1. Report No. 2. Government Accession No. Technical ll::1r,nrto; Center Texas T 1 Cii\.•i Institute, TECHNICAL REPORT STANDARD TITLE PAC! 3. Recipient's Catalog No. EFFECTS OF TEMPERATURE, WIND AND HUMID IT:'{ ON SELECTED CURING MEDIA 7. Author! s) Larry D. Groth, A. H. Meyer, P.E., W. B. Ledbetter. P.E. 9, Performing Organization Name and Address Texas Transportation Institute Texas A&M University College Station, Texas 77843 August, 1974 6. Performing Organization Code 8. Performing Organization Report No. Research Report 141-3 10. Work Unit No. 11. Contract or Grant No. Research Study 2-6-70-141 13. Type of Report and Period Covered 12. Sponsoring Agency Name and Address Interim - September, 1969 Texas Highway Department August, 1974 11th & Brazos Austin, Texas 78701 14. Sponsoring Agency Code 15. Supplementary Notes Research performed in cooperation with DOT, FHWA. Research Study Title: Quality of Portland Cement Concrete Pavement as Related to Environmental Factors and Handling Practices During Construction. 16. Abstract A portland cement concrete pavement should possess various qualities to be considered effective. Most important to the driving public is a smooth ride. But'the pavement should also be durable and structurally sound, and should maintain surface qualities required for traffic safety with respect to skid resistance. Proper consolidation, finishing, and cur- ing are of particular importance in the production of high quality concrete. This research study summarizes the results of two laboratory studies and one field study conducted to investigate the curing component in producing high quality concrete pavements. The following conclusions were reached: 1. All of the curing methods considered (involving tht use of some curing compound) proved to be effective. 2. In these tests the water soluble linseed oil curi'ng compound (WSLO) was as effective as the white pigmented compound (WPC) in retaining moisture in the concrete. 3. Consistently, both WPC and WSLO tended to retain moisture more effectively than monomolecular film followed by white pigmented curing compound (MMF + WPC). 4. Applying MMF in two small applications instead of one large single application retained moisture more effectively except at low relative humidities. (continued on back) 17. Key Words 18. Distribution Statement Concrete, Concrete Pavements, Concrete Construction, Concrete Finishing, Curing, Temperature, Wind, Humidity, Evaporation, Curing Compound 19. Security Ciani f. (of this report) 20. Security Clauif. (of this page) 21. No. of Pages 22. Price Unclassified Unclassified 65 Form DOT F 1700.7 ca-ul

Upload: hangoc

Post on 20-Mar-2018

234 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

1. Report No. 2. Government Accession No.

Technical ll::1r,nrto; Center Texas T 1 Cii\.•i -~:·~r.;Uon Institute,

TECHNICAL REPORT STANDARD TITLE PAC!

3. Recipient's Catalog No.

~4'.~T~i~tl'e_a_n~d~S~ub~t~itTie--------------~~----------------------------~S-.~R~e-po_r_t~D-at-e----------·-----------­

EFFECTS OF TEMPERATURE, WIND AND HUMID IT:'{ ON SELECTED CURING MEDIA

7. Author! s)

Larry D. Groth, A. H. Meyer, P.E., W. B. Ledbetter. P.E.

9, Performing Organization Name and Address

Texas Transportation Institute Texas A&M University College Station, Texas 77843

August, 1974 6. Performing Organization Code

8. Performing Organization Report No.

Research Report 141-3 10. Work Unit No.

11. Contract or Grant No.

Research Study 2-6-70-141

1'-:'::--:-----------:-:-----:-~:---------------------------.......l 13. Type of Report and Period Covered 12. Sponsoring Agency Name and Address Interim - September, 1969

Texas Highway Department August, 1974 11th & Brazos Austin, Texas 78701 14. Sponsoring Agency Code

15. Supplementary Notes Research performed in cooperation with DOT, FHWA. Research Study Title: Quality of Portland Cement Concrete Pavement as Related to Environmental Factors and Handling Practices During Construction.

16. Abstract

A portland cement concrete pavement should possess various qualities to be considered effective. Most important to the driving public is a smooth ride. But'the pavement should also be durable and structurally sound, and should maintain surface qualities required for traffic safety with respect to skid resistance. Proper consolidation, finishing, and cur­ing are of particular importance in the production of high quality concrete. This research study summarizes the results of two laboratory studies and one field study conducted to investigate the curing component in producing high quality concrete pavements.

The following conclusions were reached: 1. All of the curing methods considered (involving tht use of some

curing compound) proved to be effective. 2. In these tests the water soluble linseed oil curi'ng compound

(WSLO) was as effective as the white pigmented compound (WPC) in retaining moisture in the concrete.

3. Consistently, both WPC and WSLO tended to retain moisture more effectively than monomolecular film followed by white pigmented curing compound (MMF + WPC).

4. Applying MMF in two small applications instead of one large single application retained moisture more effectively except at low relative humidities.

(continued on back) 17. Key Words 18. Distribution Statement Concrete, Concrete Pavements, Concrete Construction, Concrete Finishing, Concret~ Curing, Temperature, Wind, Humidity, Evaporation, Curing Compound

19. Security Ciani f. (of this report) 20. Security Clauif. (of this page) 21. No. of Pages 22. Price

Unclassified Unclassified 65

Form DOT F 1700.7 ca-ul

Page 2: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

5. Evaporation rates measured experimenta.lly do not give the same trends indicated by the Portland Cement Association (PCA) chart.

6. The results of this research program indicate that the use of monomolecular film during construction could be valuable in gaining time before final finishing, of the surface.

Page 3: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

EFFECTS OF TEMPERATURE, WIND AND HUMIDITY ON

SELECTED CURING MEDIA

by

Larry D. Groth

A. H. Meyer, P.E.

W. B. Ledbetter, P.E.

Research Report 141-3

Quality of Portland Cement Concrete Pavement as Related to Environmental Factors and Handling Practices During Construction

Research Study 2-6-70-141

Sponsored by

The Texas Highway Department

In Cooperation with the

U. S. Department of Transportation Federal Highway Administration

August, 1974

TEXAS TRANSPORTATION INSTITUTE Texas A&M University

College Station, Texas

Page 4: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

FOREWORD

The information contained herein was developed on Research Study

2-6-70-141 titled "Quality of Portland Cement Concrete Pavement as Related

to Environmental Factors and Handling Practices During Construction," in

a cooperative research program with the Texas Highway Department and the

Federal fiighway Administration. The primary purpose of this study is to

develop methods whereby the handling of portland cement concrete paving

mixtures during construction can be improved.

This is the third report to be issued on this study. The others are:

Research Report 141-1, "Laboratory Study of Effects of Environment

and Construction Procedures on Concrete Pavement Surfaces," November 1972.

Research Report 141-2, "First Progress Report on Concrete Experimental

Test Sections in Brazos County, Texas," August 1973.

ii

Page 5: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

.1\C:KNOWI.ImCI•:MI•:NTS

The authors wish to acknowledge the assistance by the advisory com­

mittee for this study. They provided valuable guidance in the formulation

of the research plan. The members are: (a) Texas Highway Department

personnel -Mr. Steve Salek, Study Contact Representative; Mr. W. E. Elmore,

Materials and Test Division Representative; Mr. B. R. English, Bridge

Division Representative; and Mr. T. R. Kennedy, Planning and Research

Division Representative; and (b) Federal Highway Administration personnel -

Mr. Lee Gibbons, Division Representative. The authors wish to acknowledge the

assistance of the following personnel in gathering and summarizing data:

Mr. Sidney Greer, Mr. Leonard Ingram, Mr. Walt Lehmann, Mr. Joe Haynes,

and Mr. M. B. Robertson.

The contents of this report reflect the views of the authors who are

responsible for the facts and the accuracy of the data presented herein.

The contents do not necessarily reflect the official views or policies of

the Federal Highway Administration. This report does not constitute a

standard, specification, or regulation.

iii

Page 6: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

ABSTRACT

A portland cement concrete pavement should possess various qualities

to be considered effective. Most important to the driving public is a

smooth ride. But the pavement should also be durable and structurally

sound, and should maintain surface qualities required for traffic safety

with respect to skid resistance. Proper consolidation, finishing, and cur­

ing are of particular importance in the production of high quality concrete.

This research study summarizes the results of two laboratory studies and

one field study conducted to investigate the curing component in producing

high quality concrete pavements.

The following conclusions were reached:

1. All of the curing methods considered (involving the use of some

curing compound)" proved to be effective.

2. In these tests the water soluble linseed oil curing compound

(WSLO) was as effective as the white pigmented compound (WPC) in retaining

moisture in the concrete.

3. Consistently, both WPC and WSLO tended to retain moisture more

effectively than monomolecular film followed by white pigmented curing

compound (MMF + WPC).

4. Applying MMF in two small applications instead of one large single

application retained moisture more effectively except at low relative

humidities.

5. Evaporation rates measured experimentally do not give the same

trends indicated by the Portland Cement Association (PCA) chart.

6. The results of this research program indicate that the use of

iv

Page 7: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

monomolecular film during construction could be valuable in gaining time

before final finishing of the surface.

Key Words: Concrete, Concrete Pavements, Concrete Construction, Concrete

Finishing, Concrete Curing, Temperature, Wind, Humidity,

Evaporation, Curing Compound.

v

Page 8: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE OF CONTENTS

FOREWORD . • .•

ACKNOWLEDGEMENTS

ABSTRACT

TABLE OF CONTENTS.

LIST OF FIGURES.

LIST OF TABLES

CHAPTER

1. INTRODUCTION AND SUMMARY • .

1.1 General Remarks ••.

1.2 Purpose of the Investigation.

1. 3 Scope .

1. 4 Conclusions

1.5 Recommendations for Implementation ..

2. BACKGROUND .

2.1 Curing. .

2.2 Plastic Shrinkage Cracking.

3. EXPERIMENTAL METHODS AND PROCEDURES.

3.1 General ..

3.2 Evaporation Rate Data

4. RESULTS AND DISCUSSION

4.1

4.2

4.3

General . . . • .

Laboratory Summer 1971. •

Laboratory January 1973 •

vi

..

. . . .

Page

ii

iii

iv

vi

viii

xi

1

1

1

1

2

2

4

4

6

10

10

10

14

14

14

21

Page 9: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE OF CONTENTS (CONT'D.)

4.4 Field Study - Van Horn, September 1973 •.

4.5 Comparison of Evaporation Rates

4.6 Construction Time Consideration

5. APPENDIX

5.1 Discussion of Variables

Laboratory Procedures •

Field Procedures •...

5.2

5.3

5.4

5.5

Tabulated and Plotted Test Results.

References •.

vii

Page

26

30

30

36

38

39

39

54

Page 10: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Figure

2-1

2-2

3-1

4-1

4-2

4-3

4-4

4-5

4-6

LIST OF FIGURES

Film Forming Molecules Properly Oriented on the Surface of Bleeding Water (Cordon and Thorpe Ref. 8) ••• . . Effect of Concrete and Air Temperatures, Relative Humidity, and Wind Velocity on the Rate of Evaporation of Surface Moisture from Concrete (PCA Ref. 2) • • • • • • • ••••

Concrete Slab Setup • • . . . . . . Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 73°F, Relative Humidity of 25%, and Wind Velocity of 8-10 mph . . . • . . • . . • . . . . . . • . . . .

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Velocity of 8-10 mph • • • • • • • • • • . • • • • • • •

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Velocity of 8-10 mph • • • . • • • • • • • • • • • •

Effect of Curing Method of the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 73°F, Relative Humidity of 25%, and Wind Velocity of 18-20 mph •••••••••••••••••

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Velocity of 18-20 mph. • • • • • • • • • • • • • •

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Velocity of 18-20 mph. • • • • • • • • • • • • • •

. . .

. . .

4-7 Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 51°F, Relative Humidity of 23%, and Wind Velocity of 8-10 mph • • • • • • • • • • • • • . • • • • • • • • •

viii

Page

7

9

12

15

16

17

18

19

20

22

Page 11: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Figure

4-8

4-9

4-10

4-11

LIST OF FTC:URES (CONT'D)

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 57°F, Relative Humidity of 50%, and liTind Velocity of 8-10 mph. • • • • • • • . . . . . . • • • • 8 • •

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Velocity of 8-10 mph.. • . • • • • . . • • . • . • . • • . • .

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Velocity of 8-10 mph. • • • . • • • . . . • • . . . . • . • •

Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 80-95°F, Relative Humidity of 10-25%, and Wind Velocity of 0-10 mph. • • . . • • • . • • • . • . . • • • •

4-12 Effect of Temperature on the Evaporation of Water from the Surface of the Concrete Slabs Maintaining Constant Curing Method (MMF(l) + WPC) and Wind Conditions of 8-10 mph. • • • • •• . . . . . . . . . . . . .

4-13 Effect of Temperature on the Evaporation of Hater from the Surface of the Concrete Slabs Maintaining Constant Curing Method (WPC) and Wind Conditions (8-10 mph) . .

5-l Evaporation Rates at the Curing Temperature of 73°F, Relative Humidity of 25%, and Wind Conditions of 8-10 mph.

5-2 Evaporation Rates at the Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Conditions of 8-10 mph.

5-3 Evaporation Rates at the Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Conditions of 8-10 mph.

5-4 Evaporation Rates at the Curing Temperature of 73°F, Relative Humidity of 25%, and Wind Conditions of 18-20 mph

5-5 Evaporation Rates at the Curing Temperature of 100°F, Relative Humidity of 30%, Wind Conditions of 18-20 mph

5-6 Evaporation Rates at the Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Conditions of 18-20 mph

ix

Page

23

24

25

27

28

29

. 43

. 44

. 45

. 46

47

. 48

Page 12: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

LIST OF FIGURES (CONT'D)

Figure Page

5-7 Evaporation Rates at the Curing Temperature of 51°F, Relative Humidity of 23%, and Wind Conditions of 8-10 mph. . . 49

5-8 Evaporation Rates at the Curing Temperature of 57°F, Relative Humidity of 50%, and Wind Conditions of 8-10 mph. . . 50

5-9 Evaporation Rates at the Curing Temperature of 100°F, Rtlative Humidity of 30%, and Wind Conditions of 8-10 mph. . . 51

5-10 Evaporation Rates at the Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Conditions of 8-10 mph. 52

5-11 Evaporation Rates at the Curing Temperature of 80-95°F, Relative Humidity of 10-25%, and Wind Conditions of 0-10 mph . 53

X

Page 13: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Table

3-1

4-1

4-2

4-3

5-1

5-2

L I S'I' OF '1'1\I~I.ES

Variable Code Designations • •

Evaporation Rates

Comparison of Evaporation Rates ••

Delay Time Before Applying White Pigmented Curing Compound .

Curing Methods •

Evaporation Rates in Lbs Per Sq Ft

xi

Page

11

31

33

35

37

40

Page 14: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi
Page 15: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

1. INTRODUCTION AND SUMMARY

1.1 General Remarks

Improvement should be the objective of any practiced art. The con­

struction procedures for Continuously Reinforced Concrete Pavements (CRCP)

have continued to change due to the results obtained from field experience

and laboratory research. However, more information is still required if

the desired improvement of such pavements is to continue. A concrete

pavement must be durable when subjected to natural weathering, chemical

or mechanical means used for ice and snow control, and repeated traffic

loadings. It must maintain surface qualities required for traffic safety

with respect to skid resistance.

Prope~ nn~solidation, proper finishing, proper curing are of

particular importance in the production of h1gn quality concre ave-

ments. This research study is concerned with the curing compout:uL.. in

producing this high quality concrete. This report summarizes the results

of two laboratory studies and one field study conducted to investigate

curing methods.

1.2 Purpose of the Investigation

This study was initiated to develop methods to improve the quality of

portland cement concrete pavements through laboratory examination of

construction practices related to the curing of the concrete pavement.

1.3 Scope

The scope of this investigation included the determination of the

combined effects of wind velocity, air temperature and relative humidity,

type of curing compound, and method of applying the curing compound on

1

Page 16: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

evaporation of water from the surface of the concrete pavement.

1.4 Conclusions

The following conclusions were reached after laboratory and field

evaluations were made on high quality, low slump concrete.

1. All of the curing methods considered (involving the use of some

curing compound) proved to be significantly more effective than using no

cure.

2. In these tests the water soluble linseed oil curing compound (WSLO)

was as effective as the white pigmented curing compound (WPC) in retaining

moisture in the 1!oncrete.

3. Consistently both WPC and WSLO tended to retain moisture more

effectively than monomolecular film followed by WPC (MMF + WPC).

4. Applying MMF in two small applications instead of one large single

application retained moisture more effectively with the exception of low

relative humidities.

5. Evaporation rates measured experimentally do not give the same

trends indicated by the Portland Cement Association (PCA) chart.

6. The results of this research program indicate that the use of

monomolecular film during construction could be valuable in gaining time

before final finishing of the surface.

1.5 Recommendations for Implementation

Based on the findings of this study the following recommendations for

implementation are made:

1. Based on. the tests made in this study it is recommended that the

monomolecular film contim.;e to be used under emergency conditions in order

to gain time.

2

Page 17: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

2. Recommend consideration bv given to expl'rimentnllv pt>rmJttinr,

the use of WSLO as a curing medium for portland cement concrete pavements

to provide field evaluation of this product.

These recommendations for im~lementation are made jointly by the

authors and the study Contact Representative.

3

Page 18: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

2. BACKGROUND

2.1 Curing

The effectiveness of curing has been found to influence the durability

1* and wear resistance of a concrete pavement surface. If the cure is

not applied properly, much of its effectiveness .is lost, and the durability

and wear resistance of the pavement are affected adversely. Therefore,

proper use of curing methods is essential in order to develop high quality

portland cement concrete pavement.

The surface properties of portland cement concrete are greatly affect-

ed by the combined effects of wind velocity, air temperature and relative

humidity, concrete temperature, and type of curing compound.

Properties of concrete such as resistance to freezing and thawing,

strength, water tightness, wear resistance, and volume stability improve

with age as long as conditions are favorable for continued hydration of

the cement. These favorable conditions include the presence of moisture

2 and a proper temperature. Hydration virtually ceases when concrete dries

3 below a relative vapor pressure (relative humidity) of about 0.80. At

this pressure the water-filled capillaries begin to empty. Since

hydration occurs in these water-filled spaces, the effective curing time

is limited to that period during which the relative humidity in the concrete

is above 80 percent. When the concrete is placed in an environment with

a vapor pressure less than that of saturated air, the concrete will lose

water by evaporation. Excessive loss of water by evaporation removes the

moisture necessary for full hydration and improved concrete quality.

*Superscript Arabic numbers refer to corresponding items in the list of references (Sec. 5.5).

4

Page 19: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Therefore, it is necessary to retard the evaporation in some manner.

Concrete sealed against evaporation must initially contain more than about

0.5 gm of water per gm of cement to insure full hydration, since self­

desiccation progressively reduces the space available for hydration products. 3

Membrane cure used as a sealant will not assure full hydration, but may

provide adequate moisture for most of the hydration to occur.

Because of increased labor costs and rapid construction pace, an

increasing number of portland cement concrete pavements are being cured

with membrane-forming curing compounds. Although it is recognized that

moist-curing methods (ponding, sprinkling, wet coverings) best insure

continued cement hydration, membrane-cured concretes have given creditable

4 performance.

The object of membrane curing is to seal the exposed surface with an

impervious membrane in order to prevent the evaporation of the water which

is necessary for the hydration of the cement. In addition, the membrane

may have a white or light color so that it will reflect a considerable

amount of heat from the sun. This helps maintain a more favorable curing

temperature.

Field and laboratory tests have been conducted to evaluate several

combinations of curing and protective treatments for concrete. A study

conducted by the Virginia Highway Research Council evaluated concrete

panels cured with white pigmented liquid membrane (WPC) and white polyethylene,

both with and without subsequent treatments using linseed oil.5

On some

panels a monomolecular film (MMF) was used to reduce evaporation prior to

regular curing. Results showed that a film of linseed oil (in mineral

spirits) continued to be the most satisfactory of the several alternatives

5

Page 20: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

practically available for improved quality. Monomolecular film was used

on days where a high evaporation potential existed, or when there was a

delay in applying the curing compound.

Researchers with the Pennsylvania Department of Highways and Kansas

State University, in their evaluation of concrete protective sealants

and curing compounds, reported that linseed oil (in mineral spirits)

d . 6, 7 prove supen.or. Linseed oil appears to act as a perma-selective

membrane in that it permits the penetration of water into hardened cement

paste at a reduced rate, but prevents the penetration of salts and other

chemicals.

Field and laboratory tests conducted at Utah State University have

demonstrated that a monomolecular film will serve as a suitable evaporation

retarder on the surface of the concrete. A typical material which will

serve as a suitable evaporation retarder is composed of molecules having

a long hydrocarbon chain, which is hydrophobic, attached to a hydrophillic

alcohol terminal group. The long hydrophobic chain orients itself verti­

cally on the surface of the bleed water as illustrated in Figure 2-1.8

If sufficient molecules are present, they form a tightly compressed,

effective film. Water molecules may not possess sufficient energy to

escape through this long chain film and evaporation is significantly

retarded.

2.2 Plastic Shrinkage Cracking

A problem that is affected by surface properties of the concrete

involves plastic shrinkage. Plastic shrinkage cracking is usually asso-

ciated with hot weather concreting and may develop whenever the rate of

evaporation is greater than the rate at which water rises to the surface

6

Page 21: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

MONOLAYER

Fig. 2-1. Film Forming Molecules Properly Oriented on the Surface of Bleeding Water (Cordon and Thorpe Ref. 8).

7

Page 22: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

of the fresh concrete. Plastic shrinkage also occurs in spring and fall

when there are higher winds and lower humidities. 9 Evaporation causes the

concrete to shrink creating tensile stresses at the drying surface.

Liquid-membrane curing compounds are utilized to retard or prevent evap-

oration of moisture from the concrete. Without the application of these

curing compounds, stresses will develop before the concrete has attained

. 2 8 10 adequate strength, resulting in surface crack1ng. ' ' Plastic shrinkage

cracks vary in length from 2 to 3 inches to about 3 to 7 feet. 11 They

h d h 4 . h 10 ave ept s up to 1nc es. Unless cracks are quite shallow and narrow,

they can weaken the pavement, permit penetration of moisture and render

the reinforcement vulnerable to corrosion. 12 Therefore, it is very impor-

tant that a method of curing which retards evaporation to preventing

plastic shrinkage cracks be used.

Field investigations have shown that the characteristics of the

10 concrete do not have a major influence on plastic shrinkage. This has

led to the preparation, by the Portland Cement Association (PCA), of a

chart indicating the interrelationship between air temperature, relative

humidity, concrete temperature, wind velocity, and rate of evaporation

f f . 2 o sur ace mo1sture. This chart, Figure 2-2, is based on data obtained

by Menze1. 10 PCA states that evaporation rates above about 0.2 lbs/sq ft/hr

may increase the possibility of plastic shrinkage cracking and that at

rates below 0.1 plastic shrinkage cracking will probably not occur.2

8

Page 23: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Air temperature, degrees F.

TO USE THIS CHART:

1. ENTER WITH AIR TEMPERATURE, MOVE UP TO RELATIVE HUMIDITY.

2. MOVE RIGHT TO CONCRETE TEMPERATURE. 3. MOVE DOWN TO WIND VELOCITY. 4. MOVE LEFT; READ APPROX. RATE OF

EVAPORATION.

Fig. 2-2. Effect of Concrete and Air Temperatures, Relative Humidity, and Wind Velocity on the Rate of Evaporation of Surface

Moisture from Concrete (PCA Ref. 2)

9

Page 24: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

3. EXPERIMENTAL METHODS AND PROCEDURES

3.1 General

The results given in this report are obtained from data collected

during three investigations. The first was a laboratory study conducted

during the summer, 1971. Three variables included in the evaporation

rate test of this study were: (1) wind, (2) curing environment,

and (3) curing method. The second investigation was again a laboratory

study conducted during January, 1973. Curing environment and curing method

constituted the variables used during this study. Both of these laboratory

studies were conducted at McNew Laboratory at Texas A&M University, The

third set of evaporation data was obtained during a field investigation

near Van Horn, Texas along Interstate Highway 10 in September, 1973. Five

curing methods were tested under the existing natural environmental con­

ditions. Table 3-1 gives the various variables used in the tests with

code designations. Table 5-l gives a complete description of the curing

methods.

3.2 Evaporation Rate Data

All three investigations employed the same methods to determine

evaporation rate. Slabs were made using steel forms (72 x 26 x 8 in.) with

two wooden dividers to separate the concrete into three equal smaller

slabs. These three slabs were, in turn, each subjected into two different

curing treatments on each half. In each of these halves, as illustrated

in Figure 3-1, there was a smaller metal box (6 x 4 x 4 in.) which was

inside a wooden box. These smaller metal boxes were designed to be lifted

out and weighed periodically on a lOlOOO gm capacity balance (sensitivity

0.29 gm), obtaining the loss of weight due to the evaporation of water.

10

Page 25: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE 3-1. Variable Code Designations

Variable Code Symbol

Study Site and Date

Wind

Curing Environment

Curing Method

McNew Laboratory, Summer 1971 McNew Laboratory, January 1973 Van Horn, Texas, September 1973

0 mph 8-10 mph 18-20 mph 0-10 mph (Van Horn)

51°F- 23% R.H. 57°F - 50% R.H. 73°F - 25% R.H. l00°F - 30% R.H. 140°F - 25% R.H. 80-95°F - 10-25% R.H. (Van Horn)

White Pigmented Curing Compound-Resin Based (WPC)

Monomolecular Film (one application) Plus White Pigmented Curing Compound (MMF(l) + WPC)

Monomolecular Film (two applications) Plus White Pigmented Curing Compound (MMF(2) + WPC)

Water Soluble Linseed Oil (WSLO)

No Curing Compound

11

1

2

3

4

5

Page 26: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-c

)(

c

)(

c

-X 0 m

-~ c. E 0 C\J

0""" I OCX)

I

CX) -

12

I

I

z wx oo om 0 3=

en zO::: ww c~ 0> o-3\:c

en w .....J c z <( J:

..0 Cll

.-1 U)

Q.) .w Q.)

H (j

c 0 u

. .-1 I

(Y')

Page 27: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Concrete was placed in the forms in three layers, vibrated in place,

finished with a burlap drag, and the proper cure applied to the surface.

To simulate outdoor conditions in the laboratory investigations, the

slabs were cast in controlled environmental rooms at Texas A&M University.

Wind was generated over the surface of the slabs by use of a squirrel­

cage blower at the end of the slabs. In order to insure uniform air-flow,

two-foot high walls were placed along each side of the slabs to channel

the air. Wind velocity measurements indicated the velocity varied within

± one mph throughout the slab surfaces. Locations of each specific

curing treatment were randomized in the various environments and wind

conditions. Further details are given in Sec. 5.1.

13

Page 28: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

4. RESULTS AND DISCUSSION

4.1 General

The data and results which follow are from the following sources:

Texas A&M in summer of 1971, Texas A&M in summer of 1973, and Van Horn,

Texas in September, 1973. Testing procedures were normalized so that

correlations could be determined between the study sites and variables

tested. The data and figures represented are generally the average values

of two test specimens produced during each investigation. It should be

remembered that only high quality concrete with no discernible bleeding

was used in this research (slump 1 in.± 1/2 in.). The major results are

summarized in the following sections with respect to each study site.

All of the figures were obtained from the data in Table 5-2.

4.2 Laboratory Summer 1971

As discussed in Section 3.2, measurements of water loss from the

surface of the test slabs were recorded until the loss became negligible.

Four types of curing methods were considered -- monomolecular film followed

by white pigmented curing compound[MMF(l) + WPC], water soluble linseed

oil curing compound (WSLO), white pigmented curing compound (WPC), and

no cure (Table 5-l). The following wind velocities were employed:

O, 8-10, 18-20 mph. Three curing conditions were considered: (1) 73°F -

25% RH, (2) 100°F - 30% RH, and (3) 140°F - 25% RH.

Figures 4-1 through 4-6 show results from this study with water loss

being plotted against time. The figures are representative of the effect­

iveness of each curing compound's ability to retain water when exposed to

various environmental conditions. By simple comparison it can be clearly

14

Page 29: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.9

0.8

0.7

- 0.6 ~ I..L.

0 Cf) ......... Cf) 0.5 CD .....J -Cf) Cf) 0 0.4 .....J

0::: w

~ 0.3

0.2

0.1

0

-----NO CURE

MMF(I)+WPC

WSLO

WPC

ENVIRONMENT 73°F- 25% RH

WIND 8-IOmph

LABORATORY SUMMER 1971

10 20 30 40 50

TIME (HOURS)

Fig. 4-1. Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 73°F, Relative Humidity of 25%, and Wind Velocity of 8-10 mph.

15

Page 30: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-._ lL. 0 Cf) ........ Cf) CD _J -Cf) Cf)

9 a:: w t:r 3:

0.9

0.8 --

0.7 NO CURE

0.6

MMF (I) +WPC

0.5

0.4 WPC

WSLO

0.3

0.2 - ENVIRONMENT 100° F- 30% R H

0.1

0

WIND 8-10 MPH

LABORATORY SUMMER 1971

10 20 30 40 50

TIME, (HOURS)

Fig. 4-2. Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Velocity of 8-10 mph,

16

Page 31: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.9

0.8

0.7

- 0.6 ..,_ LL

0 (/') ........ en 0.5 (J) ...J -en en 0 0.4 ...J

a:: w ~ s

0.3

0.2 ~~

0.1

0

ENVIRONMENT 140°F -25% R H

WIND 8-10 MPH

LABORATORY SUMMER 1971

10 20 30 40

Tl ME (HOURS)

NO CURE

MMF(I)+WPC

WPC

WSLO

50

Fig. 4-3. Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Velocity of 8-10 mph.

17

Page 32: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-r-IJ...

0 (/) ......... (/) (l) ..J -(/) (/)

g a:: w r-<( ;:

f.o -

0.9

0.8

0.7

WPC

0.6 MMF(I) + WPC

0.5

WSLO 0.4

0.3

ENVIRONMENT 73°F - 25%RH WIND 18-20 MPH

0.2 LABORATORY SUMMER 1971

0.1

0 L-----~------~-------L-------L------~-------0 10 20 30 40 50

Tl ME (HOURS)

Fig. 4-4. Effect of Curing Method of the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 73°F, Rela­tive Humidity of 25%, and Wind Velocity of 18-20 mph.

18

Page 33: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.9

0.8

0.7

- 0.6 ..__ I.J... 0 (/) .......... (/) 0.5 CD _J -(/) (/)

0 0.4 _J

a::: w ~ ~ 0.3

0.2

0.1

0

~-------NO CURE

-------·--- MMF(I)+WPC

WPC

WSLO

ENVIRONMENT 100°F-30% RH

WIND 18-20 mph

LABORATORY SUMMER 1971

10 20 30 40 50

'riME (HOURS) Fig. 4-5. Effect of Curing Method on the Evaporation of

Water from the Surface of the Concrete Slabs at a Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Velocity of 18-20 mph.

19

Page 34: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.8

0.7

0.6

-r- 0.5 l.J...

0 Cf)

' Cf) ro 0.4 _J -Cf) (f) 0 _J 0.3

0::: w r-<r 3: 0.2

0.1

0

MMF(I)+WPC

WSLO

WPC

WIND 18-20 mph

LABORATORY SUMMER 1971

10 20 30 40 50

Tlt\1E (HOURS) Fig. 4-6. Effect of Curing Method on the Evaporation of Water

from the Surface of the Concrete Slabs at a Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Velocity of 18-20 mph.

20

Page 35: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

seen that the slabs without any curing compound (no cure) exhibited con­

siderably higher water loss than any of those with a curing compound.

Further examination of these six figures shows that no significant benefits

were obtained by adding a monomolecular film prior to the application of

white pigmented curing compound. It should be noted that a single appli­

cation of monomolecular film was used, at the highest rate recommended by

the manufacturer. For every environmental condition, except 73°F - 25%

RH and wind 18-20 mph, the water soluble linseed oil (WSLO) and the white

pigmented curing compound (WPC) retarded the rate of evaporation better

than MMF (1) + WPC. In fact, at least a 15 percent reduction in water

loss was noted with use of WSLO and WPC as opposed to MMF (1) + WPC at

73°F and 8-10 mph (Figure 4-1), and there was a reduction of 30 percent

at 140°F and 8-10 mph (Figure 4-3).

4.3 Laboratory January 1973

Three curing methods were considered in this phase of the study -­

monomolecular film (single application) followed by white pigmented curing

compound (MMF (1) + WPC), white pigmented curing compound (WPC), and

monomolecular film (two applications) followed by white pigmented curing

compound (MMF (2) + WPC) (see Tables 5-l in details). In using this third

curing method, it was thought that perhaps two smaller applications of MMF

would be more effective than one large single application. The wind

conditions were held constant at 8-10 mph. Four curing conditions were

employed: (1) 51°F- 23% RH, (2) 57°F- 50% RH, (3) 100°F- 30% RH and

(4) 140°F- 25% RH. In the 5l°F- 23% RH environmental condition a no-cure

specimen was included.

21

Page 36: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.8 -

0.7

0.6

- 'J.5 !-LL. 0 (/) ........ (/) 0.4 m _J -(/) (/) 0 0.3 _J

a:: w ~ 3

0.2

0.1 -

0 0

ENVIRONMENT 51°F-23% RH

WIND 8-IOmph

LABORATORY JANI973

NO CURE

MMF(I)+WPC

WPC

10 20 30 40 50

TIME (HOURS)

Fig. 4-7. Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 51°F, Relative Humidity of 23%, and Wind Velocity of 8-10 mph.

22

Page 37: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-1-LL 0 (/) ....... (/) m _J -(/) (/)

0 _J

0:: w ~ ~

0.8 -

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0 0

. ENVIRONMENT 57° F- 50°/o RH

WIND 8-IOmph

LABORATORY JAN 1973

MMF(I)+WPC

MMF(2)+WPC

10 20 30 40 50

Tlfv1E(HOURS) Fig .• 4-8. Effect of Curing Method on the Evaporation of Water from

the Surface of the Concrete Slabs at a Curing Temperature of 57°F, Relative Humidity of 50%, and Wind Velocity of 8-10 mph.

23

Page 38: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.7

0.6

-I-0.5

l.L 0 (/) ....... (/) 0.4 (I) ....J -en en 0 0.3 ....J

a:: w t:i ;:

0.2

0.1

0 0

ENVIRONMENT 100° F- 30°/o RH

WIND 8-10 mph

LABORATORY JAN 1973

MMF(I)+WPC

MMF(2)+WPC

WPC

10 20 30 40 50 TIME{HOURS)

Fig. 4-9. Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 100°F, Relative Humidity of 30%. and Wind Velocity of 8-10 mph.

24

Page 39: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.8

0.7

- 0.6 t-1..1.. c en ' en

0.5 CD -' -en (f) 0

0.4 -' a:: w ~ ~ 0.3

0.2

0.1

0

ENVIRONMENT 140° F -25°/o RH

WIND 8-IOmph

LABORATORY JAN 1973

10 20 30 40 50

TIME (HOURS}

Fig. 4-10. Effect of Curing Method on the Evaporation of Water from the Surface of the Concrete Slabs at a Curing Temperature of 140°F, Relative Humidity of 25%, and Wind Velocity of 8-10 mph.

25

Page 40: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Figures 4-7 through 4-10 represent the data obtained from this investi­

gation. In all cases, except 140°F - 25% RH, the white pigmented curing

compound was found to be the most effective evaporation retarder. Applying

MMF in two applications generally improved its effectiveness (except in

51°F- 23% RH). Again there was a significant difference between using

any of the three curing methods and no cure (Figure 4-7). As in the previous

section, it can be stated again that there was no significant benefit

gained by applying monomolecular film before finishing. Applying it in two

applications instead of one, however, did improve its effectiveness.

4.4 Field Study - Van Horn, September 1973

Five curing methods were tested in this phase of the study: MMF (1) +

WPC, MMF (2) + WPC, WPC, WSLO, and no cure. Because this test was conducted

outside in a natural environment, the conditions varied somewhat. The air

temperature ranged from 80° - 95°F during the day and decreased to as low

as 60°F at night. The relative humidity ranged from 10 to 25 percent.

The wind conditions varied from 0 to 10 mph.

Figure 4-11 contains the results of this series of tests. All four

curing compounds greatly reduced the evaporation loss compared to the

no-cure method. The material with two applications of MMF lost more water

than did that with only one application, as was the case in the 51°F-

25% RH condition (Figure 4-7). As the difference between MMF (1) + WPC

and MMF (2) + WPC at 140°F = 25% RH was insignificant (Figure 4-10), it

is hypothesized that single applications of MMF are more effective at low

relative humidities than two smaller applications. Figure 4-11 shows

that WSLO, WPC, and MMF (1) + WPC all proved to be effective cures with

little difference in results between any of the three.

26

Page 41: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-r-LL.

0 (/) ....... (f) CD _J -en en 0 _J

0:: w 1-g :s:

ENVIRONMENT 80° -95°F 10- 25°/o RH

WIND 0- 10 mph

1.4 -FIELD VAN HORN , SEPT. 1973

1.2 - NO CURE

1.0

0.8

0.6

0.4

0 0

MMF(2)+WPC

WSLO

- 72"

4 8 12 16 20

TIME (HOURS) Fig. 4-11. Effect of Curing Method on the Evaporation of Water from

the Surface of the Concrete Slabs at a Curing Temperature of 80-95°F, Relative Humidity of 10-25%, and Wind Velocity of 0-10 mph.

27

Page 42: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-..... lL.. 0 (/) ....... (/) m _j -(/) (/) 0 _j

0:: w ~ 3:

0.8

0.7

140°F-25°/o RH

06

100°F-30% RH

0.5

73°F- 25°/oRH 57°F- 50°/oRH

0.4 100°F -30°/oRH

0.3

0.2 51°F-23°/oRH

WIND 8 -10 mph

CURE MMF(I)+WPC

0 L-----~------~------~------~------~--------0 10 20 30 40 50

TiME (HOURS) Fig. 4-12. Effect of Temperature on the Evaporation of

Water from the Surface of the Concrete Slabs Maintaining Constant Curing Method (MMF(l) + WPC) and Wind Conditions of 8-10 mph.

28

Page 43: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.7

0.6

0

WIND - 8- 10 mph CURE- WPC

10 20 30

TIME (HOURS)

40 50

Fig. 4-13. Effect of Temperature on the Evaporation of Water from the Surface of the Concrete Slabs Maintaining Constant Curing Method (WPC) and Wind Conditions (8-10 mph).

29

Page 44: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

4.5 Comparison of Evaporation Rates

As early evaporation plays an important role in the development of

plastic shrinkage cracks, evaporation rates (lbs/sq ft/hr) were determined

for all conditions investigated (see Figures 5-l through 5-11 in the

Appendix) and are summarized in Table 4-1. Evaporation rates are signifi­

cantly reduced through the application of any curing compound, with the

WPC and the WSLO compounds generally allowing less evaporation than either

the MMF (1) + WPC or MMF (2) + WPC.

As a matter of interest a comparison was made between the results ob­

tained experimentally and evaporation rates predicted by the Portland Cement

Association (PCA) evaporation chart (Figure 2-2). 2 Table 4-2 shows

several comparative rates for various temperatures, humidities, and wind

velocities. Some of these values compared quite well while others did not.

Figures 4-12 and 4-13 indicate the relationships obtained in this study

between temperature and evaporation for the data obtained in this research.

It can be seen that there is a general trend for the evaporation to increase

with increasing temperature. This is in disagreement with the published

PCA chart.

4.6 Construction Time Consideration

Although the application of monomolecular films does not appear to

reduce total evaporation, it does have some advantages. By applying a

MMF cure after placing the concrete, time can be gained before having to

finish the pavement. In this research program the monomolecular film

was sprayed on the surface after placement. Then, as soon as the

water sheen disappeared, the surface finishing was performed and the white

pigmented curing compound (WPC) applied. Disappearance of the water

30

Page 45: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE 4~1. Evaporation Rates

Code Designationa Evaporation Rates (1bs/sq ft/hr)

s1

w2

E3

1 .031

s1

w2

E3

2 .058

s1

w2

E3

4 .044

s1

w2

E3

5 .158

s1

w2

E4

1 .065

s1

w2

E4

2 .085

s1

w2

E4

4 .045

s1

w2

E4

5 .136

s1 w2 E5 1 .099

s1 w2 E5 2 .198

s1

w2

E5

4 .085

s1

w2

E5

5 .206

s1 w3 E3 1 .058

s1 w3 E3 2 .062

s1 w3 E3 4 .029

s1 w3 E3 5 .186

s1 w3 E4 1 .107

s1 w3 E4 2 .111

s1

w3

E4

4 .056

s1

w3

E4

5 .182

s1 w3 E5 1 .031

s1 w3 E5 2 .128

s1 w3 E5 4 .047

s1 w3 E5 5 .235

31

Page 46: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Code Designationa

s2

w2

E1

1

s 2 w2

E1

2

s2

w2

E1

3

s2

w2

E1

5

s2

w2

E2

1

s2

w2

E2

2

s2

w2

E2

3

s2 w2

E4

1

s2

w2

E4

2

s2

w2

E4

3

s2 w2

E5

1

s2

w2

E5

2

s2

w2

E5

3

s3 w4 E6 1

s3 w4 E6 2

s3 w4 E6 3

s3 w4 E6 4

s3 w4 E6 5

TABLE 4-1. (Cont'd.)

Evaporation Rates (lbs/sq ft/hr)

.011

.013

.025

.047

.015

.032

.044

.029

.036

.033

.068

.088

.090

.050

.067

.084

.063

.225

aSee Table 3-1 for explanation of code.

32

Page 47: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE 4-2. Comparison of Evaporation Rates

Relative Temperature Humidity Wirtd Evaporation Rates (lbs/sg ttlhr)

(oF) (%) (mph) Experimental a: PCA .

51 23 10 .047 .23

73 25 0 .047 .04

73 25 10 .158 .22

73 25 20 .186 .38

90 20 10 .225 .20

100 30 0 .037 .03

100 30 10 .136 .14

100 30 20 .182 .24

aVa1ues obtained from specimens with no cure.

b From Figure 2-2 using an average concrete temperature of

80°F.

33

Page 48: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

sheen is the controlling factor before finishing is perfonted. Table 4-3

shows the various delay times under different environmental conditions,

and three cures: (WPC, MMF (1) + WPC, and MMF (2) + WPC. Note that the

application of MMF (1) increases the standard delay from 10 to 100 percent

and the application of MMF (2) increases it a remarkable 20 to 300 percent.

These results indicate monomolecular film could prove to be very valuable

in case of delays during construction.

34

Page 49: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE 4-3. Delay Time Before Applying White Pigmented

Curing Compound

Code Designationa

s2

w2 E1 1

s2 w2 E1

2

s2 w2 E1 3

s2 w2 E2 1

s2 w2 E2 2

s2 w2 E

2 3

s2 w2 E

4 1

s2 w2 E4 2

s2

w2

E4

3

s2 w2 E

5 1

s2

w2

E5

2

s2 w2 E5

3

s3 w4 E6

1

s3 w4 E

6 2

s3

w4

E6

3

Delay Time, Min.

25

40

180

48

135

165

50

55

80

30

35

45

38

53

48

aSee Table 3-1 for explanation of code.

35

Page 50: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

5. APPENDIX

5.1 Discussion of Variables

Curing Method; After placing the concrete slabs, one of the five

curing methods was begun. These five curing methods are described in

Table 5-l. Where curing compounds were used the manufacturers recom-

mendations for application were followed as nearly as practical.

Curing Environment. For the first two study sites the environmental

rooms utilized were located in the McNew Laboratory at Texas A&M University.

The third study site employed natural field conditions at Van Horn,

Texas. The slabs were cured in one of six environments as prescribed in

Table 3-1. The specified conditions (in laboratory tests) were accurately

maintained and monitored during the testing periods.

Wind. In the first two study sites, to simulate outdoor conditions,

the slabs were subjected to produce steady conditions, 0 mph (W1), and wind

velocities of 8-10 mph (W2) and 18-20 mph (W3) in order to simulate out-

door conditions. The wind was generated through the use of a fan run by

an electric motor and it was checked periodically with an anemometer.

This generated wind was tunneled through duct work to the required wind

velocity ~ one mph. In the Van Horn study the existing wind conditions

ranged from 0-10 mph (W4).

Finishing. Finishing was accomplished by first screeding the surface

and then applying two passes of a burlap drag.

Design Mixes. The mixes were designed using the absolute volume method

. h 'fi d f d i . dm' 13 w1t a spec1 e cement actor an a r entra1nment a 1xture. All

batches were designed to produce similar strengths based on a cement factor

36

Page 51: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

Designation

1

2

3

4

5

TABLE 5-l. Curing Methods

Curing Type

White Pigmented Curing Compound-Resin Based (WPC)

Monomolecular Film with White Pigmented Curing Compound (MMF(l) + WPC)

Monomolecular Film with White Pigmented Curing Compound (MMF(2) + WPC)

Water Soluble Linseed Oil (WSLO)

No Cure

37

Description

A white pigmented curing compound was sprayed on the test slabs after finishing and after the water sheen had disappeared from the surface (180 sq ft/gal.)

A monomolecular film was sprayed on the surface of the test slabs in one single application prior to finishing (200 sq ft/gal.). After finishing, as soon as the water sheen had disappeared from the surface, the same white pigmented curing compound as was used in curing method 1 was sprayed on the surface.

Same as curing method 2, except the monomolecular film was sprayed in two applications, 100 sq ft/gal. each.

A water soluble linseed oil was applied to the surface upon com­pletion of the finishing operation (200 sq ft/gal.).

The slab was allowed to cure without any type of curing compound application.

Page 52: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

of 5 sacks of cement per cubic yard of concrete, a coarse aggregate

factor (CAF) of 0.78 with a maximum size of 1 1/2 in., a water-cement

ratio (w/c) of 0.5, an air content of 3 percent (4 to 5 percent at Van

aorn), and a slump of 1 in.± 1/2 in. Due to the presence of free moisture

in the aggregates used, the mixing water had to be altered slightly in

some cases to maintain the desired slump. The time lapse between the

introduction of cement to the mix and the final placement of the concrete

into the forms was held as constant as practicable for all test slabs.

5.2 Laboratory Procedures

The concrete for all batches in the laboratory was mixed in a 6 cu ft

portable rotary-drum mixer. Materials were stored inside the laboratory so

as to maintain a constant batch temperature (approximately 80°F). Prior

to hatching, a small "butter batch" consisting of identical materials as

the batch, was placed and mixed in the mixer. This compensated for the

materials which would normally stick in the mixer. The coarse aggregate and

part of the mixing water containing air entrainment admixture was added

initially. After approximately one minute of mixing, the cement and fine

aggregate were added. The mixing then continued for approximately five

minutes.

After the mixing was completed, the slump test (ASTM Cl43-66), unit

weight (ASTM Cl39-63), and air content (ASTM C231-68) were determined

and recorded. At the completion of these control tests, the concrete was

then taken to the appropriate environmental room and placed in three layers

in the steel forms (Figure 3-1). As soon as the concrete was placed, it

was vibrated and screeded. Next finishing and curing operations began

as given in Table 5-l. After finishing the surface and applying the curing

38

Page 53: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

compounds, the water loss measurements were made in accordance with the

procedure given in section 3-2.

5.3 Field Procedures

The concrete was hatched in a large concrete mixing plant used in the

construction of Interstate Highway 10 near Van Horn, Texas. Concrete for the

evaporation study was taken from the haul trucks and placed in the steel

forms (Figure 3-1), vibrated and screeded. Finishing and appropriate curing

methods (Table 5-l) were applied and the water loss measurements were con­

ducted in the same manner as in the laboratory.

5.4 Tabulated and Plotted Test Results

Table 5-2 contains the summarized results of this phase of research.

Figures 5-l through 5-11 present plots of the evaporation rates during

the initial hours of the curing process •. The data in Table 5-2 were

corrected for the change in weight due to application of the curing compound.

For complete curves see Figures 4-1 through 4-11.

39

Page 54: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE 5-2. Evaporation Rates in Lbs Per Sq Ft

Code Time in Hours Designation a 1/2 1 1 1/2 2 3 4 6 10 21 24 45 50

s1 w1 E3

5 .013 .026 .040 .093 .132 .158 .231 .410 - .515 .541

s1 w2

E3

1 - .053 .053 .079 .112 .158 .185 .238 - .343 .370

s1

w2

E3

2 .066 .119 .125 .158 .211 .244 .284 .330 - .436 .449

s1 w2

E3

4 - .053 .086 .106 .158 .191 . 211 .251 - .356 .396

s1 w2

E3

5 .101 .106 .178 .238 .396 .506 .629 .739 - .843 .869

s1 1-12 E4

1 - .053 .093 .132 .172 .185 .225 .278 - .357 .397

s1 w2 E4

2 .026 .079 .106 .172 .251 .304 .436 .449 - .515 .554

~ s1

w2

E4

4 - .053 .074 .106 .132 .146 .225 .251 - .331 .370 0

s1 w2 E4

5 .013 .079 .150 .220 .366 .458 .604 .617 - .678 .706

s1

w1

E4

5 .020 .040 - - .126 .172 .278 .488 - .594 .628

s1

w2

E5

1 - .092 .145 .224 .304 .356 .383 .475 - .554 .620

s1 w2

E5

2 .040 .106 .198 .356 .528 .554 .660 .739 - .832 .884

s1 w2

E5

4 - .066 .106 .172 .264 .343 .356 .449 -. .528 .581

s1

w2

E5

5 - .167 .304 .453 .629 .700 .726 .779 - .849 ;898

s1 w1

E5

5 .013 .020 .053 .093 .152 .218 .370 .475 - .554 .622

s1

w3

E3

1 - .066 .092 .145 .198 .238 .356 .462 - .607 .660

s1

w3 E3

2 - .026 .079 .119 .172 .211 .304 .383 - .528 .581

s1 w3 E3

4 - - .079 .145 .185 .198 .218 . 277 - .383 .422

Page 55: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE 5-2. (Cont'd.)

Code Time in Hours D · t" a es1gna 1on 1/2 1 1 1/2 2 3 4 6 10 21 24 45 50

s1 w3

E3

5 - .040 .128 .246 .409 .559 .757 .893 - • 977 .988

s1

w3

E4

1 - .079 .132 .185 .290 .343 .436 .502 - .554 .581

s1

w3

E4

2 .106 .158 .238 .304 .396 .449 .541 .607 - .660 .673

s1 w3

E4

4 - .053 .079 .119 .172 .198 .277 .370 - .422 .449

s1

w3

E4

5 .053 .097 .189 .282 .449 .524 .621 .683 - .741 .745

s1

w3

E5

1 - .079 .092 .119 .145 .172 .238 .251 - .330 .409

s1

w3

E5

2 .040 .106 .172 • 277 .370 .449 .541 .554 - .660 .713

s1 w3

E5

4 - - .079 .145 .198 .264 .343 .356 - .449 .541 .j::-

...... s1 w3 E5 5 .040 .145 .308 .436 .528 . 572 .629 .664 - .713 .774

s2 w2 E1 1 - .026 .032 .032 .045 .056 .065 .084 .103 .123 - .156

s2

w2 E1 2 .044 - .063 .063 .081 .088 .100 .118 .137 .156 - .199

s2

w2

E1

3 - .066 . 079 .092 .106 .139 .152 .185 .225 .251 - .298

s2

w2

E1

5 .038 .051 .089 .109 .153 .190 .236 .340 .548 .606 - .682

s2

w2

E2

1 .038 .056 .069 - .075 .088 .119 .160 .201 .207 .270 .283

s2 w2

E2

2 .040 .053 .093 .139 .159 .179 .225 .274 .331 .345. .430 .430

s2 w2 E2 3 .019 .026 .058 - .103 .128 .167 .187 .258 .258 .335 .335

s2 w2 E4

1 .019 .031 .044 .069 .100 .131 .162 .206 .269 - .306 .312

s2 w2

E4

2 .055 .092 .110 .135 .177 .202 .246 .276 .350 - .387 .393

Page 56: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

TABLE 5-2. (Cont'd.)

Code Time in Hours D . . a 1/2 1 1 1/2 2 3 4 6 10 21 24 45 50 es1gnat1on

s2

w2

E4

3 .045 .089 .102 .134 .159 .185 .205 .237 .288 - .334 .346

s2

w2

E5

1 .149 .164 .184 .239 .316 .365 .461 .506 .582 .582 - .683

s2

w2

E5

2 .076 .113 .170 .232 .314 .370 .427 .489 .571 .578 - .661

s2

w2

E5

3 - .126 .164 .226 .296 .365 .448 .486 .561 .561 - .649

s3

w4

E6

1 .114 .186 .192 .216 .255 .302 .356 - .533 .533

s3

w4

E6

2 .066 .159 .159 .186 .269 .335 .422 - .539 .539

s3

w4

E6

3 .110 .186 .198 .225 .323 .410 .560 - .839 .839

s3

w4

E6

4 - .116 .138 .165 .237 .284 .455 - .572 .572 +:'-N s

3 w

4 E

6 5 .198 .290 .437 .650 .916 1.048 1.246 1.251 - -

aSee Table 3-1 for explanation of code.

Page 57: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-~ lL

0 (/)

........ (/)

CD _J -(/)

.j::- (/) w

0 _J

a:: w ~ <l ~

.50

I ENVIRONMENT 73° F- 25 °/o

.40 ~ WIND 8-10 mph LABORATORY SUMMER 1971

m = SLOPE

.30

I _/

I / MMF(I) + WPC m = .058

.20

.I 0 I / -------- """

WPC m= .031

0 ~----~------~----~------~----~------~------0 2 3

TIME (HRS)

Fig. 5-l. Evaporation Rates at the Curing Temperature of 73°F, Relative Humidity of 25%, and Wind Conditions of 8-10 mph.

4

Page 58: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-~ lJ...

0 en ...... en CD ...J -en

+:-- en +:--

0 ...J

0:: w ~ <(

~

.50~----~------~----~------~----~------~----~

.40 r

.30 I

.2o L

.10 ~

0 0

EN VIR 0 N MEN T I 00 o F - 30 °/o R H WIND 8- 10 mph NO CURE LABORATORY SUMMER 1971 /m= .136 m = SLOPE

/ MMF(I) + WPC /m = .085

/ ~ WPC r- m = .065

~WSLO m = .045

2 3

TIME ( HRS)

Fig. 5-2. Evaporation Rates at the Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Condition of 8-10 mph.

4

Page 59: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

~ V1

. 70

I ENVIRONMENT 140° F- 25 °/o RH t .60 r WIND 8- 10 mph LABORATORY SUMMER 1971 m = SLOPE 0 .50

~ I / ~MMF(I}tWPC m = .198 CJ)

m .40 _J -CJ) CJ) .30 0 _J

0::: .20 ~ WSLO w m = .085 ._ <(

3: .I 0

0 ~--~----~--~----~--~----~--~--~ 0 2 3

TIME (HRS)

Fig. 5-3. Evaporation Rates at the Curing Temperature of 140°F, Re­lative Humidity of 25%, and Wind Conditions of 8-10 mph.

4

Page 60: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-t-LL.

0 en ........ en CD _J -

.p-. en 0\ en

0 _J

a:: w t-<{

~

.50

.40

.30

.20

.10

ENVIRON ME NT 73° F- 25°/o RH

WIND 18-20 mph

LABORATORY SUMMER 1971

m = SLOPE

MMF (I) + WPC m = .062

NO CURE m = .186

0 ~--~----~~----~----~----~----~----~--~ 0 2 3

TIME ( HRS)

Fig. 5-4. Evaporation Rates at the Curing Temperature of 73°F, Relative Humidity of 25%, and Wind Conditions of 18-20 mph.

4

Page 61: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-1-lJ..

0 en

' en m _J -en

~ en ..._,

0 _J

a:: w 1-<(

3:

.50 I

ENVIRONMENT 100° F- 30 °/o RH

.40 ~ WIND 18-20 mph LABORATORY SUMMER 1971

/ ~ MMF(I) + WPC m =SLOPE m=.lll .

.30 r /7 ~WPC m = .107

.20

v // WSLO m = .056

.10

0 ~----~------~----~------~----~------~----~ 0 2 3

TIME ( HRS) Fig. 5-5. Evaporation Rates at the Curing Temperature of 100°F, ·Relative Humidity

of 30%, t.Jind Conditions of 18-20 mph.

4

Page 62: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

.60 I

- .50 r 1-LL.

0 en .40 ........ CJ) (I) ...J - .30

~ en 00 en I 0

...J .20

0:: w 1-<(

3: .I 0

0 0

ENVIRON ME NT 140° F - 25°/o RH /--NO CURE WIND 18-20mph m = .235 LABORATORY SUMMER 1971 m =SLOPE / MMF(I) + WPC

~m = .128

/ / WSLO ~m=.047

2 3

TIME (HRS)

Fig. 5-6. Evaporation Rates at the Curing Temperature of 140°F, Relative ~umidity of 25%, and Wind Conditions of 18-20 mph.

4

Page 63: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

· ENVIRONMENT 51" F- 23% RH

.16 - WIND 8-10 mph

LABOR.l'·.'rORY JAN 1973

.14 m=slope

.12

m=0.047

MMF(2)+WPC m=0.025

.02 -

0 .___ ___ ..~ _____ j, ____ ..__ ___ ....L..,_ ___ ._J,_ ___ _

0 I 2 3 4

TIME (HOURS)

Fig. 5-7. Evaporation Rates at the Curing Temperature of 51°F, Relative Humidity of 23%, and Wind Conditions of 8-10 mph.

49

Page 64: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-..... lL 0 (/)

' (/) OJ _J -(/) (/) 0 _J

0:: w ~ 3:

ENVIRONMENT 57° -50°/oRH

.16 WIND 8-IOmph

LABORATORY JAN 1973

MMF(I)+WPC m=0.044

.14 m=slope

.12

MMF(2)+WPC m=0.032

.10

.08

.06 -

.04

.02

0 ~----~------~------~------~------~------0 2

TIME (HOURS) 3 4

Fig. 5-8. Evaporation Rates at the Curing Temperature of 57°F, Relative Humidity of 50%, and Wind Conditions of 8-10 mph.

50

Page 65: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-t-I.&..

0 (/) ........ (/) m ..J -(/) (/)

g a: w ~ 3:

ENVIRONMENT IOOOF-30% RH

.I 6 WIND 8-10 MPH

.14

.12

. 10

.08

.06

.04

.02

0

LABORATORY ~AN 1973

m =SLOPE

MMF(I) +WPC m=0.036

0 2

MMF(2)+ WPC m=0.033

3

Tl ME (HOURS)

4

Fig. 5-9. Evaporation Rates at the Curing Temperature of 100°F, Relative Humidity of 30%, and Wind Con­ditions of 8-10 mph.

51

Page 66: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

0.40 ENVIRONMENT 140°F- 25°/o RH

_0.30 I-LL

0 (/)

.......... (/) CD _J -

0.20 (/) (/)

0 _J

a:: w ~ ~

0.10

WIND 8- 10 mph LABORATORY JAN 1973 m= SLOPE

WPC m= 0.068

MMF (I)+ WPC m= 0.088

MMF (2) +WPC m= 0.090

0.0------~0------~------~------~----~ I 2 3 4

TIME (HOURS) Fig. 5-10. Evaporation Rates at the Curing Temperature of

140°F, Relative Humidity of 25%, and Wind Con­ditions of 8-10 mph.

52

Page 67: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

-I­LL

.8

.6

0 en ........ CJ) CD .4 _J -CJ) CJ) 0 _J

0::: w ~ 3: .2

0

ENVIRONMENT 80°- 95°F

WIND 0 -10 mph

FIELD VAN HORN , SEPT 1973

m =slope

NO CURE m=0.225

MMF(2)+WPC m=0.084

m=0.063

WPC m=·o.050

0

MMF(I)+WPC m=0.067

I 2 3

TIME (HOURS) 4

Fig. 5-11. Evaporation Rates at the Curing Temperature of 80-95°F, Relative Humidity of 10-25%, and Wind Conditions of 0-10 mph.

53

Page 68: Technical ll::1r,nrto; Center Texas T -~:·~r.;Uon Institute, · PDF fileTechnical ll::1r,nrto; Center Texas T 1 Cii\.•i ... In these tests the water soluble linseed oil curi

5.5 References

1. Paine, J. E., "Skid Resistance of Concrete Pavements," Concrete Construction, Vol. 14, No. 10, October 1969.

2. "Curing of Concrete," Concrete Information Bulletin, Portland Cement Association, Chicago, Illinois, 1966, 5 pp.

3. Powers, T. C., "A Discussion of Cement Hydration to the Curing of Concrete," Proceedings, Highway Research Board, Vol. 27, 1947, pp. 178-188.

4. Carrier, R. E., and Cady, P. D., "Evaluating Effectiveness of Concrete Curing Compounds," Journal of Materials, JMLSA, Vol. 5, No. 2, June 1970, pp. 294-302.

5. Newlon, H. H., Jr., "Evaluation of Several Types of Curing and Protective Materials for Concrete," Virginia Highway Research Council, VHRC 70-Rl6, October 1970, 43 pp.

6. Stewart, P. D., and Shaffer, R. K., "Investigation of Concrete Protective Sealants and Curing Compounds," Research Project No. E-66-2, Pennsylvania Department of Highways, April 1967, 47 pp.

7. Scholer, C. H., and Best, C. H., "Concrete Curing and Surface Protection with Linseed Oil," Special Report Number 60, Kansas State University Bulletin, July 1965, 22 pp.

8. Cordon, W. A., and Thorpe, J. D., "Control of Rapid Drying of Fresh Concrete by Evaporation Control," Proceedings, ACI Journal, Vol. 62, No. 8, August 1965, pp. 977-984.

9. Newlon, H. H., Jr., "Random Cracking of Bridge Decks Caused by Plastic Shrinkage," Virginia Highway Research Council, December 1966, 7 pp.

10. Lerch, William, "Plastic Shrinkage," Proceedings, ACI Journal, Vol. 53, No. 2, February 1957, pp. 797-802.

11. Shalon, R., and Ravins, D., "Studies in Concreting in Hot Countries," Proceedings, Symposium on Concrete and Reinforced Concrete in Hot Countries, (Haifa; 1960), RILEM, Paris (published by Israel Institute of Technology, Haifa, 1960), 45 pp.

12. Shalon, R., and Ravins, D., "Plastic Shrinkage," Proceedings, ACI Journal, Vol. 65, No. 4, April 1968, pp. 282-291.

13. Construction Bulletin C-11, Texas Highway Department Construction Division, January 1964, pp. 14-16.

54