vl6000 beam ce compliance...
TRANSCRIPT
-
VL6000 BEAM CE COMPLIANCE DOCUMENTS
David Valentine Entertainment GBU
January 23, 2017
-
Philips Lighting
EC Declaration of Conformity, EC DoC
EC Declaration of Conformity
We, Philips Entertainment Lighting,
10911 Petal Street Dallas, Texas 75238-2424 USA
Internal Ref. Nr.:86-0948 Year in which CE Mark was first affixed: 2017
Declare under our responsibility for the products:
Product Range: Professional Luminaire
Product Code: VL6000 BEAM (20.9708.0001)
The designated products are in conformity with the essential requirements of the following European Directives and harmonized standards:
Low Voltage Directive (LVD), 2014/35/EU
EN 60598-2-17:1989 + A2:1991 used in conjunction with EN 60598-1:2008 + A11:2009
Electromagnetic compatibility Directive (EMC), 2014/30/EU
EN 55015:2006 + A1:2007, EN 61547: 1995, EN 61000-3-2:2014, EN 61000-3-3:2013,
Restriction of the use of certain Hazardous Substances in electrical and electronic equipment Directive(RoHS), 2011/65/EU
EN 50581:2012
17 January 2017 David Garcia
Q&R Manager, Business Entertainment
-
Philips Entertainment LIghting 10911 Petal Street Dallas, TX 75238-2424 USA
2017
Dear Customer
Philips Lighting Professional Stage and Studio Luminaires take its compliance with
European Union Directive 2011/65/EU Restriction of Hazardous Substances (ROHS) veryseriously. As part of our ongoing compliance commitment, we have completed a process to identify
which, if any, substances are contained within the product we supply to you.
This communication refers to the latest version of RoHS
Manufacturer Part Numbers: 20.9708.0001 VL6000 BEAM LUMINAIRE Date of Product Release January 2017
Date of Review: 29 January 2017
As part of this RoHS identification process we have:
reviewed internal/publicly available engineering data in relation to the presence of
RoHS in our products or any of their component parts;
reviewed available safety data sheets for all our input materials;
Communicated with our suppliers to exclude/confirm the presence of listed RoHS in
any component parts of our products.
As a result of this process, we confirm that, to the best of our knowledge, the product we
currently supply to you meets the RoHS directive.
Sincerely,
David Valentine Field Quality & Regulatory Engineer
-
Test Report issued under the responsibility of: Intertek Testing Services NA Inc
TEST REPORT IEC 60598-2-17
Luminaires Part 2: Particular requirements
Section 17: Luminaires for stage lighting, television and film studios (outdoor and indoor)
Report Number. .............................. : 102761244DAL-002
Date of issue ................................... : 2017-01-16
Total number of pages .................... 47
Name of Testing Laboratory preparing the Report ...................... :
Intertek Testing Services NA Inc
Applicant’s name ............................ : Genlyte Thomas Group, LLC
Address ........................................... : 10911 Petal street
Dallas TX, 75238, USA
Test specification:
Standard .......................................... : IEC 60598-2-17:1984 (First Edition) + A1:1987 + A2:1990 used in conjunction with IEC 60598-1:2014 (Eighth Edition)
Test procedure ............................... : Informative test report for technical file & to support manufacturer’s Declaration of Conformity to European Directive 2014/35/EU (Low Voltage Directive)
Non-standard test method ............. : N/A
Test Report Form No. ..................... : IEC60598_2_17D
Test Report Form(s) Originator..... : Intertek Semko AB
Master TRF ...................................... : 2015-08
Copyright © 2015 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.
-
Page 2 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Test item description ....................... : HID Moving Head Luminaire
Trade Mark ........................................ : Vari-Lite
Manufacturer .................................... : Genlyte Thomas Group, LLC
Model/Type reference ...................... : VL6000 BEAM
Ratings .............................................. : 220 – 240 Vac, 11A 50/60Hz, 50°C Ambient
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
CB Testing Laboratory:
Testing location/ address ............................. :
Associated CB Testing Laboratory:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 1:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 2:
Testing location/ address ............................. :
Tested by (name + signature) ...................... :
Witnessed by (name, function, signature) . :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 3:
Testing procedure: CTF Stage 4:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Witnessed by (name, function, signature) . :
Approved by (name, function, signature) ... :
Supervised by (name, function, signature) :
-
Page 3 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Testing procedure: LVD
Testing location/ address ............................. : Intertek Testing Services NA Inc.
1809 10th Street., Suite 400
Plano, TX 75074 USA
Tested by (name, function, signature) ........ : Fred Momanyi
Approved by (name, function, signature) ... : Mike Watson
List of Attachments (including a total number of pages in each attachment):
Attachment 1 - EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES, pages 42 - 43
Attachment 2 – PHOTOS, pages 44 - 47
Summary of testing:
Tests performed (name of test and test clause):
TEST PERFORMED EN 60598-2-17 (EN 60598-1)
Test of Marking 17.5 (3.4)
Screw Torque Test 17.6 (4.12.1)
Impact Test 17.6 (4.13.1)
Straight Test Finger 17.6 (4.13.3)
Mechanical Load Test 17.6 (4.14.1)
Flexing Test 17.6 (4.14.3)
Protective Shield Test 17.6.3 (-)
Mechanical Load Test 17.6.4 (-)
Secondary Suspension Test 17.6.6 (-)
Provision for Earthing 17.8 (7.2.1-7.2.3)
Protection Against Electric Shock Test 17.11 (8.2.5)
Capacitor Discharge Test 17.11 (8.2.7)
Endurance Test 17.12 (12.3)
Thermal test (normal operation) 17.12 (12.4)
IP 23 Test 17.13 (9.2)
Humidity Test 48 H 17.13 (9.3)
Insulation Resistance Test 17.14 (10.2.1)
Electric Strength Test 17.14 (10.2.2)
Touch Current 17.14 (10.3)
Testing location:
Intertek Testing Services NA Inc.
1809 10th Street., Suite 400
Plano, TX 75074
USA
-
Page 4 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Summary of compliance with National Differences:
List of countries addressed: EN
The product fulfils the requirements of EN 60598-2-17:1988 + A2:1991 used in conjunction with
EN 60598-1:2008 + A11:2009.
-
Page 5 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Copy of marking plate:
-
Page 6 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Marking also includes
“Do not stare at the operating light source Risk Group 2 Caution Possibly hazardous optical radiation emitted from this product”
-
Page 7 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Test item particulars...................................................:
Classification of installation and use.......................: 50°C Ambient, IP 23
Supply Connection .....................................................: 220 – 240 Vac, 11A, 50\60Hz
.......................................................................................:
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ........................................ : 2016-10-20
Date (s) of performance of tests ............................... : 2016-10-21 to 2017-01-16
General remarks:
"(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
Clause numbers between brackets refer to clauses in IEC 60598-1
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ............................................................... :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Genlyte Thomas, LLC
10911 Petal street
Dallas TX, 75238, USA
General product information:
The products are stage and studio luminaires for use by professionals. They are to be permanently connected and are to be mounted to the support by brackets provided. Refer to report 102761244DAL-003 report for details on photobiological testing.
-
Page 8 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.2 (0) GENERAL TEST REQUIREMENTS P
17.2 (0.1) Information for luminaire design considered ............ : Yes No
Lamp standard:
17.2 (0.3) More sections applicable ............................................ : Yes No
Section/s:
17.4 (2) CLASSIFICATION P
17.4 (2.2) Type of protection .................................................... : Class I P
17.4 (2.3) Degree of protection ................................................. : IP 23 P
17.4 (2.4) Luminaire suitable for direct mounting on normally flammable surfaces .................................................. :
Yes No
17.4 (2.5) Luminaire for normal use ........................................ : Yes No
Luminaire for rough service ..................................... : Yes No
17.5 (3) MARKING P
17.5 (3.2) Mandatory markings The following are required and present:
3.2.1: origin (trademark, manu, etc)
3.2.2: rated voltage
3.2.3: Ta 50°C
3.2.6: IP23
3.2.7: model
3.2.8: rated wattage
3.2.9: suitable for mounting on normally flammable surfaces
3.2.13: minimum distance form lighting objects 7.5 m
3.2.16: Marked "Replace any cracked protective shield", or the symbol.
3.2.22: Fuse marking with current.
3.2.23: Marked
P
Position of the marking Markings are visible before and after installation
P
Format of symbols/text All symbols at least 5mm tall. Letters 2mm tall.
P
17.5 (3.3) Additional information See below P
-
Page 9 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Language of instructions Instructions in language of target country
P
17.5 (3.3.1) Combination luminaires Not a combination luminaire N/A
17.5 (3.3.2) Nominal frequency in Hz 50 or 60 Hz P
17.5 (3.3.3) Operating temperature Temperatures marked P
17.5 (3.3.4) Symbol or warning notice Suitable for flammable surfaces N/A
17.5 (3.3.5) Wiring diagram Mains connected. N/A
17.5 (3.3.6) Special conditions None N/A
17.5 (3.3.7) Metal halide lamp luminaire – warning Marked as required P
17.5 (3.3.8) Limitation for semi-luminaires Not a semi luminaire N/A
17.5 (3.3.9) Power factor and supply current Information available from manufacturer.
P
17.5 (3.3.10)
Suitability for use indoors Suitable for use indoors or outdoors.
N/A
17.5 (3.3.11)
Luminaires with remote control No remote control gear. N/A
17.5 (3.3.12)
Clip-mounted luminaire – warning Not clip mounted. N/A
17.5 (3.3.13)
Specifications of protective shields Marked P
17.5 (3.3.14)
Symbol for nature of supply “~” provided. P
17.5 (3.3.15)
Rated current of socket outlet No socket outlets N/A
17.5 (3.3.16)
Rough service luminaire Not rough service N/A
17.5 (3.3.17)
Mounting instruction for type Y, type Z and some type X attachments
No cord. N/A
17.5 (3.3.18)
Non-ordinary luminaires with PVC cable No cord. N/A
17.5 (3.3.19)
Protective conductor current in instruction if applicable
Protective conductor current is less than 10mA
N/A
17.5 (3.3.20)
Provided with information if not intended to be mounted within arm’s reach
Not wall mounted or adjustable N/A
17.5 (3.3.21)
Non replaceable and non-user replaceable light sources information provided
Replaceable light source. N/A
Cautionary symbol Replaceable light source. N/A
17.5 (3.3.22)
Controllable luminaires, classification of insulation provided
Same insulation. P
17.5 (3.4) Test with water No adverse effects P
-
Page 10 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Test with hexane No adverse effects P
Legible after test Yes P
Label attached Yes P
17.5.1 (-) If luminaire design imposes restriction of use the luminaire is marked with N/A
a) Indication of the “top” No design restriction. N/A
b) Designed position or range of angle No design restriction. N/A
c) Mounting arrangements No design restriction. N/A
17.5.2 (-) Warning if lamp ≤ 250W 1500W. N/A
17.5.3 (-) Maximum ambient temperature ta Marked with ambient temperature.
P
17.5.4 (-) Minimum distances from flammable materials Marked to keep flammable objects away.
P
17.5.5 (-) Warning against opening immediately if applicable Marked to wait for 5 minutes. P
17.5.6 (-) Value of exterior surface temperature P
a) after 5 min P
b) when steady state P
17.5.7 (-) Instruction leaflet contain warnings P
a) Visibly damaged shields shall be changed Marked. P
b) Damaged or thermally deformed lamp shall bechanged
Marked. P
17.6 (4) CONSTRUCTION P
17.6 (4.2) Components replaceable without difficulty Easily replaceable. P
17.6 (4.3) Wireways smooth and free from sharp edges Wireways are protected. P
17.6 (4.4) Lampholders P
17.6 (4.4.1) Integral lampholder Not integral. N/A
17.6 (4.4.2) Wiring connection No integral lampholder. N/A
17.6 (4.4.3) Lampholder for end-to-end mounting Not for end-to-end mounting N/A
17.6 (4.4.4) Positioning Not user positioned. N/A
- pressure test (N) ................................................... : Not user positioned. —
After test the lampholder comply with relevant standard sheets and show no damage
Not user positioned. N/A
After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation
Not user positioned. N/A
- bending test (N) ..................................................... : Not user positioned. —
-
Page 11 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
After test the lampholder have not moved from its position and show no permanent deformation
Not user positioned. N/A
17.6 (4.4.5) Peak pulse voltage Peak voltage is
-
Page 12 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- test at 30 N Approved connector used. N/A
17.6 (4.8) Switches P
- adequate rating No switches. N/A
- adequate fixing No switches. N/A
- polarized supply No switches. N/A
- compliance with IEC 61058-1 for electronic switches
No switches. N/A
17.6 (4.9) Insulating lining and sleeves P
17.6 (4.9.1) Retainment Secured in place. P
Method of fixing ........................................................ : Secured by shrink wrap. P
17.6 (4.9.2) Insulated linings and sleeves: P
Resistant to a temperature > 20 C to the wire temperature or
Rated for 616°C P
a) & c) Insulation resistance and electric strength Rated for 616°C P
b) Ageing test. Temperature (C) ............................. : Rated for 616°C N/A
17.6 (4.10) Double or reinforced insulation N/A
17.6 (4.10.1)
No contact, mounting surface – accessible metal parts – wiring of basic insulation
Class I N/A
Safe installation fixed luminaires Class I N/A
Capacitors and switches Class I N/A
Interference suppression capacitors according to IEC 60384-14
Class I N/A
17.6 (4.10.2)
Assembly gaps: N/A
- not coincidental Class I N/A
- no straight access with test probe Class I N/A
17.6 (4.10.3)
Retainment of insulation: N/A
- fixed Class I N/A
- unable to be replaced; luminaire inoperative Class I N/A
- sleeves retained in position Class I N/A
- lining in lampholder Class I N/A
17.6 (4.11) Electrical connections and current-carrying parts P
17.6 (4.11.1)
Contact pressure No pressure through insulation. P
17.6 (4.11.2)
Screws: N/A
-
Page 13 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- self-tapping screws Machine screws used. N/A
- thread-cutting screws Machine screws used. N/A
17.6 (4.11.3)
Screw locking: N/A
- spring washer Screw connections are part of approved components.
N/A
- rivets No rivet electrical connections. N/A
17.6 (4.11.4)
Material of current-carrying parts Copper. P
17.6 (4.11.5)
No contact to wood or mounting surface No wood. P
17.6 (4.11.6)
Electro-mechanical contact systems No electrical mechanical contacts.
N/A
17.6 (4.12) Screws and connections (mechanical) and glands P
17.6 (4.12.1)
Screws not made of soft metal Stainless steel screws. P
Screws of insulating material No such screws. N/A
Torque test: torque (Nm); part .................................. : Thread measured 3.4mm Applied torque: 0.8Nm
P
17.6 (4.12.2)
Screws with diameter < 3 mm screwed into metal Screws into metal. P
17.6 (4.12.4)
Locked connections: N/A
- fixed arms; torque (Nm) ......................................... : No fixed arms. N/A
- lampholder; torque (Nm) ........................................ : No moving lampholder. N/A
- push-button switches; torque 0,8 Nm .................... : No switches. N/A
17.6 (4.12.5)
Screwed glands; force (Nm) ..................................... : No screwed glands. N/A
17.6 (4.13) Mechanical strength P
17.6 (4.13.1)
Impact tests: P
- fragile parts; energy (Nm) ...................................... : 0.2 Nm P
- other parts; energy (Nm) ........................................ : 0.35Nm P
1) live parts No damage P
2) linings No damage P
3) protection No damage P
4) covers No damage P
17.6 (4.13.3)
Straight test finger No live parts accessible P
-
Page 14 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.13.4)
Rough service luminaires N/A
- IP54 or higher Not for rough service use. N/A
a) fixed Not for rough service use. N/A
b) hand-held Not for rough service use. N/A
c) delivered with a stand Not for rough service use. N/A
d) for temporary installations and suitable for mounting on a stand
Not for rough service use. N/A
17.6 (4.13.6)
Tumbling barrel No plug-ballast/transformers N/A
17.6 (4.14) Suspensions, fixings and means of adjusting P
17.6 (4.14.1)
Mechanical load: P
A) four times the weight Tested per 17.6.4 P
B) torque 2,5 Nm Tested per 17.6.4 P
C) bracket arm; bending moment (Nm).................... : Tested per 17.6.4 P
D) load track-mounted luminaires Not track mounted. N/A
E) clip-mounted luminaires, glass-shelve. Thickness (mm) ........................................................................ :
Not clip mounted. N/A
Metal rod. diameter (mm) ........................................ : Not clip mounted. N/A
Fixed luminaire or independent control gear without fixing devices
Not clip mounted. N/A
17.6 (4.14.2)
Load to flexible cables N/A
Mass (kg) ................................................................. : No flexible cord. —
Stress in conductors (N/mm²) ................................. : No flexible cord. N/A
Mass (kg) of semi-luminaire .................................... : No flexible cord. N/A
Bending moment (Nm) of semi-luminaire ................ : No flexible cord. N/A
17.6 (4.14.3)
Adjusting devices: P
- flexing test; number of cycles ................................. : >1500 P
- strands broken ....................................................... : None P
- electric strength test afterwards P
17.6 (4.14.4)
Telescopic tubes: cords not fixed to tube; no strain on conductors
No telescoping tubes. N/A
17.6 (4.14.5)
Guide pulleys No pulleys. N/A
-
Page 15 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.14.6)
Strain on socket-outlets No outlets. N/A
17.6 (4.15) Flammable materials P
- glow-wire test 650C .............................................. : See Test Table 17.15 (13.3.2) N/A
- spacing 30 mm Spaced more than 30 mm. P
- screen withstanding test of 13.3.1 No screen. N/A
- screen dimensions No screen. N/A
- no fiercely burning material No such parts. P
- thermal protection Meets spacing requirements. N/A
- electronic circuits exempted Meets spacing requirements. N/A
17.6 (4.15.2)
Luminaires made of thermoplastic material with lamp control gear N/A
a) construction Metallic construction on controlgear.
N/A
b) temperature sensing control Metallic construction. N/A
c) surface temperature Metallic construction. N/A
17.6 (4.16) Luminaires for mounting on normally flammable surfaces P
No lamp control gear ................................................ : Has control gear. N/A
17.6 (4.16.1)
Lamp control gear spacing: P
- spacing 35 mm Spaced greater than 35 mm. P
- spacing 10 mm Meets spacing requirements. N/A
17.6 (4.16.2)
Thermal protection: N/A
- in lamp control gear Meets spacing requirement. N/A
- external Meets spacing requirement. N/A
- fixed position Meets spacing requirement. N/A
- temperature marked lamp control gear Meets spacing requirement. N/A
17.6 (4.16.3)
Design to satisfy the test of 12.6 Meets spacing requirement. N/A
17.6 (4.17) Drain holes P
Clearance at least 5 mm >5mm spacing. P
17.6 (4.18) Resistance to corrosion P
17.6 (4.18.1)
- rust-resistance Aluminum used for construction.
P
17.6 (4.18.2)
- season cracking in copper No such parts. N/A
-
Page 16 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.18.3)
- corrosion of aluminium Resistant to corrosion. P
17.6 (4.19) Ignitors compatible with ballast Compatible. P
17.6 (4.20) Rough service vibration Not for rough service. N/A
17.6 (4.21) Protective shield P
17.6 (4.21.1)
Shield fitted if tungsten halogen lamps or metal halide lamps
Shield provided. P
Shield of glass if tungsten halogen lamps Metal halide type. N/A
17.6 (4.21.2)
Particles from a shattering lamp not impair safety Surrounds the lamp. P
17.6 (4.21.3)
No direct path No direct path. P
17.6 (4.21.4)
Impact test on shield No damage P
Glow-wire test on lamp compartment ....................... : Metallic and glass. N/A
17.6 (4.22) Attachments to lamps not cause overheating or damage
No attachments. N/A
17.6 (4.23) Semi-luminaires comply Class II Not a semi-luminaire. N/A
17.6 (4.24) Photobiological hazards P
17.6 (4.24.1)
No excessive UV radiation if tungsten halogen lamps and metal halide lamps (Annex P)
P
17.6 (4.24.2)
Retinal blue light hazard P
Luminaires with Ethr : P
a) Fixed luminaires P
- distance x m, borderline between RG1 and RG2 .. : 294 m P
- marking and instruction according 3.2.23 Marked P
b) Portable and handheld luminaires Fixed N/A
- marking according 3.2.23 if RG1 exceeded at 200 mm according to IEC/TR 62778
N/A
Portable luminaires for children IEC 60598-2-10 and Mains socket outlet nightlights IEC 60598-2-12 not exceed RG1 at 200 mm according to IEC/62778
N/A
17.6 (4.25) Mechanical hazard P
No sharp point or edges No sharp places. P
17.6 (4.26) Short-circuit protection P
17.6 (4.26.1)
Adequate means of uninsulated accessible SELV parts
SELV circuits are not accessible.
N/A
-
Page 17 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.26.2)
Short-circuit test with test chain according 4.26.3 N/A
Test chain not melt through SELV circuits are not accessible.
N/A
Test sample not exceed values of Table 12.1 and 12.2
SELV circuits are not accessible.
N/A
17.6 (4.27) Terminal blocks with integrated screwless earthing contacts N/A
Test according Annex V No such terminal blocks. N/A
Pull test of terminal fixing (20 N) No such terminal blocks. N/A
After test, resistance < 0,05 No such terminal blocks. N/A
Pull test of mechanical connection (50 N) No such terminal blocks. N/A
After test, resistance < 0,05 No such terminal blocks. N/A
Voltage drop test, resistance < 0,05 No such terminal blocks. N/A
17.6 (4.28) Fixing of thermal sensing control N/A
Not plug-in or easily replaceable type No luminaire thermal sensing control.
N/A
Reliably kept in position No luminaire thermal sensing control.
N/A
No adhesive fixing if UV radiations from a lamp can degrade the fixing
No luminaire thermal sensing control.
N/A
Not outside the luminaire enclosure No luminaire thermal sensing control.
N/A
Test of adhesive fixing: N/A
Max. temperature on adhesive material (C) ........... : No luminaire thermal sensing control.
—
100 cycles between t min and t max No luminaire thermal sensing control.
N/A
Temperature sensing control still in position No luminaire thermal sensing control.
N/A
17.6 (4.29) Luminaires with non-replaceable light source N/A
Not possible to replace light source Lamp is replaceable. N/A
Live part not accessible after parts have been opened by hand or tools
Lamp is replaceable. N/A
17.6 (4.30) Luminaires with non-user replaceable light source N/A
If protective cover provide protection against electric shock and marked with “caution, electric shock risk” symbol:
N/A
Minimum two fixing means User replaceable. N/A
17.6 (4.31) Insulation between circuits P
-
Page 18 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Circuits insulated from LV supply fulfil requirements according 4.31.1 – 4.31.3
See below. P
Controllable luminaires requiring same level of insulation for all components, the insulation between control terminals and LV supply fulfil requirements according 4.31.1 – 4.31.3
See below. P
17.6 (4.31.1)
SELV circuits P
Used SELV source SELV control gear used. P
Voltage ≤ ELV Voltage is 24VDC and 48VDC P
Insulating of SELV circuits from LV supply Insulation provided within the power supply.
P
Insulating of SELV circuits from other non SELV circuits
Insulation provided within the power supply.
P
Insulating of SELV circuits from FELV No FELV circuits N/A
Insulating of SELV circuits from other SELV circuits One SELV source. N/A
SELV circuits insulated from accessible parts according Table X.1
Insulated. P
Plugs not able to enter socket-outlets of other voltage systems
No plugs. N/A
Socket outlets does not admit plugs of other voltage systems
No outlets. N/A
Plugs and socket-outlets does not have protective conductor contact
No outlets. N/A
17.6 (4.31.2)
FELV circuits N/A
Used FELV source No FELV circuits. N/A
Voltage ≤ ELV No FELV circuits. N/A
Insulating of FELV circuits from LV supply No FELV circuits. N/A
FELV circuits insulated from accessible parts according Table X.1
No FELV circuits. N/A
Plugs not able to enter socket-outlets of other voltage systems
No FELV circuits. N/A
Socket outlets does not admit plugs of other voltage systems
No FELV circuits. N/A
Socket-outlets does not have protective conductor contact
No FELV circuits. N/A
17.6 (4.31.3)
Other circuits P
-
Page 19 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Other circuits insulated from accessible parts according Table X.1
Insulated. P
Class II construction with equipotential bonding for protection against indirect contacts with live parts:
N/A
- conductive parts are connected together Class I. N/A
- test according 7.2.3 Class I. N/A
- conductive part not cause an electric shock in case of an insulation fault
Class I. N/A
- equipotential bonding in master/slave applications Class I. N/A
- master luminaire provided with terminal for accessible conductive parts of slave luminaires
Class I. N/A
- slave luminaire constructed as class I Class I. N/A
17.6 (4.32) Overvoltage protective devices N/A
Comply with IEC 61643-11 Part of approved controlgear. N/A
External to controlgear and connected to earth: N/A
- only in fixed luminaires Part of approved controlgear. N/A
- only connected to protective earth Part of approved controlgear. N/A
17.6.1 (-) Not possible to insert a lamp into a “live” lampholder if applicable
Exempt per amendment. N/A
17.6.2 (-) Prevent immediate access to the lamp or marked according 17.5.5 if applicable
Marked. P
17.6.3 (-) Fitted with a protective shield Shield provided P
Comply with test P
17.6.4 (-) Bearing parts of hanger are capable to support ten time the weight of the luminaire
670 lbs loaded. P
Non-combustible materials Metallic construction P
Parts of hanger carrying a proportion of the weight of the luminaire are capable to support ten time the proportion of weight
670 lbs loaded. P
Connection between hanger and luminaire locked Locked. P
17.6.5 (-) Removable accessories cannot fall out of the luminaire from any position
No removable accessories N/A
17.6.6 (-) If applicable a secondary suspension provided and passed the test
No hazard caused. P
17.7 (11) CREEPAGE DISTANCES AND CLEARANCES P
17.7 (11.2) Creepage distances and clearances ........................ : See Table 17.7 (11.2) P
Working voltage (V) .................................................. : 240V
-
Page 20 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Rated pulse voltage (kV) .......................................... : < 5 kV
Voltage form ............................................................. : Sinusoidal
Non-sinusoidal
PTI ............................................................................ : < 600 > 600
Impulse withstand category (Normal category II) (Category III Annex U)
Category II Category III
17.8 (7) PROVISION FOR EARTHING P
17.8 (7.2.1 + 7.2.3)
Accessible metal parts Earthed. P
Metal parts in contact with supporting surface P
Resistance < 0,5 ................................................... : 0.05Ω P
Self-tapping screws used None. N/A
Thread-forming screws None. N/A
Thread-forming screw used in a grove None. N/A
Earth makes contact first Approved connector that makes earthing connection first.
P
Terminal blocks with integrated screwless earthing contacts tested according Annex V
None. N/A
Protective earthing of the luminaire not via built-in control gear
P
17.8 (7.2.2 + 7.2.3)
Earth continuity in joints, etc. Continuity maintained. P
17.8 (7.2.4) Locking of clamping means Star washer used. P
Compliance with 4.7.3 See clause. P
Terminal blocks with integrated screwless earthing contacts tested according Annex V
Approved connectors. P
17.8 (7.2.5) Earth terminal integral part of connector socket Integral. P
17.8 (7.2.6) Earth terminal adjacent to mains terminals Part of the input connector. P
17.8 (7.2.7) Electrolytic corrosion of the earth terminal Similar metals. P
17.8 (7.2.8) Material of earth terminal Stainless steel type. P
Contact surface bare metal Bare P
17.8 (7.2.10)
Class II luminaire for looping-in Class I. N/A
Double or reinforced insulation to functional earth Class I. N/A
17.8 (7.2.11)
Earthing core coloured green-yellow Green-yellow. P
-
Page 21 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Length of earth conductor Connector used for input. N/A
17.9 (14) SCREW TERMINALS P
Separately approved; component list see Annex 1 P
Part of the luminaire Approved component. N/A
17.9 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS P
Separately approved; component list ....................... : see Annex 1 P
Part of the luminaire ................................................. : Approved component. N/A
17.10 (5) EXTERNAL AND INTERNAL WIRING P
17.10 (5.2) Supply connection and external wiring P
17.10 (5.2.1)
Means of connection ................................................ : Appliance inlet. P
Outdoor luminaire has not PVC insulated external wiring if not class III or SELV ≤ 25 V a.c./60 V d.c. or protected from outdoor environment
No cord. N/A
17.10 (5.2.2)
Type of cable ............................................................ : No cord. N/A
Nominal cross-sectional area (mm²) ........................ : No cord. N/A
Cables equal to IEC 60227 or IEC 60245 No cord. N/A
17.10 (5.2.3)
Type of attachment, X, Y or Z No cord. N/A
17.10 (5.2.5)
Type Z not connected to screws No cord. N/A
17.10 (5.2.6)
Cable entries: N/A
- suitable for introduction No cable entries. N/A
- adequate degree of protection No cable entries. N/A
17.10 (5.2.7)
Cable entries through rigid material have rounded edges
No cable entries. N/A
17.10 (5.2.8)
Insulating bushings: N/A
- suitably fixed No cables through the luminaire.
N/A
- material in bushings No cables through the luminaire.
N/A
-
Page 22 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- material not likely to deteriorate No cables through the luminaire.
N/A
- tubes or guards made of insulating material No cables through the luminaire.
N/A
17.10 (5.2.9)
Locking of screwed bushings None. N/A
17.10 (5.2.10)
Cord anchorage: N/A
- covering protected from abrasion No cord. N/A
- clear how to be effective No cord. N/A
- no mechanical or thermal stress No cord. N/A
- no tying of cables into knots etc. No cord. N/A
- insulating material or lining No cord. N/A
17.10 (5.2.10.1)
Cord anchorage for type X attachment: N/A
a) at least one part fixed No cord. N/A
b) types of cable No cord. N/A
c) no damaging of the cable No cord. N/A
d) whole cable can be mounted No cord. N/A
e) no touching of clamping screws No cord. N/A
f) metal screw not directly on cable No cord. N/A
g) replacement without special tool No cord. N/A
Glands not used as anchorage No cord. N/A
Labyrinth type anchorages No cord. N/A
17.10 (5.2.10.2)
Adequate cord anchorage for type Y and type Z attachment
No cord. N/A
17.10 (5.2.10.3)
Tests: N/A
- impossible to push cable; unsafe No cord. N/A
- pull test: 25 times; pull (N) ..................................... : No cord. N/A
- torque test: torque (Nm) ......................................... : No cord. N/A
- displacement 2 mm No cord. N/A
- no movement of conductors No cord. N/A
- no damage of cable or cord No cord. N/A
- function independent of electrical connection No cord. N/A
17.10 (5.2.11)
External wiring passing into luminaire No wires through luminaire. N/A
-
Page 23 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.10 (5.2.12)
Looping-in terminals No loop in terminals. N/A
17.10 (5.2.13)
Wire ends not tinned Wires not tinned. P
Wire ends tinned: no cold flow Wires not tinned. N/A
17.10 (5.2.14)
Mains plug same protection No plug. N/A
Class III luminaire plug Class I. N/A
No unsafe compatibility Class I. N/A
17.10 (5.2.16)
Appliance inlets (IEC 60320) Approved to IEC 60320. P.
Installation couplers (IEC 61535) Approved to IEC 60320. N/A
Other appliance inlet or connector according relevant IEC standard
Approved to IEC 60320. N/A
17.10 (5.2.17)
No standardized interconnecting cables properly assembled
No interconnecting cable. N/A
17.10 (5.2.18)
Used plug in accordance with N/A
- IEC 60083 No such plugs. N/A
- other standard No such plugs. N/A
17.10 (5.3) Internal wiring P
17.10 (5.3.1)
Internal wiring of suitable size and type Suitable wiring used. P
Through wiring N/A
- not delivered/ mounting instruction No through wiring. N/A
- factory assembled No through wiring. N/A
- socket outlet loaded (A) ......................................... : No through wiring. N/A
- temperatures .......................................................... : No through wiring. N/A
Green-yellow for earth only No through wiring. N/A
17.10 (5.3.1.1)
Internal wiring connected directly to fixed wiring P
Cross-sectional area (mm²) ...................................... : 2.03mm² P
Insulation thickness 0.76 mm P
Extra insulation added where necessary None. N/A
17.10 (5.3.1.2)
Internal wiring connected to fixed wiring via internal current-limiting device P
Adequate cross-sectional area and insulation thickness
Meets above requirements. N/A
-
Page 24 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.10 (5.3.1.3)
Double or reinforced insulation for class II Class I N/A
17.10 (5.3.1.4)
Conductors without insulation None. N/A
17.10 (5.3.1.5)
SELV current-carrying parts Insulated conductors. N/A
17.10 (5.3.1.6)
Insulation thickness other than PVC or rubber Insulation meets thickness requirements.
N/A
17.10 (5.3.2)
Sharp edges etc. No sharp edges. P
No moving parts of switches etc. No switches. N/A
Joints, raising/lowering devices No damage. P
Telescopic tubes etc. No tubes. N/A
No twisting over 360 No cables twisted. N/A
17.10 (5.3.3)
Insulating bushings: P
- suitable fixed Snaps in place P
- material in bushings Polymeric P
- material not likely to deteriorate P
- cables with protective sheath Sheath also used. P
17.10 (5.3.4)
Joints and junctions effectively insulated Insulated. P
17.10 (5.3.5)
Strain on internal wiring No external wires. N/A
17.10 (5.3.6)
Wire carriers None. N/A
17.10 (5.3.7)
Wire ends not tinned Not tinned N/A
Wire ends tinned: no cold flow Not tinned N/A
17.10.1 (-) Cross-sectional area (mm²)
≥ 0,75 for current ≤ 2A and ≥ 1,5 for current > 2A
2.08 mm² P
17.10.2 (-) Plugs and sockets not interchangeable Not interchangeable. P
17.11 (8) PROTECTION AGAINST ELECTRIC SHOCK P
17.11 (8.2.1)
Live parts not accessible Not accessible. P
Basic insulated parts not used on the outer surface without appropriate protection
Not accessible P
-
Page 25 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Basic insulated parts not accessible with standard test finger on portable, settable and adjustable luminaires
Not accessible P
Basic insulated parts not accessible with Ø 50 mm probe from outside, other types of luminaires
Not accessible P
Lamp and starterholders in portable and adjustable luminaires comply with double or reinforced insulation requirements
Meets requirement. P
Basic insulation only accessible under lamp or starter replacement
P
Protection in any position P
Double-ended tungsten filament lamp Metal Halide type. N/A
Insulation lacquer not reliable No lacquer. N/A
Double-ended high pressure discharge lamp Single ended. N/A
Relevant warning according to 3.2.18 fitted to the luminaire
Single ended. N/A
17.11 (8.2.2)
Portable luminaire adjusted in most unfavourable position
Checked in most unfavourable position.
P
17.11 (8.2.3.a)
Class II luminaire: N/A
- basic insulated metal parts not accessible during starter or lamp replacement
Class I. N/A
- basic insulation not accessible other than during starter or lamp replacement
Class I. N/A
- glass protective shields not used as supplementary insulation
Class I. N/A
17.11 (8.2.3.b)
BC lampholder of metal in class I luminaires shall be earthed
Not metal. N/A
17.11 (8.2.3.c)
SELV circuits with exposed current carrying parts: N/A
Ordinary luminaire: N/A
- touch current ......................................................... : Not exposed N/A
- no-load voltage ....................................................... : Not exposed N/A
Other than ordinary luminaire: N/A
- nominal voltage ..................................................... : Not exposed N/A
17.11 (8.2.4)
Portable luminaire have protection independent of supporting surface
Approved connector used. P
17.11 (8.2.5)
Compliance with the standard test finger or relevant probe
P
-
Page 26 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.11 (8.2.6)
Covers reliably secured Secured by screws. P
17.11 (8.2.7)
Discharging of capacitors 0,5 F Voltage was below the 1V within 1 second
P
Portable plug connected luminaire with capacitor P
Other plug connected luminaire with capacitor P
Discharge device on or within capacitor P
Discharge device mounted separately P
17.11.1 (-) Luminaires exempt from 17.6.1 requirements for protection against contact with live parts after opening does not apply
Not exempt from 17.6.1
17.12 (12) ENDURANCE TEST AND THERMAL TEST P
17.12 (12.3)
Endurance test: P
- mounting-position ................................................... : Hanging
- test temperature (C) ............................................. : 60
- total duration (h) ..................................................... : 240
- supply voltage: Un factor; calculated voltage (V) ... : 254
- lamp used ............................................................... : Philips MSR Gold 1500
17.12 (12.3.2)
After endurance test: P
- no part unserviceable No parts unserviceable P
- luminaire not unsafe Luminaire is not unsafe P
- no damage to track system No damage P
- marking legible Marking legible P
- no cracks, deformation etc. No damage P
17.12 (12.4)
Thermal test (normal operation) see Annex 2 P
17.12 (12.5)
Thermal test (abnormal operation) No abnormal conditions. N/A
17.12 (12.6)
Thermal test (failed lamp control gear condition): N/A
17.12 (12.6.1)
Through wiring or looping-in wiring loaded by a current of (A) ........................................................... :
Meets the requirements of 4.16.1
- case of abnormal conditions .................................. : Meets the requirements of 4.16.1
-
Page 27 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- electronic lamp control gear Meets the requirements of 4.16.1
N/A
- measured winding temperature (C): at 1,1 Un .... : Meets the requirements of 4.16.1
- measured mounting surface temperature (C) at 1,1 Un ....................................................................... :
Meets the requirements of 4.16.1
N/A
- calculated mounting surface temperature (C) ..... : Meets the requirements of 4.16.1
N/A
- track-mounted luminaires Not track mounted. N/A
17.12 (12.6.2)
Temperature sensing control N/A
- case of abnormal conditions .................................. : Meets the requirements of 4.16.1
- thermal link Meets the requirements of 4.16.1
N/A
- manual reset cut-out Meets the requirements of 4.16.1
N/A
- auto reset cut-out Meets the requirements of 4.16.1
N/A
- measured mounting surface temperature (C) ...... : Meets the requirements of 4.16.1
N/A
- track-mounted luminaires Not track mounted. N/A
17.12 (12.7)
Thermal test (failed lamp control gear in plastic luminaires): N/A
17.12 (12.7.1)
Luminaire without temperature sensing control N/A
17.12 (12.7.1.1)
Luminaire with fluorescent lamp ≤ 70W N/A
Test method 12.7.1.1 or Annex W .......................... : Not a fluorescent luminaire.
Test according to 12.7.1.1: N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- Ballast failure at supply voltage (V) ....................... : Fitted with temperature-independent support.
- Components retained in place after the test Fitted with temperature-independent support.
N/A
- Test with standard test finger after the test Fitted with temperature-independent support.
N/A
Test according to Annex W: N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- measured winding temperature (C): at 1,1 Un ..... : Fitted with temperature-independent support.
-
Page 28 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- measured temperature of fixing point/exposed part
(C): at 1,1 Un .......................................................... :
Fitted with temperature-independent support.
- calculated temperature of fixing point/exposed part
(C) ........................................................................... :
Fitted with temperature-independent support.
Ball-pressure test .................................................. : Fitted with temperature-independent support.
N/A
17.12 (12.7.1.2)
Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- measured winding temperature (C): at 1,1 Un ..... : Fitted with temperature-independent support.
- measured temperature of fixing point/exposed part
(C): at 1,1 Un .......................................................... :
Fitted with temperature-independent support.
- calculated temperature of fixing point/exposed part
(C) ........................................................................... :
Fitted with temperature-independent support.
Ball-pressure test ..................................................... : Fitted with temperature-independent support.
N/A
17.12 (12.7.1.3)
Luminaire with short circuit proof transformers ≤ 10 VA
Fitted with temperature-independent support.
N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- Components retained in place after the test Fitted with temperature-independent support.
N/A
- Test with standard test finger after the test Fitted with temperature-independent support.
N/A
17.12 (12.7.2)
Luminaire with temperature sensing control N/A
- thermal link ............................................................. : Yes No
- manual reset cut-out .............................................. : Yes No
- auto reset cut-out ................................................... : Yes No
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- highest measured temperature of fixing point/
exposed part (C): .................................................... :
Fitted with temperature-independent support.
Ball-pressure test: .................................................... : Fitted with temperature-independent support.
N/A
17.12.1 (-) Exterior surface temperature see Annex 2 P
17.13 (9) RESISTANCE TO DUST AND MOISTURE P
17.13 (9.2) Tests for ingress of dust, solid objects and moisture: P
- classification according to IP .................................. : IP 23
- mounting position during test ................................. : Tested standing upright.
-
Page 29 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- fixing screws tightened; torque (Nm) ..................... : No fixing screws.
- tests according to clauses ...................................... : 9.2 f, 9.2.4
- electric strength test afterwards P
a) no deposit in dust-proof luminaire N/A
b) no talcum in dust-tight luminaire N/A
c) no trace of water on current-carrying parts or on insulation where it could become a hazard
No water contact on live parts P
d) i) For luminaires without drain holes – no water entry
Drain holes provided. N/A
d) ii) For luminaires with drain holes – no hazardous water entry
No hazardous water contact. P
e) no water in watertight luminaire Not water tight. N/A
f) no contact with live parts (IP 2X) No contact with live parts P
f) no entry into enclosure (IP 3X and IP 4X) N/A
f) no contact with live parts (IP3X and IP4X) N/A
g) no trace of water on part of lamp requiring protection from splashing water
No water P
h) no damage of protective shield or glass envelope No damage P
17.13 (9.3) Humidity test 48 h P
17.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P
17.14 (10.2.1)
Insulation resistance test P
Cable or cord covered by metal foil or replaced by a metal rod of mm Ø ................................................... :
No cord.
Insulation resistance (M) ....................................... : >10GΩ @ 500V
SELV P
- between current-carrying parts of different polarity : >10GΩ @ 100V P
- between current-carrying parts and mounting surface ...................................................................... : >10GΩ @ 100V
P
- between current-carrying parts and metal parts of the luminaire ............................................................. : >10GΩ @ 100V
P
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. : No cord
N/A
- Insulation bushings as described in Section 5 ...... : >10GΩ @ 500V P
Other than SELV P
-
Page 30 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- between live parts of different polarity ................... : >10GΩ @ 500V P
- between live parts and mounting surface .............. : >10GΩ @ 500V P
- between live parts and metal parts ........................ : >10GΩ @ 500V P
- between live parts of different polarity through action of a switch ...................................................... : No switch
N/A
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. : No cord
N/A
- Insulation bushings as described in Section 5 ...... : >10GΩ @ 500V P
17.14 (10.2.2)
Electric strength test
Dummy lamp P
Luminaires with ignitors after 24 h test P
Luminaires with manual ignitors No manual ignitor N/A
Test voltage (V) ........................................................ : 1480Vac 60hz P
SELV
- between current-carrying parts of different polarity : Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- between current-carrying parts and mounting surface ...................................................................... :
Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- between current-carrying parts and metal parts of the luminaire ............................................................. :
Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. :
Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- Insulation bushings as described in Section 5 ...... : Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
Other than SELV
- between live parts of different polarity ................... : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- between live parts and mounting surface .............. : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- between live parts and metal parts ........................ : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- between live parts of different polarity through action of a switch ...................................................... :
N/A
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. :
Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- Insulation bushings as described in Section 5 ...... : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
7.14 (10.3) Touch current or protective conductor current (mA) : 0.68 mA P
-
Page 31 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.15 (13) RESISTANCE TO HEAT, FIRE AND TRACKING N/A
17.15 (13.2.1)
Ball-pressure test ..................................................... : Polymeric is spaced away. N/A
17.15 (13.3.1)
Needle-flame test (10 s) ........................................... : N/A
17.15 (13.3.2)
Glow-wire test (650C) ............................................. : N/A
17.15 (13.4)
Proof tracking test (IEC 60112) ................................ : N/A
-
Page 32 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.7 (11.2) TABLES: Creepage distances and clearances
Table 11.1 Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages
RMS working voltage (V) not exceeding 50 150 250 500 750 1000
Creepage distances
Required basic insulation, PTI 600 0,6 0,8 1,5 3 4 5,5
Measured
Required basic insulation, PTI < 600 1,2 1,6 2,5 5 8 10
Measured
Required supplementary insulation PTI 600 - 0,8 1,5 3 4 5,5
Measured
Required supplementary insulation PTI < 600 - 1,6 2,5 5 8 10
Measured
Required reinforced insulation - 3,2 5 6 8 11
Measured
Clearances
Required basic insulation 0,2 0,8 1,5 3 4 5,5
Measured
Required supplementary insulation - 0,8 1,5 3 4 5,5
Measured
Required reinforced insulation - 1,6 3 6 8 11
Measured
Table 11.2 Minimum distances (mm) for non-sinusoidal pulse voltages
Rated pulse voltage (peak kV) 2,0 2,5 3,0 4,0 5,0 6,0 8,0
Required clearances 1,0 1,5 2 3 4 5,5 8
Measured
Rated pulse voltage (peak kV) 10 12 15 20 25 30 40
Required clearances 11 14 18 25 33 40 60
Measured
Rated pulse voltage (peak kV) 50 60 80 100 - - -
Required clearances 75 90 130 170 - - -
Measured
-
Page 33 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.15 (13.2.1)
TABLE: Ball Pressure Test of Thermoplastics
Allowed impression diameter (mm) .................... :
Object/ Part No./ Material Manufacturer/ trademark
Test temperature (C) Impression diameter (mm)
Supplementary information:
17.15 (13.3.1)
TABLE: Needle-flame test (IEC 60695-11-5)
Object/ Part No./ Material
Manufacturer/ trademark
Duration of application of test
flame (ta); (s)
Ignition of specified layer
Yes/No
Duration of burning (tb)
(s) Verdict
Supplementary information:
17.15 (13.3.2)
TABLE: Glow-wire test (IEC 60695-2-11)
Glow wire temperature ......................................... : 650°C
Object/ Part No./ Material
Manufacturer/ trademark
Ignition of specified layer
Yes/No
Duration of burning (tb)
(s) Verdict
Any flame or glowing of the sample extinguished within 30 s of withdrawing the glow-wire, and any burning or molten drop did not ignite the underlying parts (Yes/No) ...................................... :
Supplementary information:
-
Page 34 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.15 (13.4)
TABLE: Proof tracking test (IEC 60112)
Test voltage PTI .................................................... : 175 V
Object/ Part No./ Material Manufacturer/ trademark
Withstand 50 drops without failure on three places or on three specimens
Verdict
Supplementary information:
-
Page 35 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 1 TABLE: Critical components information P
Object / part No.
Code Manufacturer/ trademark
Type / model Technical data Standard Mark(s) of conformity
1)
Enclosure A Sabic Innovative Plastics
EFX830ME
Polymeric, Minimum 2.15
mm thick, 90°C, Flame Rating: 5VA
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Lens A Various Various Glass, 2.75mm thick
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Centrifugal Fans A YS Tech USA BW09733012BH
12VDC, 0.74A, Polymeric, V-0, 32.4 CFM, 3800 RPM
UL 507 cURus
Crossflow Fan A Y.S. Tech CFS09825012BH
7.2CFM, 12VDC, 0.13A
UL 507 cURus
Lamp Enclosure A Various Various Aluminum, 2mm thick, 150x150x160mm
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Ballast B CCI Power Supplies
SBC1500
55°C Input: 208-240VAC, 50/60Hz, 8.48A Output: 100VAC, 15A
EN61347-2-12
CE
Lampholder B Bender & Wirth GMBH & CO
PGJX50
250V, 30A,
Max °350, Ignition voltage: 5kV
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Filter Philips Entertainment
416189RC
Evaluated under Intertek report 101422452DAL-001.
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Bulb A Various Various 950°C, 198V, Metal Halide, 1500W
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Power Supply B CCI Power Supplies
LM200P
Input: 100-277VAC, 50/60Hz, 2.6A Output: 24, 48VDC, 8.3A Max
EN60950 CE
Label B Various Various
80°C minimum temperature, suitable for adhesion to the surface it is applied to.
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
-
Page 36 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Lamp Containment Barrier
A Various Various Glass, 2.75mm thick
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
PCB, Ignitor A ALLIED PCB. LLC
11-9704-1126 REV B
V-0, Max 90°C
IEC 60598-2-17:1984+A1:1987+A2:1990 UL 94
Evaluated per
requirements
cURus
PWB, Ignitor A Philips VL4000 Ignitor Board
Uses PCB, Ignitor IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Coil, Ignitor C NOVA MAGNETICS
68.9704.1127
Ferrite Rod core, 14AWG wiring, Insulation Class B
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Resistors, Ignitor (x 2)
A Xicon Passive Components
286-30K-RC
Ceramic core, 235°C, 30kΩ, 5W, Metal Oxide Axial
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Supplementary information: 1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.
The codes above have the following meaning:
A - The component is replaceable with another one, also certified, with equivalent characteristics
B - The component is replaceable if authorised by the test house
C - Integrated component tested together with the appliance
D - Alternative component
-
Page 37 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 2 TABLE: Temperature measurements, thermal tests of Section 12 P
Type reference ....................................................... : VL 6000 Luminaire
Lamp used .............................................................. : Philips MSR Gold 1500
Lamp control gear used .......................................... : CCI Power Supplies SBC1500
Mounting position of luminaire ............................... : Upright
Supply wattage (W) ................................................ : 1700W
Supply current (A) .................................................. : 7.4
Calculated power factor .......................................... : 0.93
Table: measured temperatures corrected for ta = 50 C: P
- abnormal operating mode .................................... : N/A
- test 1: rated voltage .............................................. : N/A
- test 2: 1,06 times rated voltage or 1,05 times rated wattage ................................................................... :
254V
- test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ................................ :
N/A
- test 4: 1,1 times rated voltage or 1,05 times rated wattage ................................................................... :
N/A
Through wiring or looping-in wiring loaded by a current of A during the test .................................... :
N/A
Temperature measurements, (C)
Part Ambient Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Wires to lampholder
50 162.6 163.1 N/A 200 N/A N/A
Ignitor 50 96.7 97.6 N/A 105 N/A N/A
Cooling fan 50 106.6 107 N/A 120 N/A N/A
Cutter cooling fan
50 72.9 75.6 N/A 85 N/A N/A
Filter cap 50 84.9 84.4 N/A 105 N/A N/A
Ballast 50 78.8 79.6 N/A 90 N/A N/A
DC power supply
50 63.0 60.8 N/A 90 N/A N/A
Input connection 50 79.2 79.6 N/A 90 N/A N/A
Filter transformer
50 98.6 95.2 N/A 120 N/A N/A
Lampholder 50 151.6 152 N/A 200 N/A N/A
-
Page 38 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Input wire 50 84.2 84 N/A 105 N/A N/A
Tilt motor 50 74.3 75.1 N/A 90 N/A N/A
Gasket near lamp
50 91.1 91.6 N/A 200 N/A N/A
Filter coil 50 92.8 90.6 N/A 120 N/A N/A
Power dist. Board
50 94.7 94.7 N/A 130 N/A N/A
Terminal block 50 69.4 70.4 N/A 105 N/A N/A
Enclosure 50 90.2 91.2 N/A 90 N/A N/A
DC connectors 50 71.2 72.4 N/A 90 N/A N/A
Supplementary information:
-
Page 39 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 3 Screw terminals (part of the luminaire) N/A
(14) SCREW TERMINALS N/A
(14.2) Type of terminal ........................................................ : Approved terminals used.
Rated current (A) ...................................................... :
(14.3.2.1) One or more conductors N/A
(14.3.2.2) Special preparation N/A
(14.3.2.3) Terminal size N/A
Cross-sectional area (mm²) ...................................... :
(14.3.3) Conductor space (mm) ............................................. : N/A
(14.4) Mechanical tests N/A
(14.4.1) Minimum distance N/A
(14.4.2) Cannot slip out N/A
(14.4.3) Special preparation N/A
(14.4.4) Nominal diameter of thread (metric ISO thread) ...... : M N/A
External wiring N/A
No soft metal N/A
(14.4.5) Corrosion N/A
(14.4.6) Nominal diameter of thread (mm) ............................ : N/A
Torque (Nm) ............................................................. : N/A
(14.4.7) Between metal surfaces N/A
Lug terminal N/A
Mantle terminal N/A
Pull test; pull (N) ....................................................... : N/A
(14.4.8) Without undue damage N/A
-
Page 40 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 4 Screwless terminals (part of the luminaire) N/A
(15) SCREWLESS TERMINALS N/A
(15.2) Type of terminal ........................................................ : Approved component.
Rated current (A) ...................................................... :
(15.3.1) Material N/A
(15.3.2) Clamping N/A
(15.3.3) Stop N/A
(15.3.4) Unprepared conductors N/A
(15.3.5) Pressure on insulating material N/A
(15.3.6) Clear connection method N/A
(15.3.7) Clamping independently N/A
(15.3.8) Fixed in position N/A
(15.3.10) Conductor size N/A
Type of conductor N/A
(15.5) Terminals and connections for internal wiring N/A
(15.5.1) Mechanical tests N/A
(15.5.1.1.1) Pull test spring-type terminals (4 N, 4 samples) ...... : N/A
(15.5.1.1.2) Pull test pin or tab terminals (4 N, 4 samples) ......... : N/A
Insertion force not exceeding 50 N N/A
(15.5.1.2) Permanent connections: pull-off test (20 N) N/A
(15.5.2) Electrical tests
Voltage drop (mV) after 1 h (4 samples) .................. : N/A
Voltage drop of two inseparable joints N/A
Number of cycles:
Voltage drop (mV) after 10th alt. 25th cycle (4 samples) ............................................................... :
N/A
Voltage drop (mV) after 50th alt. 100th cycle (4 samples) ............................................................... :
N/A
After ageing, voltage drop (mV) after 10th alt. 25th cycle (4 samples) ............................................. :
N/A
After ageing, voltage drop (mV) after 50th alt. 100th cycle (4 samples) ........................................... :
N/A
(15.6) Terminals and connections for external wiring N/A
(15.6.1) Conductors N/A
-
Page 41 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Terminal size and rating N/A
15.6.2 Mechanical tests N/A
(15.6.2.1) Pull test spring-type terminals or welded connections (4 samples); pull (N) ................................................ :
N/A
(15.6.2.2) Pull test pin or tab terminals (4 samples); pull (N) ..................................................................... :
N/A
(15.6.3) Electrical tests N/A
Tests according 15.6.3.1 + 15.6.3.2 in IEC 60598-1 N/A
(15.6.3.1)
(15.6.3.2) TABLE: Contact resistance test / Heating tests
Voltage drop (mV) after 1 h
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop of two inseparable joints
Voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Supplementary information:
-
Page 42 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ATTACHMENT TO TEST REPORT IEC 60598-2-17 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
LUMINAIRES PART 2: PARTICULAR REQUIREMENTS:
SECTION SEVENTEEN - LUMINAIRES FOR STAGE LIGHTING, TELEVISION AND FILM STUDIOS (OUTDOOR AND INDOOR)
Differences according .................... : EN 60598-2-17:1989 + A2:1991 used in conjunction with EN 60598-1:2008 + A11:2009
Annex Form No. .............................. : EU_GD_IEC60598_2_17C
Annex Form Originator ..................... : IMQ S.p.A.
Master Annex Form .......................... : 2010-08
Copyright © 2010 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.
CENELEC COMMON MODIFICATIONS (EN) P
17.5 (3) MARKING N/A
17.5 (3.3.101)
Adequate warning on the package No terminal blocks N/A
17.6 (4) CONSTRUCTION N/A
17.6 (4.11.6) Electro-mechanical contact systems No electrical mechanical contact systems
N/A
17.10 (5) EXTERNAL AND INTERNAL WIRING P
17.10 (5.2.1) Connecting leads Luminaire supplied with appliance inlet.
P
- without a means for connection to the supply Luminaire supplied with appliance inlet.
N/A
- terminal block specified No terminal block for connecting leads
N/A
- relevant information provided Relevant information is provided
N/A
- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12 and 13.2 of Part 1
Terminal block is not used for supply connections
N/A
17.10 (5.2.2) Cables equal to HD21 S2 or HD22 S2 No cable. N/A
17.12 (12) ENDURANCE TEST AND THERMAL TEST N/A
17.12 (12.4.2c)
Thermal test (normal operation) see footnote c to table 12.2 relating to unsleeved fixed wiring
All installations supplied with luminaire
N/A
-
Page 43 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) P
(3.3) DK: power supply cord with label Present P
IT: warning label on Class 0 luminaire Not a class 0 luminaire N/A
(4.5.1) DK: socket-outlets No socket outlets N/A
(5.2.1) CY, DK, FI, SE, GB: type of plug No plug included N/A
ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A
(4 & 5) FR: Shuttered socket-outlets 10/16A No outlets of the type referenced used.
N/A
(13.3) FR: Glow-wire test 850C alt. 750C for luminaires in premises open to public or 960°C for luminaires in emergency exits
Aluminum enclosure with polymeric covers spaced from uninsulated live parts.
N/A
(13.3) GB: Requirements according to United Kingdom Building Regulation
Not intended to be used on a suspended ceiling
N/A
-
Page 44 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 1 - External view of model VL6000 BEAM
Photo 2 - External view of model VL6000 BEAM
-
Page 45 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 3 - Internal view of model VL6000B
Photo 4 - Internal view of model VL6000B
-
Page 46 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 5 - View of Ignitor board
Photo 6 - Internal view of model VL6000B
-
Page 47 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 7 - Internal view of model VL6000B
-
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Non-Specific EMC Report Shell Rev. March 2014 Genlyte Thomas Group LLC VL6000
Page 1 of 56
EMC TEST REPORT
Report Number: 102761244DAL-005
Project Number: G102761244
Report Issue Date: November 21, 2016
Product Designation: VL6 Moving Head HID Luminaire
Model(s): VL6000
Standards: FCC 47CFR 15B Issued:2011/04/21 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class B Verification
ICES-005 Issued:2007/02/01 Issue No. 2 Radio Frequency Lighting Devices
CENELEC EN 55015 Issued: 2006/12/01 Limits and Methods of Measurement of Radio Disturbance Characteristics of Electrical Lighting and
Similar Equipment; Incorporating Amendment A1: 5/2007
CENELEC EN 61547 Issued: 01/01/1995 Equipment for General Lighting Purposes EMC Immunity Requirements (IEC 1547: 1995)
CENELEC EN61000-3-2 Issued: 2014/08/01 Electromagnetic Compatibility (EMC) - Part 3-2: Limits - Limits for Harmonic Current Emissions
CENELEC EN61000-3-3 Issued: 2013/08/01 Electromagnetic Compatibility (EMC) -Part 3-3: Limits -Limitation of Voltage Changes, Fluctuations & Flicker in Public Low-Voltage Supply Systems
Tested by: Client: Intertek Testing Services NA, Inc.
1809 10th Street Suite 400 Plano, TX 75074
Genlyte Thomas Group LLC 10911 Petal St
Dallas, TX 75238-2424
Report prepared by Report reviewed by
Gary Shimko Compliance Investigator
Rick Hill Compliance Investigator
-
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 2 of 56 Genlyte Thomas Group LLC VL6000
1 Introduction and Conclusion
The tests indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted.
Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested.
2 Test Summary
Section Test full name Result Date
3 Client Information
4 Description of Equipment Under Test
5 System Setup and Method
6 Radiated Emissions (CISPR 15: Date)
Pass November 8, 2016
7 AC Mains Conducted Emissions (CISPR 15: Date)
Pass November 9, 2016
& November 23, 2016
9 Harmonics (CENELEC EN61000-3-2: 2014)
Pass November 9, 2016
10 Flicker (CENELEC EN61000-3-3: 2013)
Pass November 9, 2016
11 Electro-Static Discharge Immunity Test (IEC 61000-4-2:2008)
Pass November 11, 2016
12 Radiated, Radio-Frequency, Electromagnetic Immunity (IEC 61000-4-3:2006)
Pass November 14, 2016
13 Electrical Fast Transient/Burst Immunity Test (IEC 61000-4-4:2004)
Pass November 11, 2016
14 Immunity to Surges (IEC 61000-4-5:2005)
Pass November 11, 2016
15 Conducted, Radio-Frequency, Electromagnetic Immunity Test (IEC 61000-4-6:2008)
Pass November 11, 2016
16 Power Frequency Magnetic Field Immunity Test (IEC 61000-4-8:1993)
Pass November 14, 2016
17 Voltage Dips /Interruptions Immunity Test (IEC 61000-4-11:2004)
Pass November 10, 2016
18 Revision History
-
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 3 of 56 Genlyte Thomas Group LLC VL6000
3 Client Information This EUT was tested at the request of:
Company: Genlyte Thomas Group LLC 10911 Petal St Dallas, TX 75238-2424
Contact: David Valentine
Telephone: (214) 647-7910
Email: [email protected]
4 Description of Equipment Under Test
Manufacturer: Genlyte Thomas Group LLC 10911 Petal Street Dallas, TX 75238-2424 USA
Equipment Under Test
Description Manufacturer Model Number Serial Number
VL6 Moving Head HID
Luminaire
Genlyte Thomas
Group LLC
VL6000 DAL1611081156-001
Receive Date: 11/08/2016
Received Condition: Good
Type: Engineering
Description of Equipment Under Test (provided by client)
The Genlyte Thomas Group LLC VL6 Moving Head Luminaire is a Moving Head High Intensity
Discharge Luminaire.
Equipment Under Test Power Configuration
Rated Voltage Rated Current Rated Frequency Number of Phases
220-240 VAC 8.9 A 50/60 Hz Single Phase
Operating modes of the EUT:
No. Descriptions of EUT Exercising
1 Three dimensional rotating Head HID Luminaire with different colors
Software used by the EUT:
No. Descriptions of EUT Exercising
1 VL6000_101816.bin
-
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 4 of 56 Genlyte Thomas Group LLC VL6000
5 System Setup and Method
Cables
ID
Description
Length
(m)
Shielding
Ferrites
Termination
1 powerCON AC Mains Power Cord 1.5 No No AC
connector on VL6
2 5-pin DMX cable 1 No No Load Box – Pin 1 tied to metal box
Support Equipment
Description Manufacturer Model Number Serial Number
1DMX Load metal Termination Box
Genlyte / Phillips None None
5.1 Method: Configuration as required by IEC 61547.
5.2 EUT Block Diagram:
-
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 5 of 56 Genlyte Thomas Group LLC VL6000
5.3 EUT Performance Criteria and Monitoring: Performance as required by IEC 61547.
Product Specific Performance:
No. Description
A During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Description of