te -10k -md,te -10p -md...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90...

8
0 10 20 30 40 50 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 0 20 40 60 80 100 120 140 160 180 200 M E T E R S L.P.M. H E A D I N F E E T G.P.M. TE-10K-MD, TE-10P-MD 3PH 60HZ TRIM CURVES 7.250 FULL SIZE IMPELLER 6.625 6.250 5.750 5.250 5.250 7.250 --- IMPELLER COVER REMOVED SPECIFIC GRAVITY CHART SP.GR. TRIM IMPELLER TO 1.0-1.1-----7.250 DIA. FULL SIZE 1.0-1.2-----6.625 DIA. 1.0-1.4-----6.250 DIA. 1.0-1.7-----5.750 DIA. 1.0-2.0-----5.250 DIA.

Upload: others

Post on 20-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

30

40

50

0 100 200 300 400 500 600 700

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

0 20 40 60 80 100 120 140 160 180 200

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MD3PH 60HZ TRIM CURVES

7.250 FULL SIZE IMPELLER

6.625

6.250

5.750

5.250

5.250

7.250

--- IMPELLER COVER REMOVED

SPECIFIC GRAVITY CHARTSP.GR. TRIM IMPELLER TO1.0-1.1-----7.250 DIA. FULL SIZE1.0-1.2-----6.625 DIA.1.0-1.4-----6.250 DIA.1.0-1.7-----5.750 DIA.1.0-2.0-----5.250 DIA.

Page 2: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

30

40

50

0 100 200 300 400 500 600 700

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

0 20 40 60 80 100 120 140 160 180 200

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MDFULL SIZE IMPELLER 7.250 DIA.

3PH 60HZ

H.P.

H.P.

10

8

FULL SIZE IMPELLER 7.250 DIA.

7

N.P.S.H.R.FEET

13

16

14

17

15

N.P.S.H.R.

11

9

Page 3: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

30

40

0 100 200 300 400 500 600 700

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

0 20 40 60 80 100 120 140 160 180 200

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MDTRIM IMPELLER 6.625 DIA.

3PH 60HZ

H.P.

H.P.

9

7

TRIM IMPELLER 6.625 DIA.

6

N.P.S.H.R.FEET

13

16

14

17

15

N.P.S.H.R.

10

8

Page 4: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

30

40

0 100 200 300 400 500 600 700

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

0 20 40 60 80 100 120 140 160 180 200

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MDTRIM IMPELLER 6.250 DIA.

3PH 60HZ

H.P.

H.P.

8

6

TRIM IMPELLER 6.250 DIA.

5

N.P.S.H.R.FEET

12

15

13

16

14

N.P.S.H.R.

9

7

Page 5: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

30

0 100 200 300 400 500 600 700

0

10

20

30

40

50

60

70

80

90

100

110

120

0 20 40 60 80 100 120 140 160 180

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MDTRIM IMPELLER 5.750 DIA.

3PH 60HZ

H.P.

H.P7

5

TRIM IMPELLER 5.750 DIA.

4

N.P.S.H.R.FEET

12

15

13

16

14

N.P.S.H.R.

8

6

Page 6: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

30

0 100 200 300 400 500 600

0

10

20

30

40

50

60

70

80

90

100

0 20 40 60 80 100 120 140 160 180

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MDTRIM IMPELLER 5.250 DIA.

3PH 60HZ

H.P.

H.P.

6

4

TRIM IMPELLER 5.250 DIA.

3

N.P.S.H.R.FEET

12

15

13

14

N.P.S.H.R.

5

Page 7: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

30

0 100 200 300 400 500 600 700

0

10

20

30

40

50

60

70

80

90

100

110

120

0 20 40 60 80 100 120 140 160 180

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MDFULL SIZE IMPELLER 7.250 DIA.

IMPELLER COVER REMOVED3PH 60HZ

H.P.

H.P.6

4

FULL SIZE IMPELLER 7.250 DIA.IMPELLER COVER REMOVED

3

N.P.S.H.R.FEET

12

15

13

16

14

N.P.S.H.R.

7

5

Page 8: TE -10K -MD,TE -10P -MD...0 10 20 30 40 0 100 200 300 400 500 600 700 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 m e t e r s l.p.m

0

10

20

0 100 200 300 400 500

0

10

20

30

40

50

60

70

0 20 40 60 80 100 120 140

METERS

L.P.M.

HEAD

IN

FEET

G.P.M.

TE-10K-MD, TE-10P-MDTRIM IMPELLER 5.250 DIA.

IMPELLER COVER REMOVED3PH 60HZ

H.P.

H.P.

5

3

TRIM IMPELLER 5.250 DIA.IMPELLER COVER REMOVED

2

N.P.S.H.R.FEET

12

15

13

14

N.P.S.H.R.

4