top of windingbottom of winding original spiral wound pf-1 winding all transitions line up in one...
TRANSCRIPT
![Page 1: Top of WindingBottom of Winding Original spiral wound PF-1 Winding All transitions line up in one direction](https://reader035.vdocuments.us/reader035/viewer/2022062805/5697bfb91a28abf838ca00e9/html5/thumbnails/1.jpg)
Top of Winding Bottom of Winding
Original spiral wound PF-1 Winding
All transitions line up in one direction
![Page 2: Top of WindingBottom of Winding Original spiral wound PF-1 Winding All transitions line up in one direction](https://reader035.vdocuments.us/reader035/viewer/2022062805/5697bfb91a28abf838ca00e9/html5/thumbnails/2.jpg)
Splice joint needed to connect a pair of windings
Cross-over at top of coil for each winding pair
Coil winding approach that minimizes field errors
Inside winding pair
Outside winding pair
![Page 3: Top of WindingBottom of Winding Original spiral wound PF-1 Winding All transitions line up in one direction](https://reader035.vdocuments.us/reader035/viewer/2022062805/5697bfb91a28abf838ca00e9/html5/thumbnails/3.jpg)
Top of winding
Bottom of windingFor the 4 turn coil transitions cancel on the bottom and leads provide some cancellation on top.
Minimum field error PF-1 Winding, 4 x 18
![Page 4: Top of WindingBottom of Winding Original spiral wound PF-1 Winding All transitions line up in one direction](https://reader035.vdocuments.us/reader035/viewer/2022062805/5697bfb91a28abf838ca00e9/html5/thumbnails/4.jpg)
Original spiral wound (10 x 8) PF-4 Winding
All transitions line up in one direction
![Page 5: Top of WindingBottom of Winding Original spiral wound PF-1 Winding All transitions line up in one direction](https://reader035.vdocuments.us/reader035/viewer/2022062805/5697bfb91a28abf838ca00e9/html5/thumbnails/5.jpg)
Top of windingBottom of winding
Minimum field error PF-4 Winding, 8 x 10
For the 8 turn coil transitions cancel on the bottom but line up on the top.