w mass oxford - university of oxford · oxford jan 2017 [email protected] 1 ... w pt spectrum....
TRANSCRIPT
![Page 1: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/1.jpg)
[email protected] Oxford Jan 2017 1
Precise measurement of W mass at LHC with the CMS detector
M. Bachtis*, M.R. d’ Alfonso, L. Perrozzi +GR+… CERN
O. Cerri, N. Foppiani, E. Manca, A. Stacchiotti Students @ Scuola Normale - Pisa
* now UCLA
![Page 2: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/2.jpg)
arXi
v:16
08.0
1509
GeV
![Page 5: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/5.jpg)
[email protected] Oxford Jan 2017
5
Past (and present) W mass measurements
mW = 80.370 ± 19 MeV
New ATLAS Measurement december 2016
8-98-105-3
9-14 2-13
6-12
ATLAS
11
7
14
7
ATLA
S N
umbe
rs
Gig
i’s B
reak
dow
n
![Page 6: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/6.jpg)
[email protected] Oxford Jan 2017 6
Measure μ pT : you need the prediction of the W pt distribution to measure the W mass.
Observable sensitive to Mw : muon transverse momentum
Mean 0.01145± 10.56
Std Dev 0.008099± 7.433
W Pt [GeV]0 5 10 15 20 25 30
Nor
mal
ized
ent
ries
/ 0.5
GeV
0.005
0.01
0.015
0.02
0.025
0.03 Mean 0.01145± 10.56
Std Dev 0.008099± 7.433
W Pt spectrum
![Page 7: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/7.jpg)
[email protected] Oxford Jan 2017 7
How to extract the W mass information from a distribution ?
1- Compare one measured distribution (eg pT of the muon) with several simulated distributions generated with different mass assumptions and compute the likelihood ratio.
100 MeVThis technique implies a perfect mastering of the simulation : W production and measurement of the event properties (muon, recoil)
![Page 8: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/8.jpg)
[email protected] Oxford Jan 2017 8
Transverse mass: in principle a more robuste observableIn these formulae p== pT
The jacobian edge preserves the mass information
sensitive to production and
decay dynamics
PT
ηcm
![Page 9: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/9.jpg)
[email protected] Oxford Jan 2017 9
Small distortions due to ISR and muon resolution
Plot done with ideal measurement of the hadronic recoil
![Page 10: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/10.jpg)
[email protected] Oxford Jan 2017 10
…. however it is difficult to measure precisely the hadronic recoil !
With a resolution of 7 GeV the edge is lost. Still very small dependence on the Wpt distribution
Resolution in CDF ~6-8 GeV Resolution in ATLAS ~ 13 GeV
![Page 12: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/12.jpg)
[email protected] Oxford Jan 2017 12
All silicon tracker ~ 1500 pixel modules and 15000 strip modules providing ~ 14 measurements ~ 10-50 μm per track in a magnetic field of 3.8 T
![Page 14: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/14.jpg)
[email protected] Oxford Jan 2017 14
W mass measurement strategy
Calibration of the muon momentum scale
Calibration of the hadronic recoil
Precise definition of the production model
J/Psi - Y samples
Z samples
Ancillary measurements
![Page 15: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/15.jpg)
[email protected] Oxford Jan 2017 15
CMS Statistics on tape
Lumi(1/)) Pileup J/Psi Y Z W+ W-
7TeV 5 7 3.5 1 1.4 13 9
8TeV 22 22 5.3 3 6.2 61 45
13TeV 4+35 13+24 122 49 39 ~350 ~250
Using 8 TeV only the statistical error is <2 MeV
Million Events
![Page 16: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/16.jpg)
[email protected] Oxford Jan 2017 16
Calibration of the momentum scale
The 16500 modules of the tracker are aligned with collision data and cosmic rays. Local precision 2 μm thanks to overlaps of nearby modules. Alignment has weak modes - geometry is prone to global scale deformations
Tracker in a very uniform magnetic field Map measured when CMS was the surface assembly hall. 2D approx. map used in the reconstruction
Momentum biassed by Energy Loss How well do we know the tracker material ?
Kc=AK+ε sinθ K2 + qM
B field and radial length
K=curvature=1/p
material effects transverse alignment10 η bins 10 η bins20 η bins
![Page 17: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/17.jpg)
[email protected] Oxford Jan 2017 17
Fitting dimuon resonances: kalman filter with target mass mc = dimuon generator mass after FSR
Magnetic field in data about 0.05 % higher than in simulation expected because of more iron in the cavern
x 500
Radial deformations < 0.1% level
Michalis Bachtis
![Page 18: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/18.jpg)
[email protected] Oxford Jan 2017 18
Material effects < 10 MeV
Transverse alignment terms ~ few 10-5 GeV-1
Calibration performed only with J/ψ and ΥZ used in the closure plots
![Page 19: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/19.jpg)
[email protected] Oxford Jan 2017 19
Fit correlations
70% correlation between material terms and B-field terms
![Page 20: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/20.jpg)
[email protected] Oxford Jan 2017 20
In situ measurement of the Material Budget
Using ~ 1-2 GeV tracks compute “local sagitta s” using measurements in three consecutive layers
Elisabetta Manca
The variance measures the multiple scattering
2 out of the 39 measured tracker layers
100 s of data taking
![Page 21: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/21.jpg)
[email protected] Oxford Jan 2017 21
Calibration of the recoil
Montecarlo study : which particles to use to measure the W recoil ?
At fix muon momentum plot the component of the recoil parallel to the muon direction
+……
![Page 22: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/22.jpg)
[email protected] Oxford Jan 2017 22
![Page 23: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/23.jpg)
[email protected] Oxford Jan 2017 23
Hadronic recoil, definition and calibration
Ideal detector, no pileup tracks + clusters
Real detector, pileup tracks+clusters
Ideal detector, no pileup only charged tracks
Real detector, pileup only charged tracks from muon vertex
Maria Rosaria d’ Alfonso
![Page 24: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/24.jpg)
[email protected] Oxford Jan 2017 24
Hadronic recoil calibrated with Z μμ events
Good closure of the recoil
![Page 25: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/25.jpg)
[email protected] Oxford Jan 2017 25
Hadronic recoil calibrated with Z μμ events
Response ~ 50% Resolution ~ 10 GeV
Response CDF ~ 65%, ATLAS ~ 90%
Tracks
![Page 27: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/27.jpg)
[email protected] Oxford Jan 2017 27
Measurement of the Z mass “as W” CMS-SMP-14-007
Production model addressed reweighing the Z MC to Z data: This measurement is just a test of the experimental calibrations
![Page 28: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/28.jpg)
[email protected] Oxford Jan 2017 28
180 k Z , stat 36 MeV, muons scale 13 MeV , recoil 10 MeV
CDF 620 k W , stat 16 MeV, muons scale 7 MeV , recoil 8 MeV
![Page 29: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/29.jpg)
[email protected] Oxford Jan 2017 29
More on recoil
Nicolo Foppiani Olmo CerriExploiting correlations
Different muon pT bins
![Page 32: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/32.jpg)
[email protected] Oxford Jan 2017 32
Effect of the PDF uncertainties on W mass
PT
ηcm
ηcm
ηL
YWpT>30 GeV ~ |ηcm | <0.7
At a given ηL you sample different Y corresponding to different pT changing average pT . And also W polarization effects
PT cut
![Page 33: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/33.jpg)
[email protected] Oxford Jan 2017 33
PDF Effects
At LHC, differently from Tevatron, W+ and W- have different cross sections
and have ~ equal rate because at leading order the s and bar(s) content of the proton is the same.
Subtracting W+ and W- distributions selects “valence” “sea” combinations and the PDF’s of c and s quarks enter only at “Cabibbo suppressed” level.
ATLAS
![Page 34: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/34.jpg)
[email protected] Oxford Jan 2017 34
PDF Mitigation
Fitting transverse mass in different η bins helps in reducing PDF systematic error.
Fit the μ pT-η rate with fine binning together with the W mass
![Page 36: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/36.jpg)
[email protected] Oxford Jan 2017 36
Angular coefficients
Perform the measurement at low pT ?ATLAS use fixed order NNLO prediction validating the model with Z measurement resulting in 5 MeV error.
![Page 37: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/37.jpg)
[email protected] Oxford Jan 2017 37
V Transverse Momentum Distribution
Fit prediction to Z data and apply to W
ATLAS considered Powheg+Pytia8 and Pytia8 standalone
After tuning 1% agreementprimordial kt αISR ISR cut-off
Exported to W
![Page 38: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/38.jpg)
[email protected] Oxford Jan 2017 38
Collinear gluon emission, factorization scale and quark masses
Gluon radiation has a cutoff depending on the quark mass
Depending how you vary the scale (W/Z correlations) , you get different results
![Page 39: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/39.jpg)
[email protected] Oxford Jan 2017 39
Resummation codes predict an harder pT W spectrum for a given measured pT Z spectrum
![Page 40: W mass Oxford - University of Oxford · Oxford Jan 2017 gigi.rolandi@cern.ch 1 ... W Pt spectrum. Oxford Jan 2017 gigi.rolandi@cern.ch 7 ... W_mass_Oxford.key](https://reader031.vdocuments.us/reader031/viewer/2022012403/5b4b79f17f8b9a35228bb659/html5/thumbnails/40.jpg)
[email protected] Oxford Jan 2017 40
Conclusions
CMS has calibrated the muon momentum scale to 0.02 % and there is room for further improvements
Measuring the W pt using charged tracks is possible and reasonably good resolution can be achieved. This allows to exploit the large luminosity collected at high pileup
The (non) agreement of the Z (W) pt spectrum with more advanced calculations based on resummation must be understood
We welcome very much the ATLAS measurement