Dorset Log Cabin Technical Details For Queries and Help please access our Support Centre: www.gardenbuildingsdirect.co.uk/help PROPRIETARY AND CONFIDENTIALITY All the information contained within this document including all technical data, dimensions, shape/form and branding (inc. Trademarks, logos, etc.) Is the sole property of Kybotech Limited. The reproduction and/or disclosure to any third party of any information contained within this document is strictly prohibited. Breaches of the copyright will be dealt with on the highest level of severity with immediate legal proceedings. © July 2014 - BillyOh.com © gardenbuildings direct .co.uk In association with

Upload: others

Post on 25-Jun-2020

22 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Dorset Log CabinTechnical Details

For Queries and Helpplease access our Support Centre:

www.gardenbuildingsdirect.co.uk/help

PROPRIETARY AND CONFIDENTIALITYAll the information contained within this document including all technical data, dimensions, shape/form and branding (inc. Trademarks, logos, etc.) Is the sole property of Kybotech Limited. The reproduction and/or disclosure to any third party of any information contained within this document is strictly prohibited. Breaches of the copyright will be dealt with on the highest level of severity with immediate legal proceedings.

© July 2014 - BillyOh.com

©

gardenbuildingsdirect .co.uk

In association with

Page 2: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Dorset Log CabinTechnical Details

©

Sizes availableavailable in standard 28mm, premium 35mm and ultimate 44mm cladding

Side elevation: depth 2.5m - Plain Side

Overall Building Depth: Includes Overhangall thicknesses = 2.820m/9’ 3”

Building Wall Depth 28mm = 2.576m/8’ 5” 35mm = 2.590m/8’ 6” 44mm = 2.608m/8’ 7”

Internal Depth all thicknesses = 2.334m/7’ 8”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

Inte

rnal

Eav

es H

eigh

t19

mm

Flo

or =

2.0

33m

/6’ 8

”11

mm

Flo

or =

2.0

41m

/6’ 8

Inte

rnal

Rid

ge H

eigh

t19

mm

Flo

or =

2.3

94m

/7’ 1

0”11

mm

Flo

or =

2.4

02m

/7’1

1”

Page 3: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 5.334m/17’ 6”

Overall Building Widthall thicknesses = 5.652m/18’ 7”

Building Wall Width 28mm = 5.576m/18’ 4” 35mm = 5.590m/18’ 4” 44mm = 5.608m/18’ 5”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W5.5m x D2.5m / W18’1” x D8’2”Dorset: Front elevation

Total Bearer Length = 5.422m/17’ 9”

Bearer Length = 2.711m/8’ 11” Bearer Length = 2.711m/8’ 11”

Minimum Base Width = 5.502m/18’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

2.5

02m

/8’ 3

”O

uter

Bea

rer D

ista

nce

28m

m =

2.3

90m

/7’ 1

0”35

mm

= 2

.404

m/7

’ 11”

44m

m =

2.4

22m

/7’ 1

1”

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er =

0.3

33m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 4: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 4.734m/15’ 6”

Overall Building Widthall thicknesses = 5.052m/16’ 7”

Building Wall Width 28mm = 4.976m/16’ 4” 35mm = 4.990m/16’ 4” 44mm = 5.008m/16’ 5”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W5.0m x D2.5m / W16’5” x D11’6”Dorset: Front elevation

Total Bearer Length = 4.822m/15’ 10”

Bearer Length = 2.411m/7’ 11” Bearer Length = 2.411m/7’ 11”

Minimum Base Width = 4.880m/16’ 0”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

2.5

02m

/8’ 3

Out

er B

eare

r Dis

tanc

e28

mm

= 2

.390

m/7

’ 10”

35m

m =

2.4

04m

/7’ 1

1”44

mm

= 2

.422

m/7

’ 11”

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er =

0.3

33m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 5: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 4.134m/13’ 7”

Overall Building Widthall thicknesses = 4.452m/14’ 7”

Building Wall Width 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’ 6”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W4.5m x D2.5m / W14’9” x D11’6”Dorset: Front elevation

Total Bearer Length = 4.222m/13’ 10”

Bearer Length = 2.111m/6’ 11” Bearer Length = 2.111m/6’ 11”

Minimum Base Width = 4.280m/14’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

2.5

02m

/8’ 3

Out

er B

eare

r Dis

tanc

e28

mm

= 2

.390

m/7

’ 10”

35m

m =

2.4

04m

/7’ 1

1”44

mm

= 2

.422

m/7

’ 11”

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er=

0.3

33m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 6: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 3.834m/12’ 7”

Overall Building Widthall thicknesses = 4.152m/13’ 7”

Building Wall Width 28mm = 4.076m/13’ 4” 35mm = 4.090m/13’ 5” 44mm = 4.108m/13’ 6”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W4.0m x D2.5m / W13’1” x D11’6”Dorset: Front elevation

Total Bearer Length = 3.922m/12’ 10”

Bearer Length = 1.961m/6’ 5”Bearer Length = 1.961m/6’ 5”

Minimum Base Width = 3.980m/13’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

2.5

02m

/8’ 3

”O

uter

Bea

rer D

ista

nce

28m

m =

2.3

90m

/7’ 1

0”35

mm

= 2

.404

m/7

’ 11”

44m

m =

2.4

22m

/7’ 1

1”

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er=

0.3

33m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 7: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

© Dorset Log Cabin

Technical Details

Sizes availableavailable in standard 28mm, premium 35mm and ultimate 44mm cladding types

Side elevation: depth 3.5m - Side WindowOverall Building Depth: Includes Overhang

all thicknesses = 4.042m/13’ 3”

Building Wall Depth 28mm = 3.476m/11’ 5” 35mm = 3.490m/11’ 5” 44mm = 3.508m/11’ 6”

Internal Depth all thicknesses = 3.234m/10’ 7”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

Inte

rnal

Eav

es H

eigh

t19

mm

Flo

or =

2.0

33m

/6’ 8

”11

mm

Flo

or =

2.0

41m

/6’ 8

Inte

rnal

Rid

ge H

eigh

t19

mm

Flo

or =

2.3

94m

/7’ 1

0”11

mm

Flo

or =

2.4

02m

/7’1

1”

Page 8: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 5.334m/17’ 6”

Overall Building Widthall thicknesses = 5.652m/18’ 7”

Building Wall Width 28mm = 5.576m/18’ 4” 35mm = 5.590m/18’ 4” 44mm = 5.608m/18’5”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W5.5m x D3.5m / W18’1” x D11’6”Dorset: Front elevation

Total Bearer Length = 5.422m/17’ 9”

Bearer Length = 2.711m/8’ 11” Bearer Length = 2.711m/8 11”

Minimum Base Width = 5.502m/18’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

3.4

02m

/11’

2”

Out

er B

eare

r Dis

tanc

e28

mm

= 3

.290

m/1

0’ 1

0”35

mm

= 3

.304

m/1

0’ 1

0”44

mm

= 3

.322

m/1

0’11

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er0.

325m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 9: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 4.734m/15’ 6”

Overall Building Widthall thicknesses = 5.052m/16’ 7”

Building Wall Width 28mm = 4.976m/16’ 4” 35mm = 4.990m/16’ 4” 44mm = 5.008m/16’5”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W5.0m x D3.5m / W16’5” x D11’6”Dorset: Front elevation

Total Bearer Length = 4.822m/15’ 10”

Bearer Length = 2.411m/7’ 11” Bearer Length = 2.411m/7’ 11”

Minimum Base Width = 4.880m/16’ 0”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

3.4

02m

/11’

2”O

uter

Bea

rer D

ista

nce

28m

m =

3.2

90m

/10’

10”

35m

m =

3.3

04m

/10’

10”

44m

m =

3.3

22m

/10’

11”

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er=

0.3

25m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 10: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 4.134m/13’ 7”

Overall Building Widthall thicknesses = 4.452m/14’ 7”

Building Wall Width 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’6”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W4.5m x D3.5m / W14’9” x D11’6”Dorset: Front elevation

Total Bearer Length = 4.222m/13’ 10”

Bearer Length = 2.111m/6’ 11” Bearer Length = 2.111m/6’ 11”

Minimum Base Width = 4.302m/14’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

3.4

02m

/11’

2”

Out

er B

eare

r Dis

tanc

e28

mm

= 3

.290

m/1

0’ 1

0”35

mm

= 3

.304

m/1

0’ 1

0”44

mm

= 3

.322

m/1

0’11

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er=

0.3

25m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 11: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 3.834m/12’ 7”

Overall Building Widthall thicknesses = 4.152m/13’ 7”

Building Wall Width 28mm = 4.076m/13’ 4” 35mm = 4.090m/13’ 5” 44mm = 4.108m/13’6”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W4.0m x D3.5m / W13’1” x D11’6”Dorset: Front elevation

Total Bearer Length = 3.922m/12’ 10”

Bearer Length = 1.961m/6’ 5” Bearer Length = 1.961m/6’ 5”

Minimum Base Width = 3.980m/13’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

3.4

02m

/11’

2”

Out

er B

eare

r Dis

tanc

e28

mm

= 3

.290

m/1

0’ 1

0”35

mm

= 3

.304

m/1

0’ 1

0”44

mm

= 3

.322

m/1

0’ 1

1”

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er=

0.3

25m

/1’ 1

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT38PT

38PT38PT

38PT

38PT

38PT

38PT

75PT75PT

75PT75PT

75PT75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 12: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

© Dorset Log Cabin

Technical Details

Sizes availableavailable in standard 28mm, premium 35mm and ultimate 44mm cladding types

Side elevation: depth 4.5m - Side WindowOverall Building Depth: Includes Overhang

all thicknesses = 4.659m/15’ 3”

Building Wall Depth 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’ 6”

Internal Depth all thicknesses = 4.134m/13’ 7”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

Inte

rnal

Eav

es H

eigh

t19

mm

Flo

or =

2.0

33m

/6’ 8

”11

mm

Flo

or =

2.0

41m

/6’ 8

Inte

rnal

Rid

ge H

eigh

t19

mm

Flo

or =

2.3

94m

/7’ 1

0”11

mm

Flo

or =

2.4

02m

/7’1

1”

Page 13: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 5.334m/17’ 6”

Overall Building Widthall thicknesses = 5.652m/18’ 7”

Building Wall Width 28mm = 5.576m/18’ 4” 35mm = 5.590m/18’ 4” 44mm = 5.608m/18’5”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W5.5m x D4.5m / W18’1” x D14’9”Dorset: Front elevation

Total Bearer Length = 5.422m/17’ 9”

Bearer Length = 2.711m/8’ 11” Bearer Length = 2.711m/8 11”

Minimum Base Width = 5.502m/18’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

4.3

02m

/14’

1”

Out

er B

eare

r Dis

tanc

e28

mm

= 4

.190

m/1

3’ 9

”35

mm

= 4

.204

m/1

3’ 1

0”44

mm

= 4

.222

m/1

3’10

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er0.

296m

/1’ 0

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 14: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 4.734m/15’ 6”

Overall Building Widthall thicknesses = 5.052m/16’ 7”

Building Wall Width 28mm = 4.976m/16’ 4” 35mm = 4.990m/16’ 4” 44mm = 5.008m/16’5”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W5.0m x D4.5m / W18’1” x D14’9”Dorset: Front elevation

Total Bearer Length = 4.822m/15’ 10”

Bearer Length = 2.411m/7’ 11” Bearer Length = 2.411m/7’ 11”

Minimum Base Width = 4.902m/16’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

4.3

02m

/14’

1”

Out

er B

eare

r Dis

tanc

e28

mm

= 4

.190

m/1

3’ 9

”35

mm

= 4

.204

m/1

3’ 1

0”44

mm

= 4

.222

m/1

3’10

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er0.

296m

/1’ 0

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 15: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 4.134m/13’ 7”

Overall Building Widthall thicknesses = 4.452m/14’ 7”

Building Wall Width 28mm = 4.376m/14’ 4” 35mm = 4.390m/14’ 5” 44mm = 4.408m/14’6”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W4.5m x D4.5m / W14’9” x D14’9”Dorset: Front elevation

Total Bearer Length = 4.222m/13’ 10”

Bearer Length = 2.111m/6’ 11” Bearer Length = 2.111m/6’ 11”

Minimum Base Width = 4.302m/14’ 1”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

4.3

02m

/14’

1”

Out

er B

eare

r Dis

tanc

e28

mm

= 4

.190

m/1

3’ 9

”35

mm

= 4

.204

m/1

3’ 1

0”44

mm

= 4

.222

m/1

3’10

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er0.

296m

/1’ 0

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)

Page 16: Technical Details - BillyOh.com › global › guides › dorset-technical... · Technical Details Sizes available available in standard 28mm, premium 35mm and ultimate 44mm cladding

Doo

r Hei

ght

all t

hick

ness

es =

1.8

76m

/6’ 2

Internal Width all thicknesses = 3.834m/12’ 7”

Overall Building Widthall thicknesses = 4.152m/13’ 7”

Building Wall Width 28mm = 4.076m/13’ 4” 35mm = 4.090m/13’ 5” 44mm = 4.108m/13’6”

Exte

rnal

Rid

ge H

eigh

tal

l thi

ckne

sses

= 2

.470

m/8

’ 1”

Win

dow

Op

enin

g H

eigh

tal

l thi

ckne

sses

= 1

.217

m/4

’ 0”

Exte

rnal

Eav

es H

eigh

tal

l thi

ckne

sses

= 2

.090

m/6

’ 10”

W4.0m x D4.5m / W13’1” x D14’9”Dorset: Front elevation

Total Bearer Length = 3.922m/12’ 10”

Bearer Length = 1.961m/6’ 5” Bearer Length = 1.961m/6’ 5”

Minimum Base Width = 4.002m/13’ 2”

Min

imum

Bas

e D

epth

all t

hick

ness

es =

4.3

02m

/14’

1”

Out

er B

eare

r Dis

tanc

e28

mm

= 4

.190

m/1

3’ 9

”35

mm

= 4

.204

m/1

3’ 1

0”44

mm

= 4

.222

m/1

3’10

Bear

er S

pac

ing

from

cen

tre

of e

ach

bear

er0.

296m

/1’ 0

Front of Building

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

38PT

75PT

75PT

75PT

Please note: your base must be perfectly level and drainage is required to allow water to run off the surface. There must also be at least 2m clearance on each side to allow annual treatment to be applied.

Base Size and Bearers Layout (Pressure Treated)