    SPEED AND PRECISION

    TECCON IS A STRUCTURAL SYSTEM BASED ON GALVANIZED LIGHT-STEEL FRAMING, FOR THE CONSTRUCTIONOF SINGLE- AND MULTIFAMILY DWELLINGS, SCHOOLS AND OTHER SERVICE BUILDINGS (RESIDENCES HOSPITALS, ETC.).

  • 8/14/2019 Teccon Evolution Brochure

    2/10

    TECCON

    http://www.itec.es/NouDite.e/vigents.aspx

    TECCON is a new construction system,using a metal structure made up o unitsthat are designed and actory-manu actu-red in advance.

    TECCON is a structural system based onlight gauge steel raming or single- amilydwellings, multi amily dwellings, schoolsand other service buildings (residences,hospitals, etc.).

    TECCON is a system that uses kits madeup a combination o exterior wall, interiorwall and oor/ceiling units that are pre abri-cated as separate sections. They arrive onsite preassembled, and both the European

    Technical Codes and applicable Europeanlegislation are strictly observed.

    TECCON System is patented and isunique in the market because o its per or-mance in terms o being sel -supporting,the extent to which it is pre abricated, itsspeed o onsite assembly and its high qua-lity standards.

    TECCON System is an industrial pro-duct, which may be sold in any internatio-nal market.

    TECCON is not just a product: it o erscontinuous, high-level technical supportand advice to the sectors pro essionals.

    TECCON

    R&D&I

    researchdevelopmenttechnological innovation

    TECCON OFFERS INNOVATIVE SOLUTIONS THANKS TO ITS CONTINUOUS RESEARCH AND DEVELOPMENT PROCESS

    MANUFACTURER&D&I

    http://www.itec.es/NouDite.e/vigents.aspx

  • 8/14/2019 Teccon Evolution Brochure

    3/10

    ADVANTAGESFEATURES TECCON System is characterized by a series o eatures that are o great value both fnancially and in terms o the number o uses theycan be put to or all those involved in improving housing.It meets the requirements o the new Spanish Technical Code.It has CE con ormity marking, guaranteeing the quality o workmanship.

    FOR THE ARCHITECT

    O ers the most advanced technology, o the best quality and at thebest price.Ensures that the Final Design has the maximum construction detailpossible.Guarantees higher quality construction work (precision and per orman-ce).

    TECCON Systems per ormance is certifed using o fcial tests at theEOTA (European Commission).Ensures certifcation by the Technical Monitoring O fces, withouttechnical reservations.Guarantees the processing o the ten-year insurance policy.

    The time saved when implementing the design allows:- Higher turnover o the capital invested.

    - Streamlining o the commercial management o the project. The use o cutting-edge technology improves the promoters imageand makes them stand out rom the crowd in a sector in which there islittle to di erentiate one company rom another.

    FOR THE PROMOTOR

    ASSEMBLY TRANSPORT

    FOR THE BUILDING CONTRACTORReduces the time required to raise the buildings structure to one thirdo that required in conventional construction.Simplifes site management ( ewer components, personnel, etc.).Onsite assembly errors are impossible.Easily handled components. No need or a fxed crane on site. Redu-ces the risk o onsite accidents.

    There are teams o authorized ftters available.Constructed using pre abricated parts and completely dry methods.

    Technical O fce at your service. TECCON takes care o measurements and budget. TECCON takes care o System Report and Calculations. TECCON System is per ormance-tested in o fcial laboratories (ther-mal, fre, and sound insulation, as well as impact absorption).Possibility o drawing up initial designs using the systems compo-nents, optimizing the project rom its conception.

    TECCON System does not limit the Architects creativity. The exibilityo the system allows it to be adapted to the demands o the design.

    Allows the Architect to o er something di erent rom the norm, espe-cially or public tenders.

    PREFABRICATEDFewer teams o onsite workers, reduced costs, reduced tolerances, e ecti-ve quality control and maintenance, onsite work quickly completed.

    HIGH-PERFORMANCE Altogether, TECCON Systems per ormance ensures compliance with themain international technical building codes.

    SUSTAINABLE All materials used are recycled. Constructed using completely dry me-thods. No waste is produced on site. Once it has fnished being used, thesystem can be dismantled and the majority o its components reused.

    SAFE Thanks both to the quality control required when producing vertical andhorizontal sections and to TECCON Systems onsite assembly, there is

    zero risk o errors (an important actor in designs using large numbers o pre abricated elements and low-skilled workers).

    FAST AND EASY TECCON System arrives on site pre abricated. Quickly assembled. Facili-tates the work o the rest o the pro essionals on site. The technical projectmanagers monitoring o assembly time is more accurate.

    FINANCIALIt leads, on average, to a 15% reduction in the budget or structures and

    oundations and a 40% reduction in construction time, compared withconventional systems. It also leads to other advantages, variable depen-ding on the promoter-building contractor, in the areas o logistics andfnances (greatest benefts in capital turnover).

    FLEXIBLE Any exterior fnish is possible (TECCON System is only the interior

    ramework).

    VERIFIED TECCON System has been awarded the internationally recognized ETA(European Technical Approval).

  • 8/14/2019 Teccon Evolution Brochure

    4/10

    USES

    SELF-SUPPORTING TECCON SYSTEMground oor + 4 oors

    TECCON SYSTEM AS A LIGHTWEIGHTBUILDING ENVELOPE FOR EXTERIOR WALLSunlimited number o oors

    SELF-SUPPORTING TECCON SYSTEM+ TRADITIONAL STRUCTUREground oor + 8 oors

    *Single- amily dwellings*Multi amily dwellings*O fce buildings*Hotels and Resorts*Schools*Building renovation

    SELF-SUPPORTING

    MIXED

    NON-SUPPORTING

    FOR TECCON SYSTEM

  • 8/14/2019 Teccon Evolution Brochure

    5/10

    COMPONENTS THAT MAKE UP TECCON SYSTEM TECCON SYSTEM

    CEILINGS

    VERTICAL SECTIONS

    HORIZONTAL SECTIONS

    LIGHTWEIGHT EXTERIOR WALLS

  • 8/14/2019 Teccon Evolution Brochure

    6/10

    6

    1

    1

    9

    10

    2

    35

    8

    13

    2

    3

    4

    6

    7

    8

    9

    1011

    13

    12 7

    2

    8

    VERICAL SECTIONS TECCON SYSTEM

    1

    Framework o 105mm cold-rolled galvanized steel beamsFramework o 250mm cold-rolled galvanized steel beamsFixings: sel -tapping bolt or joining metal componentsLayer o neopreneCold-rolled galvanized steel beam. Lightweight-panel envelope100mm mineral wool sheet in light gauge steel rameworkInternal sheet o standard 13mm laminated plasterboardElectrical installations (with 36mm cladding coming rom the suspended ceiling)Standard 15mm laminated plasterboard10mm OSB/3Impermeable HDPE sheet. Water vapor-resistant40mm airway in ventilated exterior wallExterior lining

    123456789

    10111213

  • 8/14/2019 Teccon Evolution Brochure

    7/10

    3

    1

    2

    4

    7

    8

    9

    1

    1

    1

    3

    5

    6

    7

    98

    10

    6

    11

    1213

    14

    8

    9

    Framework o 250mm cold-rolled galvanized-steel beamsLow-density fberglass sheet in ramework o lightweight oor/ceiling units0.6mm ribbed steel sheet19mm OSB/3 in lightweight oor/ceiling unitsInsulating and shock-absorbing sheet5mm screed

    Floating parquetElectrical installationsRF suspended ceiling. 20mm fbrous silicate sheet (lightweight oor) / 13mm laminated plasterboard (composite oor)Lining16cm C25/30 composite concreteRebar meshRebars (optional)

    Trapezoidal metal sheet with 8cm-high sections

    123456

    789

    1011121314

    HORIZONTAL SECTIONS TECCON SYSTEM

    LIGHTWEIGHTFLOOR/CEILING UNIT 2spans up to 9m

    LIGHTWEIGHTFLOOR/CEILING UNIT 1spans up to 9m

    2

    COMPOSITEFLOOR/CEILING UNITSspans up to 5m

  • 8/14/2019 Teccon Evolution Brochure

    8/10

    3

    4

    LIGHTWEIGHT EXTERIOR WALLS TECCON SYSTEM

    ROOVES TECCON SYSTEMSLOPINGPREFABRICATED ROOF

    FLATPREFABRICATED ROOF

    Modular rameworkMineral-wool thermal insulation in light gauge steel ramework10mm OSB/3Impermeable HDPE sheet. Water vapor-resistantExterior lining with airway

    DETAILS VERTICAL SECTION AS LIGHTWEIGHT EXTERIOR WALL ENVELOPE

    12345

    1 2 3 4 5

  • 8/14/2019 Teccon Evolution Brochure

    9/10

    CHARACTERISTICSMECHANICAL RESISTANCE AND STABILITY

    THERMAL, FIRE AND SOUND INSULATION

    IMPACT RESISTANCE

    Type o modularwall- ramework (2)

    Characteristic resistance o modular wall- ra-meworks under axial compression (Nc,Rk)

    Design resistance o modular wall- rameworksunder axial compression (Nc,Rd) (1)

    Blind wall 1200

    Blind wall 600

    Door 1200

    kN76,73

    102,66

    69,65

    kN/m63,64

    171,10

    58,04

    kN61,38

    82,13

    55,72

    kN/m51,15

    136,88

    46,43

    Characteristic and design resistance o modular wall- rameworks under axial compression.

    10mm OSB/3Modular wall- ramework 1200 with 100mm interior thermal insulationStandard 15mm laminated plasterboard

    10mm OSB/3Modular wall- ramework 1200 with 100mm interior thermal insulation2 sheets o standard laminated plasterboard

    10mm OSB/3Modular wall- ramework 1200 with 100mm interior thermal insulationStandard 12.5mm laminated plasterboard36mm airwayStandard 12.5mm laminated plasterboard

    10mm OSB/3Modular wall- ramework 1200 with 100mm interior thermal insulationStandard 12.5mm laminated plasterboard30mm thermal insulation inside a 36mm airwayStandard 12.5mm laminated plasterboard

    Standard 15mm laminated plasterboardModular wall- ramework 1200 with 100mm interior thermal insulationStandard 15mm laminated plasterboard

    2 sheets o standard 12.5mm laminated plasterboardModular wall- ramework 1200 with 100mm interior thermal insulation2 sheets o standard 12.5mm laminated plasterboard

    Standard 15mm laminated plasterboardStandard 12.5mm laminated plasterboardModular wall- ramework 1200 with 100mm interior thermal insulationStandard 12.5mm laminated plasterboardStandard 15mm laminated plasterboard

    Standard 15mm laminated plasterboard36mm airwayStandard 12.5mm laminated plasterboardModular wall- ramework 1200 with 100mm interior thermal insulationStandard 12.5mm laminated plasterboard36mm airwayStandard 15mm laminated plasterboard

    Standard 15mm laminated plasterboard30mm thermal insulation inside a 36mm airwayStandard 12.5mm laminated plasterboardModular wall- ramework 1200 with 100mm interior thermal insulationStandard 12.5mm laminated plasterboard30mm thermal insulation inside a 36mm airwayStandard 15mm laminated plasterboard

    Impermeable sheet15mm OSB/3Roo trusses80mm thermal insulationStandard 9.5mm laminated plasterboard

    Floor covering50 mm screed

    Trapezoidal light gauge metal sheet with 80mm trapezoids160mm concrete rein orced with rebar meshStandard 15mm laminated plasterboard on the underside

    REI 45(side exposed to fre)

    REI 60(side exposed to fre)

    REI 60(side exposed to fre)

    REI 60(side exposed to fre)

    REI 45(side exposed to fre)

    REI 60(side exposed to fre)

    REI 60(side exposed to fre)

    REI 60(side exposed to fre)

    REI 60(side exposed to fre)

    REI 60 (3) REI 120 (3)

    Confguration REI Rw (dB)

    EXTERIOR WALLS45(-3;-11)

    > 45 (-3;-11)

    > 45 (-3;-11)

    > 45 (-3;-11)

    47 (-2;-8)

    52 (2)

    55 (-1;-6)

    55 (-1;-6)

    59 (-3;-10)

    54 (-4;-12)

    Rw (dB)Lw (dB)

    STRUCTURAL INTERIOR WALLS

    SLOPING, TRUSSED ROOF

    A.

    B.

    C.

    Ueq [W/(m 2 K)]

    0,62

    0,57

    0,49

    0,49

    0,37

    0,52 (2)

    0,59

    0,47

    0,25

    0,37

    TECCON SYSTEM

    Interior walls (2940mm tall):Standard 15mm laminated plasterboardModular wall- ramework with 100mm interior thermal insulationStandard 15mm laminated plasterboard

    IV b500 Nm

    IV b500 Nm

    Resistance to structural damage causedby the impact o a so t object(50kg sack)

    Resistance to structural damage causedby the impact o a so t object(50kg sack)

    (1) Average values or sections o wall without windows(2) Untested values

    (1)

    Confguration tested

    SUSTAINABILITYD. TECCON is a new construction system based on recycled materials. No waste is produced on site.Once it has fnished being used, the system can be dismantled and the majority o its components reused.

    COMPOSITE FLOOR/CEILING UNITS

    (3) By calculation, in accordance with the Spanish Technical Code(4) Values tested on site

    Notes:

    Notes: (1) Taking into account the Spanish National Parameters or Determination (NPD partial coe fcient M = 1.25; SYS= 1.00)(2) There is no structural di erence between the types o modular ramework used in the interior and exterior walls.

    = 52 (4)= 47 (3)

  • 8/14/2019 Teccon Evolution Brochure

    10/10

    TECCON EVOLUTION S.L.www.tecconevolution.com

    Carrer de la Rassa, 38Polg. Indus. Santa Ana III08251 SantpedorEspaa

    Cel. Tel.Fax.