view pdf - bell power systems inc

13
TAKE A CLOSER LOOK AT POWERVIEW. THE LATEST ADDITION TO THE MURPHYLINK TM FAMILY.

Upload: others

Post on 09-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: View PDF - Bell Power Systems Inc

TAKE A CLOSER LOOK

AT POWERVIEW.

THE LATEST ADDITION TO THE MURPHYLINKTM

FAMILY.

Page 2: View PDF - Bell Power Systems Inc

INTRODUCING THE NEXT GENERATION

MURPHYLINK� SYSTEM. POWERVIEW

INSTRUMENTS AND GAGES ARE THE MOST

ADVANCED J1939 CAN SOLUTIONS

FOR WHATEVER APPLICATION

YOU�RE RUNNING. WHETHER YOU

NEED INSTRUMENTS FOR MOBILE

OR STATIONARY APPLICATIONS,

POWERVIEW IS THE SOLUTION FOR

ALL YOUR EQUIPMENT.

Page 3: View PDF - Bell Power Systems Inc

NOW YOU KNOW WHAT YOUR ELECTRONIC ENGINE IS TELLING YOU.

ow, with PowerView, operators see what your engine’s

Electronic Control Unit (ECU) is telling them in plain text.

It puts the information where it’s needed most — at the

operator’s fingertips.

A large LCD graphical display and smooth gage

pointer operation makes the PowerView and associated gages

easier to use and understand. PowerView gives you choices

in bezel designs and colors. Even better, all PowerView com-

ponents feature plug and go convenience for easy installation,

and they’re available in both standard and custom panels.

With years of experience, nobody knows more about

J1939 CAN instrumentation than we do. Just what you’d

expect from a company with a 60-year heritage as the Engine

Protection Company. Spec the new PowerView system today.

}N

Page 4: View PDF - Bell Power Systems Inc

Available Instrumentation.• PowerView features a large graphical screen with a great viewing angle and contrast• PowerView Audible Alarm alerts operators to fault conditions via piezoelectric alarm and relay contacts• Multiple bezels and color options available• PowerView Analog Gages display information transmitted from the PowerView in the traditional analog formats shown below:

Engine Oil Pressure Engine Coolant Temperature

12 or 24 VDC Voltmeter

Percent LoadTachometer Audible Alarm

(See PowerView Analog Gage information for other options available)

Accurate, Reliable Operation.• Accurate electronic engine and transmission data via SAE J1939 CAN• PowerView translates information from electronic engines for precise

operation of gages or remote communication• All PowerView components are environmentally sealed• Wide operating temperature range

Enhanced Gage Design.• Gages are stepper motor driven allowing smooth pointer operation • Stepper motor design provides more linear scale, less pointer bounce• PowerView Analog Gages feature intelligent communications• Self-diagnostics available on start-up for PowerView Analog Gages

Understandable Diagnostics.• PowerView displays standard J1939 fault codes with text descriptions

for common faults • Ultra-bright alarm and shutdown LEDs• Large, easy-to-read fault symbols displayed

Easy-to-Read & Use.• PowerView features fully graphical LCD screen• Four touch-sensitive buttons feature increased size and spacing

for scrolling and parameter selection• Display information in single or quadrant (4 parameter) views• Long-lasting green LED backlighting for both the PowerView

and PowerView Analog Gages• Backlighting intensity adjustable via PowerView menu or

external dimmer potentiometer• PowerView Analog Gages feature 270° pointer sweep

Convenient Installation Options.• PowerView fits standard 2-1/16 in. (52 mm) hole opening• Powerview Analog Gages available in standard 2-1/16 in. (52 mm)

and 3-3/8 in. (86 mm) size hole openings• Two 6-pin DeutschTM DT style connectors molded into casing for quick

connections and simple daisy-chain wiring• Standard connection harnesses available• "Plug and Go" standard and customizable panels available

with harnesses for all major engine manufacturers

1 2 3 4 5 6

Page 5: View PDF - Bell Power Systems Inc
Page 6: View PDF - Bell Power Systems Inc

FW MurphyP.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com

specifications

03014H Rev. 9-04

4.25 in.(108 mm)

4.25 in.(108 mm)

FRONT BACK

SIDE HOLE CUTOUT

2.41 in.(61 mm)

0.78 in.(20 mm) 3.18 in.

(81 mm)

3.489 in.(89 mm)

2.070 in.(53 mm)

1.94 in.(50 mm)

1.972 in. (50 mm)

R 0.063 in. (1.6 mm)

0.125 in. (3 mm)

2.062 in. (52 mm)diameter

.953 in. (24 mm)

Specifications

Display:

1.3 x 2.6 in. (33 x 66 mm), 64 x 128 pixels.

Operating Voltage:8 VDC minimum to 32 VDC maximum.

Reversed Polarity:Withstands reversed battery terminal polarity indefinite-ly within operating temperatures.

Operating Temperature:-40 to +85ºC (-40 to185ºF).

Display Viewing Temperature: -40 to +75ºC (-40 to 167ºF)

Storage Temperature:-40 to +85ºC (-40 to185ºF).

Environmental Sealing:IP68, +/- 5 PSI (+/- 34.4 kPa).

Power Supply Operating Current (@ 14 VDC):52 mA minimum; 268 mA maximum (LCD heater on).

CAN BUS:SAE J1939 Compliant.

Case:Polycarbonate / Polyester.

Clamp:Polyester (PBT).

Connectors:6-Pin Deutsch DTO6 Series.

Maximum Panel Thickness:3/8 in. (9.6 mm).

Mounting Hole:2.062 inch (52 mm) in diameter.

Auxiliary Communications (Gage):One (1) RS485 port, MODBUS RTU master, 38.4K baud, N, 8, 1 or 2, half duplex.

Potentiometer Input:1K ohm, 1/4 W

Shipping Weights (all models):1 lb. (450 g.)

Shipping Dimensions (all models):6 x 6 x 6 in. (152 x 152 x 152 mm).

PV100 Dimensions

Page 7: View PDF - Bell Power Systems Inc

specifications

FW MurphyP.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com 03017H Rev. 9-04

PVA20 / PVAA20 Dimensions

Ø 2.324 in. (59 mm)

2.050 in. (52 mm)

0.48 in. (12 mm)

2.430 in. (62 mm)

1.956 in. (50 mm)

2 Push-on Type Plug Connectors

Screw-on Type Mounting Clamp

BACK

FRONT

Gray Area shows Domed lens style

HOLE CUTOUT 1.972 in. (50 mm)

R 0.063 in. (1.6 mm)

0.125 in. (3 mm)

2.062 in. (52 mm)diameter

OR Use a 2.062 in. (52 mm) diameter round hole.

.953 in. (24 mm)

Ø 3.630 in. (92 mm)

2 Push-on type Plug Connectors

Screw-on Type Mounting Clamp

HOLE CUTOUT

BACK

FRONT

3.285 in. (83 mm)

0.125 in. (3 mm)

3.375 in. (86 mm)diameter

2.09 in. (53 mm)

Gray area shows Domed Lens style.

0.48 in. (12 mm)

2.475 in. (63 mm)

3.268 in. (83 mm)

R 0.063 in. (1.6 mm)

1.610 in. (41 mm)

ORUse a 3.375 in. (86 mm) diameter round hole.

Specifications

Power Supply Input Voltage:12/24V (8-32VDC min. & max. voltage)

Power Supply Operating Current: (@ 14 VDC) = PVA20, PVA35: 28 mA minimum; 52 mA maximum.PVAA20: 19 mA minimum; 46 mA maximum.

Backlight Maximum Current (excludes PVAA20): 24 mA.

Input: RS485 MODBUS® RTU data

Output:Analog Readout.

Relay Rated Load (PVAA20):0.5 A, 125 VAC; 1 A, 24 VDC.

Relay Maximum Switching Capacity (PVAA20):62.5 VA, 30W.

Audible Alarm Output (PVAA20):28 VDC, 30 mA max. (current sink).

Temporary Silence Button (PVAA20):Charge transfer technology.

Storage Temperature:-76° to 185°F (-60° to 85°C).

Dial:White numerals over black background.

Indicating Pointer:Stepper motor operation with 270° sweep.

Gage Accuracy:PVA20/35: Better than ±1.0% of scale. PVA35: Better than ±2% of scale.

Environmentally Sealed Enclosure:Sealing: IP68, ±5 psi (±34.4 kPA).Case and Clamp Material: Polyester (PBT).Lens Material: Polycarbonate.Bezel Material: Polyester (PBT).

Maximum Panel Thickness:3/8 in. (9.6 mm).

Mounting Holes: 2.062 inch (52 mm) in diameter.3.375 inch (86 mm) in diameter.

Connectors:6-Pin Deutsch DT06 Series.

PVA35 Dimensions

Page 8: View PDF - Bell Power Systems Inc

flat lens bezel options

03016H Rev. 9-04

AB Bezel Type

A-20 Style Low Profile SAE Style Contemporary Style Low Curved Style

A Bezel Type

AB Bezel Type

B Bezel Type

BB Bezel Type

C Bezel Type

CB Bezel Type

D Bezel Type

DB Bezel Type

A Bezel Type

AB Bezel Type

BB Bezel Type CB Bezel Type DB Bezel Type

A Bezel Type B Bezel Type C Bezel Type D Bezel Type

B Bezel Type

BB Bezel Type

C Bezel Type

CB Bezel Type

D Bezel Type

DB Bezel Type

PVA2

0 Se

ries -

Gag

esPV

A35

Serie

s- T

ach

& S

peed

omet

erPV

AA20

- Au

dibl

e Al

arm

FW MurphyP.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com

Page 9: View PDF - Bell Power Systems Inc

domed lens bezel options

03019H Rev. 9-04

EB Bezel Type E- Bezel StyleContemporary DomedBezel and Lens Style

E Bezel Type

PVA20 Series - GagesPVA35 Series- Tach &

Speedometer

PVAA20 - Audible AlarmE Bezel Type

E Bezel Type

EB Bezel Type

EB Bezel Type

FW MurphyP.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com

1. Domed Bezel

1. Domed Lens

Page 10: View PDF - Bell Power Systems Inc

wire harnesses

03018H Rev. 9-04

Terminating Resistor PVJR

Wire harness PVW-P Wire harness PVW-J Wire harness PVW-J

Wire harness PVW-J

Customer provided wire harness or CAN extension harnesses or power extension harnesses.

External Dimmer Wire 24 inch.

To Engine ECU

To Battery Power

POWERVIEWPV100

PVW

-PH

PVW

-CH

PVA Gage Next PVA Gage

Last PVA Gage or PVAA Audible Alarm

To PVAA Audible Alarm

To optionalexternal device

CAN–SHLD

CAN–HI

CAN–LO

ExternalDimmer

GRND

B+

Relay N.O.

Relay N.C.

Ext. Sonalert

Relay Comm.

Optional PVW-A wire harness (includes terminating resistor)

OR

A B

A B

A B

A B A B

Typical Quick-Connect Diagram

Optional PowerView Wiring Models (PVW)External Wiring Harnesses Model Length DescriptionPVW-CH-72 72 in.(6 ft) PowerView Extension HarnessPVW-CH-144 144 in. (12 ft) PowerView Extension HarnessPVW-CH-240 240 in. (20 ft) PowerView Extension HarnessPVW-CH-360 360 in. (30 ft) PowerView Extension Harness

PVW-PH-72 72 in. (6 ft) Battery Power Extension Harness PVW-PH-144 144 in. (12 ft) Battery Power Extension HarnessPVW-PH-240 240 in. (20 ft) Battery Power Extension HarnessPVW-PH-360 360 in. (30 ft) Battery Power Extension Harness

PVW-CC-24 24 in. PowerView CAN Loose WiringPVW-PC-24 24 in. Battery Power Loose Wiring

PVW-CT CANBUS Tee Harness

Internal Wiring Harnesses Model Length DescriptionPVW-P-12 12 in. PowerView CAN and Power Harness*PVW-P-24 24 in. PowerView CAN and Power Harness*

PVW-PW-30 30 in. CAN and Power Harness w/loose wires*

PVW-J-9 9 in. PowerView Jumper HarnessPVW-J-12 12 in. PowerView Jumper HarnessPVW-J-24 24 in. PowerView Jumper Harness

PVW-A-9 9 in. Audible Alarm Jumper HarnessPVW-A-12 12 in. Audible Alarm Jumper HarnessPVW-A-24 24 in. Audible Alarm Jumper Harness

PVJR Jumper Terminating Resistor

PVW-K-12 12 in. Wiring Kit 24 in. Includes:

(1) PVW-P, qty 1(2) PVW-J, qty 4(3) PVJR

*Includes J1939 CAN 120 ohm resistor.

FW MurphyP.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com

Page 11: View PDF - Bell Power Systems Inc

how to order

03035H Rev 9-04

To Order Your PowerView Module Use This Designation Diagram:

ModelPV100 = PowerView

Blank = StandardGM = For use only on GM

MEFI ECU — General Motors

Model StyleA = Black Overmold Faceplate with Silver Bezel

PV100 – A –

FW MurphyP.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com

To Order Your PowerView Gages Use This Designation Diagram:

Bezel (All Models)Bezel Type (flat lens)

A = A20 (Brushed Silver)AB = A20 (Black)B = Low profile SAE (Brushed Silver)BB = Low profile SAE (Black)C = Contemporary (Brushed Silver)CB = Contemporary (Black)D = Low Curved (Brushed Silver)DB = Low Curved (Black)

Bezel Type (domed lens)E = Contemporary Domed (Brushed Silver)EB = Contemporary Domed (Glossy Black)

Remote GageR1 = Option for a secondgage of identical type onthe gage network. For example: If you arealready using onePVA20-A-100-A, and asecond oil pressure gageis needed, order aPVA20-A-100-A-R1.

Gage Ranges (excludes PVAA20) Available for Gage Functions

100 =100 psi/700 kPa A100 =100% Load @ Current RPM D100 =% Fuel Level J150 =150 psi/1000 kPa (PVA20-A only) A250 =250°F/120°C B, F, G12 =12 VDC C24 =24 VDC C

400 =400psi/28 bar E3000 =3000 RPM T

85 =85 MPH S7B =7 Bar/100 psi A

10B =10 Bar/150 psi A28B =28 Bar/400 psi E

ModelPVA20 = 2 inch size PowerView GagePVA35 = 3-1/2 inch size PowerView Gage

(Tachometer or Speedometer only)

PVAA20 = 2 inch PowerView Audible Alarm

Gage Function (excludes PVAA20)

A = Engine Oil Pressure

B = Coolant Temperature

C = Voltmeter

D = Percent Load @ Current RPM

E = Transmission Oil Pressure

F = Transmission Oil Temperature

G = Engine Oil Temperature

J = Fuel Level

T = Tachometer

S = Speedometer

PVA20 – A – 100 – A – R1

*

*Please see sales bulletins for exact features and specifications.

Page 12: View PDF - Bell Power Systems Inc

MSeries panels

MS-04054H Rev. 9-04

Plug and Go Custom Panels

Plug and Go M310 Panels

Plug and Go M110 Panels

Connecting To Electronic Engines Doesn’t Have To Be Complicated.Now You Can Just "Plug And Go."

Standard Harnesses Adapt All Panels To Most Engine ECUs.

With MurphyLink panels, we’ve made it simple and easy to connect tomodern electronic engines using the SAE J1939 Controller AreaNetwork (CAN). We’ve done the work so you don’t have to.

Our next-generation panels include PowerView, the most advancedJ1939 CAN display system available. You get a large graphical, high-resolution, backlighted LCD screen that provides a clear look insidemodern electronic engines. PowerView displays over 30 standardSAE J1939 parameters, and its diagnostic capabilities include faultcodes with text translations for most common fault conditions.

● Standard harnesses make basic and deluxe panels

interchangeable

● Simple connections for easy installation with minimal training

● Available for most major electronic engines

● Includes Deutsch connectors

● Available in enclosed design or flat panel option

FW MurphyP.O. Box 470248 Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com

Page 13: View PDF - Bell Power Systems Inc

For more information aboutPowerView products, phone (918) 317-4100, fax (918) 317-4266, or visit our website atwww.fwmurphy.com.

Warranty. A two-year limited warranty on materials and workmanship is given with the FW MurphyPowerView products. Details are available on request and are packed with each unit.

CONTROL SYSTEMS & SERVICES DIVISIONP.O. Box 1819; Rosenberg, Texas 77471; USA(281) 633-4500 fax (281) 633-4588 e-mail [email protected]

MURPHY DE MEXICO, S.A. DE C.V.Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P.; México 78384 +52-444-8206264 fax +52-444-8206336Villahermosa Office +52-993-3162117e-mail [email protected]

FRANK W. MURPHY, LTD.Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.+44 1722 410055 fax +44 1722 410088 e-mail [email protected]

MURPHY SWITCH OF CALIFORNIA41343 12th Street WestPalmdale, California 93551-1442; USA(661) 272-4700 fax (661) 947-7570e-mail [email protected]

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

MACQUARRIE CORPORATION1620 Hume HighwayCampbellfield, Vic 3061; Australia +61 3 9358-5555 fax +61 3 9358-5558e-mail [email protected]

FWMurphyP.O. Box 470248Tulsa, Oklahoma 74147 USA (918) 317-4100 fax (918) 317-4266 e-mail [email protected] www.fwmurphy.com

Printed in U.S.A. 04138A Rev. 09-04

MurphyLink is a registered trademark of FWMurphy Company. All other trademarks and service marks used in this document are the property of their respective owners.

REGISTERED