team dea cpd presentation
DESCRIPTION
Training Presentation to TEAM Domestic Energy AssesorsTRANSCRIPT
TEAM CPD Training Day
15th November 2011
Thursday 13 April 2023
Presentation title
Introduction
Northgate CPD Training
• Neal Gascoine - EA/EPC Quality Assurance Controller
Presentation title
Agenda
Tuesday 15th November• Introduction & Agenda• Green Deal• Audit Failure Issues• Modelling Extensions in RdSAP 9.90• Modelling Multiple Heating Systems in RdSAP
9.90• EA Ethics & Professionalism Questions
Presentation title
Green Deal
Green Deal• April 2012• NOS still to be agreed• Customer Facing issues to be resolved• Mandatory common CPD requirements• Due to go live October 2012
Presentation title
CPD Training
Audit Failure Issues• Most common audit failures over the
last three months are as follows;• Incorrectly classifying extensions.• Incorrect floor construction data.• Incorrect use of Mechanical Ventilation• Incorrect roof construction classification.• Incorrect DHW heating data.• Incorrect heating control data.
Presentation title
Audit Failure Issues
Incorrectly classifying extensions.• Integral Garages.
• Not dividing property when present.• Consistent error.• Small SAP variance from error.• Error easy to identify during audit.• Effects EPC property descriptions on the
EPC.
Presentation title
Audit Failure Issues
Incorrect floor construction data.• Integral Garages.
• Floor type – Above unheated space.• Dwelling above shops/commercial premises.
• Floor type – Above intermittently/partially heated space.
• Dwelling above open space to external elements.• Floor type – To external air.
• Effects EPC property descriptions on the EPC.
Presentation title
Audit Failure Issues
Incorrect use of Mechanical Ventilation.• When to use?
• RdSAP requires this selection if Whole House system present only
• RdSAP assumes individual extract fans are already present.
• Generally used for all properties where extract fans are found.
• Effects SAP rating and heating costs
Presentation title
Audit Failure Issues
Incorrect roof construction classification.• Roof Rooms.
• Most common audit failure.• DEA’s failing to follow conventions.• Conventions supplied to help a DEA.
• Effects SAP rating, recommendations and property descriptions on the EPC.
Presentation title
Audit Failure Issues
Room in a roof
Presentation title
Audit Failure Issues
Room in a roof
Roof room with dormer windows
Roof room with large dormer windows (chalet style)
Basic roof room Roof room with vaulted ceiling
Presentation title
Audit Failure Issues
Room in a roof
Less than1.8 m
Less than1.8 m
Roof room
At least 1.8 m
At least1.8 m
Separate storey, not roof room
Presentation title
Audit Failure Issues
Incorrect DHW heating data.• Immersion heater being specified incorrectly
• Main heating system present.• Several pipework runs to HWC.• Back-up Immersion installed.
• Effects SAP rating, recommendations and property descriptions on the EPC.• Look for Pumps adjacent to HWC.• Look for Three port valves to HWC• Above indicate heated from main boiler
not immersion.
Presentation title
Audit Failure Issues
Incorrect DHW heating data.
Presentation title
Audit Failure Issues
Incorrect Heating control data.• Boiler Energy managers.
• Control system very rare.• Weather compensation systems.• Generally selected when no Room Stat
present.• DEA does not understand what a Bypass
is!• Effects SAP rating, recommendations and
property descriptions on the EPC.
Presentation title
CPD Training
Modelling extensions in RdSAP 9.90.• DEA’s not using the multiple extension
options.• Incorrect floor descriptions being used.• Incorrect roof descriptions being used.• DEA’s still not dividing extensions due to
thermally different portions of the property.
• Effects SAP rating, recommendations and property descriptions on the EPC.
Presentation title
Modelling Extensions
What is an Extension in RdSAP?• In RdSAP an extension is classed as part of the
dwelling which is thermally different or has different characteristics from the main property e.g. Roof, floors or walls. The extensions must be heated and occupied for it to be recorded.
• If an extension is the same age, construction and insulation properties as the main house it must be included as part of the main dwelling.
Presentation title
Modelling Extensionss
To follow are various forms of extension that can be found;• Integral unheated garage where the main dwelling
extends over the unheated garage but is part of the original construction of the property.
Presentation title
Modelling Extensions
• Unheated garage adjacent to the main dwelling where a new extension has been created above the unheated garage.
Presentation title
Modelling Extensions
• Original construction single storey extension to the side of the main property (utility room?) that has now been extended above.
Presentation title
Modelling Extensions
• Integral garage conversion into a habitable room where the main dwelling extends over the originally unheated garage but is part of the original construction of the property.
Presentation title
Modelling Extensions
• 2 storey extension adjacent and above the existing main dwelling.
Presentation title
Modelling Extensions
• Dwelling with two separate roof room constructions above the main dwelling.
Presentation title
CPD Training
Modelling multiple heating systems in RdSAP 9.90.• DEA’s not using the multiple heating system
options correctly.• Incorrectly selecting Main Heating 2 for a
Secondary heating source.• Incorrectly selecting Main Heating 2 to
heat “living area” careful of % split.• Applying a percentage to a Main heating 2
system although only supplies heat for DHW.
• Effects SAP rating, recommendations and property descriptions on the EPC.
Presentation title
Modelling Multiple Heating Systems
Primary Heating 2 main heating systems• It is possible to have 2 main heating systems
modelled in RdSAP• RdSAP conventions explain how to model this type
of scenario correctly • Some simple options for two main heating systems
are to follow
Presentation title
Modelling Multiple Heating Systems
Primary Heating 2 main heating systems
Presentation title
Modelling Multiple Heating Systems
Primary Heating 2 main heating systems
Presentation title
Modelling Multiple Heating Systems
Primary Heating 2 main heating systems
Presentation title
Modelling Multiple Heating Systems
Primary Heating 2 main heating systems
Presentation title
CPD Training
EA Ethics & Professionalism Questions.• A variety of questions design to assess DEA
knowledge covering all areas of EPC production.
Presentation title
CPD Training
Question and Answer Session.