  • (VRF) FULL LINE CATALOGVARIABLE REFRIGERANT FLOW

    Spring 2017 Edition

  • BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution . . . . . . . . . . . . . . . . . . . . . . . 1What is Variable Refrigerant Flow (VRF) . . . . . . . . . . . . . . 1Simultaneous Heating & Cooling . . . . . . . . . . . . . . . . . . . . . 1Bryant VRF Scroll Compressor . . . . . . . . . . . . . . . . . . . . . . . 3High Performance Heat Exchanger . . . . . . . . . . . . . . . . . . . 3Advanced Silent Technology with Fan Blade Design . . . . 3Hinged Electrical and Control Design . . . . . . . . . . . . . . . . . 4Enhanced Defrost Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 4High Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5High Heating Performance . . . . . . . . . . . . . . . . . . . . . . . . . . 5VRF Installation Made Simple . . . . . . . . . . . . . . . . . . . . . . . . 6Heat Recovery Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Heat Pump Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Single-phase Heat Pump Benefits . . . . . . . . . . . . . . . . . . . 11

    VRF OUTDOOR UNITS Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Heat Recovery (3-phase) . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Multi-port Distribution Controller (MDC) . . . . . . . . . . . . 17Heat Pump (Single-phase) . . . . . . . . . . . . . . . . . . . . . . . . . . 18Heat Pump (3-phase) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    VRF INDOOR UNIT Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254-Way Cassette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Compact 4-Way Cassette . . . . . . . . . . . . . . . . . . . . . . . . . . 27High Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Underceiling / Floor Console (Exposed) . . . . . . . . . . . . . . 29Floor Console Recessed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Low Static Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Medium Static Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32High Static Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Vertical AHU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Outside Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    CONTROLS Individual Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Central Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Building Automation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

  • IT TAKES an efficient solutionYou know what your building needs. Zoned comfort, better air quality, energy efficiency, design flexibility and long-term savings. Nothing delivers them all like a Bryant Variable Refrigerant Flow (VRF) system. We utilize a 2-pipe system for both heat pump and heat recovery. Through it, you can power up to 64 independent indoor units, providing precise, energy-efficient comfort control on a zone-by-zone basis. You can cool one room while heating the other or simply provide comfort to only the zones that are in use.

    Bryant VRF Advantages

    WHAT IS VARIABLE REFRIGERANT FLOW (VRF)Bryant VRF systems provide precise, highly efficient comfort control. The name says it all: Variable Refrigerant Flow moves refrigerant to the specific zone that needs to be heated or cooled. Its the ultimate flexibility in HVAC: the refrigerants flow can vary from location to location, delivering just what each zone needs. No more. No less.

    SIMULTANEOUS HEATING & COOLING A simplified 2-pipe design provides heat recovery and flexible refrigerant flow, Bryant VRF makes it possible to heat and cool different zones on a single refrigerant piping system at the same time. This also helps increase efficiency by capturing what would have been wasted energy from one space and returning it to the other as useful energy.

    1

  • Bryant VRF Advantages

    COMPRESSOR Bryant rotates the operating sequence of the outdoor units and individual compressors. By spreading the operating hours evenly, occupants can enjoy balanced, consistent comfort. Inverter-driven compressors eliminate rush currents and on/off power surges as the system adjusts to demands. They also reduce the risk of compressor failure, more common in standard non-Inverter systems. Should there be a failure, the outdoor unit provides greater backup capability, allowing the system to continue to operate and maintain comfort while the faulty compressor is isolated, repaired or addressed.

    ENERGY EFFICIENT You cant build today without making energy efficiency part of the equation. Our VRF systems improve climate control and minimize energy loss by heating and cooling different rooms at the same time. They circulate the minimum amount of refrigerant necessary to satisfy the building load and each individual zone while capturing what would have been wasted energy from one space and returning it to the other as useful energy.

    Coupled with that, outdoor units employ one or more Inverter-driven compressors, and each operating sequence is rotated to balance operating hours and load distribution. This means that the system operates at its most efficient range more often, providing reduced energy consumption, and a more reliable system.

    AN EASIER SIMPLER INSTALLATION Our VRF systems require very little. Theres no need for distribution fans, water pumps and large hydronic pipesor space-consuming maintenance rooms or service shafts; making them easy to install, while freeing up valuable space in the building.

    If youre working with a Bryant VRF specialist or become one yourself, youll find the system is easy to control. The entire system can be run from a central location.

    MORE OPTIONS FOR MORE FLEXIBILITY Every building has different needs, so Bryant gives you a variety of choices. Our VRF products include a smaller equipment footprint, piping lengths up to 3280 ft. and a variety of ducted and ductless indoor unit options. Its a combination that delivers the utmost in design flexibility. Whether its a commercial or large residential application, a single- or multi-floor building, a new build or a retrofit, youll have all the options you need.

    2

  • Bryant VRF Advantages

    BRYANT VRF SCROLL COMPRESSORBryant VRF Inverter-driven compressors can precisely match the buildings cooling and heating demands, mostly operating within the most efficient frequency range, 50 to 80 Hz. With the compressors operating together, theres an increase in long-term durability.

    ASYMMETRIC SCROLL WRAP SYMMETRIC SCROLL WRAP

    3

    ADVANCED SILENT TECHNOLOGY WITH FAN BLADE DESIGNThe unique 3 and 4 blade fan design decrease the running noise and lowers down airflow resistance and vibration. Paired with the DC Inverter compressor, the condenser is extremely quiet with operation as low as 58.4 dB(A).

    HIGH PERFORMANCE HEAT EXCHANGERThe advanced heat exchanger design enlarges the heat-exchange area, decreasing the air resistance while the hydrophilic fins and inner-threaded copper pipes optimize heat exchange efficiency.

  • Bryant VRF Advantages

    HINGED ELECTRICAL AND CONTROL DESIGN

    Max . 150o

    The electric control box can be rotated by a maximum of 150 degrees to make it much easier to dismount and more convenient for pipeline inspection or servicing.

    ENHANCED DEFROST CONTROL

    Hea

    ting

    capa

    city

    Usual defrosting

    t

    Time

    t min

    Intelligent defrosting

    The enhanced defrost control can adjust the defrosting cycle time based on system operating environments to reduce the time the system spends in defrost improving overall heating performance. By feeding hot gas through the bottom row of the outdoor coil we have eliminated the need for basepan heater accessories; improving system reliability.

    4

  • Bryant VRF Advantages

    HIGH EFFICIENCYBryant VRF achieves high efficiency in cooling and heating by utilizing all DC Inverter compressors, all DC fan motors and high-efficiency heat exchangers. The cooling IEER is 24.7, and heating SCHE 30.0.

    BRYANT VRF HR WITH NON-DUCTED INDOOR UNITS UNDER AHRI RATING

    35

    30

    25

    20

    15

    10

    5

    06 Ton 8 Ton 10 Ton 12 Ton 14 Ton 16 Ton 18 Ton 20 Ton 22 Ton 24 Ton 26 Ton 28 Ton

    SCHE IEER

    HIGH HEATING PERFORMANCEThe Bryant VRF system provides heating down to -13 F with up to 70% of the rated heating capacity. This is just one more way we deliver comfort solutions for any indoor space, anytime of the year.

    UP TO 98% OF HEATING CAPACITY AT 5O F

    100%

    90%

    80%

    70%