tube laser alignment system georg gassner. 2 delta undulator project tube laser alignment system...
TRANSCRIPT
![Page 1: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/1.jpg)
Tube Laser Alignment System
Georg Gassner
![Page 2: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/2.jpg)
2
Delta Undulator Project
Tube Laser Alignment SystemSLAC, December 11th 2012
Period 32 mm, Length 3.2mGap (bore) 6.4mm PM material NdFeB, grade N40UH
VacuumChamber ID 5.0mm
![Page 3: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/3.jpg)
3
Alignment Scope
• Determine the x- and y- location of a Hall probe assembly at different z-locations inside the vacuum tube allowing simultaneous position and magnetic measurement.
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 4: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/4.jpg)
4
Concept: x-Position
Tube Laser Alignment SystemSLAC, December 11th 2012
CCD Camera
Retroreflector
Laser
Beam Splitter
a)
CCD Camera
Laser
Beam Splitter
Retroreflector moved by Δx
2Δx
2Δx
b)
Δx
![Page 5: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/5.jpg)
5
Concept: x-y-Position
• Incoming beam: Δx
Δy
• Outgoing beam: -Δx
-Δy
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 6: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/6.jpg)
6
We already use a laser and a retroreflector => replace laser head with interferometer laser and we get distance.
Concept: z-Position
Tube Laser Alignment SystemSLAC, December 11th 2012
CCD Camera
RetroreflectorLaser Head
Interferometer
Beam Splitter
Receiver
![Page 7: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/7.jpg)
7
Prism cut from solid
1.5” CCR with
diamond core drill
Retroreflector (1)
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 8: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/8.jpg)
8
Retroreflector (2)
Tube Laser Alignment SystemSLAC, December 11th 2012
- Prism Ø 4.5mm
- Prism and Hall Probe might not be
centered => roll stability important
(carbon fiber tube pusher system)
![Page 9: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/9.jpg)
9
Laser - Hardware
• Agilent 5517B Laser Head– Helium-Neon (632nm), Continuous wave – Beam diameter 6mm – Beam divergence ~0.15mrad
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 10: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/10.jpg)
10
Laser - Beam Size Reduction
Tube Laser Alignment SystemSLAC, December 11th 2012
d1=6mm d2=2mm
1=0.15mrad2=0.45mrad
f1=f2
![Page 11: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/11.jpg)
11
Laser - Beam Focusing
Tube Laser Alignment SystemSLAC, December 11th 2012
• To move the waist of the laser beam out, add focusing lens or move one of the lenses
3
waist
![Page 12: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/12.jpg)
12
Laser Positional Stability
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 13: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/13.jpg)
13
CCD Image
• Point Grey - FL2-20S4M-C– 1624x1224 pixel (~7x5mm)– 4.4µm pixel size
• Natural Density Filter (OD=2) to protect CCD
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 14: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/14.jpg)
14
CCD Images
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 15: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/15.jpg)
15
Image Processing (1)
• Cross Correlation of two images =>DX, DY
Tube Laser Alignment SystemSLAC, December 11th 2012
Manuel Guizar-Sicairos, Samuel T. Thurman, and James R. Fienup, "Efficient subpixel image registration algorithms," Opt. Lett. 33, 156-158 (2008)
![Page 16: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/16.jpg)
16
Image Processing (2)
Tube Laser Alignment SystemSLAC, December 11th 2012
DY=0.4 pixel
DX=-0.2 pixel
![Page 17: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/17.jpg)
17
Measurement System (1)
Tube Laser Alignment SystemSLAC, December 11th 2012
CCD Camera
3.2m vacuum tube
Retroreflector
Laser Head
Mirr
or
Interferometer
Beam Splitter
Receiver
Focusing Lenses Ø
4.8m
m
Mirr
or
Hall Probe
![Page 18: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/18.jpg)
18
Measurement System (2)
Tube Laser Alignment SystemSLAC, December 11th 2012
![Page 19: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/19.jpg)
19
Results – Retroreflector Position
Tube Laser Alignment SystemSLAC, December 11th 2012
• Move the retroreflector from 0-3000mm through the vacuum chamber and back
![Page 20: Tube Laser Alignment System Georg Gassner. 2 Delta Undulator Project Tube Laser Alignment System SLAC, December 11 th 2012 Period 32 mm, Length 3.2m Gap](https://reader035.vdocuments.us/reader035/viewer/2022070409/56649e8b5503460f94b907b5/html5/thumbnails/20.jpg)
20
Summary
• First tests indicate that sub 50µm accuracy is achievable.
• Can be triggered together with magnetic measurements.
• Effects of atmosphere need further investigation especially when system is moving.
Tube Laser Alignment SystemSLAC, December 11th 2012