Page 1: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

FIRE PUMPS

UL 448

FGPS/FGPE 00 07-12 EN

FGPS / FGPE

Page 2: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

General Information

UL (Underwriters Laboratories Inc.) is a global independent safety science company offering expertise across five key strategicbusinesses: Product Safety, Environment, Life & Health, University and Verification Services. Since the year UL founded in 1894,nearly 70,000 manufacturers in 100 countries have produced 20.000 different types of totally 20 billion UL Marked products.

UL engineers scientifically investigate and test thousands of types of products, materials, constructions and systems to evaluatethe electrical, fire and injury risks; the burglary or fire resistance; or the ability to detect, control or limit fires.

UL has developed 1,200 Standards for Safety, which serve as the bedrock of compliance in over 200 industries.

There is an “Online Certifications Directory” in UL’s website and all the products listed by UL can be found here.

The requirements of this standard cover design and test features of centrifugal fire pumps intended for use in water-supplysystems for fire-protection service.

The pumps covered by these requirements are intended for installation and use in accordance with the Standard for theInstallation of Stationary Pumps for Fire Protection, NFPA 20.

Who UL is and What UL does:

UL Safety Standard: UL 448

Design Features according to UL:

Only the specified capacities in the below table are allowed for rated capacity. For capacities higher than 5000 GPM, 500 GPMincrements are allowed.

All interior bolt or screw that are exposed to pumped liquid shall be of rolled bronze or corrosion resistant material

The pump shall be provided with automatic air-release valve, circulation relief valve and pressure gauges

Bearings shall have an L-10 rating of not less than 5000 hours at maximum load.

The pumps shall be provided with at least four packing rings plus a lantern ring. The lantern ring may be permitted to replaceone ring of packing.

Impellers, wear rings, shafts, lantern rings, glands shall be made of corrosion resistant material.

Following material specifications are applied to FIRE GUARD UL fire pumps:

Casing

Impeller

Shaft

Shaft sleeve

Nodular cast iron

Cast bronze

Stainless steel

Stainless steel

GGG 40 (GJS-400-15)

G-CuSn 10

X20 Cr 13

X5 Cr Ni Mo 17-12-2

0.7040

2.1050.01

1.4021

1.4401

A 536 Gr. 60-40-18

B 584 C 90700

A 276 Type 420

A 276 Type 316

Part List Definition DIN 17007 EN-DIN ASTM

GPM

25

50

100

150

200

250

300

m³/h

5.68

11.3

22.7

34.0

45.4

56.8

68.1

GPM

400

450

500

750

1000

1250

1500

m³/h

90.8

102.2

113.5

170

227

284

341

GPM

2000

2500

3000

3500

4000

4500

5000

m³/h

454

568

681

795

909

1022

1136

Page 3: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

200 GPMn = 3000 min -1

FGPE 50-250DN 80/50

300 GPMn = 3000 min -1

FGPE 50-250DN 80/50

250 GPMn = 3000 min -1

FGPE 50-250DN 80/50

300 GPMn = 3000 min -1

FGPE 65-250DN 100/65

GPM

160

140

120

100

0,0 100,0 200,0 300,0 400,0 500,0 600,0

ø264

ø245

ø210

80

60

40

20

0

120

100

80

60

40

20

0

%50 %55 %50 %65 %70

60

50

40

30

20

10

0

50

40

30

20

10

0

ø264

ø245

ø210

3024181260

1086420

ø264

1501257550250 100Q - (Capacity) - (m³/h)

GPM

160

140

120

100

Q - (Capacity) - (m³/h)

1086420

3024181260

1501257550250 100

ø264

50

40

30

20

10

0

60

50

40

30

20

10

0

ø264

ø245

ø210

0,0 100,0 200,0 300,0 400,0 500,0 600,0120

100

80

60

40

20

0

80

60

40

20

0

ø264

ø245

ø210

%50 %55 %50 %65%70

%74,0

%73,0

%71,0

GPM

Q - (Capacity) - (m³/h)50

40

30

20

10

0

60

50

40

30

20

10

0

ø264

ø245

ø210

0

1086420

3024181260

ø264

0 100 200 300 400 500 600120

100

80

60

40

20

0

160

140

120

100

80

60

40

20

0

%50 %55 %50 %65ø264

ø245

ø210

%70

Q - (Capacity) - (m³/h)

160

140

120

100

1086420

2001257550250 100 175150

3024181260

ø264

60

50

40

20

10

0

30

80

50403020100

7060ø264

ø245

ø220

0 100 200 300 400 500 600 700 800120

100

80

60

40

20

0

80

60

40

20

0

ø264

ø245

ø220

%55 %60 %65 %70%75

GPM

150125755025 100

Performance Curves

Page 4: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

450 GPMn = 3000 min -1

FGPE 65-250DN 100/65

450 GPMn = 3000 min -1

FGPE 80-250DN 125/80 500 GPM

n = 3000 min -1FGPE 80-250

DN 125/80

400 GPMn = 3000 min -1

FGPE 65-250DN 100/65

Q - (Capacity) - (m³/h)

3024181260

200500 100 15025 75 125 175

1086420

ø264

80

50403020100

607050

40

30

20

10

0

60

ø264

ø245

ø220

160

140

120

100

80

60

40

20

0

120

100

80

60

40

20

0

ø264

ø245

ø220

%60 %65 %70%75

%77,0

%76,0

%74,0

0 100GPM

200 300 400 500 600 700 800

160

140

120

100

ø264ø245

ø210

50403020100

607080

100

80

60

40

20

0

GPM

Q - (Capacity) - (m³/h)

120

100

80

60

40

20

0

80

60

40

20

0

0 200 600 800 1000 1200400

ø264

ø245

ø210

%60 %65 %70 %75

864

20

24181260

200500 100 150 250 300

ø264

Q - (Capacity) - (m³/h)

GPM

5040302010

0

100

80

60

40

20

0

607080

ø264ø245

ø210

86420

24181260

200500 100 150 250 300

ø264

120

100

80

60

40

20

0

160

140

120

100

80

60

40

20

0

0 200 600 800 1000 1200400

%60 %65 %70 %75ø264

ø245

ø210

80

50403020100

607050

40

30

20

10

0

60

GPM

Q - (Capacity) - (m³/h)

160

140

120

100

80

60

40

20

0

120

100

80

60

40

20

0

0 100 200 300 400 500 600 700 800

ø264

ø245

ø220

%60 %65 %70 %75%77,0

%76,0

%74,0

3024181260

1086420

200500 100

ø264

150

ø264

ø245

ø220

Performance Curves

Page 5: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

1000 GPMn = 3000 min -1

FGPS 100-250DN 150/100

GPM0 200 400 600 800 1000 1200 1400 1600

140

120

100

80

60

40

20

0 0

20

40

60

80

100

120

140

160

180

6

4

2

00 50 100 150 200 250 300 350 400

Q - (Capacity) - (m³/h)

0

12

48

16

020406080100120140160

0

40

80

120

160

200

750 GPMn = 3000 min -1

FGPS 100-250DN 150/100

GPM

1250 GPMn = 3000 min -1

FGPS 125-315DN 200/125

GPM

1500 GPMn = 3000 min -1

FGPS 125-315DN 200/125

GPM

ø220

ø294 %55 %60 %65 %70

ø260

ø294

ø294

ø260

ø220

ø220

ø294 %55 %60 %65 %70

ø260

ø294

ø260

ø220

ø294

0 200 400 600 800 1000 1200 1400 1600140

120

100

80

60

40

20

06

4

2

0

020406080100120140160

0 50 100 150 200 250 300 350 400Q - (Capacity) - (m³/h)

12

48

16

0

20

40

60

80

100

120

140

160

180

0

40

80

120

160

200

0

0

10

2468

3024181260

0 100 200 300 400 500 600 700

ø320

0

50

100

150

200

250

300360

300

240

180

120

60

0

ø320

ø290

ø250

100

120

140

160

20

0

40

60

80

0 400 800 1200 1600 2000 2400 2800

220

200

180

160

140

120

100

80

60

40

20

0

ø250

ø290

ø320

3000

3000

3000

%75%70%60 %65%55

Q - (Capacity) - (m³/h)

0

10

2468

3024181260

0 100 200 300 400 500 600 700

ø320

0

50

100

150

200

250

300360

300

240

180

120

60

0

ø320

ø290

ø250

220

200

180

160

140

120

100

100

120

140

160

20

0

40

60

80

0 400 800 1200 1600 2000 2400 2800

80

60

40

20

0

ø250

ø290

ø320%75%70%60 %65%55

Q - (Capacity) - (m³/h)

Performance Curves

Page 6: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

Selection Table

Page 7: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

Selection Table

Page 8: FGPS / FGPE1000 GPM n = 3000 min-1 FGPS 100-250 DN 150/100 GPM 0 200 400 600 800 1000 1200 1400 1600 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 16 0 180 6 4 2 0 0 50 100 150

Sectional Drawings

Right reserved to change without notice.No responsibility is accepted because of printing errors.

2nd Floor, 145-157 St John streetLondon EC1V 4PYUnited Kingsdom

Pbx: + 44 (0) 845 075 1042Fax: + 44 (0) 845 299 1039

Fireguard Safety Equipment Co Ltd.

www.fireguard-uk.com / e-mail: [email protected]

001003010020021030031034035042044050060065070088200210211212230301320321322323400405410411420

Volute CasingStuffing BoxSupport FootWear Ring (back)Wear Ring (front)Bearing HousingBearing Bracket LanternBearing Cover (outboard)Bearing Cover (inboard)Stuffing Box GlandLantern RingImpellerShaftImpeller NutShaft Protecting SleeveThrowerBall BearingImpeller KeyCoupling KeySleeve KeyDrain PlugStud+Nut+WasherHex. Head BoltHex. Head BoltHex. Head BoltHex. Head BoltStuffing Box PackingSet ScrewGasketGasketO-Ring

PartNumber

Part Name

FPGE 50-250 , FPGE 65-250 , FPGE 80-250

FPGS 100-250 , FPGS 125-315

003003A013014020030034

034A035

035A042044050060070071088200210211212220231270271300320350360390391392400411420421430500501

PartNumber Part Name

Stuffing Box (right side)Stuffing Box (left side)Volute Casing (top)Volute Casing (bottom)Wear RingBearing HousingBearing Cover (inboard)Bearing Cover (inboard)Bearing Cover (outboard)Bearing Cover (outboard)Stuffing Box GlandLantern RingImpellerShaftShaft Protecting SleeveSleeve (spacer)ThrowerBall BearingImpeller KeyCoupling KeyKeyOil SealDrain PlugNippleGrease NippleStudHex.Head BoltAllen ScrewNutLocknut (non drive end)Locknut (drive end)Lock WasherStuffing Box PackingGasketO-RingO-RingPinValveFlushing Pipe

042 044 400 070 020 210 050 270 071 034 271 035

060

035A

500 003 300 421 030 200

430

420 350 390

211

391 392

014

088

212

220360 320

034A

003A

013

411

231

501

044 060

050

210

200420

211

320

400 042

021

230

030

010

322

065

031

035

323

321

301

034

405

001

088003

020

411

212

410

070