![Page 1: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/1.jpg)
Understanding Light Curing Improved Clinical Success
Howard E. Strassler, DMD, FADM, FAGD
Professor, Division of Operative Dentistry
University of Maryland School of Dentistry
![Page 2: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/2.jpg)
Special thank you to
Richard Price, DDS, MSc, PhD
Professor, Prosthodontics
& Biomedical Engineering
![Page 3: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/3.jpg)
Disclosure
Advisory Board BlueLight Analytics
San Francisco Giants fan
Supporter of Baltimore Orioles
![Page 4: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/4.jpg)
What are we light curing?
Adhesives
Restorative composites
Sealants
Ceramic veneers
Ceramic inlays/onlays
Fiber posts
Bases-liners
Tray materials
Denture base materials
Prosthodontic provisional materials
Desensitizing agents
Bleaching agents
![Page 5: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/5.jpg)
Majority of direct restorations placed Composite Resins
• 130,054 General Dentists in US
• >122 million direct resin restorations
• Plus veneers + orthodontics
ADA 2005-6 Survey of Dental Services
All used light curing!
![Page 6: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/6.jpg)
“Despite steady progress in learning how to better formulate and cure, or harden, dental composites… Studies have shown that dental resin composites have an average replacement time of 5.7 years due to secondary decay and fracture of the restoration.”
National Institute for Dental and Craniofacial Research, 2009
![Page 7: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/7.jpg)
Understanding Light Curing
![Page 8: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/8.jpg)
Price RB, Fahey J, Felix DM. Knoop hardness mapping used to compare the efficacy of LED, QTH and PAC curing lights. Oper Dent. 2010; 34:58-68. Sharkey S, Ray N, Burke F, Ziada H, Hannigan A. Surface hardness of light activated composites cured by two different visible light sources: an in vitro study. Quintessence Int. 2001; 32:401-5. Rueggeberg FA, Caughman WF, Curtis JW Jr. Effect of light intensity and exposure duration on cure of resin composite. Oper Dent. 1994; 19:26-32. Malhotra N, Mala K. Light curing considerations for resin-based composite materials: a review. Part I. Compend Contin Dent Educ. 2010; 31:498-505. Suh BI, Feng L, Wang YH, et al. The effect of the pulse-delay cure technique on residual strain in composites. Compend Contin Dent Educ (Special Issue); 1999; 20(2):4-12 Duke ES, Light-emitting diodes in composite resin polymerization. Compend Contin Dent Educ. 2001; 22:722-5. Yap AU, Wong NY, Siow KS. Composite cure and shrinkage associated with high intensity curing light. Oper Dent. 2003; 28:357-64. Schattenberg A, Lichtenberg D, Stender E, Willershausen B, et al. Minimal exposure time of different LED-curing devices. Dent Mater. 2008; 24:1043-9. Fan PL, Schumacher RM, Azzolin K, Gerary R, et al. Curing-light intensity and depth of cure of resin based composites tested according to international standards. J Am Dent Assoc. 2002; 133:429-34. Yap AU, Seneviratne C. Influence of light energy density on effectiveness of composite cure. Oper Dent. 2001; 26:460-6. Calheiros FC, Kawano Y, Stansbury JW, Braga RR. Influence of radiant exposure on contraction stress, degree of conversion and mechanical properties of resin composites. Dent Mater. 2006; 22:799-803. Judy RH, Dunn WJ, Patel AB, Swanson T. Effective single-charge end point of cordless light-emitting diode light-curing units. Am J Orthod Dentofacial Orthop. 2006; 130:378-84. Felix D, Price RB. The importance of stating disaggregated irradiance values from curing lights. J Dent Res (IADR abstracts). 2011; 90:abstract no. 260. Caughman WF, Rueggeberg FA, Curtis JW Jr. Clinical guidelines for photocuring restorative resins. J Am Dent Assoc. 1995; 126:1280-6. Strassler HE. Cure depths compared with LED and other curing lights. J Dent Res (Special Issue, AADR abstracts). 2003; Spectral curing lights and evolving technology. ADA Prof Prod Rev. 2009; 4(4):1-12. Xu X, Sandras D, Burgess JO. Shear bond strength with increasing light-guide distance from dentin. J Esthet Restor Den. t 2006; 18:19-28. Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent. 2000; 12:320-7. Felix CA, Price RB. The effect of distance from light source on light intensity from curing lights. J Adhes Dent. 2003; 5:283-91. Hinoura K, Miyazaki M, Onose H. Effect of irradiation time to light-cured resin composite on dentin bond strength. Am J Dent. 1991; 4:273-6. Rueggeberg FA, Jordan D. Light tip distance and cure of resin composite J Dent Res (Special Issue A), 1992; 71:188 abstract. Felix CA, Price RB. Effect of distance on power density from curing lights. JDR 85 (Special Issue B) IADR abstracts. 2006; abstract no. 2486. Pilo R, Oelgresser D, Cardash HS. A survey of output intensity and potential depth of cure among light-curing units in clinical use. J Dent. 1999; 27:235-41. Pires JA Cvitko E, Denehy GE, Swift EJ. Effects of curing tip distance on light intensity and composite resin microhardness. Quintessence Int. 1993; 24:517-21. Price RBT, McLeod ME, Felix CM. Quantifying light energy delivered to a Class I restoration. J Can Dent Assoc. 2010; 76(2):a23. resin proximal contact. Oral Health J. August 2010; 60-73. Rueggeberg F, Mutluay MM, Price RBT, Felix CM. Efficacy of a training device for increasing curing energy delivery. J Dent Res. 2010; 89(Special Issue B, Barcelona IADR, research abstracts): abstract no. 4079 McAndrew R, Lynch CD, Pavli M, Bannon A, et al. Summary of: the effect of disposable infection control barriers and physical damage on the power output of light curing units and light curing tips. Brit Dent J. 2011; 210:E12. Price RB, Rueggeberg FA, Labrie D, Felix CM. Irradiance uniformity and distribution from light curing units. J Esthet Restor Dent. 2010; 22:86-101.
Tested as Vitrebond Powder/Liquid
Science of light curing
![Page 9: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/9.jpg)
Composite Use
• 122,666,950 direct resin restorations a year ADA 2005-6
• One third of dentists have eliminated amalgam. Christensen, Dental Economics Jan 2011
• In the last 12 months in the U.S., the ratio of
composite placed compared to amalgam placed
was two Class II composites for every one Class
II amalgam. Limoli and Associates, Oct 2010
![Page 10: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/10.jpg)
Did you know?
• 122,666,950 direct resin restorations a year: ADA 2005-6
• 50 working weeks a year x 5 days = 250 working days
• 490,667 resins a day
• 490,667 times a curing light was used
• 490,667 times @ $200 each
• $98,133,560 a day in the US ALONE
• $24.5 BILLION a YEAR
![Page 11: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/11.jpg)
Light-curing… so easy a caveman can do it!
![Page 12: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/12.jpg)
The Problem
Process of “light-curing” is
treated with “little regard” to the exacting science it really is.
“Too easy” and minimal attempts seem to produce an acceptably “hard” restoration.
![Page 13: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/13.jpg)
Understanding the challenge
Teach students-clinicians how to use their light properly and what affects the extent of cure of THEIR RESTORATIONS :
What “spectral output” of the light means
What are the “spectral needs” of the resin
What is the difference between irradiance and energy density
How exposure duration and spectral delivery affect final restoration cure
![Page 14: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/14.jpg)
The Problem: not curing composite completely
• Lower bond strength
• Increased microleakage
• Increased recurrent caries
• Increased staining-color changes
• Increased wear
Premature restoration failure!
Uncured Resin
Tooth
![Page 15: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/15.jpg)
Not all curing lights are the same
Understanding
The Differences
![Page 16: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/16.jpg)
Power = mWatts
How much energy- what type of energy?
![Page 17: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/17.jpg)
Irradiance (Power/Unit Area) mW/cm2
![Page 18: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/18.jpg)
Irradiance 1735 mW/cm2
0
2
4
6
8
370 390 410 430 450 470 490 510 530
Wavelength (nm)
Abso
lute
Irra
dian
ce (m
W/n
m/c
m2 )
Spectral Radiant Power mWatts/nm
![Page 19: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/19.jpg)
Understanding
Power: mWatts
Irradiance: (Power/Unit Area) mW/cm2
Spectral Radiant Power: mWatts/nm
Energy Density = Irradiance x Time: 8 - 16 J/cm2
![Page 20: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/20.jpg)
MARC (BlueLight Analytics)
BlueLight makes MARC™− Managing Accurate Resin Curing.
MARC™ was invented by Dr. Richard Price and his research associate, Chris Felix, at Dalhousie University.
MARC™ is the first and only scientifically accurate, clinically relevant and easy-to-use energy measurement system for measuring what resin actually receives.
![Page 21: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/21.jpg)
Consistent calibration enables apples:apples comparisons
Who is MARC™?
Scientifically accurate, clinically relevant
& easy-to-use
MARC™ Patient Simulator
quantifies energy delivery to resin
![Page 22: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/22.jpg)
LIGHT SPECTRUM
![Page 23: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/23.jpg)
LIGHT SPECTRUM
Irradiance = 1,200 mW/cm²
![Page 24: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/24.jpg)
Irradiance not uniform
What is the beam profile?
Price, Rueggeberg et al. J Esthetic and Restorative Dentistry 2010
5,834 mW/cm2 388 mW/cm2
1200 mW/cm2
![Page 25: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/25.jpg)
Detects uneven beam distribution
hot spots-cold spots
![Page 26: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/26.jpg)
Operator technique evaluation
Typodont head with detectors in teeth measure
light received
![Page 27: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/27.jpg)
Bottom line…
How do we make the science relevant and create value during a student’s/clinician’s education?
![Page 28: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/28.jpg)
For a clinical procedure light curing = 15-60 sec
![Page 29: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/29.jpg)
Understanding leads to improved clinical success
Light energy matters!
![Page 30: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/30.jpg)
Safety concerns
![Page 31: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/31.jpg)
Safety concerns
![Page 32: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/32.jpg)
![Page 33: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/33.jpg)
![Page 34: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/34.jpg)
Survivability Amalgam vs Composite
![Page 35: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/35.jpg)
![Page 36: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/36.jpg)
Effect of Distance from the Light
Guide on the Irradiance Received
Felix CA, Price RB. Effect of Distance on Power Density from Curing Lights. Journal of dental research 2006;85:abstract 2486 (www.dentalresearch.org).
![Page 37: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/37.jpg)
When curing adhesives in deep proximal boxes with quartz halogen light (600 mw/cm2) curing time should be increased to 40-60 seconds to ensure optimal polymerization
Xu X, Sandras D, Burgess JO. Shear bond strength with increasing light-guide distance
from dentin. J Esthet Restor Dent 2006
![Page 38: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/38.jpg)
To maximize the energy delivered, the operator should wear eye protection, should watch what he or she is doing and should hold the light both close to and perpendicular to the restoration.
Price RB, McLeod ME, Felix C Quantifying light energy delivered to a Class I restoration J Can Dent Assoc 2010
![Page 39: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/39.jpg)
Where is the light relative to what it is curing?
![Page 40: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/40.jpg)
600 mw/cm2
700 mw/cm2
800 mw/cm2
1000 mw/cm2
1200 mw/cm2
1400 mw/cm2
![Page 41: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/41.jpg)
370 mw/cm2
450 mw/cm2
600 mw/cm2
800 mw/cm2
900 mw/cm2
1000 mw/cm2
![Page 42: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/42.jpg)
Orientation of the Light
**Right angle **Close to the tooth as is possible
Matrix band moves The light further away!
![Page 43: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/43.jpg)
Mis-Orientation of the Light
Note the height of the matrix
![Page 44: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/44.jpg)
Lights not working optimally
![Page 45: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/45.jpg)
MARC Scientifically accurate- clinically relevant device. Measures: Irradiance Spectral emission Energy values
![Page 46: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/46.jpg)
Operator technique
MARC for light curing training
![Page 47: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/47.jpg)
Good light curing habits CORE
Curing Light
Operator Technique
Restoration (location, depth, size, opening)
Energy Requirement
![Page 48: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/48.jpg)
Know your Curing light
![Page 49: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/49.jpg)
37 Operators Same Light, Same Tooth, Same Time
Optimal is 8.0 J/cm² Range from 0.9 – 7.2 J/cm² Average was 4.1 J/cm²
![Page 50: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/50.jpg)
Teaching and Evaluating Light Curing
• NOT looking, NOT stabilizing,
• NOT wearing eye protection!
Wearing eye protection,
looking, stabilizing!
Before Instruction After Instruction
![Page 51: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/51.jpg)
After Group Instruction
Optimal is 8.0 J/cm² Range from 5.8 – 7.6 J/cm² Average was 6.7 J/cm²
![Page 52: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/52.jpg)
Operator controlled Light tip diameter of 7.5 mm
Sealant on molar- 2 cycles (overlapping tip)
Occlusal Class I- 2 cycles (overlapping tip)
![Page 53: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/53.jpg)
Class I or II premolar- 1 cycle no overlap needed unless the premolar is larger than normal
Class II molar- 2 cycles (overlapping tip)
![Page 54: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/54.jpg)
Facial of a maxillary central incisor two or four cycles with overlap
Facial veneer • Direct composite
• Porcelain veneer
Class IV
Light cure facial and lingual
A maxillary lateral incisor two cycles
Curing porcelain veneers
4 cycles w/ overlap
![Page 55: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/55.jpg)
Negative effects-Restoration Light angulation-Light movement
A 30°angle can reduce energy delivery by 26%
![Page 56: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/56.jpg)
Change the angulation Change the cure
TOP TOP
![Page 57: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/57.jpg)
Energy requirement
Power: mWatts
Irradiance: (Power/Unit Area) mW/cm2
Spectral Radiant Power: mWatts/nm
Energy Density = Irradiance x Time: 8 - 16 J/cm2
![Page 58: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/58.jpg)
7 Steps to Ensure Better Light Curing
1. Wear orange glasses (blue light blocking) for safety and so you can watch what you are doing
2. Re-position the patient so you can easily see the restoration and access it with the curing light
3. Position yourself comfortably so you can stabilize the curing light directly over the preparation
![Page 59: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/59.jpg)
7 Steps to Ensure Better Light Curing
4. Adjust the light guide so you can operate the light comfortably. Clean the tip as needed.
5. Stabilize the curing light so the beam is perpendicular to the surface of the resin
6. Begin curing 1mm away from resin and then move as close as possible after 1 second
7. Air-cool or wait between each curing cycle; test the temperature rise from the light on the back of your hand.
![Page 60: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/60.jpg)
Understanding leads to improved clinical success
Light energy matters!
![Page 61: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/61.jpg)
BLUMINESENCE
![Page 62: Understanding Light Curing Improved Clinical Success...Price RB, Derand T, Sedarous M, Andreou P, et al. Effect of distance on the power density from two light guides. J Esthet Dent](https://reader036.vdocuments.us/reader036/viewer/2022071107/5fe21632fcc8c874cc3fb696/html5/thumbnails/62.jpg)