training course supercool 1000 level 1 course #p0131
TRANSCRIPT
Training CourseSuperCool 1000
Level 1
Course #P0131
1000 Level 1
Contents
Module 1: Introduction Module 2: Inputs and Outputs Module 3: Features Exam
1000 Level 1
M1 Tº 72.0 ºFPr. Act: 12345675.4
Manual switch for mist
Rapid-access function keys
LCD display for ease of
programming
LED displayreadable at a distance
Pilot lights indicate
status of controller outputs
1000 Level 1
System• Controls the operation of a
high pressure nozzle system by keeping track of humidity and temperature levels.
• The high pressure nozzle system is the one sold by Victoria Equipment.
• Controls stir fans.• Dairy cows are the main
application. It can also be used for poultry and hog production.
Click on image to view video.
1000 Level 1
What the Client Gets• Controller;• 1 temperature probe;• Contactor box for pump;• Instruction manual / wiring diagram.
Product Options• Up to 3 relative humidity sensors;• Indoor or outdoor temperature probes;• Valve;• Pressure switch;• Water meter;• Configuration module;• Comlink-1 for communications (Bridge)
1000 Level 1
Module 2: Controller Inputs and Outputs
1000 Level 1
Inputs and Outputs• 6 x indoor Tº probes• 1 x outdoor Tº probe• 3 x indoor relative
humidity sensors• 1 x water meter• 1 pressure switch
• 1 mist output– 1 pump– 1 mist valve– 1 drain valve
• 3 fan groups.
1000 Level 1
Input: Relative Humidity Sensors
• You can select sensors to use.• Allows for various strategies:
– Misting:• Compensation on pump operating
times;• Stop pump if RH too high.
– Operation of fan groups according to RH level
• History record over 7 days for minimum and maximum values.
1000 Level 1
Output: Mist
• Operates according to 4 intensity levels. For each level, user must indicate:– Start and stop temperature;– Timer settings.
• For example:
Intensity
1000 Level 1
Output: Mist (cont’d)
• Depending on RH level, controller will modify timer operating times in 2 ways:– Humidity lower than comfort zone: Time Off is decreased– Humidity higher than comfort zone: Time On is decreased
RH Comfort Zone
No compensation
50% = % Time Off
Current
Max Compensated
50% 60% 80% 90%
Low RH set-point High RH set-point
50% = % Time On
%RH
Current
Max Compensated
Pump will stop fora shorter period
Pump will operate for a shorter period
1000 Level 1
Output: Mist (cont’d)
• Mist operation can be shut off:– If RH level too high;– During the night.
• Mist can be activated if RH too low (dust control)