wall mounted split systems g series - contekcontek.com.tr/upload/1277984645.pdf · cross-section of...
TRANSCRIPT
WALL MOUNTEDSPLIT SYSTEMS
G SERIES
• Negative Ion Generator (Standard)The Ion Generator releases negative ion shower to create a refreshing and clean environment as if you are fallen into the world of nature.
F E A T U R E S
AIR PURIFYING SYSTEM
Pre Filter
NanoSilver -bacteria & germselimination
NanoPhotocatalyst -deVOCs & deodorization(150 times stronger than highperformance activated carbon)
- Effectively Inactivate & Eliminate Various Harmful Airborne Elements 99.9% bacteria free, no more worries
• AWM-G Series Offers Various Indoor Air Quality Features Improved with NanoTechnology That Redefines 21st Century Living Environment
• AWM-G Series Offers Various Indoor Air Quality Features Improved with NanoTechnology That Redefines 21st Century Living Environment
Acson is focused on developing new and exciting products to improve everyday living environment of the 21st century. The all-new NanoShield combines powerful sterilizing and deodorizing effect of NanoSilver and nano-Photocatalyst.
Silver is used from the days of Hippocrates (Father of Medicine) as a healing agent and its use has been expanded into anti-bacterial applications ever since. Modern nanotechnology provides through full - infusion onto the filters and larger coated surface area, with this sterilization, deodorizing power is 150 times stronger whereas filtration effectiveness is improved 20 times.
• Triple Action
OxygenEnrichmentMembrane
OxygenEnriched AirNormal air
Oxygen Enrichment Module
• O2 Therapy (Premium Series)A specially designed oxygen enrichment module, will allow O2 to penetrate through its membranes at faster rate compared to N2, which result in increase of O2 in air. The O2 enriched air provides a fresh living environment in your house or office.
Frame
Cross-section of module
FrameOxygen
EnrichmentMembrane
OxygenEnriched Air
Normal air
N2N2
N2N2
N2N2
N2N2 N2N2N2N2
N2N2 N2N2O2O2
O2O2
O2O2
N2N2
N2N2
N2N2
N2N2
N2N2N2N2N2N2
O2O2
O2O2
Oxygen EnrichmentMembrane
O2: 21%
N2: 79%
O2: 21%
N2: 79% N2: 70%
O2: 30%
N2: 70%
O2: 30%
VacuumPump
O2 Pump– pump the O2
enriched air to indoor
OxygenEnrichmentModule
* Please refer to your local agent/dealer for product with this specification.
Available for A(5)WM10 & 15G only.
+Oxygen Plasma Osmongens -
Organically Odours (Gases)
Non-Harmful GasIrreversible Process
+Oxygen Plasma Micro-Organism
Inactive/non-harmful microbes
+Oxygen Plasma Oxygen Molecules
Small Ions
Mean Ions
Large Ions
Capture Dust And Particles
High-energy oxygen plasma combines easily with most harmful gases to neutralize, and render them harmless to human beings. For example, NTP Air Sterilizer can lower the concentration of carbon monoxide (CO) that causes fatigue, headaches, etc. When oxygen plasmas neutralize CO, carbon dioxide is produced. This process is irreversible. Thus effectively reducing the amount of CO molecules in the indoor environment.
N eutralizes Harm ful G ases
NTP Air Sterilizer disrupts the basic biological process of microbes. Oxygen plasmas simply combines with the cell structure to negatively affect the growth and activity of certain harmful microbes and germs. This will reduce the amount of harmful entities in the air, easily creating healthier air.
Inhibits G row th Of Harm ful G erm s & M icrobes Nascent oxygen plasmas combine with other
oxygen molecules to form ions (charged particles), including small ions, mean ions, and large ions. These attract dust particles easily and tend to sink to the ground faster than normal dust particles. This helps to reduce health-problems caused by dusty environment.
R em oves Dust
• New Outdoor Condensing UnitThe new condensing unit (C series) is using the aluminium slit fin, which can greatly increase the heat transfer efficiency and boost up the unit capacity effectively. The valve cover design enables the condensed water to be carried into base pan instead of dripping onto the floor.
• With R410A Refrigerant• Not harmful to the Earth's ozone layer with Ozone Depletion Potential = 0.• Higher volumetric capacity and increased EER & COP compared to R22 and R407C.
> Aluminium Slit Fin
• Network Interface Module - Telephone Control (NIM-Tele)By just making up a call, user can control the operation of the air conditioner remotely at anytime and anywhere. This innovative technology not only provides on/off control but also operating mode control, temperature control and status monitoring availability. The password protection function ensures more safety operation to the system.
HH
FF
FF
HHCC
50% R32 50% R125
FF
FF
FF
FFFF
CC CCHH
(R410A)
NIM-TELEMODULE
New Aesthetically Outlook A smooth front panel makes the cleaning process much easier for the user. These units blended easily into any interior decoration and design. The centrally located LED light makes it easier for user to check the operating conditions.
• Easy ServiceabilityWall Mounted G series comes with a new design of air discharge housing whereby the fan blower can be easily accessed by just loosing up two screws on the unit. This new feature provides a flexible, faster and easier way to clean up the fan blower and ionizer.
Double Louver This new louver design together with its automatic air swing function fully optimizes the room comfort by distributing the air evenly to every corner of the room.
• Enhance Skew Fan DesignThe unique skew fan design provides an improved sound quality while its larger diameter creates better air flow to the operating environment.
• High Performance With COP >3.5According to criteriaof European Unionregulation. The efficient Acson new air conditioner, model A5WM07GR and A5WM10GR hasachieved the highestenergy rating of A, in ascale of A to G, based on the Energy Rating Efficiency Ratio (EER).
A5LC10CR
A
433
GF
ED
CB
A
Less efficient
Energy
Norm EN 814Air conditioner Energy Label Directive YY/XX/EC
Manufacturer
Outside Unit
Air Conditioner
Energy Efficiency Ratio Full load (the higher the better)
More efficient
(dB(A) re 1 pW)Noise
Inside Unit A5WM10GR
Annual Energy Consumption,kWh in cooling mode
Cooling output kW
Heat output kW
Heating PerformanceA: higher G: lower
2.8
2.8A B C D E F G
3.2
Further information is containedin product brochures
(Actual consumption will dependon how the appliance is usedand climate)
Type Cooling only
Cooling + Heating
Air cooled
Water cooled
3-Fold Heat Exchanger The compact design of this 3-fold structure providesa large surfacearea for better &efficient heatexchange.
• EASY-To-Use LCD Remote Controller
IonizerJust press the ionizer button and the air-conditioner will generates negative ion, which will refresh the indoor air effectively.
Turbo ModeTURBO function is available in COOL, HEAT and DRY modes only. Once turbo mode is activated, the air-conditioner will run into full power with indoor fan running at HIGH speed for 20 minutes. This enables the required set temperature to be achieved in a short time. If TURBO and SLEEP are activated at the same time, the SLEEP mode timer will be reset, it will resume after TURBO function is cleared.
Personalized SettingIt allows user to pre-set and store 2 groups of personal settings (included timer setting) in the handset. This personalized settings can be overwrite from time to time based on user requirements.
Sleep Mode Auto ControlSetting of Sleep mode will gradually increase or decrease the setting temperature to provide a comfortable surrounding for sleeping. It is also acts as an energy saving mode.
Auto Random RestartWhen there is power failure occurred during operation, the unit will automatically restart as the last setting condition once the power is resumed. Option is provided to cancel this feature.
Auto Restart System
Operation Stop Restart
E2 PROM
Setting stored before power failure.
Power Failure Power Returns
Temperature ˚C
20min 30min
TURBO MODE CONVENTIONAL
HEATING
0 11/2
-1ºc
-2ºc-3ºc
2
Sleep Set On
Te
mp
era
ture
Hours
Heating
COOLING
0 11/2
+0.5˚c
+0.5˚c+1ºc
2Sleep Set On
Te
mp
era
ture
Hours
Cooling
“On/Off” Button
Fan Speed SelectionOperation Mode
OFF Timer Setting
Personalized Setting
Automatic Air Swing
Temperature Setting
Turbo Mode Setting
Sleep Mode Setting
On Timer Setting
Ionizer
S P E C I F I CAT I O N S [R22 Models]
SPECIFICATIONS [R22-60HZ]
AWM09GR AWM10GR AWM15GR AWM20GR AWM20GR AWM25GRALC09CR ALC10CR ALC15CR ALC18CR ALC20CR ALC25CR
W 2640 2780 3520 5275 5570 6890Btu/h 9000 9500 12000 18000 19000 23500
W 2640 2780 3520 5420 5715 7035Btu/h 9000 9500 12000 18500 19500 24000
V/Ph/HzCOOLING W 910 835 1100 1760 1780 2600HEATING W 750 755 980 1810 1830 2540COOLING A 4.0 3.8 5.0 7.6 8.0 12.6HEATING A 3.4 3.4 4.5 7.5 8.1 12.5
AWM09G AWM10G AWM15G AWM20G AWM20G AWM25GALC09C ALC10C ALC15C ALC18C ALC20C ALC25C
W 2640 2780 3,520 5275 5570 6890Btu/h 9000 9500 12,000 18000 19000 23500
V/Ph/HzW 880 836 1,100 1770 1790 2620A 3.9 3.7 4.9 7.9 8.3 12.8
cfm / L/s 275 / 130 300 / 142 345 / 163 650 / 307SOUND LEVEL - H / M / L dB(A) 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29 49 / 44 / 42
HEIGHT mm/in 260 / 10.2WIDTH mm/in 799 / 31.4DEPTH mm/in 198 / 7.8
WEIGHT kg 10
SOUND PRESSURE LEVEL dB(A) 45 46 49 50 50 52HEIGHT mm/in 495/19.5 753 / 29.6WIDTH mm/in 600/23.6 855 / 33.7DEPTH mm/in 245/9.7 328 / 12.1
WEIGHT (kg) 28 58
LIQUID mm/inGAS mm/in 12.7 / 1/2
15
FLARE VALVE
RUNNING CURRENT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
INPUT POWER
198 / 7.8
700/27.6250/9.8
32
306 / 12.0260 / 10.2899 / 35.4
INPUT POWER
1062 / 41.8
RUNNING CURRENT
AIR FLOW FAN TYPE
510 / 241
PIPE SIZE15.88 / 5/8
6.35 / 1/49.52 / 3/8
OUTD
OOR
UN
ITPI
PE
651 / 25.6DIMENSION 855 / 33.7
328 / 12.157
TYPE
540/21.3
REFRIGERANT TYPEREFRIGERANT CONTROL
ROTARY HERMETICR22
CAPILLARY TUBE
AIR FILTRATION
COMPRESSOR TYPE
NANOSILVER-COATED ANTI-BACTERIAL SARANET FILTERNANOPHOTOCATALYST-COATED DEODORIZING SARANET FILTER
NEGATIVE ION GENERATORNON-THERMAL PLASMA (NTP) AIR STERILIZER
HEAT PUMP
INDO
OR U
NIT
DIMENSION
44 / 40 / 36
222 / 8.7
AIR TREATMENT DEVICES
INDOOR UNITOUTDOOR UNIT
ANTI-FUNGUS SKEW FAN
12
POWER SOURCE
POWER SOURCE
220 -240 / 1 / 50
INDOOR UNIT
OUTDOOR UNIT
220 -240 / 1 / 50
COOLING ONLY
NOMINAL COOLING CAPACITY
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151: 1994(E) 3) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW : COOLING : 27°C DB / 19°C WB INDOOR AND 35°C DB OUTDOOR4) ALLOWABLE OPERATING RANGE: COOLING : 19.4°C DB / 13.9°C WB INDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB INDOOR AND 46.1°C DB OUTDOOR5) ALC18CR AVAILABLE FROM APRIL '06 ONWARDS
AWM10GR AWM15GR AWM20GR AWM25GRALC10BR ALC15BR ALC20BR ALC25BR
W 2700 3370 5570 6450Btu/h 9200 11500 19000 22000
W 2700 3520 5570 6890Btu/h 9500 12000 19000 23500
V/Ph/HzCOOLING W 827 1221 1905 2415HEATING W 747 1051 1773 2285COOLING A 3.8 5.4 8.4 10.7HEATING A 3.4 4.6 7.9 10.1
AWM10G AWM15G AWM20G AWM25GALC10B ALC15B ALC20B ALC25B
W 2700 3370 5570 6450Btu/h 9200 11500 19000 22000
V/Ph/HzW 827 1221 1905 2415A 3.8 5.4 8.4 10.7
cfm / L/s 300 / 142 345 / 163 510 / 241 650 / 307SOUND LEVEL - H / M / L dB(A) 39 / 34 / 28 42 / 36 / 29 44 / 40 /36 49 / 44 / 42
HEIGHT mm/inWIDTH mm/inDEPTH mm/in
WEIGHT kg
SOUND PRESSURE LEVEL dB(A) 48 49 52 53HEIGHT mm/inWIDTH mm/inDEPTH mm/in
WEIGHT 31 34 57 58
LIQUID mm/in 9.52 / 3/8GAS mm/in 9.52 / 3/8 12.7 / 1/2
FLARE VALVE
RUNNING CURRENT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
INPUT POWER
12
494 / 19.4740 / 29.1
15
270 / 10.6 330 / 13.0
NANOSILVER-COATED ANTI-BACTERIAL SARANET FILTERNANOPHOTOCATALYST-COATED DEODORIZING SARANET FILTER
NEGATIVE ION GENERATORNON-THERMAL PLASMA (NTP) AIR STERILIZER
198 / 7.81062 / 41.8
646 / 25.4840 / 33.1
FAN TYPE
PIPE SIZE15.88 / 5/8
ROTARY HERMETICR22
CAPILLARY TUBE
306 / 12.0
6.35 / 1/4
260 / 10.2899 / 35.4
INPUT POWER
OUTD
OOR
UN
IT
PIPE
DIMENSION
TYPE
REFRIGERANT TYPEREFRIGERANT CONTROL
COMPRESSOR TYPE
RUNNING CURRENT
AIR FLOW
HEAT PUMP
INDO
OR U
NIT
DIMENSION222 / 8.7
AIR TREATMENT DEVICES
INDOOR UNITOUTDOOR UNIT
ANTI-FUNGUS SKEW FAN
AIR FILTRATION
POWER SOURCE
POWER SOURCE
208 - 230 / 1 / 60
INDOOR UNITOUTDOOR UNIT
208 - 230 / 1 / 60
COOLING ONLY
NOMINAL COOLING CAPACITY
kg
1)ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2)NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW : COOLING : 27°C DB / 19°C WB INDOOR AND 35°C DB OUTDOOR 3)ALLOWABLE OPERATING RANGE: COOLING : 19.4°C DB / 13.9°C WB INDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB INDOOR AND 46.1°C DB OUTDOOR
S P E C I F I C A T I O N S [R410A]
S P E C I F I C A T I O N S [R407C]
AP - AWM - G - 06A www.acson-international.com
1) ALL SPECI FI CATI ONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WI THOUT PRI OR NOTI CE. 2) ALL UNI TS ARE BEI NG TESTED AND COMPLY TO I SO 5151: 1994(E) 3) NOMI NAL COOLI NG CAPACI TY I S BASED ON THE CONDI TI ONS BELOW : COOLI NG : 27°C DB / 19°C WB I NDOOR AND 35°C DB OUTDOOR
4) ALLOWABLE OPERATI NG RANGE: COOLI NG : 19.4°C DB / 13.9°C WB I NDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB I NDOOR AND 46.1°C DB OUTDOOR
AWM07GR AWM10GR AWM15GR AWM20GR AWM25GR
A4LC07BR A4LC10BR A4LC15BR A4LC20BR A4LC25BRW 2230 2640 3225 5130 6010
Btu/h 7600 9000 11000 17500 20500W 2170 2785 3665 5570 7035
Btu/h 7400 9500 12500 19000 24000V/Ph/Hz
COOLI NG W 795 975 1440 2185 2775HEATI NG W 750 825 1290 2280 2750COOLI NG A 3.4 4.3 6.6 10.3 13.5HEATI NG A 3.2 3.6 6.1 10.9 13.4
AWM07G AWM10G AWM15G AWM20G AWM25G
A4LC07B A4LC10B A4LC15B A4LC20B A4LC25BW 2170 2640 3225 5365 6155
Btu/h 7400 9000 11000 18300 21000V/Ph/Hz
W 855 975 1440 2295 2860A 3.6 4.3 6.6 10.7 13.4
cfm / L/s 275 / 130 300 / 142 345 / 163 510 / 241 650 / 307SOUND LEVEL - H / M / L dB(A) 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29 44 / 40 /36 49 / 44 / 42
HEI GHT mm/in 260 / 10.2WI DTH mm/in 799 / 31.4DEPTH mm/in 198 / 7.8
WEI GHT kg 10
SOUND PRESSURE LEVEL dB(A) 47 48 49 52 53
HEI GHT mm/in
WI DTH mm/in
DEPTH mm/in
WEI GHT (kg) 28 31 34 57 58
LI QUI D mm/in 9.52 / 3/8
GAS mm/in 12.7 / 1/2
POWER SOURCE
220 -240 / 1 / 50
I NDOOR UNI T
OUTDOOR UNI T
220 -240 / 1 / 50
COOLI NG ONLY
NOMI NAL COOLI NG CAPACI TY
HEAT PUMP
IND
OO
R U
NIT
DI MENSI ON222 / 8.7
AI R TREATMENT DEVI CES
I NDOOR UNI T
OUTDOOR UNI T
ANTI -FUNGUS SKEW FAN
AI R FI LTRATI ON
POWER SOURCE
I NPUT POWER
OU
TDO
OR
UN
IT
PIPE
PROTECTI ON DEVI CE
DI MENSI ON
TYPE
REFRI GERANT TYPE
REFRI GERANT CONTROL
COMPRESSOR TYPE
RUNNI NG CURRENT
AI R FLOW FAN TYPE
6.35 / 1/4PI PE SI ZE
15.88 / 5/89.52 / 3/8
ROTARY HERMETI C
R407C
CAPI LLARY TUBE
306 / 12.0260 / 10.2899 / 35.4198 / 7.8
1062 / 41.8
15
270 / 10.6
646 / 25.4
840 / 33.1
330 / 13.0
NANOSI LVER-COATED ANTI -BACTERI AL SARANET FI LTER
NANOPHOTOCATALYST-COATED DEODORI ZI NG SARANET FI LTER
NEGATI VE I ON GENERATOR
NON-THERMAL PLASMA (NTP) AI R STERI LI ZER
FLARE VALVE
RUNNI NG CURRENT
NOMI NAL COOLI NG CAPACI TY
NOMI NAL HEATI NG CAPACI TY
I NPUT POWER
12
EXTERNAL OVERLOAD PROTECTOR BUI LT-I N OVERLOAD PROTECTOR
494 / 19.4
740 / 29.1
1) ALL SPECI FI CATI ONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WI THOUT PRI OR NOTI CE. 2) ALL UNI TS ARE BEI NG TESTED AND COMPLY TO I SO 5151: 1994(E) 3) NOMI NAL COOLI NG CAPACI TY I S BASED ON THE CONDI TI ONS BELOW : COOLI NG : 27°C DB / 19°C WB I NDOOR AND 35°C DB OUTDOOR
4) ALLOWABLE OPERATI NG RANGE: COOLI NG : 19.4°C DB / 13.9°C WB I NDOOR AND 19.4°C DB OUTDOOR TO 26.7°C DB / 19.4°C WB I NDOOR AND 46.1°C DB OUTDOOR
A5WM07GR A5WM09GR A5WM10GR A5WM15GR A5WM20GR A5WM25GR
A5LC07CR A5LC10CR A5LC10CR A5LC15CR A5LC20CR A5LC25CRW 2200 2640 2780 3520 5275 6155
Btu/h 7500 9000 9500 12000 18000 21000W 2200 2640 2780 3520 5275 6450
Btu/h 7500 9000 9500 12000 18000 22000V/Ph/Hz
COOLI NG W 680 865 865 1200 1640 1900HEATI NG W 550 745 745 1080 1550 1850COOLI NG A 3.1 3.9 3.9 5.4 6.8 8.3HEATI NG A 2.6 3.4 3.4 4.9 6.6 8.3
A5WM07G A5WM09G A5WM10G A5WM15G A5WM20G A5WM25G
A5LC07C A5LC10C A5LC10C A5LC15C A5LC20C A5LC25CW 2200 2640 2780 3520 5275 6155
Btu/h 7500 9000 9500 12000 18000 21000V/Ph/Hz
W 620 865 865 1230 1630 1890A 2.9 3.9 3.9 5.5 6.8 8.3
cfm / L/s 300 / 142 345 / 163 510 / 241 650 / 307SOUND LEVEL - H / M / L dB(A) 39 / 34 / 28 42 / 36 / 29 44 / 40 /36 49 / 44 / 42
HEI GHT mm/inWI DTH mm/inDEPTH mm/in
WEI GHT kg
SOUND PRESSURE LEVEL dB(A) 44 49 52 53HEI GHT mm/in 495 / 19.5 651 / 25.6 753 / 29.6WI DTH mm/in 600 / 23.6 855 / 33.7 855 / 33.7DEPTH mm/in 245 / 9.7 328 / 12.1 328 / 12.1
WEI GHT (kg) 26 35 57 58
LI QUI D mm/in
GAS mm/in 15.88 / 5/812.7 / 1/2
I NPUT POWER
46
6.35 / 1/4
700 / 27.6
250 / 9.8
33
COMPRESSOR TYPE
540 / 21.3
RUNNI NG CURRENT
9.52 / 3/8
275 / 130
260 / 10.2799 / 31.5198 / 7.8
10 12
260 / 10.2899 / 35.4
POWER SOURCE
I NDOOR UNI T
OUTDOOR UNI TCOOLI NG ONLY
NOMI NAL COOLI NG CAPACI TY
HEAT PUMP
IND
OO
R U
NIT
DI MENSI ON
AI R TREATMENT DEVI CES
I NDOOR UNI T
OUTDOOR UNI T
AI R FI LTRATI ON
POWER SOURCE
FAN TYPE
NOMI NAL COOLI NG CAPACI TY
40 / 35 / 29
PI PE SI ZE
OU
TDO
OR
UN
IT
PIPE
PROTECTI ON DEVI CE
NON-THERMAL PLASMA (NTP) AI R STERI LI ZER
DI MENSI ON
TYPE
REFRI GERANT TYPE
198 / 7.8
NOMI NAL HEATI NG CAPACI TY
I NPUT POWER
EXTERNAL OVERLOAD PROTECTOR
220 -240 / 1 / 50
220 -240 / 1 / 50
ANTI -FUNGUS SKEW FAN
15
RUNNI NG CURRENT
AI R FLOW
306 / 12.01062 / 41.8
ROTARY HERMETI C
222 / 8.7
NEGATI VE I ON GENERATOR
R410A
FLARE VALVE
BUI LT-I N OVERLOAD PROTECTOR
NANOSI LVER-COATED ANTI -BACTERI AL SARANET FI LTER
NANOPHOTOCATALYST-COATED DEODORI ZI NG SARANET FI LTER