Page 1: v6 - Daikin AC...VRF IndustRy FIRst! v6.02 Temperature Control individual Cool and Heat setpoints • Temperature control is achieved by individual Cool and Heat Setpoints in Cooling

Take control of your worldv6.02

Page 2: v6 - Daikin AC...VRF IndustRy FIRst! v6.02 Temperature Control individual Cool and Heat setpoints • Temperature control is achieved by individual Cool and Heat Setpoints in Cooling

Intelligent Touch Controller

Centralized and advanCed vrv Control

tenant Billing

anCillary equipment Control

WeB aCCess and alert e-mail

Up to 64 Indoor Unit Groups (128 actual Indoor Units) can be monitored and controlled with individual Cool and Heat Setpoints, Setpoint Range Limitation, Setback Setpoints, and Auto-changeover to meet your expectations and project requirements. Up to 128 Indoor Unit Groups (256 actual Indoor Units) can be monitored and controlled with the addition of the Optional DIII-Net Plus Adapter.

Integrates and/or interlocks sensors, switches, dampers, fans, pumps, and lighting with Daikin Indoor Units.

Allows daily remote monitoring and control with the Web/E-mail Software option that can be accessed via the facility’s Local Area Network or your Internet connection. Sends Error E-mail to mobile device with the optional Web/E-mail Software option.

Determines energy consumption of shared condensing units based upon tenant (Indoor Unit) demand.

Emergency/ Forced Shutdown

Pulse Input

DIII-Net Plus Adapter

PC

Digital Input (DI) Unit

Digital Input/Output(DIO) Unit

Key Card

OccupancySensor

Ancillary Equipment

Damper

energy meterPower Proportional Distribution (PPD) - apportions total outdoor unit power consumption among indoor units with optional PPD software

Centralized and advanced vrv Control

ancillary equipment Control

Web access and alert e-mail

tenant Billing

Detailed & Easy Monitoring and operating your VRV system is easy

Just a touch on the screen brings up icons that make it easy to understand all the information concerning the control of the system. The Intelligent Touch Controller enables an operator to conduct a variety of quick and easy operations, create settings, and access screens to confirm the details set for each Zone or Group.

monitoring and Controlling points/items

On/Off

Operation Mode

Individual Cool and Heat Setpoints

Fan Speed

Airflow Direction

Button Prohibit

Filter Sign Reset

Setpoint Range Limitation (with Min C/H setpoint differential)

Setback Setpoints (with setback recovery differential)

Auto-changeover

Applied Schedule

Zone

Group(Indoor Unit

Group)

• Advancedconfigurationand greater application flexibility with features such as dual setpoints, setback setpoints, setpoint range, and Auto-changeover.

• Allareconfigurableand now available via the web with the Web/ E-mail Software option activation.

Features

List Display

Icon Display

Icon Detail Display

Touch Screen View

Password protection

Monitor screen legend

Display Zone/Groupcondition

Zone ScheduleSet for Zone

Selection of Zone or Group display

System status

Current display view

Individual Zone/Group name

Changeable Zone/Group icons

Selection of Icon, Icon Detail, or List Display

On/Off settings for individual Zone/Group

Configure settings for each Zone/Group

Display settinginformation for each Zone/Group

System setup mode

Current date and time

On/Off for all Indoor Units

v6.02

Ethernet

Page 3: v6 - Daikin AC...VRF IndustRy FIRst! v6.02 Temperature Control individual Cool and Heat setpoints • Temperature control is achieved by individual Cool and Heat Setpoints in Cooling

Cooling on

Heating on

setback setpoint80˚F

setback setpoint 60˚F

space temp.

space temp.

6 a.m.

6 a.m.

5 p.m.

5 p.m.

unit on

unit on

unit off

unit off

Cooling setpointrange limit

Heating setpointrange limit

74˚F

72˚F

setpoint 72˚F

setpoint 70˚F

70˚F

68˚F

Cooling on

Heating on

occupied

occupied

unoccupied

unoccupied

setback period

setback period

setback control de-energizes indoor unit when recovery differential (adjustable) temperature is met

setback control de-energizes indoor unit when recovery differential (adjustable) temperature is met

setbackControl active

setbackControl active

Auto-changeover The Intelligent Touch Controller V6.02 and Auto-changeover switches the Indoor Unit’s mode (Cool or Heat) individually or by Zone according to the room temperature, the setpoint, or by averaging room temperatures and setpoints.

Scheduling• Selectbetweentheindividual7-day,5+2(weekday+weekend),or5+1+1(weekday+Saturday+Sunday) weekly schedule pattern settings

− Up to 8 scheduled events per day

• IndividualoccupiedCoolandHeatSetpoints

− Individual Cool and Heat Setpoints eliminate the need for seasonal scheduling

• AbletoscheduleSetbackCoolandHeatSetpointsduringunoccupiedconditions

− 2 hr override setting available via scheduling

• Repeatableyearlycalendar

− Able to set 40 exception days to the normal schedule

− Set exception days by specific date (January 1) or by day of the week and month (floating holiday) (1st Monday in September)

individual:Groups change based on individual room temperature/setpoint. Good for Heat Recovery system.

Fixed:Entire Zone changes based on room temperature/setpoint of first unit registered in Zone.

averaging:Entire Zone changes based on average room temperature/setpoint of all units registered in Zone.

Changeover Master Unit= Zone

Room temp and Setpoint Included in Changeover Calculation

= Changeover Members

Control zone 1

itC

Control zone 2

Control zone 3

COOL

Individual Cool/Heat Setpoints eliminate the need for seasonal schedule

HEATVRF IndustRy FIRst!

v6.02Temperature Control

individual Cool and Heat setpoints

• TemperaturecontrolisachievedbyindividualCoolandHeatSetpointsinCoolingandHeatingmodes, and Auto-changeover.

setpoint range limitation

• CoolandHeatSetpointrangescanbesetbetween60˚F and 90˚F for occupied operation, with configurable minimum differential between 0˚F-7˚F, or single setpoint mode.

setback control when space is unoccupied • SetbackCoolandHeatSetpointscanbesetbetween40˚F and 95˚F. • Duringunoccupiedperiodswithsetbackenabled,theIndoorUnitisoffandisenergized oncethesetbacksetpointhasbeenreached,andde-energizedbaseduponconfigurable recovery differential (2˚F–7˚F).

new In

V6.0

2

new In

V6.0

2

Page 4: v6 - Daikin AC...VRF IndustRy FIRst! v6.02 Temperature Control individual Cool and Heat setpoints • Temperature control is achieved by individual Cool and Heat Setpoints in Cooling

Web Browser Software (optional)Monitor and control your VRV System via your Internet browser− Expanded web access configurations available for configurable client access − E-mail notification of system and equipment maintenance and/or issues

LAN/Internet

Network Switch/Router

Intelligent Touch Controller Outdoor Unit

Indoor Units

Icon View – Zone / Group List View – Zone / Group

Schedule Settings Scheduling Pattern Change

User’s Computer

Ethernet

Remote Monitoring / Maintenance

*Each Intelligent Touch Controller requires the Web/E-mail Software option for monitoring and control.

Unified Monitoring and Control*

Network/Internet

Property Manager / Engineering

Ancillary Equipment Control• AninterlockfunctionviatheDigitalInput(DI)andDigitalInput/Output(DIO)unitsallowforcontrol

of multiple ancillary units (ERV, lights, fans, dampers, occupancy sensors, etc.). Indoor Unit operation (On/Off, operation mode, setpoint, and remote controller prohibit) can be controlled based upon ancillary unit operation.

• AncillaryequipmentcanbeconfiguredtostandaloneandbecontrolledviatheIntelligentTouchController display or Scheduling function.

Applications• Officeorschoolwheresetbackscheduleisrequired

• Hotelsornursinghomeswhereindividualauto-changeoverisrequired(withVRVHeatRecoverysystem)

• Residentialwithweeklyschedule

• Webaccessforeasymaintenance

• GoodasabackupcontrollerforaBACnet® or LONWORKS®BMSintegration-maintainbasicVRV controlfunctionsintheeventaBMSsystemisnotreadyorinfailure

• Crestron® Interface with HTTP option - Expands control options available to include control and monitoring from a smart phone such as the iPhone® and other wireless interfaces

v6.02

8 Sets of Status input Alarm input

DI Unit

4 Sets of Output Status input Alarm input

DIO Unit

Intelligent Touch Controller

Outdoor Unit Indoor Units

Max 8 Input Channels

Occupancy Sensor

Key Card

DIO Unit

DI Unit

Max 4 I/O Channels Ancillary Equipment

Damper

Page 5: v6 - Daikin AC...VRF IndustRy FIRst! v6.02 Temperature Control individual Cool and Heat setpoints • Temperature control is achieved by individual Cool and Heat Setpoints in Cooling

ModelItem Description

Description

All Daikin Industries locations and subsidaries in Japan have received environmental management system standard ISO 14001 certification.

Daikin Industries, Ltd.Domestic GroupCertificate Number: EC99J2044

Daikin AC (Americas), Inc.1645 Wallace Drive, Suite 110Carrollton, TX 75006 [email protected]

PCITUSE11-12C

The air conditioners manufactured by Daikin Industries have received ISO 9000 series certification for quality assurance.

Certificate Numbers:(ISO 9001) JMI-0107 (ISO 9001) JQA-1452

About ISO 14001

ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by the internationally accredited compliance organization as having an appropriate program of environmental protection and activities to meet the requirements of ISO 14001.

Dealer Information

Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without incurring any obligations.

* Pulse input from KWh meter requirements: 1 pulse to 1KWh or 10KWh. Pulse width must be between 40-400 msec. Non voltage, normally open semi-conductor type.** The Power Proportional Distribution (PPD) feature supplies the user with a reasonably calculated apportionment of the total power consumption by the Daikin air-conditioning system. Because input to the PPD includes measured pulses in the refrigerant system and because the air-conditioning system includes a number of variables, including operating temperatures and pressures, piping length, heat exchange rates and others, no meter-type apportionment of individual users’ consumption can be made. However, the PPD feature provides an apportionment methodology that uses highly advanced technology applied to the many variables in an air-conditioning system.

Intelligent Touch Controller DIII-Net Plus Adapter

Surrounding temperature

Humidity

H x W x D (inch)

Size/Number of pixels/Number of colors

Touch panel input

Maximum number of Indoor Units

Maximum number of Outdoor Units

F1F2 (Daikin DIII-Net communications)

10BASE-T (Ethernet communication)

PCMCIA slot (for flash memory card)

RS232C (for DCS601A72 connection)

DI (Digital input for forced shutdown)

PI (Pulse input) *

Model

Power supply

Power consumption

Operating conditions

Dimensions

LCD touch panel

Accessible units

Interfaces

Input terminals

EMC certification

Option Software

Unification Adapter

Installation box

Interface Adapters

Digital input (DI) unit

Digital input/output (DIO) unit

DCS002A71

DCS004A71

DCS007A51

DCS302A72

KJB411A

KRP928BB2S

DEC101A51-US2

DEC102A51-US2

Power Proportional Distribution (PPD)**

Web/E-mail Software (Java plugin - JSE 5.0 or later is required)

HTTP Interface software (for Home Automation System Integration)

Unified Start / Stop through outside signal

For wall mounted installation of Intelligent Touch Controller

For connection to Daikin Mini-Split system (connect to Indoor Unit)

8 sets of Operation status input and Alarm input

4 sets of Control output, Operation status input and Alarm input

DCS601C71

AC 24V 60Hz

10 W maximum (20VA or more transformer)

32˚ F to 104˚ F

Less than 85% RH (non condensing)

5 25/32 x 9 1/16 x 4 7/32

5.7 inches/QVGA 320x240/4,096

10 bit encoded analog input

64 addressed Indoor Unit Groups(maximum 128 actual Indoor Units)

10

1

1(RJ-45)

1

1 (Dsub-9 Male)

1

3

FCC Part 15 Subpart B Class A

DCS601A72

AC 24V 60Hz

5 W maximum (20 VA or more transformer)

14˚ F to 104˚ F

20% to 90% RH (non condensing)

7 15/32 x 6 3/16 x 1 21/32

-

-

64 addressed Indoor Unit Groups(maximum 128 actual Indoor Units)

10

1

-

-

1 (RJ-45) 32 ft cable included

-

3

FCC Part 15 Subpart B Class A

Configuration and engineering for each project is necessary.

Model

Options for Intelligent Touch Controller

Specifications

Other OptionsItem

v6.02

© 2011 Daikin Industries, Limited.

Daikin®, Daikin® AC, Absolute Comfort, and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, Limited. LonWorks® and LON® are registered trademarks of Echelon Corporation. BACnet® is a Data Communications Protocol for Building Automation and Control Networks, developed under the auspices of the American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE).