tpo drains, scuppers & roof edge
DESCRIPTION
TPO Drains, Scuppers & Roof Edge. Roof Drain and Overflow. Properly Sloped Drain and Overflow. What’s Wrong?. Roof Drain Tips. All drain bolts must be in place and tight. Firestone Waterblock must be present between the base of the drain and the membrane. Rule of Thumb: 1 tube per drain. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/1.jpg)
![Page 2: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/2.jpg)
TPODrains, Scuppers & Roof Edge
![Page 3: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/3.jpg)
Roof Drain and Overflow
![Page 4: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/4.jpg)
Properly Sloped Drain and Overflow
![Page 5: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/5.jpg)
What’s Wrong?
![Page 6: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/6.jpg)
Roof Drain Tips
• All drain bolts must be in place and tight.
• Firestone Waterblock must be present between the base of the drain and the membrane. Rule of Thumb: 1 tube per drain.
• Slope should not exceed 1”:12” for standard UltraPly TPO.
• Field seams within 9” require a target patch.
• Field seams within 9”-18” must be stripped in with Firestone 5” QuickSeam Flashing.
• Hole in membrane should extend a minimum of ½” beyond the clamping ring and should NOT be smaller than the diameter of the drain pipe.
![Page 7: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/7.jpg)
Scupper Steps 1 & 2
![Page 8: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/8.jpg)
Scupper Steps 3 & 4
![Page 9: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/9.jpg)
How many things are wrong?
“Scupper”
Lower Roof Section
![Page 10: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/10.jpg)
Scupper Tips
• Use Single-Ply QuickPrime Primer to clean and prime all surfaces where UltraPly QuickSeam products will be applied.
• Apply a continuous bead of Firestone Waterblock behind the metal flanges where the scupper will be nailed.
• Pay extra attention to the sequence of applying the ply’s of UltraPly TPO QuickSeam.
•A continuous bead of UltraPly TPO GP Sealant is required on all edges.
![Page 11: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/11.jpg)
Roof Edge with a Gutter
![Page 12: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/12.jpg)
Roof Edge with Fascia
![Page 13: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/13.jpg)
QuickSeam End Lap Splice
![Page 14: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/14.jpg)
![Page 15: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/15.jpg)
Edge Corner with QuickSeam
![Page 16: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/16.jpg)
Roof Edge and Field Seam using QuickSeam
![Page 17: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/17.jpg)
![Page 18: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/18.jpg)
UltraPly TPO Coated Metal, Steps 1 & 2
![Page 19: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/19.jpg)
UltraPly TPO Coated Metal, Steps 3 & 4
![Page 20: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/20.jpg)
QuickSeam TipsHeat vs No Heat
![Page 21: TPO Drains, Scuppers & Roof Edge](https://reader031.vdocuments.us/reader031/viewer/2022031722/56812db9550346895d92ef96/html5/thumbnails/21.jpg)
What’s Wrong?