SERVICE MANUAL Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set. This document has been published to be used for after sales service only. The contents are subject to change without notice. OUTLINE AND DIFFERENCES FROM BASE MODEL OUTLINE.................................................................... i DIFFERENCES FROM BASE MODEL (LC-40LX814E) .......................................................... i DIFFERENCES FROM BASE MODEL (LC-46LX814E) .......................................................... i DIFFERENCES FROM BASE MODEL (LC-40LU824E) ......................................................... ii DIFFERENCES FROM BASE MODEL (LC-46LU824E) ......................................................... ii SAFETY PRECAUTION IMPORTANT SERVICE SAFETY PRECAUTION...........................................................iii Precautions for using lead-free solder ..................... iv End of life disposal .................................................... v OUTLINE MAJOR SERVICE PARTS ....................................... vi Parts Guide TopPage CONTENTS LCD COLOUR TELEVISION No. S00N840LX814E LC-40/46LX814E, LC-40/46LU824E LC-40LX814E LC-46LX814E LC-40LU824E LC-46LU824E MODELS In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its orig- inal condition and only parts identical to those specified should be used. OUTLINE This Service Manual covers the differences from LC-40/46LE814E, LC-40/46LE824E. For other technical information, refer to the LC-40/46LE814E, LC-40/46LE824E (No. S90K840LE814E) Service Manual.

Upload: phungkiet

Post on 28-Jun-2018

230 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

SERVICE MANUAL

Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining thesafety and performance of the set.

This document has been published to be used forafter sales service only.The contents are subject to change without notice.

OUTLINE AND DIFFERENCES FROM BASE MODELOUTLINE.................................................................... iDIFFERENCES FROM BASE MODEL (LC-40LX814E) .......................................................... iDIFFERENCES FROM BASE MODEL (LC-46LX814E) .......................................................... iDIFFERENCES FROM BASE MODEL (LC-40LU824E) ......................................................... iiDIFFERENCES FROM BASE MODEL (LC-46LU824E) ......................................................... ii

SAFETY PRECAUTIONIMPORTANT SERVICE SAFETY PRECAUTION...........................................................iiiPrecautions for using lead-free solder ..................... ivEnd of life disposal .................................................... v

OUTLINEMAJOR SERVICE PARTS ....................................... vi

Parts Guide

TopPage

CONTENTS

LCD COLOUR TELEVISION

No. S00N840LX814E

LC-40/46LX814E, LC-40/46LU824E

LC-40LX814ELC-46LX814ELC-40LU824ELC-46LU824EMODELS

In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its orig-inal condition and only parts identical to those specified should be used.

OUTLINEThis Service Manual covers the differences from LC-40/46LE814E, LC-40/46LE824E.For other technical information, refer to the LC-40/46LE814E, LC-40/46LE824E (No. S90K840LE814E) ServiceManual.

Page 2: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

LC-40/46LX814E, LC-40/46LU824E Service Manual

OUTLINE AND DIFFERENCES FROM BASE MODEL

OUTLINEThis Service Manual covers the differences from LC-40/46LE814E, LC-40/46LE824E.

For other technical information, refer to the LC-40/46LE814E, LC-40/46LE824E (No. S90K840LE814E) Service Manual.

DIFFERENCES FROM BASE MODEL (LC-40LX814E)

DIFFERENCES FROM BASE MODEL (LC-46LX814E)

Ref No. Description LC-40LE814E (No. S90K840LE814E)

LC-40LX814E(No. S00N840LX814E) Interchangeability Note

PRINTED WIRING BOARD ASSEMBLIESN MAIN Unit DKEYDF455FM11 ← — No changeN ICON Unit DUNTKF493FM03 ← — No changeN R/C, LED Unit DUNTKF494FM02 ← — No changeN POWER/LED CONTROL Unit RUNTKA685WJQZ ← — No changeN TOUCH SENSOR Unit RUNTKA692WJQZ ← — No changeN LCD CONTROL Unit RUNTK4512TPZC ← — No change

LCD PANEL MODULEN 40” LCD Panel Module Unit R1LK400D3LWF2Y ← — No change

CABINET PARTS1 Front Cabinet Ass'y CCABAC527WJ1A CCABAC527WJ1C D Changed

Ref No. Description LC-46LE814E (No. S90K840LE814E)

LC-46LX814E(No. S00N840LX814E) Interchangeability Note

PRINTED WIRING BOARD ASSEMBLIESN MAIN Unit DKEYDF455FM11 ← — No changeN ICON Unit DUNTKF493FM03 ← — No changeN R/C, LED Unit DUNTKF494FM02 ← — No changeN POWER/LED CONTROL Unit RUNTKA686WJQZ ← — No changeN TOUCH SENSOR Unit RUNTKA692WJQZ ← — No changeN LCD CONTROL Unit RUNTK4512TPZG ← — No change

LCD PANEL MODULEN 46” LCD Panel Module Unit R1LK460D3LWG2Y ← — No change

CABINET PARTS1 Front Cabinet Ass'y CCABAC528WJ1A CCABAC528WJ1C D Changed

i

Page 3: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

DIFFERENCES FROM BASE MODEL (LC-40LU824E)

DIFFERENCES FROM BASE MODEL (LC-46LU824E)

Ref No. Description LC-40LE824E (No. S90K840LE814E)

LC-40LU824E(No. S00N840LX814E) Interchangeability Note

PRINTED WIRING BOARD ASSEMBLIESN MAIN Unit DKEYDF455FM12 ← — No changeN ICON Unit DUNTKF493FM03 ← — No changeN LOGO Unit DUNTKF493FM04 ← — No changeN R/C, LED Unit DUNTKF494FM02 ← — No changeN POWER/LED CONTROL Unit RUNTKA685WJQZ ← — No changeN TOUCH SENSOR Unit RUNTKA761WJQZ ← — No changeN LCD CONTROL Unit RUNTK4512TPZC ← — No change

LCD PANEL MODULEN 40” LCD Panel Module Unit R1LK400D3LWF0Y ← — No change

CABINET PARTS1 Front Cabinet Ass'y CCABAC621WJ12 CCABAC621WJ13 D Changed

Ref No. Description LC-46LE824E (No. S90K840LE814E)

LC-46LU824E(No. S00N840LX814E) Interchangeability Note

PRINTED WIRING BOARD ASSEMBLIESN MAIN Unit DKEYDF455FM12 ← — No changeN ICON Unit DUNTKF493FM03 ← — No changeN LOGO Unit DUNTKF493FM04 ← — No changeN R/C, LED Unit DUNTKF494FM02 ← — No changeN POWER/LED CONTROL Unit RUNTKA686WJQZ ← — No changeN TOUCH SENSOR Unit RUNTKA761WJQZ ← — No changeN LCD CONTROL Unit RUNTK4512TPZG ← — No change

LCD PANEL MODULEN 46” LCD Panel Module Unit R1LK460D3LWG0Y ← — No change

CABINET PARTS1 Front Cabinet Ass'y CCABAC612WJ12 CCABAC612WJ13 D Changed

Interchangeability

Completely interchangeableA: = NEWOLD

Interchangeable from

OLD to NEWB: NEWOLD

Interchangeable from

NEW to OLDC: NEW OLD

Not interchangeableD: X OLDNEW

ii

Page 4: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

LC-40/46LX814E, LC-40/46LU824E Service Manual

SAFETY PRECAUTION

IMPORTANT SERVICE SAFETY PRECAUTION

WARNING1. For continued safety, no modification of any circuit should be

attempted.

2. Disconnect AC power before servicing.

BEFORE RETURNING THE RECEIVER (Fire & Shock Hazard)Before returning the receiver to the user, perform the followingsafety checks:

3. Inspect all lead dress to make certain that leads are not pinched,and check that hardware is not lodged between the chassis andother metal parts in the receiver.

4. Inspect all protective devices such as non-metallic control knobs,insulation materials, cabinet backs, adjustment and compartmentcovers or shields, isolation resistor-capacitor networks, mechanicalinsulators, etc.

5. To be sure that no shock hazard exists, check for leakage current inthe following manner.

• Plug the AC cord directly into a 220~240 volt AC outlet.

• Using two clip leads, connect a 1.5k ohm, 10 watt resistor paral-leled by a 0.15µF capacitor in series with all exposed metal cabinetparts and a known earth ground, such as electrical conduit or elec-trical ground connected to an earth ground.

• Use an AC voltmeter having with 5000 ohm per volt, or higher, sen-sitivity or measure the AC voltage drop across the resistor.

• Connect the resistor connection to all exposed metal parts having areturn to the chassis (antenna, metal cabinet, screw heads, knobsand control shafts, escutcheon, etc.) and measure the AC voltagedrop across the resistor.All checks must be repeated with the AC cord plug connectionreversed. (If necessary, a nonpolarized adaptor plug must be usedonly for the purpose of completing these checks.)Any reading of 1.05 V peak (this corresponds to 0.7 mA peak AC.)or more is excessive and indicates a potential shock hazard whichmust be corrected before returning the monitor to the owner.

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

SAFETY NOTICEMany electrical and mechanical parts in LCD colour television havespecial safety-related characteristics.

These characteristics are often not evident from visual inspection, norcan protection afforded by them be necessarily increased by usingreplacement components rated for higher voltage, wattage, etc.

Replacement parts which have these special safety characteristics areidentified in this manual; electrical components having such featuresare identified by “ ” and shaded areas in the Replacement PartsList and Schematic Diagrams.

For continued protection, replacement parts must be identical to thoseused in the original circuit.

The use of a substitute replacement parts which do not have the samesafety characteristics as the factory recommended replacement partsshown in this service manual, may create shock, fire or other hazards.

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the servicing guidelines which follow:

CAUTION:

FOR CONTINUED PROTECTION AGAINST A

RISK OF FIRE REPLACE ONLY WITH SAME

TYPE FUSE.

40 inch model: F7000, F7001 (3.15A/250V)

46 inch model: F7000, F7001 (5A/250V)

DVM

AC SCALE

1.5k ohm10W

TO EXPOSEDMETAL PARTS

CONNECT TOKNOWN EARTHGROUND

0.15 µF

TEST PROBE

iii

Page 5: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

Precautions for using lead-free solder

Employing lead-free solder• “PWBs” of this model employs lead-free solder. The LF symbol indicates lead-free solder, and is attached on the PWBs and service manuals. The

alphabetical character following LF shows the type of lead-free solder.

Example:

Using lead-free wire solder• When fixing the PWB soldered with the lead-free solder, apply lead-free wire solder. Repairing with conventional lead wire solder may cause dam-

age or accident due to cracks.

As the melting point of lead-free solder (Sn-Ag-Cu) is higher than the lead wire solder by 40 °C, we recommend you to use a dedicated solderingbit, if you are not familiar with how to obtain lead-free wire solder or soldering bit, contact our service station or service branch in your area.

Soldering• As the melting point of lead-free solder (Sn-Ag-Cu) is about 220 °C which is higher than the conventional lead solder by 40 °C, and as it has poor

solder wettability, you may be apt to keep the soldering bit in contact with the PWB for extended period of time. However, Since the land may bepeeled off or the maximum heat-resistance temperature of parts may be exceeded, remove the bit from the PWB as soon as you confirm thesteady soldering condition.

Lead-free solder contains more tin, and the end of the soldering bit may be easily corroded. Make sure to turn on and off the power of the bit asrequired.

If a different type of solder stays on the tip of the soldering bit, it is alloyed with lead-free solder. Clean the bit after every use of it.

When the tip of the soldering bit is blackened during use, file it with steel wool or fine sandpaper.

• Be careful when replacing parts with polarity indication on the PWB silk.

Lead-free wire solder for servicing

Part No. Description CodeZHNDAi123250E J φ0.3mm 250g (1roll) BLZHNDAi126500E J φ0.6mm 500g (1roll) BKZHNDAi12801KE J φ1.0mm 1kg (1roll) BM

L F a

Indicates lead-free solder of tin, silver and copper.

L F a/a

Indicates lead-free solder of tin, silver and copper.

iv

Page 6: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

End of life disposal

End of life disposal

v

Page 7: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

LC-40/46LX814E, LC-40/46LU824E Service Manual

OUTLINE

MAJOR SERVICE PARTS

PWB UNIT

NOTE: (*1) Replace MAIN Unit (DKEYDF455FM11, DKEYDF455FM12) in case of IC8401 or IC3302 failure.

(*2) TOUCH SENSOR Unit (RUNTKA761WJQZ) reuse will be impossible, once it is stuck on front cabinet and exfoliates.

Therefore, please exchange of a TOUCH SENSOR Unit in the case of front cabinet exchange.

OTHER UNIT

IC FOR EXCLUSIVE USE OF THE SERVICE

SERVICE JIGS

Ref No. Parts Code DescriptionN DKEYDF455FM11 MAIN Unit (LC-40LX814E)(LC-46LX814E) (*1)N DKEYDF455FM12 MAIN Unit (LC-40LU824E)(LC-46LU824E) (*1)N DUNTKF493FM03 ICON UnitN DUNTKF493FM04 LOGO Unit (LC-40LU824E)(LC-46LU824E)N DUNTKF494FM02 R/C, LED UnitN RUNTKA685WJQZ POWER/LED CONTROL Unit (LC-40LX814E)(LC-40LU824E)N RUNTKA686WJQZ POWER/LED CONTROL Unit (LC-46LX814E)(LC-46LU824E)N RUNTKA692WJQZ TOUCH SENSOR Unit (LC-40LX814E)(LC-46LX814E)N RUNTKA761WJQZ TOUCH SENSOR Unit (LC-40LU824E)(LC-46LU824E) (*2)N RUNTK4512TPZC LCD CONTROL Unit (LC-40LX814E)(LC-40LU824E)N RUNTK4512TPZG LCD CONTROL Unit (LC-46LX814E)(LC-46LU824E)

Ref No. Parts Code DescriptionN R1LK400D3LWF2Y 40” LCD Panel Module Unit (LC-40LX814E)N R1LK460D3LWG2Y 46” LCD Panel Module Unit (LC-46LX814E)N R1LK400D3LWF0Y 40” LCD Panel Module Unit (LC-40LU824E)N R1LK460D3LWG0Y 46” LCD Panel Module Unit (LC-46LU824E)

Ref No. Parts Code Description Q’tyIC501 RH-iXD108WJQZS IC (EDID for PC) 1

IC2002 RH-iXC786WJNJQ IC (Monitor MICON) 1

Ref No. Parts Code Description Q’tyN QCNW-G616WJQZ Main Unit to LCD Control Unit (LW) 1N QCNW-G625WJQZ LCD Control Unit to Power Unit (PL) 1N QCNW-H184WJQZ Main Unit to Power Unit (PD) 1N QCNW-H185WJQZ Main Unit to Power Unit (LB) 1N QCNW-K594WJQZ Main Unit to R/C, LED Unit (RA) 1N QCNW-K595WJQZ Main Unit to Speaker (SP) 1N QCNW-K596WJQZ Main Unit to LOGO Unit (RL) (LC-40LU824E)(LC-46LU824E) 1N QCNW-K597WJQZ Main Unit to Woofer (SB) 1

vi

Page 8: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

vii

Page 9: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

PartsGuide

PARTS GUIDE

CONTENTS

No. S00N840LX814E

LCD COLOUR TELEVISION

LC-40LX814ELC-46LX814ELC-40LU824ELC-46LU824EMODELS

[1] PRINTED WIRING BOARD ASSEMBLIES

[2] LCD PANEL MODULE

[3] CABINET PARTS (LC-40LX814E)

[4] CABINET PARTS (LC-46LX814E)

[5] CABINET PARTS (LC-40LU824E)

[6] CABINET PARTS (LC-46LU824E)

Parts marked with " " are important for maintaining the safety of the set. Be sure to replace theseparts with specified ones for maintaining the safety and performance of the set.

This document has been published to be usedfor after sales service only.The contents are subject to change without notice.

Page 10: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824EPRICE NEW PART

NO. PARTS CODE RANK MARK DELIVERY DESCRIPTION

[1] PRINTED WIRING BOARD ASSEMBLIESN DKEYDF455FM11 CG N P MAIN Unit (LC-40LX814E)(LC-46LX814E)N DKEYDF455FM12 CL N P MAIN Unit (LC-40LU824E)(LC-46LU824E)N DUNTKF493FM03 AM N P ICON UnitN DUNTKF493FM04 AN N P LOGO Unit (LC-40LU824E)(LC-46LU824E)N DUNTKF494FM02 AP N P R/C, LED Unit

! N RUNTKA685WJQZ BT N P POWER/LED CONTROL Unit (LC-40LX814E)(LC-40LU824E)! N RUNTKA686WJQZ BV N P POWER/LED CONTROL Unit (LC-46LX814E)(LC-46LU824E)

N RUNTKA692WJQZ AU N P TOUCH SENSOR Unit (LC-40LX814E)(LC-46LX814E)N RUNTKA761WJQZ BC N P TOUCH SENSOR Unit (LC-40LU824E)(LC-46LU824E)N RUNTK4512TPZC CA P LCD CONTROL Unit (LC-40LX814E)(LC-40LU824E)N RUNTK4512TPZG N P LCD CONTROL Unit (LC-46LX814E)(LC-46LU824E)

[2] LCD PANEL MODULEN R1LK400D3LWF2Y DM N P 40" LCD Panel Module Unit (LC-40LX814E)N R1LK460D3LWG2Y DV N P 46" LCD Panel Module Unit (LC-46LX814E)N R1LK400D3LWF0Y DM N P 40" LCD Panel Module Unit (LC-40LU824E)N R1LK460D3LWG0Y DX N P 46" LCD Panel Module Unit (LC-46LU824E)

2

Page 11: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

[3] CABINET PARTS (LC-40LX814E)

48

4641

15

5

20

40

46

32

2-3

2-2

39

39 33

25

13

11

4444

14

44

1251

51

10

44

44

44

44

4517

45

4414

44

23

22

1716

17

44

2729

53

18

7

44

44

44

56

21

21 65

28

36

631

30

37

35

8

2644

16

16

9

16

4

1644

44

44

44

44

38

38

46

19

47

2

2-4

2-9

2-9

2-7

2-6

2-8

2-1

2-5

59

61

G

k

a

L

J

B

j

F

G

E

40" LCDPanel Module Unit

gf

h

K

POWER Unit

F

n

m

g

f

j

E

k

h

m

na

MAINUnit

db

p

K

C

C

B

X3X3

X2

X1A

AX1

X3

Note:

Be sure to attach this insulation sheet. (Ref No. 2-6, 25, 53)

Otherwise there is a risk of electric shock.

Z Z

1-11

R/C,LED Unit

TOUCHSENSORUnit

d ICONUnitp

b

L

J

1-2

1-3

58

63

64

52

52

50

3

Page 12: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

NO. PARTS CODE PRICE RANK

NEW MARK

PART DELIVERY DESCRIPTION

[3] CABINET PARTS (LC-40LX814E)1 CCABAC527WJ1C N P Front Cabinet Ass'y

4

Page 13: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

[4] CABINET PARTS (LC-46LX814E)

48

50

43

16

48

2149

74

74

5

72

48

40

46

40

17

952

46

4617

4

4617

22

42

37

46

31

2933

57

7

39

23

6

46

30

38

34

32

46

46

71

70

73

66

69

67

68

23

828

46

1-1

41

41 35

47

47

46

13

46

19

19 12

46

46

10

55

47

2524

11

46 46

19

19

19

1946

15

14

46

27

46

46

46

61

65

63

64

B

G

h

F

k

j

POWERUnit

g

f

m

MAINUnit

h

db

p

Z

k

a

E

K m

a

L

CC

46" LCDPanel Module Unit

j

Y

G

gf

B F

J

E

K

X3X3

X1

X2A

AX1

X3

Note:

Be sure to attach this insulation sheet. (Ref No. 27, 57, 71)

Otherwise there is a risk of electric shock.

Z

Y

1

R/C,LED Unit

TOUCHSENSORUnit

dICONUnitp

b

L

J

1-2

1-3

58

59

60

18

51

51

53

53

5

Page 14: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

NO. PARTS CODE PRICE RANK

NEW MARK

PART DELIVERY DESCRIPTION

[4] CABINET PARTS (LC-46LX814E)1 CCABAC528WJ1C N P Front Cabinet Ass'y

6

Page 15: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

[5] CABINET PARTS (LC-40LU824E)

48

4641

15

5

20

40

46

32

2-3

2-2

39

39 33

1-4

1-5

1-13

25

13

11

4444

14

44

12

10

44

44

44

44

4517

45

4414

44

23

22

49

49

1716

17

44

2729

53

7

44

44

44

56

21

21 65

28

36

631

30

34

37

35

8

2644

16

16

9

16

4

1644

44

44

44

44

38

38

46

19

47

2

2-4

2-9

2-9

2-7

2-6

2-8

2-1

2-5

59

61

G

k

a

L

H

L

R/C, LED Unit

LOGOUnit

ICONUnit b

dTOUCHSENSORUnit

e

p

J

J

H

B

j

F

G

E

40" LCDPanel Module Unit

gf

h

K

POWERUnit

F

n

m

g

f

j

E

k

h

m

na

MAINUnit

db

e

p

K

C

C

B

X3X3

X2

X1A

AX1

X3

Note:

Be sure to attach this insulation sheet. (Ref No. 2-6, 25, 53)

Otherwise there is a risk of electric shock.

1-5

1-5

1-5

1-5

Z Z

54

55

58

63

64

18

51

5152

52

50

1

7

Page 16: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

NO. PARTS CODE PRICE RANK

NEW MARK

PART DELIVERY DESCRIPTION

[5] CABINET PARTS (LC-40LU824E)1 CCABAC621WJ13 N P Front Cabinet Ass'y

8

Page 17: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

[6] CABINET PARTS (LC-46LU824E)

48

50

43

16

48

2149

74

74

5

72

48

40

46

40

17

952

46

4617

4

4617

22

42

37

46

31

2933

57

7

39

23

6

46

30

38

34

32

36

46

60

46

71

70

73

66

69

67

68

23

828

46

1-4

1-5 1-5

1-53

59

1-1 41

41 35

47

47

46

46

13

46

19

19 12

46

46

10

55

47

2524

11

46 46

19

19

19

51

51

1946

15

14

54

54

46

27

56

46

46

46

61

65

63

64

B

G

h

F

k

j

POWERUnit

g

f

m

MAINUnit h

db

p

Z

k

a

e

E

K m

J

H

J

L

LOGOUnit ICON

Unit

e

p R/C, LED Unitb

d TOUCHSENSORUnit

a

L

CC

46" LCDPanel Module Unit

j

Y

G

gf

B F

H

E

K

X3X3

X1

X2A

AX1

X3

Note:

Be sure to attach this insulation sheet. (Ref No. 27, 57, 71)

Otherwise there is a risk of electric shock.

Z

Y

62

44

45

58

18

53

53

1

9

Page 18: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

NO. PARTS CODE PRICE RANK

NEW MARK

PART DELIVERY DESCRIPTION

[6] CABINET PARTS (LC-46LU824E)1 CCABAC612WJ13 N P Front Cabinet Ass'y

10

Page 19: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-40/46LX814E, LC-40/46LU824E

No part of this publication may be reproduced,stored in a retrieval system, or transmitted inany form or by any means, electronic, mechanical,photocopying, recording, or otherwise, withoutprior written permission of the publisher.

COPYRIGHT © XXXX BYSHARP CORPORATION

ALL RIGHTS RESERVED.

MEMO

Page 20: TopPage LC-40/46LX814E, LC-40/46LU824E … LC-40/46LU824E i LC-40/46LX814E, LC-40/46LU824E OUTLINE AND DIFFERENCES FROM BASE MODELService Manual OUTLINE This Service Manual covers

LC-

SHARP CORPORATIONAV Systems GroupCS Promotion CenterYaita, Tochigi 329-2193, Japan

Oct. 2010SH. KD

COPYRIGHT 2010 BY SHARP CORPORATION

ALL RIGHTS RESERVED.

No part of this publication may be reproduced,stored in a retrieval system, or transmitted inany form or by any means, electronic, mechanical,photocopying, recording, or otherwise, withoutprior written permission of the publisher.

40/46LX814E, LC-40/46LU824E