tssr flexi bsc bsc3i_sample old version
TRANSCRIPT
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
1/27
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
2/27
Version 1-1 enDN03321824
Available to NSN business partners 2 (27)
9.5 Existing Tray Cable ......................................................................................................... 249.6 Propose New Space for Equipment (Marking) ................................................................ 259.7 Propose New Space for DDF (Marking) .......................................................................... 269.8 Propose New Tray if requered ........................................................................................ 27
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
3/27
Version 1-1 enDN03321824
Available to NSN business partners 3 (27)
PURPOSE OF DOCUMENT
This document describes the conditions on the site at the time of the survey anddefines the needed changes. It also defines who is responsible for the works to bedone and the schedule for the works.
1. SCOPE
This report covers the Core networks equipment installation plan (FLEXI BSC,BSC3i, TCSM)
2. RESPONSIBILITIES
Fill in the responsible parties in the table below.
See also SoR list in the supply contract.
Function Company Name Present
Site Planning NSN Agung Fakih
Construction Works -
Electrical Works -
Telecom Installation NSN Deky Prasetyo
Acceptance
3. SITE INFORMATION
Site Name: TTC Sudiang Site ID: UPDxxx
Street address: Jl Perintis Kemerdekaan No 18, Makassar , Sulawesi Selatan
Building type: Owned Permanent Building
Readyness Under construction Ready
Road conditions: Asphalt, good
Guarded: Yes No Permit needed
Keys and access /contact person (Name)
Yulius Heri
Title / task No Supervisor Tsel Sulselbar
Phone / HP no: 0811410007Other contact persons: Satria / 0811468884
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
4/27
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
5/27
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
6/27
Version 1-1 enDN03321824
Available to NSN business partners 6 (27)
4.3.2 Space Available
ElementName
QTYpcs
Width[mm]
/psc
Depth[mm]
/psc
Height[mm]
/psc
Floorload
[kg/m2]
Comments
Flexi BSC 2 1200 900 2000
TCSM 3i 4 1200 900 2000 Need Renovation
Total
4.3.3 Space Requerement for New Equipment
Element
Name
QTY
pcs
Width
[mm]
/psc
Depth
[mm]
/psc
Height
[mm]
/psc
Floorload
[kg/m2]
Comments
Flexi BSC 2 1200 900 2000TCSM 3i 4 1200 900 2000
Total
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
7/27
Version 1-1 enDN03321824
Available to NSN business partners 7 (27)
4.4 Power requirements
Network element Power (W)/pcs Voltage (V) Breakers (A)
Flexi BSC 4000 48 63
TCSM 3i 5000 48 80
4.3.4 Grounding
Grounding busbar Existing New needed
Cable Tipe NYAF Green Yellow 25mm
Lenght 30 MComments
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
8/27
Version 1-1 enDN03321824
Available to NSN business partners 8 (27)
4.3.5 AC distribution
AC voltage Phases: 1 3 Nominal: 220 V Main fuse: 50 AFluctuation 5 % Min: 210 V Max: 225 V
Comments:
Distribution board Yes No New Fuses: pcs Value: A
Fuses: pcs Value: A
Fuses: pcs Value: A
Fuses: pcs Value: A
Fuses: pcs Value: A
Fuses: pcs Value: A
Wall plugs New: pcs Type: Fuse: A
UPS Voltage: VAC Power: W Fuse: A
Output Fuses: pcs Value: A
Output Fuses: pcs Value: A
Inverter Input: V Power: W Fuse: A
Output: V Fuses: pcs Value: A
Output Fuses: pcs Value: A
Cable Type for Rect
Cable Lenght to Rect
Comments: No need new Rectifier
4.3.6 DC distribution
Rectifier Phases in: 1 3 Main fuse(s): 10 x 3 A
Vendor: Hariff Voltage: 54 V Current: 40 A
Modul : 8 x 20 A Battery : 4 Bank x 100 Ah
Usage : Existing Propose New
DC Distribution panel: 4 Fuses: 2 pcs Value: 80A Not Used
4 Fuses: 2 pcs Value: 63A Not Used
6 Fuses: 6 pcs Value: 16A Used
Fuses: - pcs Value:A Not Used
Cable Type to Equip NYAF 25mm Blue and BlackCable Lenght to Equip 45 Meter per row
Comments:
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
9/27
Version 1-1 enDN03321824
Available to NSN business partners 9 (27)
4.4 Air conditioning
Room equipped with: Yes No New Comments:Exhaust fan
Dust filter
Ventilation fan
Heater
Air coditioner Need Additiona 2x2,5 PK
Cooling capacity 5000 W
4.5 PCM Connection
Result
PCM Type PCM 30 and STM-1
PCM Conector CNIB
Lenght fr Eq to DDF 30 M
Lenght fr DDF to DDF 50 M
T-Line 50 M
Optic Type LC-SC Singgle Mode Duplex
Lenght Optic 70 M per Row
LAN Cable Type CAT 6
Lenght LAN Cable 40 Per Row
Comments:
4.6 Additional Info: Tower Space
Result
Tower Type(Nameplate) SST
Hight (Nameplate) 72 MMax Load (Nameplate) 6 GSM Ant, 3 Parabola 0,5m, 2 Parabola 1m
Curent Load 6 GSM Ant, 3 Parabola 0,5m, 2 Parabola 1m
Avalaible space In Leg A betwen 50-60 meter hight
Comments: Need SDA
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
10/27
Version 1-1 enDN03321824
Available to NSN business partners 10 (27)
5. FLOOR PLAN
DRAWING 1:
DRAWING OF:
1 SQUARE CORRESPOND TO: m SCALE:
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
11/27
Version 1-1 enDN03321824
Available to NSN business partners 11 (27)
5.1 Control room
DRAWING 3:
DRAWING OF:
1 SQUARE CORRESPOND TO: m SCALE:
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
12/27
Version 1-1 enDN03321824
Available to NSN business partners 12 (27)
5.2 example layout
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
13/27
Version 1-1 enDN03321824
Available to NSN business partners 13 (27)
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
14/27
Version 1-1 enDN03321824
Available to NSN business partners 14 (27)
6.
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
15/27
Version 1-1 enDN03321824
Available to NSN business partners 15 (27)
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
16/27
Version 1-1 enDN03321824
Available to NSN business partners 16 (27)
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
17/27
Version 1-1 enDN03321824
Available to NSN business partners 17 (27)
TELECOM INSTALLATION MATERIAL
Item Descriptions Responsibility
Power system
Pcm cables
AC cables
DC cables
Groundingcables
Lan cables
Fibre opticcables
DDF
Alarms
Floor rails
Other
1
.
.
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
18/27
Version 1-1 enDN03321824
Available to NSN business partners 18 (27)
7. VERSION HISTORY
Version Date approved Version history1-2 24.01.11 Second version
8. APPENDICES
List all available site specific documents below.
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
19/27
Version 1-1 enDN03321824
Available to NSN business partners 19 (27)
9. PHOTO SITE SURVEY
9.1 Site Photo & access
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
20/27
Version 1-1 enDN03321824
Available to NSN business partners 20 (27)
9.2 Access to Equipment Room
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
21/27
Version 1-1 enDN03321824
Available to NSN business partners 21 (27)
9.3 Existing Equpment
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
22/27
Version 1-1 enDN03321824
Available to NSN business partners 22 (27)
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
23/27
Version 1-1 enDN03321824
Available to NSN business partners 23 (27)
9.4 Existing DDF
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
24/27
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
25/27
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
26/27
Version 1-1 enDN03321824
Available to NSN business partners 26 (27)
9.7 Propose New Space for DDF (Marking)
-
8/6/2019 Tssr Flexi Bsc Bsc3i_sample Old Version
27/27
V i 1 1 A il bl t NSN b i t 27 (27)
9.8 Propose New Tray if requered