the agilent masshunter software one software for all ... · pdf filethe agilent masshunter...
TRANSCRIPT
The Agilent
MassHunter Software
One Software for all Agilent Mass Spec
Systems
MassHunter – The most innovative MS SW !
MassHunter Workstation One software for all Agilent MS Systems
LC/MS GC/MS ICP-MS
Minimize learning (and maximize productivity)
with a common software for all of your
mass spec systems
MassHunter Workstation Target Workflows and Key Software Tools
Quantitative Applications (QQQ, TOF and QTOF)
• Targeted Quant in Food, Forensics/Tox, Environment (dMRM, tMRM, Quant)
• Proteomics Targeted Quant of proteins via peptide MRM (Skyline, dMRM, tMRM)
• Pharma Early ADME/DMPK (Study Manager, Optimizer)
• Bioanalysis and BA/BE (Study Manager, WATSON, 21CFRPart11)
Qualitative Applications (TOF and Q-TOF)
• Metabolomics (Qual, MPP, ID via MFG, PCD, PCDL, Pathway Analysis)
• Characterization of Biopharmaceuticals (BioConfirm, Comparative Analysis)
• Screening + ID in Food, Forensics/Tox, Environment (Qual, PCD and PCDLs)
• Impurity and Degradant Analysis (MPP, MFG, PCD, PCDL)
• Pharma Compound Confirmation (Easy Access, Qual, ASR with TOF)
• Protein ID, PTM Analysis (Spectrum Mill with Q-TOF)
• Metabolite ID (Metabolite ID with Q-TOF)
High Throughput Quantitation
• Study Manager to queue up quantitative assays incl. MRM optimization
• Optimizer quickly and easily optimizes MS/MS signal
• Dynamic MRM methods deliver robust assays faster
• WATSON LIMS Integration and Compliance support for BioAnalysis
Proteomics / Metabolomics & Non-targeted Screening
• Mass Profiler Professional (MPP)
− Integrated workflow for feature finding, alignment, differential analysis,
identification and pathway analysis
− Powerful and easy-to-use statistical tools
• Pathway Analysis for direct biochemical pathway interrogation
High Throughput Screening and Identification
• Personal Compound Databases (PCDs) and Libraries (PCDLs)
for accurate mass DB and MS/MS library search with optional RT
• Fully automated acquisition, data processing and reporting
• Supports targeted and untargeted screening
• PCDL Manager software to view and edit PCDs and PCDLs
MassHunter Workstation Increase your productivity significantly
MassHunter
Optimizer
Optimize
Compounds
MassHunter
Acquisition
Acquire
Samples
MassHunter
Study
Manager
Submit Study
Excel or
other
Electronic
Source
Import Sample
Set
End User
App
Software
Calculate
Values Report
MassHunter
Quant
Reporting
MassHunter
Quant
Review
Results
MassHunter
Quant
Analyze Batch
Compound
Database
High-Throughput Targeted Quant in Drug Discovery
“In vitro” screening using Study Manager
Which of the synthesized compounds
will be viable drug candidates?
Study Manager schedules
and automates these steps
Study Manager and Study Creators Queue up multiple assays for highest productivity
• User imports compound and worklist information via spreadsheets
• Study Manager creates worklists, schedules tasks for automated method
development, acquisition, quantitation and reporting
• Different Study Creators for different workflows available
MassHunter B.06.00 Key Qualitative Applications
Accurate Mass LC-MS/MS Identification with 6500 QTOF
Accurate Mass LC/MS/MS Identification
Biopharmaceuticals
• Identification
• Characterization
• Accurate Mass LC/MS/MS Support
• MassHunter Comparative Analysis
Screening and ID Metabolomics
• Forensics/Tox
• Food Safety
• Environmental
• Accurate Mass MS/MS Library
• Broecker, Herre & Pragst Forensics/Tox PCDL
• Identification of Biomarkers
• METLIN AMRT PCD
• METLIN AMRT PCDL
• Accurate Mass MS/MS Library
MassHunter Workstation B.06.00 for TOF/Q-TOF
Confident Screening + ID in Forensics, Food and Environment
• Targeted Workflow • Highest productivity via automatic Finding, identifying and
confirming targeted compounds via Find by Formula using
accurate mass MS info
• Easily create a Personal Compound Database and Library
(PCDL) from targeted compounds via PCDL Manager
• Confirm identity via accurate mass MS/MS spectra library
search in a PCDL via new Directed MS/MS in the first run!
• Untargeted Workflow • Highest productivity via automatic extraction of accurate
mass MS and MS/MS info via Find by MFE with MS/MS
spectral extraction from Auto MS/MS data files.
• Automatically conduct a PCDL search and Molecular
Formula Generation using MS and (!) MS/MS information
• Highest confidence via combined scoring and viewing of
results from AM DB search, AM library search and MFG.
Sample (Blood, Urine, Extracts, …)
Find by Formula
Directed MS/MS
MH data file
Compound AM
MS/MS spectra
PCDL Search
Auto MS/MS
MH data file
Cmpds confirmed
via AM MS/MS
Print Report
Find by MFE +
MS/MS extraction
Compounds with
AM MS/MS spectra
PCD(L) Search
Cmpds identified
via AM MS+MS/MS
Identification of
true unknowns Report
MFG
Similarity
Search
Report
Print Report
MassHunter PCDL Manager B.04.00
Create/edit customized local PCDs and PCDLs
• Personal Compound Database and Libraries (PCDLs) for accurate mass
database and MS/MS library search with optional retention time
• Add compounds, AM MS info, RT info and AM MS/MS spectra at multiple collision energies
using the new PCDL Manager software
• Use create and edit PCDs and PCDLs on your personal PC (keep proprietary data in house!)
SUPPORTS:
METLIN AMRT PCD B.04.00
METLIN AMRT PCDL B.04.00
For/Tox AM PCD B.04.00
For/Tox AM PCDL B.04.00
Pesticide AM PCD B.04.00
The most
comprehensive
offering of
content PCDs
and PCDLs
LC/MS Database and Library Products
Personal Compound Databases (PCDs) for use with accurate mass data;
Personal Compound Database and Libraries (PCDLs) adds ability to library
search MS/MS spectra
.
Application PCD PCDL
Metabolomics METLIN (24,768
compounds)
METLIN (adds spectra for
2286 compounds)
Forensics / Tox 7360 compounds Adds spectra for 2720
compounds
Pesticides 1609 compounds N/A
Glycans 144 compounds N/A
Find biomarkers
for early disease
detection !
To analyze the
food you eat !
Crime Scene
Investigation !
Forensics/Tox Accurate Mass PCDL
“Broecker, Herre & Pragst” – MS/MS spectra for 2720 Cmpds
Extract MS/MS
Spectra when
running MFE
Identification via
accurate mass
MS/MS Lib Search
• The Forensics/Tox accurate mass PCD contains 7360 compounds
• Forensics/Tox accurate mass PCDL contains 8263 MS/MS spectra
for over 2720 compounds from 3 collision energies mostly in positive mode.
=> The first (!) commercially available accurate mass MS/MS library!
Agilent Differential Analysis Workflow
Metabolomics, Proteomics & Untargeted Screening G
CM
S
LC
MS
Separation
& Detection
GC/MSD
GC-QQQ
LC-TOF/QTOF
LC-QQQ
Find features
& Quantitate
MassHunter Qual AMDIS or Find by
chromatographic
deconvolution
MassHunter Qual MFE,
Find by Formula,
Find by Ion
Alignment
& Statistics
Mass Profiler Professional (MPP)
Identify
& Annotate
ID Browser
Pathway
Analysis
Pathway
Module
Mass Profiler (MP)
ID Browser
Multivariate
Analysis
Life Sciences
• Basic Research (Academic) - Improve understanding of biological processes
• Clinical Research - Improve understanding and treatment of human diseases
• Pharmaceutical – Identify toxicological problems, develop efficacy biomarkers
Chemical analysis
• Agriculture - Increase crop efficiency (yield, drought and pest resistance, nutritional value)
• Nutrition – Analysis of food quality, alteration, origin, nutritional value)
• Environmental - Understand effect of pollution on environment
Agilent Differential Analysis Workflow
Target applications
ASMS Metabolomics Bottleneck Summary
2009 ASMS Metabolomics Survey Results
http://metabolomics.us/2009/ASMSMetabolomicsWorkshop/SurveyResults/
81% of respondents say
challenges due to software
NOT hardware
1. Compound Identification
35%
2. Biological Significance 27%
3. Data Processing
14%
4. Statistical Analysis
5%
!!!
New METLIN AMRT PCD and PCDL B.04.00
MS/MS spectra for ~ 2300 endogenous metabolites !
• Now contains ~ 25000 endogenous metabolites
• METLIN AMRT PCD added retention times for 670 compounds
on a RP column. Additional RTs on a hydrophilic column in progress.
• METLIN AMRT PCDL contains MS/MS spectra from over 2286 compounds
from up to 3 collision energies in positive and/or negative mode (~ 9000 spectra total)
New MassHunter BioConfirm B.05.00
More confidence in identification of biopharmaceuticals
Higher confidence in peptide
identification using an accurate
mass MS/MS score
=> Reduce false positives
Allows to clearly identify sites of
modification, e.g.:
TSPYVLPVPFLNVLNGGSHAGG
ALALQEFMIAPTGAK
=> Unique ions confirm
Oxidation at Met
Adding the power of
accurate mass MS/MS !
New MassHunter Comparative Analysis B.05.00
Compare two protein samples and visualize the difference
Coloring whether
found in sample,
Reference, or both
Compare chromato-
grams (TIC, ECC,
BPC, TCC) via
mirror plot
Compare MS and
MS/MS spectra
underneath each
other
Visualize and
compare sequence
coverage in both
samples
Faster performance
and larger data sets
with native 64-bit
code
MassHunter Metabolite ID
Easy, confident and highly productive Metabolite ID
Page 19
Productivity
• One-click Metabolite ID data processing
• Compound-centric data navigation
• Summary view of results at a glance
Comprehensive
• Comparison of sample and control via
untargeted approach based on Molecular
Feature Extraction (MFE)
• Predicted and unexpected metabolites
Confidence in Results
• Widest range of and most sophisticated
algorithms (MFE, MFG, Novatia Autoshift)
• Productivity and Confidence
• Sophisticated Sample-Control Comparison
Algorithm based on Molecular Feature
Extraction (MFE) allows more comprehensive
detection of differences via exploitation of accurate
mass and RT.
• First find all differences in an untargeted
approach and THEN confirm and identify
• Best suited to find and confirm expected and
unexpected metabolites
• More confidence for confirming expected and
identifying unexpected metabolites using multiple
algorithms
• Novatia Autoshift algorithm to help located
modifications via MS/MS spectral correlation.
Sample Control
Compounds Compounds
Potential Metabolites
Identified Metabolites
MFE MFE
Compare
Confirm + identify
MassHunter Metabolite ID
Easy, confident and highly productive Metabolite ID
THANK YOU!
Introducing
MassHunter 64
Next Generation Platform
•More available memory to allow rapid processing of large data sets and
multiple compound analyses
•Leveraging the enhanced speed of 64-bit processing for faster performance
MassHunter 64 – Integrated Software Tools
Quantify Identify
• Qualitative Analysis B.05.00
• BioConfirm B.05.00
• Molecular Structure Correlator (MSC) B.05.00
• Quantitative Analysis B.05.01
• MassHunter Acquisition for TOF/Q-TOF B.05.00
• MassHunter Acquisition for QQQ B.05.00
Confidence
MassHunter 64 – Improved Data Processing
Limitations of 32-bit operating systems and applications
• 32-bit operating systems and programs can address a MAXIMUM of 4 GB of
Random Access Memory (RAM)
• The Windows XP operating system (32-bit) is allocated 2 GB; all other programs
are allocated up to 2 GB shared among them – the result is slower performance
and memory crashes
2 GB 2 GB
Windows XP --MassHunter Qual
--PCDL Manager
--Anti-virus software
MassHunter 64 – Harness the Power of 64-bit
Improved performance for the most complex data sets:
• Windows 7 64-bit and native 64-bit applications can utilize up to 192 GB of
RAM
• When a native 64-bit program such as MassHunter Qual runs on Windows 7,
it can use all the remaining memory
2 GB 6 GB (shipping
Workstation)
Up to 24 GB optional Windows 7 Pro
--MassHunter Qual
--MassHunter Quant
MH Qual B.05.00 Identify MORE Compounds with Greater Confidence
• Metabolomics customers can perform Find-by-Formula on the entire METLIN database (24,768 entries) in minutes
Use large databases as a Formula Source
• Forensics customers with Q-TOFs can run in Auto MS/MS mode, then Find-by-Formula on Forensics/Tox (7360 compounds), and match their MS/MS spectra (available in B.05.00) against the Forensics/Tox PCDL
MS/MS Libraries searches on FbyF compounds
• Suspect targets in Find-by-Formula are flagged and can be manually reviewed
• Manually add missed compounds
Manual review and override are easy
Find-by-Formula is now 20x faster therefore replacing Molecular Feature Extractor as the tool of choice for targeted workflows
MassHunter 64 – Identify with Confidence
•Personal Compound Database and Library (PCDL)
Agilent is the first vendor to sell accurate mass MS/MS libraries
– Higher confidence identifications
– Run library searches from Qual
or PCDL Manager
– Display structures and difference
spectra of hits in Qual
– Customers can create their own libraries
or append to a purchased library
MassHunter 64 – Identify with Confidence
BioConfirm B.05.00 for more confident biopharmaceutical
characterization
• Detect differences between even the most complex digests in less time
(4000 peptides in 4 minutes)
• Peaks containing proteins with large differences in molecular weights can
be deconvoluted successfully
• MS/MS support to confirm the location of PTMs
MassHunter 64 – Identify with Confidence
Molecular Structure Correlator (MSC) B.05.00
• Use MS/MS spectra to go from formula to structures
– Match substructures to specific fragments for positive identifications
– Access formula and structures from Agilent PCD/PCDLs or the ChemSpider database (26
million compounds) to provide the most likely structures (only Agilent offers this capability!)
C23H31NO2
Proadifen MSC
MassHunter 64 – Quantify with Confidence
Quantitative Analysis B.05.01
for the next generation of processing speed
• 5x Faster Accurate Mass Quantitation
• Easier Accurate Mass Method-building via import from Qual results
• Using Qual Find-by-Formula algorithm for more confident compound
confirmation
• More confident confirmation of MRM data by comparing triggered MRM
data to reference library
MassHunter 64 – Identify and Quantify with
Confidence
MassHunter LC/MS Acquisition B.05.00
• Improved workflows
– New Study Creator for automatically importing worklists into the Study
Queue
• Improved user interface for better usability
• Ability to quantify a peak and generate a report at the end of every run
– get your results back sooner than batch processing mode
MassHunter 64 – Identify and Quantify with
Confidence
More confident compliance
• Improved log file tracks owner of each injection
• Audit trail on all Acquisition method changes
• New Audit Trail report for Quant results
• Easy connection to OpenLab ECM for secure data archival and retrieval
MassHunter 64 – How to Upgrade
1. G3337AA MassHunter Workstation for QQQ Software Upgrade
2. G3849AA MassHunter Workstation for TOF/Q-TOF Software Upgrade
3. G3338AA MassHunter Workstation Offline Software Upgrade
4. G3336AA MassHunter Workstation Software Offline
– for customers who have an instrument and just want the offline software
5. G1668AA Windows 7 MassHunter Workstation
– HP Z400 with 8 GB RAM
In Summary… MassHunter Programs Give You Confidence
Quantify Identify
• Qualitative Analysis
• BioConfirm
• Molecular Structure Correlator (MSC)
• Quantitative Analysis
• MassHunter Acquisition for TOF/Q-TOF and QQQ
Confidence