Page 1: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

SE

RIE

40

THE POLYCARBONATE PANELTECHNICAL DATA

Page 2: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

Multiwall panel in co-extruded polycarbonate, UV-protected on one side, with 10 YEARS GUARANTEE against aging. The patented male-female interlock joint ensures perfect water-tightness without needing any sealants. Their insulation and weather resistant charac-teristics ensure that Seplux 40 9P panels are the ideal solution for walling, roofs, sheds, louvers, continuous

windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P panels together with their special stainless steel hooks ensures suitability to both traditional and bespoke designs in size and architectural style, without the need to modify or alter the panels avoiding any drilling, cutting or sealing that would compromise their technical characteristics.

435 mm

40 mm

Patented tongue-and groovejoint, perfectly watertight

Panel Section 40 mm 9-wall

Width 435 mm

Length maximum transportable

Weight kg/m2 4,15

Light Transmission 47,5%

Thermal Insulation U = 1,00 w/(m2 k)

Minimum Bending Radius 200 times the thickness (r = 8000 mm)

Linear Expansion 0,065 mm/m °C

Service Temperature - 40° + 120° °C

Fire Resistance self-extinguishing B S1,d0

Load Resistance kg. 120

Sound insolation 17 dB

Available Colors transparent - opal – smoke - blue – green (other colors on request)

Avis technique (n° 2/10-1433)

Certification UNI EN 14351-1 - Direttiva 89/106/CEE(CPD) EN 13830 - Direttiva 89/106/CEE(CPD)

2/8

TECHNICAL CHARACTERISTICS

TECHNICAL DATA

Page 3: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

USE IN ROOFS

Perfectly watertight, light in weight and easily to in-stall: these are the most commonly needed cha-racteristics of a roofing. The panel SepLux 40 9P is the ideal product for this type of construction as no special preparation such as drilling, cutting or sealing is required. When SepLux 40 9P is used for roofs, a slope of at least 12% is recommended. The panels are fastened down by special stainless steel hooks at positions corresponding to the longitudinal supports. The positions and the number of hooks depend on the characteristics of the supporting structure and on

the design and architectural requirements. We sug-gest the panels be fastened down using the stainless steel hooks at every available support.

ATTENTION: The differing load bearing capacities, for the same span, between vertical and roofing ap-plications are given by the need to considering, in this latter case, as well as wind load, also dead weight, incidental (snow) loads and depression loads.

Detail of roof Ridge

Detail of fasteningsfor roof panels/gutter

Detail of fastening forfaçade panels/gutter

3/8

Page 4: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

SEPLUX 40 9P VERTICAL

The patented watertight tongue-and groove-joint confers unique qualities to the Seplux 40 9P panel. This is the ideal panel for the most special applications and for walling of medium and large dimensions.

The typical cellular structure offers high load resis-tance as well as excellent light transmission.Guarantee 10 years with UV-protection.

Thanks to the patented panel edge joint we can use free span SepLux 40 9P panels of height up to 220 cm without supporting structures while guaranteeing a perfect watertight joint and also load bearing characte-ristics.

ATTENTION: Drilling is a difficult operation that we suggest to avoid; creating through-holes in polycarbonate (whether hollow or slab) not only reduces the life of the material, but damages even more the quality of the installation itself.ATTENTION: The distance of the pitches in the support structure can vary according to the applied load.ATTENTION: We suggest the sealing of the multi-wall panel’s edges with adhesive aluminum tape.

UP TO CM 220

Detail of stainless steel hookfor horizontal fastening

Stainless steel hook forhorizontal fastening

4/8

Page 5: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

HIGHER THAN 250 CM

In these cases, SepLux 40 9P panels are fastened to a wood or steel structure using a specific stain-less steel hook that allows connection to the support structure without need to drill any through-holes in the panels; this guarantees:• Water tightness• Free movement of the panels to allow expansion• High resistance to pressure loads

The combined use of SepLux 40 9P panels and the special stainless steel hooks allows construction of traditional as well as special installations, both under the dimensional and the architectural aspect, with noneed to modify or alter the panels by any drilling, cut-ting or sealing that would compromise their technicalcharacteristics.

Detail of stainlesssteel hook for vertical fastening

5/8

optional sealing

h. fr

ame

942

h. fr

ame

942m

m h

. tot

al 1

000m

m (e

xam

ple)

Aluminum profile foropening windows

Page 6: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

SEPLUX PANELS LOAD CAPACITY

Analysis chart of Seplux 40 9P panels load capacity (double support)

Span = mm

SEP s.r.l.

1 800,00

1 900,00

2 000,00

2 100,00

2 200,00

luce VS carico Curva freccia 1/50

Curva di carico massimo freccia 1/25

Curva freccia 1/100

1 000,00

1 100,00

1 200,00

1 300,00

1 400,00

1 500,00

1 600,00

1 700,00

0 50 100 150 200 250 300 350 400

luce

cam

pata

(mm

)

Carico q (kg/m2)

Analisi analitica luce VS carico applicato pannelli in policarbonato.

SEP s.r.l.

1 750,00

1 800,00

1 850,00

1 900,00

1 950,00

2 000,00

2 050,00

2 100,00

2 150,00

2 200,00

luce VS carico Curva freccia 1/50

Curva di carico massimo freccia 1/25

Curva freccia 1/100

1 000,00

1 050,00

1 100,00

1 150,00

1 200,00

1 250,00

1 300,00

1 350,00

1 400,00

1 450,00

1 500,00

1 550,00

1 600,00

1 650,00

1 700,00

1 750,00

0 50 100 150 200 250 300 350 400 450

luce

cam

pata

(mm

)

Carico q (kg/m2)

Analisi analitica luce VS carico applicato pannelli in policarbonato.

Span VS load

Load q (Kg/m2)

Spa

n (m

m)

Bend deflection 1/50Bend with maximum load deflection 1/25Bend deflection 1/100

6/8

Page 7: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

SEPLUX PANELS LOAD CAPACITY

Analysis chart of Seplux 40 9P panels load capacity (multiple support)

Span = mm Span = mm

SEP s.r.l.

1 750,00

1 800,00

1 850,00

1 900,00

1 950,00

2 000,00

2 050,00

2 100,00

2 150,00

2 200,00

luce VS carico Curva freccia 1/50

Curva di carico massimo freccia 1/25

Curva freccia 1/100

1 000,00

1 050,00

1 100,00

1 150,00

1 200,00

1 250,00

1 300,00

1 350,00

1 400,00

1 450,00

1 500,00

1 550,00

1 600,00

1 650,00

1 700,00

1 750,00

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

luce

cam

pata

(mm

)

Carico q (kg/m2)

Analisi analitica luce VS carico applicato pannelli in policarbonato.

SEP s.r.l.

2 300,00

2 400,00

2 500,00

2 600,00

2 700,00

2 800,00

2 900,00

3 000,00

luce VS caricoCurva freccia 1/50

Curva di carico massimo freccia 1/25

Curva freccia 1/100

1 000,00

1 100,00

1 200,00

1 300,00

1 400,00

1 500,00

1 600,00

1 700,00

1 800,00

1 900,00

2 000,00

2 100,00

2 200,00

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750

luce

cam

pata

(mm

)

Carico q (kg/m2)

Analisi analitica luce VS carico applicato pannelli in policarbonato.

Span VS load

Load q (Kg/m2)

Spa

n (m

m)

Bend deflection 1/50Bend with maximum load deflection 1/25Bend deflection 1/100

7/8

Page 8: THE POLYCARBONATE PANEL TECHNICAL DATA · solution for walling, roofs, sheds, louvers, continuous windows and both indoor and outdoor partitions. The combined use of SepLux 40 9P

eventuale nastratura

8/8

ALUMINIUM PROFILES SEPLUX 40 9P

Modular panels for roofing, partitions or windows, width 435mm, in co-extruded multi-wall polycar-bonate, UV protected on one side. Thickness 40mm, coplanar and multi-chamber, with patented watertight

interlocking joint. U-Value = 1.00 W/(m2 K); Self-ex-tinguishing Class B S1 d0; colors transparent, opal or colored.

S.E.P. Società Europea Plastica S.r.l.Via Salenghi, 68 / 1-2 - 38060 Volano (TN) Tel. +39 0464 410655 Fax +39 0464 411332www.sepitalia.com • [email protected]

optional sealing

ALUMINIUM PROFILELower, with drip stop.

ALUMINIUM PROFILELower, without drip stop.

ALUMINIUM PROFILEUpper and lateral.

optional sealing

optional sealing

optional sealing

SPECIFICATION