vogt tube ice machines p18xt - vogt ice, llc
TRANSCRIPT
Vogt Tube Ice machines P18XTP18XT Features:
Note: Not available for 7/8” Ice Diameter
Revision 9/15/2013
VOGT TUBE-ICE MACHINES
Water CutterMin. Max. Fuse Min. Max. Fuse Pump Motor
Voltage F.L.A. Ampacity Size (Amps) F.L.A. Ampacity Size (Amps)208/230V, 3ph, 60hz 129.3 152.8 250 101.3 124.8 220
460V, 3ph, 60hz 70.2 83.3 140 56.2 69.3 125200V, 3ph, 50hz 162.1 193.4 320 134.1 165.4 295400V, 3ph, 50hz 81.3 96.9 160 67.3 82.9 150
EnergyUsageKWH/ Gal/ Liters/
Model Lbs Kg Lbs Kg Lbs Kg 100 lbs 100lbs 100lbsP18FXT - 1" 21,200 9616 20,000 9072 16,600 7530 2.51 2.35 8.89
P18FXT - 1 1/4" 19,460 8827 18,100 8210 15,780 7158 3.18 14.5 54.9 2.12 8.02 90 340P18FXT - 1 1/2" 18,300 8301 15,780 7158 14,500 6577 3.21 2.04 7.72
N O T E : E N E R G Y U S A G E A N D W A T E R R E Q U IR E M E N T S B A S E D O N M A K E U P W A T E R T E M P E R A T U R E O F 7 0 O F A M B IE N T ( A IR ) T E M P E R A T U R E O F 9 0 O F A N D 6 0 H Z P O W E R .
C A P A C IT Y R A T IN G IS A V E R A G E F O R T H E M O D E L . IN D IV ID U A L M A C H IN E S M A Y V A R Y +/ - 5 % . R E D U C E 15 % F O R 5 0 H Z .
M A K E -U P W A T E R U S A G E IN C L U D E S 2 0 % B L O W D O W N . K W H V A L U E S B A S E D O N W A T E R C O O L E D U N IT S .
Operating Conditions: Lbs Kg Lbs Kg4800 2177 1520 6904900 2223 1570 712
Air-Cooled Condensers: InOut
ReturnOut
2" FPT2-1/2" FPT
The ice machine shall not be subjected to an atmospheric temperature low er than 50 oF nor higher than 90 oF, w ithout effect on performance. Water for ice making purposes shall be non-corrosive. The w ater shall be at a constant pressure of not less than 30 psig at the ice machine location. The condition of the w ater to make satisfactory ice shall be the responsibility of the purchaser.
Shipping WeightOperating Weight
1" FPT1/2" MPT
Drain Connections
Line Size ConnectionsIce Making Water
Air Cooled
Make-Up Temperature
CondenserIce MachineMachine Weights
Water Cooled
50oF (10oC) 70oF (21oC) 90oF (32 oC)LPM
Model
LPM
CondenserFan Motor(s)
Ice MakingWater Usage
Motor Information
GPM
P18XT
24
Ice Machine Electrical Information
Machine CapacityCondenser
GPM
Compressor
H.P.
211 1/2 1/2 (qty 4) @ 1 1/2
The air-cooled condensers are available as remote units only, w ith 50/50 split coil and low ambient controls. Vogt requires that the air-cooled condensers be purchased from the Vogt factory for w arranty consideration and in order to assure proper sizing and operation. The ice capacity w ith an air-cooled unit w ill be the same as a w ater-cooled unit as long as the ambient temperature does not exceed 90 oF. For each 5 oF increase in ambient temperature above 90 oF, the ice capacity w ill be decreased by approximately 3%.
1 3/8" IDS1 3/8" IDS
Condenser Water Lines
Refrigerant Line Sizes fromIce Machine to Condenser