BUROCCO INDUSTRIAL VALVES S.r.l. BUROCCO INDUSTRIAL VALVES S.r.l. Via Noveis, 33 - 13867 Pray (BI) Italy Tel. +39 015 767 278 - Fax +39 015 767 136 [email protected] - P. IVA: 02526580028 Copyright © 2014 BUROCCO INDUSTRIAL VALVES S.r.l. 97/23/EC -PED 94/9/EC - ATEX Technical Manual

Upload: others

Post on 04-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BUROCCOINDUSTRIAL VALVES S.r.l.

BUROCCOINDUSTRIAL VALVES S.r.l.

Via Noveis, 33 - 13867 Pray (BI) ItalyTel. +39 015 767 278 - Fax +39 015 767 136 [email protected] - P. IVA: 02526580028

Copyright © 2014 BUROCCO INDUSTRIAL VALVES S.r.l.97/23/EC -PED 94/9/EC - ATEX

Technical Manual

Page 2: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice

Capitolo2 / Chapter 2

Indice/Index Pag.

Coefficienti di Portata (CV-KV) - Flow coefficients (CV-KV)………………………………………………………..………………… 139

Coefficienti di Portata Serie EURO (CV-KV) - EURO Series Flow coefficients (CV-KV)……..…………..………………… 140

Coefficienti di Portata Disponibili (CV) - Flow coefficients available (CV)…………………………………..………………… 141

Coefficienti di Portata Ridotti (Microflusso) - Flow coefficients reduced (Lowflow)…………..………………….……… 142

Otturatori e Caratteristiche di Regolazione—Plug and control specifications………………………..……………………. 143 ÷ 146

Pressione—Temperature—Materiale Corpo Valvola—Pressure—Temperature—Body Material……….……..… 147

Limiti Impiego Temperatura—Tipologia Valvole—Temperature use limit—Valves type…..…………………………. 148 ÷ 149

Servocomando a Diaframma Pressioni Differenziali—Diaphragm servocontrol Differential pressure……....…. 150 ÷ 152

Servocomando On-Off Pressioni Differenziali—ON-OFF Servocontrol Differential pressure…………………..……. 153

Coefficienti di Portata Disponibili (CV) On-Off Valves - Flow coefficients available (CV)On-Off Valves…………. 155

Coefficienti di Portata Disponibili (CV) Ball Valves - Flow coefficients available (CV) Ball Valves..………………… 156

Condizioni generali di vendita—General sales conditions………..………………………………………………..……………….. 157

138

Page 3: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

1/20

FLOW COEFFICIENTS

All CV-KW that are listed in the table above are calculated using modern information systems.

The Technical Office makes use of modern CAD Solid Works (Dassault Systèmes) updated with the latest release available

and functional.

A special internal application of the CAD, "Flow Simulation", allows to make the calculation of flow with an error of 2/3%

Check and calculation Software

Flow coefficients CV

The valve sizing is performed using the flow coefficient CV and it is referred to the following condition:

- Static pressure drop between the upstream and downstream valve= 1psi (6895 Pa)

- Transiting fluid: water at a temperature comprised between 40 and 100 °F (5 ÷ 40 °C)

- Units of measure the volumetric flow rate: gallons per minute (gpm)

Flow coefficients KV

The valve sizing is performed using the flow coefficient CV and it is referred to the following condition:

- Static pressure drop between the upstream and downstream valve= 1bar (105 Pa)

- Transiting fluid: water at a temperature comprised between 5 ÷ 40 °C

- Units of measure the volumetric flow rate: m3/h

CV=1,17KV

139

Page 4: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

2/20

DN CV

(gpm) KV

(m3/h) DN

CV(gpm)

KV (m3/h)

15

4 3,5 15

65

72 61,5 64

2,5-1,5 2,1-1,3 10 48 41 50

1-0,5 0,85-0,43 6 28 24 38

0,3-0,1 0,26-0,09 4 18 15,5 32

20

7 6 20

80

105 90 71

4 3,5 15 72 61,5 64

2,5-1,5 2,1-1,3 10 48 41 50

1-0,5 0,85-0,43 6 28 24 38

0,3-0,1 0,26-0,09 4 160 136 32

100

25

12 10 24 105 90 71

7 6 20 72 61,5 64

4 3,5 15 48 41 50

2,5-1,5 2,1-1,3 10 28 24 38

1-0,5 0,85-0,43 6

0,3-0,1 0,26-0,09 4

32

18 15,5 32

12 10 24

7 6 20

4 3,5 15

2,5-1,5 2,1-1,3 10

1-0,5 0,85-0,43 6

40

28 24 38

18 15,5 32

12 10 24

7 6 20

4 3,5 15

2,5-1,5 2,1-1,3 10

50

48 41 50

28 24 38

18 15,5 32

12 10 24

7 6 20

4 3,5 15

Dia

me

tro

Dia

me

tro

Standard CV and KV

Available CV only with nodular cast iron GGG 40 (PN16)

Available CV only for body in 1.0619 and CF8M (PN16 - PN40)

Available CV in all material

Material and dimension available

FLOW COEFFICIENTS SERIE EURO1

1=maximum value of CV and KV refers to the seat diameter chosen.

140

Page 5: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

3/20

FLOW COEFFICIENTS AVAILABLE (CV)

Valve serie

800/803, 2000/2003

DN CV

(gpm)

KV

(m3/h)

15 4 3,5 15

20 7 6 20

4 3,5 15

25

12 10 24

7 6 20

4 3,5 15

32

18 15,5 32

12 10 24

7 6 20

4 3,5 15

40

28 24 38

18 15,5 32

12 10 24

7 6 20

4 3,5 15

48 41 50

50

28 24 38

18 15,5 32

12 10 24

7 6 20

4 3,5 15

65

72 61,5 64

48 41 50

28 24 38

18 15,5 32

80

105 90 71

72 61,5 64

48 41 50

28 24 38

100

160 136 95

105 90 71

72 61,5 64

48 41 50

28 24 38

150

300 256 130

210 180 110

160 136 95

105 90 71

72 61,5 64

DN CV

(gpm)

KV

(m3/h)

200

470 400 160

300 256 130

210 180 110

160 136 95

Valve serie 5000

D

N

CV

(gpm)

KV

(m3/h)

15 4 3,5 15

20 7 6 20

4 3,5 15

25

12 10 24

7 6 20

4 3,5 15

18 15,5 32

32 12 10 24

7 6 20

4 3,5 15

40

28 24 38

18 15,5 32

12 10 24

7 6 20

4 3,5 15

50

48 41 50

28 24 38

18 15.5 32

12 10 24

7 6 20

4 3,5 15

Valve serie

3000/3003

DN CV

(gpm)

KV

(m3/h)

8 2 1,7 8

3 2,5 11 11

5 4,3 15 15

9 7,7 19,5 20

14 12 24 25

32 22 18,8 31

40 34 29 39

50 53 45,3 48,5

65 91 77,8 64

80 138 118 79

100 217 185,5 98,5

Valve serie 1000

Seat

dia

me

ter

(mm

)

Standard CV and KV

Seat

dia

me

ter

(mm

)

Seat

dia

me

ter

(mm

)

Seat

dia

me

ter

(mm

)

141

Page 6: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

4/20

Serie 3000

CV (gpm)

KV (m3/h)

Seat diameter (mm)

stroke (mm)

2,5 2,1

Ø 10 20 2 1,7

1,5 1,3

2,5H 2,1H Ø 10

HR 20 2H 1,7H

1,5H 1,3H

1 0,85

Ø 6 20 0,8 0,68

0,5 0,43

1H 0,85H Ø 6

HR 20 0,8H 0,68H

0,5H 0,43H

0,3 0,26

Ø 4 15

0,2 0,17

0,1 0,09

0,08 0,068

0,06 0,051

0,05 0,043

Ø2 10 0,03 0,026

0,02 0,017

0,01 0,009

FLOW COEFFICIENTS REDUCED (LOWFLOW)

-Flow characteristic (linear, Equalpercentage) -Type sealing metallic. -HR (High rangeability) - 1:50

MVP serie 3000

CV (gpm)

KV (m3/h)

Seat diameter (mm)

stroke (mm)

0,3 0,26

Ø 4 6

0,2 0,17

-Flow characteristic (linear)

Valve serie

2000—800

CV (gpm)

KV (m3/h)

Seat diameter (mm)

2,5 2,1

Ø 10 2 1,7

1,5 1,3

2,5H 2,1H Ø 10

HR 2H 1,7H

1,5H 1,3H

1 0,85

Ø 6 0,8 0,68

0,5 0,43

1H 0,85H Ø 6

HR 0,8H 0,68H

0,5H 0,43H

0,3 0,26

Ø 4 0,2 0,17

0,1 0,09

-stroke 20 mm -Flow characteristic (linear, Equalpercentage) -Type sealing metallic. -HR (High rangeability) - 1:50

Serie 3500

CV (gpm)

KV (m3/h)

Seat diameter (mm)

stroke (mm)

0,3 0,26

Ø 4,02 15 0,2 0,17

0,1 0,09

0,08 0,068

Ø3,02 15 0,06 0,051

0,05 0,043

0,03 0,026

Ø2,02 10 0,02 0,017

0,01 0,009

-Flow characteristic (linear, Equalpercentage) -Type sealing metallic. -HR (High rangeability) - 1:50

142

Page 7: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

5/20

Control characteristics

PLUG AND CONTROL SPECIFICATIONS

The plug is the most important internal component of a control valve as it modifies the flow and makes the seal with its seat. The control characteristic is determined by the variation of the flow rate in relation to the plug stroke, and it is obtained by shaping it adequately

Linear (red curve) This plug allows the linearity between the stroke and flow rate; therefore, it is proportional to the opening degree of the valve. It is used when the operating differential pressure does not undergo important variations or in processes with limited flow rate variations.

Equipercentage (blue curve) With this plug we obtain a constant percentage of flow rate increase for an equal increase in the opening stroke. The valve sup-

plies most of the flow rate in the last opening phase. It is used when the flow rate is extremely variable or when the differential

pressure undergoes important variations.

Quick opening (yellow curve) With this plug we obtain a quick increase in flow rate. Normally, it is used for on/off services.

143

Page 8: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

6/20

Plug example

PLUG AND CONTROL SPECIFICATIONS

Parabolic plug with equipercentage characteristic. Single upper guide.

Parabolic plug with linear characteristic. Single upper guide.

Parabolic plug with equipercentage characteristic. Double upper and lower guide.

144

Page 9: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

7/20

Plug example

PLUG AND CONTROL SPECIFICATIONS

Parabolic plug with linear characteristic. Double upper and lower guide.

V-port plug with linear characteristic.

3-way MIXING valve

3-way DIVERTER valve with the following limitations on the maxi-

mum operating differential pressure (Δp / recommended values):

DN15/25 Δp ≤ 10 bar

DN32/50 Δp ≤ 5 bar

DN65/80 Δp ≤ 3 bar

DN100 Δp ≤ 1.5 bar

Upper guide and in seat.

V-port plug with linear characteristic.

Correct 3-way DIVERTER valve Upper guide and in seat.

145

Page 10: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

8/20

Plug example

PLUG AND CONTROL SPECIFICATIONS

Parabolic plug with linear or equipercentage characteristics complete with compact silencer. Attenuation of maximum sound level about - 10/12 dBA. Upper and lower guide or only upper guide

Micro-flow (needle) plug with linear or equipercentage characteristic. Upper guide.

Plugs equipped with only the upper guide are used in 2-way valves when the operating differential pressure does not exceed 10-12 bar and in micro-flow valves. Plugs equipped with both upper and lower guides guarantee maximum resistance and increased stability to static and dynamic stress of the flow. They are required in 2-way valves when the operating differential pressure exceeds 10-12 bar and the temperatures involved are high.

146

Page 11: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

9/20

Serie EURO, 800/803 e 2000/2003

PRESSURE - TEMPERATURE BODY MATERIAL

Maximum pressure and temperature values allowed in relation to the material of the valve body.

Body material

TEMPERATURE (°C) Rating

from - 196 to < -5 -5 20 100 120 150 200 250 300 350

GS400-12/15 (GGG 40)

PN16 - - - 16 bar

16 bar

16 bar

15 bar

14 bar

14 bar

12 bar

10 bar

8 bar

A216WCB PN40 - - - 40 bar

40 bar

40 bar

40 bar

40 bar

35 bar

32 bar

28 bar

24 bar

CF8M - CF3M PN40 40 bar 40 bar

40 bar

40 bar

40 bar

40 bar

35 bar

32 bar

28 bar

24 bar

A216WCB ANSI300 - - - 51 bar

51 bar

46,4 bar

45,9 bar

45,1 bar

43,9 bar

41,8 bar

38,9 bar

36,9 bar

CF8M - CF3M ANSI300 49,6 bar 49,6 bar

49,6 bar

42,3 bar

40,8 bar

38,5 bar

35,8 bar

33,5 bar

31,6 bar

30,4 bar

Serie 3000/3003

Body material

Rating TEMPERATURE (°C)

from - 196 to < -30 -30 20 100 120 150 200 250 300 350

AISI 316L

PN40 40 bar 40 bar

40 bar

40 bar

40 bar

40 bar

35 bar

32 bar

28 bar

24 bar

PN63 63 bar 63 bar

63 bar

59,7 bar

57,5 bar

54,3 bar

50,1 bar

47,1 Bar

43,5 Bar

41,7 bar

PN100 100 bar 100 bar

100 bar

94,7 bar

91,3 bar

86,1 bar

79,5 bar

74,7 bar

69 bar

66,1 bar

ANSI150 19 bar 19 bar

19 bar

19 bar

16 bar

14,8 bar

13,6 bar

12 bar

10,2 bar

8,4 bar

ANSI300 49,6 bar 49,6 bar

49,6 bar

42,3 bar

40,8 bar

38,5 bar

35,8 bar

33,5 bar

31,6 bar

30,4 bar

ANSI600 99,3 bar 99,3 bar

99,3 bar

84,5 bar

81,5 bar

77,1 bar

71,2 bar

66,7 bar

63,1 bar

61 bar

147

Page 12: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

10/20

Serie EURO, 800/803

TEMPERATURE USE LIMITS VALVE TYPE

The following tables indicate the maximum temperature values of the operating fluid: of the type of valve, type of seal between seat and plug, type of intermediate body and of the seal on the stem. Rolled stem with final roughness 0.15 micron

Trim plug - seat

Stem seal (Packing type)

PTFE (LTS - LTS+OR - DTV)

PTFE +

grafite (STD+OR)

PTFE/CG +

grafite (STD/S+OR)

grafite3 (HTS/S)

soft (PTFE insert)

180 °C ---- ---- ----

soft (PTFE/CG insert)

180 °C 190 °C 190 °C ----

Soft HPP (PEEK insert)

180 °C 200 °C 205 °C ----

metallic4 metallic + stellite4

180 °C 200 °C 205 °C 250 °C

serie 2000/2003, 3000/3003 – intermediate body standard

Trim plug - seat

Stem seal (Packing type)

PTFE (LTS - LTS+OR - DTV)

PTFE +

grafite (STD)

PTFE/CG +

grafite (STD/S)

grafite (HTS/S)

soft (PTFE insert)

180 °C ---- ---- ----

soft (PTFE/CG insert)

180 °C 190 °C 190 °C ----

soft HPP

180 °C 205 °C 210 °C ----

metallic metallic + stellite4

180 °C 205 °C 210 °C 250 °C

3- Special, only upon request, valves series 800/803 without actuator 4- Not available for EURO series valve

148

Page 13: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

11/20

serie 2000/2003, 3000/3003 – intermediate body with extended bellows

TEMPERATURE USE LIMITS VALVE TYPE

Trim plug - seat

Stem seal (Packing type)

PTFE (LTS - LTS+OR - DTV)

PTFE +

grafite (STD)

PTFE/CG +

grafite (STD/S)

grafite (HTS/S)

soft (PTFE insert)

180 °C ---- ---- ----

soft (PTFE/CG insert)

180 °C 190 °C 190 °C ----

Soft HPP (PEEK insert)

210 °C 210 °C 210 °C ----

metallic metallic + stellite

280 °C 300 °C 300 °C 350 °C

serie 2000/2003, 3000/3003 – finned intermediate body

Trim plug - seat

Stem seal (Packing type)

PTFE (LTS - LTS/S - DTV)

PTFE +

grafite (STD)

PTFE/CG

+ grafite (STD/S)

grafite (HTS/S)

metallic metallic + stellite4

280 °C 300 °C 300 °C 350 °C

Vacuum packing (DTV) Pressure use limits ≥ 1 mbar (absolute)

149

Page 14: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

12/20

Type of actuator and thrust sections

DIAPHRAGM SERVO CONTROL DIFFERENTIAL PRESSURE

The servo control or actuator transforms the pneumatic signal into an even and linear movement of the valve plug. It also posi-tions the valve plug when the control signal varies. The essential characteristic of the actuators of the control valves, unlike the on/off valves, is their capability to respond to finite signal variations in a finite way .

Actuators with contrast spring contained in the heads and neoprene flexible membrane with nylon reinforcement

DIRECT The increase in air pressure on the membrane moves the stem downwards.

INVERSE (/I) The increase in air pressure on the membrane moves the stem upwards.

* On request 1= At the working thrust needs to be subtracted the force of the spring in use

Actuator Size Thrust section (cm2) Thrusts (N/psi)

S140 57 39

130 90 S200

S275 277 191

S340 473 326

S430 710 490

S430 doppio 1420 980

S600 * 1850 1276

DOUBLE EFFECT (/DE)

The increase in air pressure on the membrane moves the stem in both direction.

150

Page 15: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

13/20

MAX DIFFERENTIAL PRESSURE CONTROL VALVES

The following table indicates the maximum differential pressure allowed for NC valves (Normally Closed), in relation to the diameter of the seat and to the size of the corresponding actuator:

Table of maximum pressure drop valves, NC - (NORMALLY CLOSED)

Seat diameter - mm

Actuator

diameter Spring

Range Supply

6-4

(1/4”) 10

(3/8”) 15

(1/2”) 20

(3/4”) 24

(1”) 32

(1” ¼) 38

(1” ½) 50

(2”) 64

(2” ½) 71

(3”) 95

(4”) 110

(5”) 130

(6”)

S200

3-15 psi 20 psi 88,0 33,0 14,55 8,05 5,75 3,2 2,2 1,2 - - - - -

6-18

6-30 psi

20 psi

40 psi 100,0 65,0 29,0 16,0 11,5 6,5 4,5 2,5 - - - - -

12-35 psi 40 psi 100,0 100,0 58,0 32,0 23,0 13,0 9,0 5,0 - - - - -

16-40 psi 45 psi 100,0 100,0 78,0 44,0 31,0 17,0 12,5 7,0 - - - - -

S275

3-15 psi 20 psi - 69,0 31,5 17,5 12,2 7,0 5,0 2,7 - - - - -

6-18

6-30 psi

20 psi

40 psi - 100,0 63,0 35,0 24,5 14,0 10,0 5,5 - - - - -

9-15

9-18 psi 20 psi - 100,0 93,0 53,0 37,0 21,0 15,0 8,5 - - - - -

12-30 psi 40 psi - 100,0 100,0 70,0 49,0 28,0 20,0 11,0 - - - - -

S340

3-15 psi 20 psi - - - - - 12,0 8,5 4,7 3,0 2,2 1,2 - -

6-18

6-30 Psi

20 psi

40 psi - - - - - 24,0 17,0 9,5 6,0 4,5 2,5 - -

12-30 psi 40 psi - - - - - 48,0 34,0 19,0 12,0 9,0 5,0 - -

15-33 psi 45 psi - - - - - 60,0 42,0 24,0 15,0 12,0 6,5 - -

18-36 psi 45 psi - - - - - 63,0 51,0 29,0 18,0 14,5 8,0 - -

3-15 psi 20 psi - - - - - - - 7,2 4,5 3,5 2,0 1,5 1,1

6-18

6-30 Psi

20 psi

40 psi - - - - - - - 14,5 9,0 7,0 4,0 3,0 2,2

12-30a)

psi 40d) psi - - - - - - - 29,0 18,0 14,0 8,0 6,0 4,4

15-33b)

psi 45e) psi - - - - - - - 37,0 22,0 18,0 10,0 7,5 5,5

18-36c)

psi 45e) psi - - - - - - - 44,0 27,0 22,0 12,0 7,8 6,6

Valve seat 5”-6” a) 12-46 psi, b) 15-49 psi, c) 17-53 psi Valve seat 5”-6” d) 52 psi, e) 58 psi

NOTES

1) The values refer to the condition with actuator supply pressure equal to 0 psi (0 bar). 2) The values indicated must be compared with the nominal pressure of the body and the pressure-temperature diagram. 3) The values can be increased by increasing the initial preload of the springs. 4) The values used in the table are expressed in Bar 5) For DIVERTER pressure drops refer to the values at Page. 145

S43

0

S43

0 d

ou

ble

(mu

ltip

ly v

alu

es

x 2

)

151

Page 16: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

14/20

MAX DIFFERENTIAL PRESSURE CONTROL VALVES

Table of maximum pressure drop valves, NO - (NORMALLY OPEN)

The following table indicates the maximum differential pressure allowed for NO valves (Normally Open), in relation to the diame-ter of the seat and to the size of the corresponding actuator:

Seat diameter - mm

Actuator Diameter

Spring Range Supply 6-4

(1/4”) 10

(3/8”) 15

(1/2”) 20

(3/4”) 24

(1”)

32

(1” ¼)

38

(1” ½)

50

(2”)

64

(2” ½)

71

(3”) 95

(4”) 110

(5”) 130

(6”)

S200 3-15 psi

1.2 bar 88,0 33,0 14,5 8,0 5,7 3,2 2,2 1,2 - - - - -

1,4 bar 100,0 65,0 29,0 16,0 11,5 6,5 4,5 2,5 - - - - -

2,0 bar 100,0 100,0 63,0 42,0 29,0 16,0 11,5 6,5 - - - - -

3.0 bar 100,0 100,0 100,0 63,0 56,0 32,0 22,0 13,0 - - - - -

S275 3-15 psi

1.2 bar - 69,0 31,5 17,5 12,2 7,0 5,0 2,7 - - - - -

1.4 bar - 100,0 63,0 35,0 24,5 14,0 10,0 5,5 - - - - -

2.0 bar - 100,0 100,0 87,0 62,0 35,0 25,0 14,0 - - - - -

3.0 bar - 100,0 100,0 100,0 100,0 63,0 48,0 28,0 - - - - -

S340 3-15 psi

1.2 bar - - - - - 12,0 8,5 4,7 3,0 2,2 1,2 - -

1.4 bar - - - - - 24,0 17,0 9,5 6,0 4,5 2,5 - -

2.0 bar - - - - - 60,0 42,0 24,0 15,0 12,0 6,5 - -

3.0 bar - - - - - 63,0 63,0 47,0 29,0 23,0 13,0 - -

1.2 bar - - - - - - - 7,2 4,5 3,5 2,0 1,5 1,1

3-15 psi

1.4 bar - - - - - - - 14,5 9,0 7,0 4,0 3,0 2,2

2.0 bar - - - - - - - 37,0 22,0 18,0 10,0 7,7 5,5

3.0 bar - - - - - - - 63,0 43,0 35,0 19,0 12,0 10,6

NOTE: The values indicated must be compared with the nominal pressure of the body and the pressure-temperature diagram. The values used in the table are expressed in Bar Conversion table Bar —> PSI 1,2 bar =17,4 psi 1,4 bar =20,3 psi 2,0 bar =29 psi 3,0 bar =43,5 psi

S43

0

S43

0 d

ou

ble

(m

ult

iply

va

lue

s x

2)

152

Page 17: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

15/20

MAX DIFFERENTIAL PRESSURE ON-OFF VALVES

Table of maximum differential pressure of valves VPOO, NC - (NORMALLY CLOSED)

The following table indicates the maximum differential pressure allowed for NC valves (Normally Closed), in relation to the diameter of the seat and to the size of the corresponding actuator:

DN

Actuator Diameter Supply 8 10 15 20 25 32 40 50 65 80 100 125 150 200

S.63/R

6Bar

- - 12 12 8 - - - - - - - - -

S.63 - - On

request On

request 12 8 6 - - - - - - -

S.82/R - - - - - 8 6 - - - - - - -

S.82 - - - - On

request 12 10 6 - - - - - -

S.118 - - - - - On

request On

request On

request 7 5,5 - - - -

S.136 - - - - - - - On

request On

request On

request On

request - - -

S.153 - - - - - - - - - On

request On

request On

request On

request -

S.235 - - - - - - - - - - On

request On

request On

request On

request

NOTE: 1) The values refer to the condition with actuator supply pressure equal to 0 psi (0 bar). 2) The values indicated must be compared with the nominal pressure of the body and the pressure-temperature diagram. 3) The values used in the table are expressed in Bar

Table of maximum differential pressure of valves VPFL, MVP NC - (NORMALLY CLOSED)

The following table indicates the maximum differential pressure allowed for NC valves (Normally Closed), in relation to the diameter of the seat and to the size of the corresponding actuator:

DN

Actuator Diameter Supply 8 10 15 20 25 32 40 50 65 80 100 125 150 200 6

6Bar

S.20 6 - - - - - - - - - - - - - 6

S.32 15 10 - - - - - - - - - - - -

S.50 - - 15 10 6 - - - - - - - - -

S.63 - - 25 18 12 7 - - - - - - - -

S.82 - - - 25 20 15 8 6 - - - - - -

S.118 - - - - - 25 18 15 7 - - - - -

S.136 - - - - - - On

request On

request 14 8 5 - - -

S.153 - - - - - - - - - 12 7,5 3 1,5 -

S.235 - - - - - - - - - On

request On

request On

request On

request 0,5

NOTE: 1) The values refer to the condition with actuator supply pressure equal to 0 psi (0 bar) 2) The values indicated must be compared with the nominal pressure of the body and the pressure-temperature diagram. 3) The values are with plug in PTFE. 4) The values used in the table are expressed in Bar

153

Page 18: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

16/20

AIR CONSUMPTION

Actuator air consumption 2 bar supply CONTROL Valves

Actuator air consumption 6 bar supply VPOO Valves

Actuator (S.) Volume (dm3) Consumption Nl/ciclo (for each cycle of the full stroke)

Section (cm2)

S.63 31,2 0,06 0,4

S.82 53,5 0,11 0,6

S.118 108,4 0,33 2,0

S.136 146,3 0,51 3,1

S.153 183,9 0,64 3,9

S.235 433,7 2,17 13,0

Actuator (S.) Volume (dm3) Consumption Nl/cicle (for each cycle of the full stroke)

Section (cm2)

140 84,9 0,17 0,3

200 191,1 0,38 0,8

275 373,3 0,75 1,5

340 581,1 1,74 3,5

430 stroke 35mm 886,7 3,10 6,2

430 stroke 50mm 886,7 4,43 8,9

430 double stroke 50mm 1773,4 8,87 17,7

600 2189,6 17,52 35,0

154

Page 19: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

17/20

Valve serie

VPFL/FL-VPFL/FF

DN CV KV

15 5 4,3

20 9 7,7

25 14 12

32 22 18,8

40 34 29

50 53 45,3

65 91 77,8

80 138 118

100 217 185,5

125 339 290

150 490 418,8

200 865 739,3

Valve serie

SBS/S - SBS/3

DN CV KV

15 5 4,3

20 8 6,8

25 13 11,1

32 20 17

40 32 27,3

50 50 42,7

65 85 72,6

80 129 110,2

100 203 173,5

125 318 271,8

150 459 392,3

200 811 693,2

Valve serie MVPFL/FL MVPFL/FF

DN CV KV

6 1 0,85

8 2 1,7

10 3 2,5

15 6 5,1

20 9 7,7

25 14 12

Valve serie MVP/S

DN CV KV

6 - -

8 2 1,7

10 3 2,5

15 5 4,3

20 8 6,8

25 13 11,1

FLOW COEFFICIENTS AVAILABLE (CV) On-Off Valves

155

Page 20: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

18/20

FLOW COEFFICIENTS AVAILABLE (CV) Ball Valves

Ball Valve 2 way

DN CV KV

10 6 5,1

15 10 8,5

20 17 21,8

25 26 22,2

32 42 35,9

40 66 56,4

50 103 88

Ball Valve 3 way

DN CV KV

10 6 5,1

15 10 8,5

20 17 21,8

25 26 22,2

32 42 35,9

40 58 49,6

50 93 79,5

Ball sample

CH9 VSP/VSL 2V - DN10 (3/8”) - 25 (1”) VSP/VSL 3V - DN10 (3/8”)

CH14 VSP/VSL 2V - DN32 (1”1/4) - 50 (2”) VSP/VSL 3V - DN15 (1/2”) - 40 (1”1/2)

CH17 VSP/VSL 3V - DN50 (2”)

156

Page 21: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

19/20

GENERAL SALES CONDITIONS

1. INFORMATION DATA

Data, information, and illustrations found in the catalogue are intended to represent the various types of products but are not binding. BUROCCO INDUSTRIAL VALVES S.r.l. reserves the right to make any modifications and improvements, based on experience, without prior notice. Overall dimensions and weights are purely indicative and not binding. Gauges, diame-ters, and drilling of the flanges comply with EN or ANSI standards

2. ORDER

BUROCCO INDUSTRIAL VALVES S.r.l. reserves the right to reject the order if the conditions contained therein are different from those agreed and/or indicated in the offer. The order becomes binding only after being accepted by BUROCCO IN-DUSTRIAL VALVES S.r.l. with written confirmation. If this is not received within 1 day, the order will be deemed to be ac-cepted in full. Any clause or condition made by the customer in the request or order is not valid and not applicable (even partially) if not accepted in writing . 3. SPECIAL PRODUCTS

Once the order has been confirmed, cancellations of orders of special items and/or standard products modified upon specific request of the customer will not be accepted . 4. ACCEPTANCE

The purchaser declares to have verified the suitability of the product in relation to its intended use assuming all risks and liability resulting from its improper use . 5. TESTS

Every product is tested according to the current standards (UNI-EN 1349, UNI-EN 12266-1:2003, ANSI B16.34 ). 6. DOCUMENTATION

The documentation must be requested at the time of ordering; declarations of conformity, technical sheets, use and maintenance manuals, certifications of conformity 97/23/EC according to P.E.D. directive, certifications of conformity 94/9/EC according to ATEX directive, and test reports according to UNI EN 10204 2.2 will be supplied free of charge. Test reports according to UNI EN 10204 3.1 or any other specific document will be charged at cost. 7. DELIVERIES

Deliveries will be made according to the current availability, considering production and construction requirements and in compliance with the terms agreed (according to INCOTERMS 2010). In the event of delayed delivery, the customer is not entitled to cancel the order if the delay is due to force majeure causes or postponements not attributable to BUROCCO INDUSTRIAL VALVES S.r.l. However, delays will be communicated accordingly. 8. PENALTIES

Penalties are valid only if expressly accepted in writing by BUROCCO INDUSTRIAL VALVES S.r.l. and include any damage caused by delay in delivery. 9. PACKAGING

Standard packaging is included in the price. Special packaging, crates or with special protective enclosures are non-returnable and will be invoiced at cost, unless otherwise agreed. 10. TRANSPORT

Even if sold carriage free, the goods travel at the risk of the purchaser. In the event the order does not specify the ship-ment terms, BUROCCO INDUSTRIAL VALVES S.r.l. will act according to its experience (prior approval of the customer) with-out assuming any liability.

157

Page 22: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BU

RO

CC

O IN

DU

STRIA

L VA

LVES srl V

IA N

OV

EIS, 33

– 13

86

7 P

RA

Y (BI) - ITA

LY b

uro

cco@

bu

rocco

.it —w

ww

.bu

rocco

.it Tel.: +3

9 0

15

76

.72

.78

—Fax: +3

9 0

15

76

.71

.36

Burocco reserves the right to make improvements without prior notice 07/14

20/20

11. ITEMS RETURNED BY THE CUSTOMER

Any material returned must be previously required in writing and authorised. Nevertheless, BUROCCO INDUSTRIAL VALVES S.r.l. reserves the right to accept or reject the returned material in the event this is damaged, non-compliant with the appearance or evidently tampered with. In any case, the material to be returned cannot refer to supplies made four months prior to the date of the return request. Returns of customised products will not be accepted. 12. REPAIRS/MAINTENANCE

Goods dispatched for REPAIRS/MAINTENANCE must be requested in written and authorised. The sent form must be then filled up in every single part, as for the RECLAMATION of the material, and authorised. Nevertheless, BUROCCO INDUS-TRIAL VALVES S.r.l. reserves the right to accept or reject the returned material in the event this is not duly reclaimed and non-compliant with the appearance. 13. PAYMENTS

Payments must be addressed to BUROCCO INDUSTRIAL VALVES S.r.l., operational headquarters in Pray (BI). In compliance with Italian L. Decree n. 192 dated 09/11/2012 relating to action to combat delays in payment in commercial transactions, We inform you that for all shipments made from 01/01/2013, the payment terms will expire within maximum "60 dd in-voice date end of month", unless otherwise agreed between the parties in writing. Moreover, the new directive sets forth that once the payment term has expired, default interests are automatically triggered, which correspond to the interest rate applied by the ECB increased by 8 percentage points (ECB rate +8%), late payment interest is automatically triggered, corresponding to the interest rate applied by the European Central Bank increased by 8 percentage points (ECB+8%), in addition to the minimum amount of € 40.00 by way of compensation for damages, without prejudice to the possibility of charging further damages for service costs (legal expenses) for recovery of the debt and bank costs. 14. WARRANTY - LIABILITY

BUROCCO INDUSTRIAL VALVES S.r.l. guarantees that the products supplied are free from defects in materials (other than hidden defects), construction and operation for a duration of 24 months from the date of supply (in compliance with art. 1519, sec. II, chapter I, title III, book IV C.C. and subsequent European Directive 1999/44/EC). No delay in installation can justify requests for extensions of the warranty, unless previously agreed . The warranty does not include any liability for any damage caused to persons and/or property, nor any damage caused by incorrect installation of the product due to negligence, failure to comply with the rules and limits of operation or inappropriate conditions of transport and/or stor-age. Any claims must be notified in writing within eight days from the receipt of the goods, stating the type of defect f o u n d ; c l a i m s c a n n o t i n t e r r u p t t h e e s t a b l i s h e d t e r m s o f p a y m e n t . No claim can be considered if the customer has not complied with its contractual obligations or the product shows evi-dent signs of tampering or faults due to improper installation or operation, or to use (even if only occasional) in operating conditions exceeding the values indicated for each product. In the event the product is intended for food use or use with dangerous fluids (explosive, flammable, toxic and oxidant), it is necessary to contact the manufacturer before use. BU-ROCCO INDUSTRIAL VALVES S.r.l.'s liability shall be limited solely to replacing any parts found with construction faults attributable to the manufacturer, following return of the parts carriage paid. No claim for damages attributable to these items will be recognised. This warranty replaces any other warranty requested by the customer. The standard paint ap-plied by BUROCCO INDUSTRIAL VALVES S.r.l. on the product has the sole purpose of protecting the valves during trans-port and the storage period with a maximum duration of 12 months from the date of delivery. No guarantee is given for the suitability and durability of this paintwork in specific conditions of use (temperature, humidity etc.). In all cases, the paintwork, even if done according to the customer's specifications, is considered a wearing part and its durability is, there-fore, not guaranteed. 15. RESERVATION OF TITLE

Pursuant to Article 4 of European Directive 2000/35 CE, all goods supplied by BUROCCO INDUSTRIAL VALVES S.r.l. shall remain the exclusive property thereof until complete payment of the amount due. In case of default in whole or in part, BUROCCO INDUSTRIAL VALVES S.r.l. may claim ownership wherever the goods may be, even if incorporated in goods that are the property of the purchaser or of third parties. 16. DISPUTES

For any dispute or disagreement concerning the conditions of sale, in derogation of the provisions of Book I, Section III of the Italian Civil Procedure Code, any competing jurisdiction is excluded and the Court of Biella shall be deemed to have sole competence. For anything that is not expressly agreed between the parties, current Italian legislation shall apply, together with the customary practices of the engineering industry recognised by the Chamber of Commerce of Biella. Any other dispute concerning or connected with an international sale contract, including those relating to its interpretation, validity, execution and termination, shall be subject to formal arbitration, according to the ordinary or fast arbitration procedure (depending on the value), in compliance with the Regulations of the International Arbitration Chamber of Mi-lan. The language of arbitration shall be Italian.

158

Page 23: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

23

Page 24: Technical Manual - BUROCCO · BUROCCO INDUSTRIAL VALVES srl . VIA NOVEIS, 33 – 13867 PRAY (BI) -ITALY burocco@burocco.it —  Tel.: +39 015 76.72.78 — Fax: +39 015 76.71.36

BUROCCOINDUSTRIAL VALVES S.r.l.

Via Noveis, 33 - 13867 Pray (BI) ItalyTel. +39 015 767 278 - Fax +39 015 767 136 [email protected] - P. IVA: 02526580028

Copyright © 2014 BUROCCO INDUSTRIAL VALVES S.r.l.97/23/EC -PED 94/9/EC - ATEX

Rev 03-16

24