adjustment at the faceplate rather than at the rear of the water closet (coupling) 10 inch-long nipple covers various installations Enhanced sealing with an o-ring at the faceplate

0200 Water Closet Support series time and labor saving features allow for easy battery prefabrication.

½ “ incremental markings for quick rough-in

Page 9: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

9

Suffix –M13 Tiling Frame – The purpose of this frame is to provide a rim for a flat even surface for the tiler to work to when he is applying the finished wall tile. Available for siphon jet closets only.

Suffix –M12 Exposed Flush Valve Supply Support – The M12 support has been redesigned to provide greater strength and ease of installation. The stronger (3/16”) angle clip and more rigid stud make the M12 a great alternative to competitive products like the HoldRite Support.

Suffix –M50 Elevated Support Base – For double (back-to-back) installations which require a single elevated water closet, the –M50 variation may be used with all regular Smith adjustable or compact supports. The –M50 is particularly adaptable to hospital or nursing home applications where a single water closet is installed on the stack at each floor. Not recommended for battery installations.

Suffix –M40 Water Closet Support For Wide Pipe Chase - When the “C” dimension exceeds 7”, the –M40 Wide Pipe Chase Support should be used. This accessory provides a set of feet directly behind the wall for extra rigidity and an alignment yoke to ensure proper alignment of the nipple. The M-40 may be used with any vertical or horizontal fixture support in single or double (back-to-back) installations.

Specify “C” dimensions when ordering

C

Page 10: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

10

Suffix –M54 Face Plate with side Mounted Base Support Assembly –

Front View Top View

A concealed flush valve will not clear the face plate when used with a blowout water closet support. Therefore 4 ½” to 6 ½” is required from back of wall to face plate to permit the installation of the concealed flush valve piping.

Suffix –M17 Water Closet Setting Gauge – The Gauge has the same dimensions as the rear of the “Off The Floor” siphon jet bowl and is designed to eliminate costly trial and error test mounting and reduce the number of bowl “lifts” per day.

Concealed Flush Valves – For most siphon jet water closets with concealed flush valves, the supply pipe enters the rear of the water closet above the top of the face plate without interference. Concealed flush valve piping in all cases does not interfere with the vent connection of the fitting.

Siphon Jet

Blowout

4 ½” – 6 ½”

Page 11: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

11

Piping For Floor Mounted Fixtures

Piping for Off-The- Floor Fixtures

Determine if the Fixture will be Floor Mounted or Off-the-Floor.

Determine if a Siphon Jet or Blowout Water Closet is best for the application.

Review the Battery Installation.

Select Vertical Fitting with Side Inlets.

Left Hand Right Hand

Vent Stack

Determine Left or Right Hand Horizontal Fittings

Select the Face Plate.

Page 12: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

12

•Wall Hung Siphon Jet Water Closet Supports – Smith No. 0200 series adjustable shallow rough-in support for one-pour floor construction. Where two-pour construction is required, Smith No. 0100 series adjustable deep rough-in support may be used. Where furred wall space is not sufficient for the adjustable series, Smith “compact” No. 0400 series may be used.

•Wall Hung Blowout Water Closet Supports – Smith No. 0300 series “adjustable” rough-in support. Where furred wall space is not sufficient for the adjustable series, Smith “compact” No. 0400 series may be used.

•Wall Hung Residential Water Closet Supports Floor-Mount Type – Smith No. 0550F series siphon jet supports with waste fitting and extra heavy cast iron face plate. Combined face plate and closet support shall be securely bolted to floor construction. When back-to-back bowls are specified, use No. 0550FD series.

•Wall Hung Residential Water Closet Supports Stud-Mount Type – Smith No. 0550 series stud-mount siphon jet support with waste fitting and adjustable steel face plate with steel reinforcing strap of design which transmits all top fixture stud-bolt loading to interior wall construction and bottom fixture stud-bolt loading to sole plate. When back-to-back bowls are specified, use No. 0550D series.

•Floor Mounted Back Outlet Water Closet Fittings – Smith No. 0200 or 300 adjustable series fixture supports with type No. 2 outlet connection. Where furred wall space is not sufficient for the adjustable series, Smith “compact” No. 0400 series or Smith No. 0670 thru 0680 waste fitting assembly with Type No. 2 closet outlet connection may be used.

Page 13: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

13

Water closet supports for various installationsHorizontal Adjustable Carriers

Double/Metal stud wall Single/Metal stud wall Double/Block wall Single/Block wall

Vertical Adjustable Carriers

Double/Metal stud wall Single/Metal stud wall Double/Block wall Single/Block wall

Vertical Fixed Carriers

Double/Metal stud wall Single/Metal stud wall Double/Block wall Single/Block wall

Page 14: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

14

IAPMO Listed – File #1618

Conforms to ASME – A112.6.1M

Page 15: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

15

Off-The-Floor Water Closet Supports save time and reduce installation costs.

Off-The-Floor Horizontal Water Closet Supports provide installation versatility for battery prefabrication.

Off-The-Floor fixtures reduce maintenance and cleaning costs while improving toilet room sanitary conditions.

Fixture supports available for all major Off-The-Floor Water Closet models/manufacturers. Adjustable horizontal and vertical fitting supports to fit various installation requirements.

Wide range of applications from metal stud to block wall to narrow wall chase.

Page 16: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co
Page 17: Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co

For more information on this or other products, or to contact your local Jay R. Smith Mfg. Co. representative, please visit our website at www.jrsmith.com