The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
• Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2)
• Up to 32 Channels per network
• HART and PC configurable• 2, 3 & 4-wire RTD, T/C,
Potentiometer and mV inputs
• Two communication modes: HART or MODBUS RTU (RS-485)
Intrinsically Safe Temperature Concentrator System
![Page 2: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/2.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
• 16 Channels• Each TCM channel is a
HART slave, each channel has a unique HART address (0-15)
• Each HART channel has to be individually polled by HART master
• When installed in I.S. areas, TCM module is powered by I.S. Barrier
• Host system acts as HART master
HART Communications Mode
![Page 3: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/3.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
• 16 or 32 Channels• Field located TCM
modules are powered by –TX on HCS
• Each TCM acts as a HART slave with 16 channels
• HMC acts as HART primary master
• Each TCM provides 16ch data in single HART response every 500ms
• HMC converts HART data to serial (RS-485) MODBUS RTU comm’s
MODBUS Communications Mode
![Page 4: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/4.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
• Can supply power to one or two TCMs
• Acts as HART primary master
• Programs with Free PC software
• Two Fault Alarms: one for each TCM
• Alarms can be Fail Safe or Non-Failsafe
• Dual MODBUS RTU (RS-485) comm’s
• Installs in Safe Area
HMC: HART to Modbus Converter
![Page 5: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/5.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
• 16 Channels
• RTD, ohms, potentiometer, T/C and mV Inputs
• Configure Inputs with HART Hand-Held communicator or free PC software
• Powered from I.S Barrier, HART based host system or HMC module
• Installs in Hazardous Area; Class 1 Div 1 (Zone 0 Exia), or Class 1 Div 2 (Zone 2 Type N)
TCM: Temperature Concentrator Module
![Page 6: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/6.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
• HART HHC/Modem connects anywhere on the loop (downstream of HMC)
• HART based HOST system (AMS) can also configure and communicate with TCM
• Configure Sensor Type, Range, Eng Units, Tag, etc.
• Fault status with HHC: Sensor wire broken, Out of range error, perform self test, etc.
• Calibrate with HHC: Input Capture & Sensor Trimming
• Perform maintenance in Hazardous Areas
TCM Setup Using HART Hand Held Communicator
15-42VPower Supply
![Page 7: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/7.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
TCM Setup Using PC Software
• Free PC software supplied
• Simple intuitive programming
• Front panel connection via serial or USB cable
• Configure Sensor Type, Range, Eng units, Tag, etc.
• Calibration functions: Input Capture & Sensor Trimming
![Page 8: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/8.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
HMC Setup Using PC Software
• Monitor TCM 1 / TCM 2: Displays the PV & Channel Status of each connected TCM
• Number of Retries can be set between 1-9 which determines how many times the HMC attempts to communicate with the TMC (without success) before triggering HMC Fault Alarm
• Fault Alarm is non-latching
![Page 9: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/9.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
HMC Setup Using PC Software
• Fault Alarms: two SPDT 2A, 250Vac non-inductive relays
• Alarms can be set for loss of HART comm, sensor failures, config errors, hardware errors and PV out of range
• Alarms are non-latching and can be set for Fail Safe or Non Fail Safe
• MODBUS RTU settings:- Address- Baud Rate- Parity- Float word order- PV register values on loss of communication with TCM
![Page 10: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/10.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
TCS Intrinsically Safe Wiring – Dual Channel Barrier
+ -24Vdc Power Supply
+ -
+IN- IN
MODBUS RTUCommunications
-PS
+PS
- OUT
+OUT
![Page 11: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/11.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
TCS Intrinsically Safe Wiring – Single Channel Barrier
+ -24Vdc Power Supply
+ -
MODBUS RTUCommunications
-PS
+PS
- OUT
+OUT
![Page 12: The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels](https://reader035.vdocuments.us/reader035/viewer/2022070323/56649d9c5503460f94a856b7/html5/thumbnails/12.jpg)
The Interface Solution ExpertsThe Interface Solution Experts
www.miinet.com
• Transmitter Like performance with; 20 bit input resolution & 5 year stability specification
• Eliminates the need for dedicated transmitters or expensive cable installations
• 500Vrms Input to Output Isolation
• Robust design allows -45 to +85°C operation
• Enclosures available for field mounting
Intrinsically Safe Temperature Concentrator System