the atlas tile calorimeter

22
The Atlas Tile Calorimeter Muon Studies at 90° Presented at CERN by Michael Borysow for the University of Michigan REU Program 14/08/03

Upload: john-mckee

Post on 01-Jan-2016

55 views

Category:

Documents


7 download

DESCRIPTION

The Atlas Tile Calorimeter. Muon Studies at 90°. Presented at CERN by Michael Borysow for the University of Michigan REU Program 14/08/03. Outline. Tile Calorimeter Description What is Calorimetry? Specifics to the Atlas Tile Calorimeter My Analysis - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: The Atlas Tile Calorimeter

The Atlas Tile Calorimeter

Muon Studies at 90°

Presented at CERN by Michael Borysow for the University of Michigan REU Program

14/08/03

Page 2: The Atlas Tile Calorimeter

Outline

Tile Calorimeter Description What is Calorimetry? Specifics to the Atlas Tile Calorimeter

My Analysis Muons at 90 Degrees Discoveries

Conclusions

Page 3: The Atlas Tile Calorimeter

Atlas Overview Four Major Components

Inner Tracker Calorimeter – Electromagnetic Calorimeter – Hadronic Muon Spectrometer Magnet System

Page 4: The Atlas Tile Calorimeter
Page 5: The Atlas Tile Calorimeter

What is Calorimetry? Calorimetry refers to the detection of particles through

total absorption in a block of matter. Calorimetry is a destructive method.

The only exceptions being muons.• Muons can penetrate substantial amounts of mass

represented by the calorimeter, thus they become ID’d as muons.

True Calorimeters measure the total energy of a particle and are made of a single substance, such as Germanium or NaI crystal.

The Atlas Tile Calorimeter is a Sampling Calorimeter.

Page 6: The Atlas Tile Calorimeter

Sampling Calorimeters Sampling Calorimeters are made of more than one

substance Active Medium

• Generates light or charge that forms the basis of the calorimeter signal

Passive Medium• Absorbs energy

In Sampling Calorimeters, only a small fraction of the energy is deposited in the active medium.

The advantage of a Sampling Calorimeter is that it is much cheaper and smaller. The goal is still to stop the particle, and the passive medium

can help do this much more quickly.

Page 7: The Atlas Tile Calorimeter

Benefits of a Calorimeter Calorimeters, with tracking data,

allow for effective identification of particles.

Can measure the energy of neutral particles, whereas a magnetic spectrometer cannot.

Fast Response time; Can be used as a trigger for other detector components.

Page 8: The Atlas Tile Calorimeter

The Tile Calorimeter Made of 64x4 submodules

Two Long Barrels Two Extended Barrels

Each submodule is composed of alternating tiles of polystyrene and steel separated into 11 tile rows. Polystyrene is the active medium, while

steel is the passive medium.

Page 9: The Atlas Tile Calorimeter

Extended Barrels

Long Barrels

Page 10: The Atlas Tile Calorimeter
Page 11: The Atlas Tile Calorimeter
Page 12: The Atlas Tile Calorimeter

The Tile Calorimeter Polystyrene acts as a scintillating material. Through various processes, molecules and atoms

will become excited, and then emit light when they drop to the ground state.

The scintillation light is picked up by wavelength shifting fibers (WSF) and carried to Photo Multiplier Tubes (PMTs).

The PMTs then produce an electronic signal, which is digitized and sent to the Data Acquisition Systems.

Page 13: The Atlas Tile Calorimeter
Page 14: The Atlas Tile Calorimeter

Cell Layout Each cell can be read

out individually in two channels.

Each cell has WSFs which on either side. These fibers carry the light to the PMT.

WSFs are used, because the light emitted by the scintillation process is ~100 nm. The PMTs are most sensitive around ~550nm.

Page 15: The Atlas Tile Calorimeter

Studies at 90° Studies at 90 degrees

are used to check tile row uniformity.

Muons are made use of for the reason that they deposit the roughly the same energy in each cell (per Tile) as they pass through the detector.

Thus, muons are useful for detecting bad equipment.

Page 16: The Atlas Tile Calorimeter
Page 17: The Atlas Tile Calorimeter

Tile Row Uniformity

Page 18: The Atlas Tile Calorimeter

Channel Uniformity per Row

Page 19: The Atlas Tile Calorimeter

Channel Summary

Page 20: The Atlas Tile Calorimeter

Distribution of Channel Response

Page 21: The Atlas Tile Calorimeter

Geometry Problems? Currently investigating possibility of

misalignment of the test setup.

Page 22: The Atlas Tile Calorimeter

Acknowledgements Jean Krisch, Homer Neal, and Tom

Dershem My Adviser, Richard Teuscher The Argonne Boys University of Michigan National Science Foundation Ford Motor Company