Page 1: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

TCU Model 2080Operation and Maintenance

BOM Version 851-110195-120

Revision BAugust 2001

Page 2: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

PUBLISHED BYPublications DepartmentLam Research Corporation4650 Cushing ParkwayFremont, California 94538-6470E-mail: [email protected]

Copyright ©2001 by Lam Research Corporation. Printed in the United States of America. All Rights Reserved.

The information conveyed in this document has been carefully checked and is believed to be reliable at the time of printing. However, Lam Research Corporation makes no warranty regarding the information set forth in this document and assumes no responsibility for any errors or inaccuracies contained herein. Lam Research Corporation is not obligated to update or correct any information contained in this document. Lam Research Corporation reserves the right to change products or specifications at any time without notice.

Modifications to Lam products may affect their safe operation and may also affect compliance with various laws and regulations governing their operation. To reduce the likelihood of interference, RF transmitters (cellular telephones, CB radios, cordless telephones) should not be used in the vicinity of Lam products.

Lam recommends that customers check with local fire departments within their jurisdictions to ensure all marking requirements are satisfied.

No part of this document may be reproduced in any form for any purpose without the prior written permission of Lam Research Corporation.

2300, 384T, 4520XLE, Advanced Capability Rainbow, Alliance, AutoEtch, Classic, CoolPORT, Continuum, DSS, DSS-150, DSS-200, Deep SubMicron and DSP, EndPoint Plus, Envision, Envoy, Exelan, the Lam logo, Oxide, Rainbow, Synergy, Synergy Integra, Teres, Transformer Coupled Plasma, TCP, and Versys are trademarks of Lam Research Corporation. All other trademarks or registered trademarks are the property of their respective holders. Mention of third-party products or services is for informational purposes only, and does not

Revision A May 2000—First Printing (ECN released)

Revision B August 2001—Second Printing

Part Number: 406-240155-120

Page 3: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Safety Preface

The safety guidelines for the equipment in this manual do not purport to address all the safety issues of the equipment. It is the responsibility of the user to establish appropriate safety, ergonomic, and health practices and determine the applicability of regulatory limitations prior to use. Potential safety hazards are identified in this manual through the use of words Danger, Warning, and Caution, the specific hazard type, and pictorial alert icons.

Hazard Levels

Danger: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This is limited to the most extreme situations.

Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution: Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It may also alert users against unsafe practices.

Notice: Indicates a statement of company policy (that is, a safety policy or protection of property).

Pictorial Alert Icons

ELECTRICAL

HOT SURFACE BIOHAZARD ENTANGLEMENT PINCH POINT

MASS

CUT/SEVER FALL

SLIP EXPLOSION

__ A __ V

FUSE GENERAL ALERT

ELECTRICAL

POISON

CORROSION RADIO FREQUENCY FLAMMABLE FIRE

UV

ULTRAVIOLET RADIATION

RADIATION

LASERCRUSHING

RESPIRATORY HAND EYEEAR FOOTHEAD

Page 4: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Manual Change Request

Use the Engineering Change Request (ECR) process to request a change or correction to an existing ECN-released manual. The ECR Online Submittal form is found on the Manufacturing Engineering Services (MES) web site on the Lam internal web site.

The path to the MES site is:

http://fre_web01.dhcp.lamrc.com/websitelive/index.htm

For manuals not covered by the ECN process, please submit manual changes to the Publications Manager, Lam Publications Department, Lam Research Corporation, 4650 Cushing Parkway, Fremont, CA 94538-6470 or fax to (510) 572-1056. Please include the part number and revision of the manual in your submission.

Send e-mail to [email protected].

Manual Change Request, Lam Research Corporation

Page 5: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

TCU Model 2080Operation and Maintenance

BOM Version 851-110195-120

Cleanroom Version

Revision BAugust 2001

Page 6: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

PUBLISHED BYPublications DepartmentLam Research Corporation4650 Cushing ParkwayFremont, California 94538-6470E-mail: [email protected]

Copyright ©2001 by Lam Research Corporation. Printed in the United States of America. All Rights Reserved.

The information conveyed in this document has been carefully checked and is believed to be reliable at the time of printing. However, Lam Research Corporation makes no warranty regarding the information set forth in this document and assumes no responsibility for any errors or inaccuracies contained herein. Lam Research Corporation is not obligated to update or correct any information contained in this document. Lam Research Corporation reserves the right to change products or specifications at any time without notice.

Modifications to Lam products may affect their safe operation and may also affect compliance with various laws and regulations governing their operation. To reduce the likelihood of interference, RF transmitters (cellular telephones, CB radios, cordless telephones) should not be used in the vicinity of Lam products.

Lam recommends that customers check with local fire departments within their jurisdictions to ensure all marking requirements are satisfied.

No part of this document may be reproduced in any form for any purpose without the prior written permission of Lam Research Corporation.

2300, 384T, 4520XLE, Advanced Capability Rainbow, Alliance, AutoEtch, Classic, CoolPORT, Continuum, DSS, DSS-150, DSS-200, Deep SubMicron and DSP, EndPoint Plus, Envision, Envoy, Exelan, the Lam logo, Oxide, Rainbow, Synergy, Synergy Integra, Teres, Transformer Coupled Plasma, TCP, and Versys are trademarks of Lam Research Corporation. All other trademarks or registered trademarks are the property of their respective holders. Mention of third-party products or services is for informational purposes only, and does not

Revision A May 2000—First Printing (ECN released)

Revision B August 2001—Second Printing

Part Number: 409-240155-120

Page 7: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Safety Preface

The safety guidelines for the equipment in this manual do not purport to address all the safety issues of the equipment. It is the responsibility of the user to establish appropriate safety, ergonomic, and health practices and determine the applicability of regulatory limitations prior to use. Potential safety hazards are identified in this manual through the use of words Danger, Warning, and Caution, the specific hazard type, and pictorial alert icons.

Hazard Levels

Danger: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This is limited to the most extreme situations.

Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution: Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It may also alert users against unsafe practices.

Notice: Indicates a statement of company policy (that is, a safety policy or protection of property).

Pictorial Alert Icons

ELECTRICAL

HOT SURFACE BIOHAZARD ENTANGLEMENT PINCH POINT

MASS

CUT/SEVER FALL

SLIP EXPLOSION

__ A __ V

FUSE GENERAL ALERT

ELECTRICAL

POISON

CORROSION RADIO FREQUENCY FLAMMABLE FIRE

UV

ULTRAVIOLET RADIATION

RADIATION

LASERCRUSHING

RESPIRATORY HAND EYEEAR FOOTHEAD

Page 8: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Manual Change Request

Use the Engineering Change Request (ECR) process to request a change or correction to an existing ECN-released manual. The ECR Online Submittal form is found on the Manufacturing Engineering Services (MES) web site on the Lam internal web site.

The path to the MES site is:

http://fre_web01.dhcp.lamrc.com/websitelive/index.htm

For manuals not covered by the ECN process, please submit manual changes to the Publications Manager, Lam Publications Department, Lam Research Corporation, 4650 Cushing Parkway, Fremont, CA 94538-6470 or fax to (510) 572-1056. Please include the part number and revision of the manual in your submission.

Send e-mail to [email protected].

Manual Change Request, Lam Research Corporation

Page 9: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Contents

Chapter 1 Overview 1

Introduction 1

Changes Since Last Revision 1

How to Contact Us 2

Ordering Manuals 2

Safety 3

Training 3

Environmental Regulations 3

Point-of-Use Abatement 3

Hazardous Waste 4

Secondary Containment 4

HAPS Regulations Management 4

Emergency Off 5

Energized Electrical Work Types 5

Lockout/Tagout 5

Ergonomics 6

Protective Gear 6

Enclosure Interlocks 7

TCU Description 7

Refrigerant Characteristics 7

Refrigerant Flow 8

Coolant Flow 10

Specifications 12

Front Control Panel 13

Front Panel Controls 14

Front Panel Indicators and Displays 15

Rear Panel 17

i

Page 10: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

EMO, Interlocks, and Safety Circuits 19

Emergency Off 19

Interlocks 19

Subsystem Safety Circuits 20

Chapter 2 Installing the TCU 23

Facility Requirements 23

Preparation 24

Chapter 3 Start-Up 31

Chapter 4 Maintenance 39

Troubleshooting Precautions 39

Safety 55

Equipment Required 55

Chapter 5 Calibration 63

Materials 69

Chapter 6 Troubleshooting 77

Schematics 77

Basic Troubleshooting Using the Controller PCB 81

Basic Troubleshooting 81

Status Indicators 82

Appendix A Reference Documentation 95

Index 159

ii TCU Model 2080 Operation and Maintenance (Revision B)

Page 11: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Figures

1–1 Functional Block Diagram of Primary Refrigeration System 9

1–2 Refrigeration Assembly-Right/Rear View 11

1–3 Front Control Panel 14

1–4 Rear Panel, Electronic Enclosure 17

1–5 Schematic-Subsystem Safety Circuit 21

1–6 Schematic-TCU EMO/Interlock Circuit 21

2–1 Rear Panel Installation Connectors and Controls 26

2–2 Center of Gravity-Top View 27

2–3 TCU Facility/Electrical Installation for Lam Standalone 29

2–4 TCU Facility/Electrical Installation -Multi-chamber System/OEM 30

3.1–1 Status/Alarm Indicators and Reset Buttons 35

3.1–2 Hi/Low Temperature Controls and Meter 36

3.1–3 Fail Indicator 37

4.2–1 Status Indicator Reset Buttons 44

4.2–2 Circuit Breakers and Reservoir Fill Ports 45

4.3–1 Electronic Enclosure 49

4.4–1 Gauge Set Connection Points-Refrigerant Charging 53

4.5–1 Front Control Panel 56

4.6–1 Coolant Polishing Cartridges 59

4.6–2 Front Control Panel 60

4.6–3 TCU Rear Panel 60

5.1–1 TCU Controller PCB 68

5.3–1 TCU Resistivity PCB 74

6–1 Interconnect Diagram-210-110197-001 78

6–2 Electronic Enclosure Schematic-210-110198-001 Sheet 1 79

6–3 Electronic Enclosure Schematic-210-110198-001 Sheet 2 80

iii

Page 12: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Figures

iv TCU Model 2080 Operation and Maintenance (Revision B)

Page 13: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Tables

1–1 Coolant and Facility Water Flow 12

1–2 General Specifications 12

1–3 Coolant and Facility Water Interface Hardware Requirements 13

1–4 Interface Connector 72J1 18

1–5 EMO Connector 72J2 18

6–1 Status Indicators 82

6–2 Troubleshooting Guide 83

A–1 Reference Drawings 95

v

Page 14: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Tables

vi TCU Model 2080 Operation and Maintenance (Revision B)

Page 15: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

1Overview

Introduction

The dual channel temperature control unit (TCU Model 2080) is a compact, mobile, liquid heating/cooling system capable of operating over a wide temperature range. The TCU provides temperature control for both the upper and lower electrodes on Lam systems. It features a closed−loop design with no back pressure and features continuous deionization of the heating/cooling liquid (coolant). Reliable service for long periods is assured through the use of hermetically sealed refrigeration compressors and heat exchangers.

The TCU’s upper and lower channels each contain three separate cooling circuits. The first is the primary or main circuit. This circuit runs continuously to remove heat from the coolant reservoir. It is also used to introduce heat into the coolant (in addition to the electrical heater) when required.

The secondary and tertiary circuits energize as the coolant temperature increases, extending the life of the polishing cartridges and preventing the loss of coolant.

Changes Since Last Revision

Revision B contains the following changes:

• Updates Appendix A, "Reference Documentation," to reflect revised drawings.

• Updates front and back title pages.

• Updates screen captures of the front and back control panels of the system.

1

Page 16: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

How to Contact UsOverview

How to Contact Us

We welcome all suggestions to improve this manual. To contact the Lam Publications Department, you can send us an e-mail, fax or regular mail.

Our address is:

E-mail us at: [email protected]

Fax us at: (510) 572-1056

Web site: You can view our manuals on the Lam internal web at:

• http://lamweb.lamrc.com/prodknow/Tech_Pubs_Main.html

Acrobat PDF versions of our manuals can be found on the internal Lam network neighborhood at

\\Fre_filer02\40119\Product Manuals

Ordering Manuals

Manuals can be ordered in standard paper, cleanroom paper and on CD-ROM. You can find a list of all orderable manuals and ordering instructions by going to the Technical Publications web site on the Lam internal web and selecting Catalog of Manuals and CD-ROMs.

Publications DepartmentLam Research Corporation 4650 Cushing ParkwayFremont, CA 94538-6470 U.S.A.

2

TCU Model 2080 Operation and Maintenance (Revision B)
Page 17: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SafetyOverview

Safety

Training

All operating personnel must have the appropriate safety training pertaining to the hazards of the system.

Environmental Regulations

Environmental regulations and requirements vary by the geographic location or governmental jurisdiction in which the product is installed. Various local, regional, and national standards either exist, or are emerging, for the environmental performance of semiconductor process equipment.

Existing environmental requirements, as they pertain to process equipment, include the following categories: air emissions—hazardous air pollutants (HAPs), perflurocarbons (PFCs), volatile organic compounds (VOCs),—water effluent, and solid or liquid hazardous wastes. In addition, performance requirements developed by the semiconductor industry are emerging in the areas of water and energy use efficiency. Lam participates in these discussions and tracks all important developments, some of which will be included in future facility manuals as industry or company standards are developed.

Point-of-Use Abatement

Point-of-Use (POU) emission abatement systems are designed for treating air emissions from the outlet of a specific semiconductor process to remove compounds of interest before they enter the facility's main exhaust ductwork. This distinction separates POU systems from facility-level abatement systems that treat the collected exhausts of an entire facility, or large portion thereof. A typical POU system may serve from one to four similar process systems.

Several types of POU systems currently exist in the marketplace for specific classes of effluents such as HAPS (wet-scrub with chemical, wet-scrub without chemical, oxidation, and so forth), but specific equipment is typically neither provided by, nor recommended by, system suppliers as

TCU Model 2080 Operation and Maintenance (Revision B) 3

Page 18: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SafetyOverview

standard peripheral equipment. As development of such equipment continues to evolve, this may change. Currently Lam is engaged in several research and development efforts for such equipment.

The SEMATECH Transfer Document Point-of-Use Control Systems for Semiconductor Process Emissions provides guidance in the identification and selection of POU systems for particular process applications. In all cases where such equipment is used with Lam products, it is essential that the end-user investigate and comply with any environmental regulations which may be particular to the jurisdiction where the equipment is used.

Hazardous Waste

Various maintenance procedures generate waste products such as lint-free wipes soaked in isopropyl alcohol (IPA), distilled (DI) water, excess grease, and so forth. The amount of solid waste generation is roughly equivalent to the disposable solid waste generated during a preventive maintenance task in addition to the discard replacement materials from the preventive maintenance task.

Treat all waste as toxic. If disposal is required, please observe the proper Occupational and Safety Health Administration (OSHA)-approved and facility-approved disposal practices.

Secondary Containment

The TCU system has secondary containment to prevent hazardous material from accidently leaking into the environment. The secondary containment has sensors to detect leaks and notify the operator.

HAPS Regulations Management

At this printing Lam is underway with test methodologies concerning some HAPS emissions data for the TCU system.

4 TCU Model 2080 Operation and Maintenance (Revision B)

Page 19: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SafetyOverview

Emergency Off

All Lam systems include an emergency off (EMO) system that enables an operator or service technician to quickly disconnect power to the unit. Large, red buttons are located around the system, readily accessible in an emergency. Pushing any one of these buttons shuts off main alternate current (AC) and radio frequency (RF) power and closes all gas valves.

Note After pushing an EMO button, power to the turbo pump or to the Envision™ interface may be provided for a limited time by a battery backup system or from another source.

Energized Electrical Work Types

The Safety Guidelines for Semiconductor Manufacturing Equipment (SEMI S2−93) defines five types of system electrical states. The five types are as follows:

The applicable electrical work types are indicated in the safety information section at the beginning of each procedure.

Lockout/Tagout

Lam recommends that you carefully perform the following lockout/tagout procedures before servicing the unit. Only authorized technicians should perform these tasks.

Type 1 Equipment is fully de−energized (electrically cold).

Type 2 Equipment is energized. Live circuits are covered or insulated. Work is performed at a remote location to preclude accidental shock.

Type 3 Equipment is energized. Live circuits are exposed and accidental contact is possible. Potential exposures are less than 30 volts alternate current (VAC) route mean square (RMS), 42.2 VAC peak, 240 volt-amperes, and 20 joules.

Type 4 Equipment is energized. Live circuits are exposed and accidental contact is possible. Voltage potentials are greater than 30 VAC RMS, 42.2 VAC peak, 240 volt−amperes, and 20 joules, or RF is present.

Type 5 Equipment is energized and measurements and adjustment require physical entry into the equipment, or equipment configuration will not allow the use of clamp−on probes.

TCU Model 2080 Operation and Maintenance (Revision B) 5

Page 20: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SafetyOverview

Shutdown

To shutdown the system,

1 Before servicing, inform all affected personnel that you will shut down the unit for servicing and that you will lock out all energy sources.

2 Shut down the unit using normal shutdown procedures.

3 Lockout and tagout as necessary.

A lockout is a method of keeping equipment from being energized and endangering workers. Lockouts use the following methods:

• A disconnect switch, circuit breaker, valve, or other energy-isolating mechanism is put in the safe or off position.

• A device is placed over the energy-isolating mechanism to hold it in the safe position.

For a tagout, place the energy-isolating mechanism in the safe position, and attach a written warning.

Ergonomics

Use proper lifting and handling when working on the system. Improper ergonomic handling may result in injury. Lam recommends using a sturdy stool or step ladder when performing all service and troubleshooting tasks on the TCU 2080. These tasks may require access to areas that are difficult to reach, especially for the shorter service technician.

Protective Gear

Wear protective, cleanroom−approved clothing, gloves, safety glasses and approved respiratory protection whenever appropriate.

6 TCU Model 2080 Operation and Maintenance (Revision B)

Page 21: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

TCU DescriptionOverview

Enclosure Interlocks

The TCU enclosure covers are equipped with interlocks that disconnect AC power to the system if activated. These interlocks are all in series in the 24 VAC interlock circuit.

TCU Description

The TCU possesses two independent heating/cooling loops. Each loop consists primarily of a coolant reservoir, circulating pump, heat transfer system, various flow and temperature safety interlocks, and controls to maintain coolant conditions. The operational coolant temperature range of the TCU extends from −20 to +80 degrees Celsius for the lower channel and −15 to +80 degrees Celsius for the upper channel. Both channels maintain a temperature stability of ±1 degree Celsius in an idle condition (no dynamic loads attached).

Three major modules are contained within the system: the control electronics module and two refrigeration modules. The control electronics module provides the circuitry required to operate the TCU and controls the safety interlocks. The refrigeration modules contain heater assemblies, water pumps, deionizing cartridges, and complete refrigeration systems. The lower refrigeration module can provide up to 1000 watts—3415 British thermal units per hour (BTU/hour)—of heat removal at an operating temperature of −20 degrees Celsius. The upper module is capable of providing 750 watts (2561 BTU/hour) of heat removal at an operating temperature of −15 degrees Celsius. The heating capacity for both channels is 1600 watts (5464 BTU/hour).

Refrigerant Characteristics

Contact the following company to obtain a Material Safety Data Sheet (MSDS) for information on refrigerant 404A:

National Refrigerants, Inc.661 Kenyon AvenueRosenhayn, NJ 08352Phone: 1-800-262-0012

TCU Model 2080 Operation and Maintenance (Revision B) 7

Page 22: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

TCU DescriptionOverview

Refrigerant Flow

The TCU is a conventional evaporative refrigeration design that uses hydrofluorocarbons refrigerant R−404A. The refrigerant is cycled through the system and is repeatedly compressed, condensed, and evaporated.

Figure 1–1 is a functional block diagram that illustrates the primary cooling circuit for one of the two channels in the TCU (see Figure 1–2). The refrigerant exits the compressor (K−101), which operates continuously at a steady rate, as a high pressure, hot gas. This hot gas enters a condenser (HE−102) where the gaseous refrigerant is cooled and condensed to a liquid state. This cooler liquid exits the condenser and is filtered by an activated carbon filter (F−103), then passes through a sight glass (LG−105). The refrigerant is then metered through a thermostatic expansion (TX) valve (TEV−105) that controls the flow of refrigerant to the evaporator heat exchanger.

The refrigerant exits the TX valve and boils in the evaporator heat exchanger. As it boils off (evaporates) to a gaseous state, the refrigerant absorbs heat from the system’s coolant. It then leaves the evaporator heat exchanger. The TX valve monitors the temperature and pressure of the refrigerant before entry to the suction accumulator (SA−101). The suction accumulator ensures that no liquid is sent to the compressor by diverting and storing any liquid until it can be vaporized.

The refrigerant, as a cool low pressure gas, roughly 30 pounds per square inch (psi), enters the compressor through a crankcase pressure regulator (PCV−101) and a three way service valve (HV−101). A solenoid−operated hot gas bypass valve (SV107) is located between the compressor (K−101) and the condenser (HE−102). This valve opens in the heating mode and closes while the channel is cooling. It effectively bypasses the condenser while allowing the compressor to continue to operate.

8 TCU Model 2080 Operation and Maintenance (Revision B)

Page 23: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

TCU DescriptionOverview

Figure 1–1. Functional Block Diagram of Primary Refrigeration System

FacilityWater

3-way valveHV-101

CompressorK-101

CondenserHE-102

Crankcase pressureregulatorPCV101

Hot gasbypass valve

SV-107

Carbon filter/dryerF-103

ImmersionheaterHE-110

RefrigerantLoop

Thermostaticexpansion valve

TEV-105

Sightglass

LG-105

SuctionAccumulator

SA-101 Evaporator heatexchanger

CoolantLoop Reservoir

T-110

FE-101Flow sensor

DI polishingcartridges

F-109

Heatexchanger

HE-103Pressure relief

valvePCV-110

TemperaturesensorTE-110

PumpP-101

Water valvePCV-102

Tool

~~

~~

TU01P001Functional Block Diagram��������

TCU Model 2080 Operation and Maintenance (Revision B) 9

Page 24: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

TCU DescriptionOverview

Coolant Flow

A 50/50 mixture (by volume) of deionized (DI) water and ethylene glycol is used as the coolant for the system. The coolant is drawn from a five gallon reservoir (T−110) into a positive displacement pump (P−101). If the coolant pressure exceeds 75 psi, the pressure relief valve (PCV−110) opens to divert coolant back to the reservoir.

Before the coolant exits the TCU, a temperature sensor (TE−110) measures the coolant temperature and sends the temperature data to the control board. This ensures that the actual coolant temperature is measured rather than the reservoir temperature.

The coolant pumped from the TCU to the system circulates through the electrode sealplates of the system reaction chamber and returns to the reservoir through a one gallon per minute (gpm) threshold flow switch (FE−110).

A small portion of the coolant is bypassed from the system and fed through a heat exchanger (HE−103) to DI polishing cartridges (F−109). The heat exchanger is cooled by the secondary refrigerant circuit and is activated when the reservoir temperature exceeds 30 degrees Celsius. Cooling the coolant extends the life of the deionizing cartridges.

10 TCU Model 2080 Operation and Maintenance (Revision B)

Page 25: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

TCU DescriptionOverview

Figure 1–2. Refrigeration Assembly-Right/Rear View

TU01C001Refgr Assy R R

������ ������

���������� ��

��������

�� �����������������

������ �����������

������

��� ��������������

!�����������

"���� #��

���������� ��

�� #� �

����� ������

$�����

���������%������

�� �������

$�������&���'�

�����������

"������������'�

������������ �� ����������

$������#�� �'���������

�����

�������'&����� ��#������

� (�� ��������������'�

$������������������'�

��������

��� ��#������

TCU Model 2080 Operation and Maintenance (Revision B) 11

Page 26: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SpecificationsOverview

Specifications

Table 1–1. Coolant and Facility Water Flow

Item descriptionFlowgpm (LPM)

PressurePSI

Temperature(° Celsius)

Upper channel coolant supply to system

4 (15.14) ± 0.5 (1.89) 60 ± 20 -15 to + 80

Lower channel coolant supply to system

4 (15.14) ± 0.5(1.89) 60 ± 20 -20 to + 80

Facility water supply requirements

6(22.72)±2 (7.56) 60 ± 20(100 max)

+10 to + 25

Table 1–2. General Specifications

Description Specification

Dimensions Height: 55.25 in. (140.34 cm)Width: 23.75 in. (60.33 cm)Depth: 37.75 in. (95.89 cm)

Weight 616 lbs. (279.42 kg) w/reservoirs empty690 lbs. (312.98 kg) w/ reservoirs full

Operating temperature range

−15 to + 80 degrees Celsius (upper channel)−20 to + 80 degrees Celsius (lower channel)

Temperature regulation

±1 degrees Celsius (±0.3 degrees Celsius typical) at rated static load

Setpoint resolution ±0.1 degrees Celsius

Power dissipation capability

Cooling: lower channel 1000 W at −20 degrees Celsius (3415 BTU/hr)upper channel 750 W at −15 degrees Celsius (2561 BTU/hr)Heating: upper/lower channel 1600 W(5464 BTU/hr)

Reservoir capacity 4.23 gallons (16 liters) per reservoir

Ambient operating temperature

+10 degrees Celsius to +40 degrees Celsius

Coolant composition

50/50 mixture by volume of DI water and ethylene glycol. This equates to a specific gravity of 1.065 ± 0.005 as measured with a hydrometer. Ethylene glycol should be laboratory grade or better.

Power requirements 3−phase 208/230VAC at 50−60 Hz, 30 A with10 kA Icu

12 TCU Model 2080 Operation and Maintenance (Revision B)

Page 27: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SpecificationsOverview

Front Control Panel

The front control panel (Figure 1–3) provides various controls, indicators, anddisplays. The controls turn the TCU on or off, as well as set parameters such astemperature setpoints and high and low temperature alarm limits. The indicatorsprovide a convenient means of monitoring system status. The digital displaysprovide a continuous readout of coolant temperature and resistivity andaccumulated operating hours.

Fuses 28V EMO Circuit = (2) 1A, 250V SLO BLOPower Supply = (1) 0.75A, 250V SLO BLO

Sound pressure level <75 dBA

Table 1–3. Coolant and Facility Water Interface Hardware Requirements

Item descriptionFittingSize/Type

LineSize/Type

Upper channel supply 1/2−inch Swagelok or equivalent 1/2−inch OD Nylon Tubing

Upper channel return 1/2−inch Swagelok or equivalent 1/2−inch OD Nylon Tubing

Lower channel supply 1/2−inch Swagelok or equivalent 1/2−inch OD Nylon Tubing

Lower channel return 1/2−inch Swagelok or equivalent 1/2−inch OD Nylon Tubing

Facility water supply 5/8−inch Swagelok or equivalent 5/8−inch OD Nylon Tubing

Facility water return 5/8−inch Swagelok or equivalent 5/8−inch OD Nylon Tubing

Reservoir drain (one per channel) 1/2−inch FNPT

CautionMechanical Hazard: During normal TCU operation, the condenser water valve continuously cycles on and off. This cycling motion can cause the facility water lines to undulate or jump around. When routing the cooling water lines, prevent the lines from rubbing against other objects.

Table 1–2. General Specifications (continued)

Description Specification

GENERAL ALERT

TCU Model 2080 Operation and Maintenance (Revision B) 13

Page 28: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SpecificationsOverview

Figure 1–3. Front Control Panel

Front Panel Controls

Main Controls

• Emergency Off (EMO) (red)—connected to the EMO circuitry of the system. Activation shuts down the TCU, system, RF generator, and all equipment included in the external EMO circuit.

• Power On (green)—turns the compressors and water pumps on.

• Power Off (black)—turns the compressors and water pumps off.

• Upper/Lower switch—activates the Temperature and Resistivity displays for the upper and lower channels.

Channel Control

There are two sets of channel controls, one set per channel.

• Set —selects between the temperature setpoint read mode and the temperature display mode for each channel. Temperature display mode is the default mode. It is active when the button is in its normal, unpressed position. When you press the Set button, the temperature setpoint appears on the temperature meter.

)������#����&

����

�������� #����� ����������

������������� �������

���������������� �������

*����� #�����

+""�'����

+,�'���� !���� �&��%%

-�� � #�����

����

��������� ��

14 TCU Model 2080 Operation and Maintenance (Revision B)

Page 29: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SpecificationsOverview

Local temperature set mode is enabled only when the TCU is in local control mode. When the TCU is in remote mode, the setpoint is specified as the Electrode Parameter on the etchers software on the Recipe page.

If the system is off, the TCU setpoint defaults to local setpoint.

• Temperature Set potentiometers—used in conjunction with the TEMP. SET buttons to set the temperature setpoint for each channel (enabled when the TCU is in local control mode only).

• Local Temperature Hi/Lo Set potentiometers—set the high and low setpoint alarm limits for each channel.

• Temperature Alarm Hi Set/Read, Temp Alarm Lo Set/Read two switches—used in conjunction with the TEMP. HI/LO potentiometers to set the high and low temperature setpoint alarm limits or display the current high or low temperature setpoint alarm limits.

• Temperature Alarm Reset—reset TEMP fault indicator only.

Front Panel Indicators and Displays

Main Indicators

• AC On (white)—illuminates when CB1 and CB6 are on and the main RESET button has been pressed.

• Fail (orange)—illuminates when the TCU has stopped running due to a system shutdown.

• Intlk (blue)—illuminates when all six panel interlocks are enabled and EMO’s are not activated (operational condition).

Depressing the alarm reset switches clears all of the following indicators in their respective channel.

• Status Indicators

System Shutdown:

These faults send a signal to the system. See Table 1–4.

TCU Model 2080 Operation and Maintenance (Revision B) 15

Page 30: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SpecificationsOverview

• Compressor—bicolor LED glows red indicating a system shutdown from high or low refrigerant pressures and glows green under normal operating conditions.

• Flow—bicolor LED glows red indicating a loss of coolant return flow from the system and system shutdown and glows green under normal operating conditions.

• Heater—bicolor LED glows red indicating overtemp failure and system shutdown and glows green under normal operating conditions.

• Level—bicolor LED glows red indicating the coolant level is below the safe limit for the TCU and indicates system shutdown and glows green under normal operating conditions.

Maintenance Required:

• Fill—bicolor LED glows red indicating the coolant level is low and that more coolant should be added and glows green under normal operating conditions.

• Resistivity—bicolor LED glows red indicating the resistivity of the coolant is not within proper operating limits and glows green under normal operating conditions.

Alarm Indicators

• Temperature Alarm Hi/Lo—illuminates to warn that a temperature high or low alarm limit has been exceeded.

Panel Meters

• Temperature—displays the current operating temperature of the coolant.

• Resistivity—displays the absolute resistivity of the coolant.

• Operational Hours—displays the total number of hours that the TCU has been operating.

16 TCU Model 2080 Operation and Maintenance (Revision B)

Page 31: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SpecificationsOverview

Rear Panel

The following is a listing of controls and connectors found on the rear panel of the TCU electronic enclosure (see Figure 1–4).

Figure 1–4. Rear Panel, Electronic Enclosure

Rear Panel Controls

• CB1—main circuit breaker with lockout bracket.

• CB2—circuit breaker for the lower pump.

• CB3—circuit breaker for the lower channel.

• CB4—circuit breaker for the upper pump.

• CB5—circuit breaker for the upper channel.

• CB6—circuit breaker for the electronics control.

./0/�!-+��� ����-��������(������� ����

!���� �&��%%� ��%��������./0��1�

�1/ �12 �13 �14 �15

TCU Model 2080 Operation and Maintenance (Revision B) 17

Page 32: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SpecificationsOverview

Rear Panel Connectors

72J1—37−pin connector for remote data transfer between TCU and system. See Table 1–4 for pinout.

72J2—9−pin connector for remote enable and EMO. See Table 1–5.

Table 1–4. Interface Connector 72J1

Function Connector 72J1 pin number

Lower channel temp setpoint 24

Lower channel temp setpoint return 5

Lower channel temp sense 20

Lower channel temp sense return 1

Upper channel temp setpoint 25

Upper channel temp setpoint return 6

Upper channel temp sense 21

Upper channel temp sense return 2

TCU fail 26

TCU fail return 7

TCU warning 28

TCU warning return 9

Table 1–5. EMO Connector 72J2

Function Connector 72J2 pin number

Remote EMO contact (normally closed) 1

Remote EMO contact return (normally closed) 2

TCU local/remote select 3

TCU local/remote select return 4

Internal EMO contact (normally closed) 5

Internal EMO contact return (normally closed) 6

Not used 7

Not used 8

Not used 9

18 TCU Model 2080 Operation and Maintenance (Revision B)

Page 33: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

EMO, Interlocks, and Safety CircuitsOverview

• Male Twist−Lock connector—accepts female AC power cable connector.

• Emergency Off (EMO) (red)—connected to the EMO circuitry of the system. Pushing the EMO button shuts down the system. Reset the EMO by twisting the button in the direction of the arrow.

EMO, Interlocks, and Safety Circuits

The TCU is equipped with safety features used to protect the operator from injury and to protect the equipment from damage.

Emergency Off

The front and rear panels of the electronic enclosure have an EMO. The EMOs are connected in series. When either EMO is pushed, contactor K1 opens, and 208 VAC is removed forward of the contactor. The interlock and subsystem safety circuits remain energized by 24 VAC. In addition, the remote EMO circuits open and affect the external equipment connected to J4.

The EMO circuit has two parallel loops. The first loop is powered by the remote equipment through connector 72J2 pins 1 and 2. The second is powered internally by the TCU, and is connected to external equipment through connector 72J2 pins 5 and 6 (see Figure 1–6).

If you plan to operate the TCU without an interface cable attached, then the TCU requires 72J2 pins 5 and 6 to be jumpered together. Use jumper assembly 853-017830-002.

Interlocks

The outer covers are interlocked stopping the operation of the TCU when one or more of the covers are removed. Pullout interlock switches are provided to override this safety feature when maintenance or testing is required.

TCU Model 2080 Operation and Maintenance (Revision B) 19

Page 34: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

EMO, Interlocks, and Safety CircuitsOverview

The interlock switches are in series with the internal EMO loop. Activating one of the interlocks opens contactor K1, and 208 VAC is removed after the contactor. The interlock and subsystem safety circuits remain energized by 24 VAC. However, the remote EMO loop remains closed and external equipment connected to 72J2 pins 1 and 2 is not affected.

Subsystem Safety Circuits

Subsystems that are potentially hazardous to the operator are monitored by sensors that detect conditions out of normal range (see Figure 1–5 and Figure 1–6).

In the coolant loop the following is monitored:

• Coolant temperature in the reservoir

• Coolant level in the reservoir

• Coolant return flow to the TCU

In the refrigeration loop, the following is monitored:

• Compressor high side pressure

• Compressor low side pressure

Each channel in the TCU has an identical set of sensors, but any failure will shutdown the TCU.

If a failure occurs, contactor K2 opens and 208 VAC is removed from the compressors and pumps. The control electronics and the EMO/Interlock circuitry remain energized. Relay K1 on the relay board is deenergized, which in turn deenergizes relay K2. The failure lamp lights up on the front panel. The ON and OFF buttons and the control circuit turn off.

20 TCU Model 2080 Operation and Maintenance (Revision B)

Page 35: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

EMO, Interlocks, and Safety CircuitsOverview

Figure 1–5. Schematic-Subsystem Safety Circuit

Figure 1–6. Schematic-TCU EMO/Interlock Circuit

4J5

COMPRESSORSWITCHES

RELAY BOARD

A1 K2 A2MAIN CONTACTOR

TEMP, LEVELHEATER FLOW

FAILSTATUSFROMCONTROLBOARD

4J5

4J728V

RETURN

K2B

28V

4J1K128VRETURN

28VRETURN

K2

TO FAIL LAMP

TO "ON/OFF" SWITCHCOMMON ON FRONTPANEL (28V)

TO "ON" SWITCHON FRONT PANEL4J2

K2A

K1A

AJ2

TU00C013

4J4-5

4J4-6

4P4

REMOTEEMO CIRCUIT

(PASSIVE)

28VRTN 4J7-6

4J7-4

ON FRONT PANEL

TO LAMP

J8-4

J8-1

4J7-5

4J7-3

4J2-12

4J2-9 J2-10 J4-1

J4-2

J2-11

J7-2

J7-1

FRONT EMO

REAR EMO

A2

A1

CONTACTORK1

1J9

REARTOP COVER REAR RIGHT LEFT FRONT

RELAY BOARDRELAY BOARD

REMOTEEMO CIRCUIT(ENERGIZED)

28V

TU01C017

P8

TCU Model 2080 Operation and Maintenance (Revision B) 21

Page 36: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

EMO, Interlocks, and Safety CircuitsOverview

22 TCU Model 2080 Operation and Maintenance (Revision B)

Page 37: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

2Installing the TCU

Facility Requirements

The following guidelines are provided to assist in placing and installing the TCU.

Prepare for installing the TCU by providing the following:

• Floor space. The floor space required for the TCU is 60 inches high by 24 inches wide by 38 inches deep, with a minimum 24−inch clearance for the front and rear of the unit.

• Facility water supply. Water−cooled refrigeration systems require 6 ± 0.5 gallons per minute (gpm) of water for cooling. The water pressure should not exceed 100 pounds per square inch (psi). The temperature of the water should be between +10 and +25 degrees Celsius.

WarningRespiratory Hazard: In the event of a catastrophic failure of the refrigeration units, oxygen displacement can occur within the facility. This can lead to breathing problems and/or possible asphyxiation. Be sure that the TCU is in a well ventilated area.

CautionEquipment Hazard: Do not start the TCU until all of the facility requirements are satisfied and all of the preparation and installation procedures in this section have been performed.

CautionEquipment Hazard: During normal TCU operation, the condenser water valve continuously cycles on and off. This cycling motion can cause the facility water lines to undulate, or jump around. When routing the cooling water lines, prevent the lines from rubbing against other objects.

POISON

HOT SURFACE

HOT SURFACE

23

Page 38: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Facility RequirementsInstalling the TCU

• Grounded electrical receptacle, with suitable over current protection. 208/230 VAC at 50 to 60 hertz, 3−phase, 30 amperes with 10 kiloampere (kA) interrupting current capability (Icu).

• Deionized water and ethylene glycol. Used for the coolant mixture. The contents should be 50 percent deionized (DI) water and 50 percent ethylene glycol (by volume) for both channels. The DI water should have a minimum resistivity of 10 megohm cumulative.

Note Used Ethylene Glycol may be considered a hazardous waste in your area. Contact your local environmental or other responsible agency for up−to−date information on proper disposal procedures.

Preparation

Safety

Type 1 task involved.

To prepare the system,

1 Unpack the TCU and inspect it. Lam recommends that you remove the outer covers and check all interior assemblies for tightness, particularly the pumps. Remove the compressor shipping clamps. Complete the inspection of the assemblies. Install the covers.

2 Locate the unit as desired. Ensure that the front and rear clearance is 24 inches minimum, and that the TCU is within 50 feet of the system. Ensure that the total length of the return and supply lines between the system and the TCU does not exceed 100 feet.

3 Lock all wheel locks.

WarningElectrical Hazard: Do not connect the TCU to the electrical service until you complete the following steps.

POISON

24 TCU Model 2080 Operation and Maintenance (Revision B)

Page 39: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Facility RequirementsInstalling the TCU

4 Prevent damage to the TCU, due to movement caused by earthquakes, by anchoring the system to the floor through the four holes provided on the lower left and right sides of the frame (see Figure 2–1). The customer is responsible for the following tie−down components:

• 1/4 inch 20 x 2 inch (or M6x50) mounting bolts. Use grade 4.6 or better.

• 1/4 inch 20 (or M6) fastening nuts. Use grade 4 for grade 4.6 bolts, and grade 6 for all bolts grade 6.6 or better.

• External floor mounts. Floor mounts must accommodate a minimum of 837 inch foot pounds, ability to withstand a minimum of 150 foot pounds displacement force, and 3941 psi of shear stress.

TCU Model 2080 Operation and Maintenance (Revision B) 25

Page 40: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Facility RequirementsInstalling the TCU

Figure 2–1. Rear Panel Installation Connectors and Controls

Note The center of gravity (CG) for the TCU filled with the coolant is shown in Figure 2–2. The dimensions are measured from the outer edge of the TCU frame. The height of the CG is 24.5 inches from the ground.

TU01C004Lt Rr OverVw 20

!-+*������

� ��%����

�� ����

�1/������

�15

�������� ������&

�� ����

�������� �����

�� ����

�������� ������&

�� ����

�������� �����

�� ����

$����� ���%����� ���� �

* ���� �����

"������&���������&

�� ����

"������&��������

�� ����

����������%��������

+��%�����

+��%���#��

��� ��#��

$������%���� #�����!-+

�� ����./0/

�1�� �������'�����

����������%��������

�� �����

�������3

��� ��#��

$������%���� #�����

./0���� ����

26 TCU Model 2080 Operation and Maintenance (Revision B)

Page 41: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Facility RequirementsInstalling the TCU

Figure 2–2. Center of Gravity-Top View

Safety

Type 1 task involved.

Installing the TCU

To install the TCU,

1 Prior to installing the TCU, disconnect the TCU power cord from the facility branch circuit connection. Do not operate the TCU without the system supply and return lines connected.

2 Lam recommends that you open the facility water return line valves before the supply valves to prevent shock to the system and its components. Be careful not to overtighten any valves.

3 Install the TCU to Lam standalone systems (see Figure 2–1 and Figure 2–3). Install the TCU to multi-chamber systems or OEM applications (see Figure 2–1 and Figure 2–4).

4 Attach the TCU coolant supply and return lines to the corresponding connectors.

5 Ensure proper flow rates by not reducing the line size from the TCU. Coolant connections are to have 1/2−inch Swagelok connectors with nylon ferrules.

�� ����%������&

"� �

��64�� ���

�46/4�� ���

TCU Model 2080 Operation and Maintenance (Revision B) 27

Page 42: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Facility RequirementsInstalling the TCU

6 Connect the facility water supply and return to the proper connectors on the rear panel of the TCU.

7 Connect the EMO cable from 72J2 on the rear panel of the TCU's electronic enclosure to the system. Connect the interface signal cable provided with the system to 72J1 on the rear panel of the TCU's electronic enclosure.

8 Plug the TCU power cord into the AC power connector on the rear panel of the electronic enclosure and connect it to a 50/60 hertz, 30 amperes, 208/230 VAC, 3−phase receptacle (facility branch circuit).

9 Ensure that the twistlock connectors are correctly aligned and fully inserted into the receptacle. Rotate the connector clockwise to lock it in position.

WarningFire Hazard: Failure to properly seat the connector can result in arcing and possible fire hazard. Ensure that the connector is properly seated.

FIRE

28 TCU Model 2080 Operation and Maintenance (Revision B)

Page 43: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Facility RequirementsInstalling the TCU

Figure 2–3. TCU Facility/Electrical Installation for Lam Standalone

��� ��������

������

����

����

������

*��� ����'������

/�7 /2��8*��2(����4� 5���9�2��*����������

"������&����������5:�64�;�-<���=�����/4=�<���������6

"������&���������

����� ��%������'���>742(��.?53(�@

����!-+���'���>742(��.7/3(�@

�����������#

����� ��>� /(� ���+)<�4�(%�������@

"������&������� �>4 7(� ���+)@

"������&����������>4 7(� ���+)@

$������*��'��

����� ��>� /(� ���+)<�4�(%�������@

����� ��>� /(� ���+)<�4�(%�������@

����� ��>� /(� ���+)<�4�(%�������@

��� ��'��������1

!����� ��� �����

�������������� ����

��������

����&��� ����

�����������

���� �������������

�����

�����������

�����

������������

�����

�����������

�����

������������

�����

������������

��

��� ��

�������� ��

�����

������������

TCU Model 2080 Operation and Maintenance (Revision B) 29

Page 44: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Facility RequirementsInstalling the TCU

Figure 2–4. TCU Facility/Electrical Installation -Multi-chamber System/OEM

��� �������������

��������

����

����

/�7 /2��8*��2(����4� 5���9�2��*����������

"������&����������5:�64�;�-<���=�����/4=�<���������6

"������&���������

����� ��%������'���>742(��.?53(�@

����!-+���'���>742(��.7/3(�@

�����������#

����� ��>� /(� ���+)<�4�(%�������@

"������&������� �>4 7(� ���+)@

"������&����������>4 7(� ���+)@

$������*��'��

����� ��>� /(� ���+)<�4�(%�������@

����� ��>� /(� ���+)<�4�(%�������@

����� ��>� /(� ���+)<�4�(%�������@

!����� ��� �����

�������������� ����

"������&����&��� ����

�����������

���� �������������

�����

�����������

�����

������������

�����

�����������

�����

������������

�&������ ���������� ��

�&����!-+�������

� ���

������

��������

� ���

������

30 TCU Model 2080 Operation and Maintenance (Revision B)

Page 45: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

3Start-Up

This chapter contains the start-up procedure for the TCU Model 2080.

Always follow your company’s safety practices, in addition to the safety guidelines noted in the procedures. Make sure to use the proper equipment and observe all cautions and warnings.

Before proceeding, see the safety information in Chapter 1, "Overview."

31

Page 46: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Start-Up

32 TCU Model 2080 Operation and Maintenance (Revision B)

Page 47: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

3.1Starting the TCU

The following procedure lists the steps required to perform the initial start−up for the TCU. You do not need any special equipment for this procedure. The only tool required is a small, standard screwdriver.

Safety

Type 2 task involved.

Preparation

See Figure 3.1–1 when performing the steps in this section.

To warm−up the TCU,

1 Ensure that all protective covers are in place and secured.

2 Plug the TCU power cord into the AC power connector on the rear panel of the electronics enclosure. Connect it to a 30 amperes, 208/230 VAC, 3−phase receptacle. Ensure that the twistlock connectors are fully inserted into their receptacles. Rotate connectors clockwise to lock in position.

3 On the rear panel, turn on CB1 through CB6.

4 Allow the heater to run for approximately 120 minutes before proceeding. If the TCU has been exposed to temperatures below freezing, the oil in the compressor thickens. Allow the unit to warm up at room temperature for a minimum of 24 hours.

WarningFire Hazard: Failure to properly seat the connector can result in arcing and possible fire hazard. Ensure that the connector is properly seated.

FIRE

33

Page 48: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureStarting the TCU

5 On the front control panel of the electronics enclosure (see Figure 3.1–1), press the Temperature Alarm Reset buttons for both channels. This clears both Hi and Low temperature alarms. Press any of the System Shutdown and Maintenance Required buttons to reset all six status indicator alarms. Flow indicators turn red again after approximately 5 to 10 seconds unless the TCU is turned on and the proper flow has been established.

Procedure

To start-up the TCU,

1 Foaming of the compressor oil may decrease the life or reliability of the compressor. Prevent foaming of the oil upon start−up of the unit by performing the following:

• Apply power to the TCU.

• Turn on CB1 and CB6. This energizes a heater for the compressor and removes dissolved refrigerant from the compressor oil.

2 Fill the coolant reservoirs. See Section 4.2, "Filling the Reservoir."

3 Locate the circuit breaker switches on the rear panel of the electronics enclosure of the TCU. Turn on CB2 through CB5.

Purging the TCU

To purge the TCU,

1 If the resistivity indicator for either channel remains red, the resistivity of the coolant is below 1 megohms absolute. The TCU may need to operate for 24 hours before the resistivity of the coolant rises above 1 megohms absolute.

34 TCU Model 2080 Operation and Maintenance (Revision B)

Page 49: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Purging the TCUStarting the TCU

Figure 3.1–1. Status/Alarm Indicators and Reset Buttons

Note If one or more status indicators remain red after pressing the Reset button, you must correct the problems associated with those indicators before proceeding. The TCU does not operate when the Comp, Heat, Flow, or Level indicators are red. See Chapter 6, "Troubleshooting." When all problems have been corrected, proceed to step 2.

2 On the front control panel of the electronics enclosure, press the Temperature Alarm Reset buttons for each channel. Both sets of Temperature Hi/Low alarm indicators should turn from red to green. This step resets the temperature alarms.

Note If any alarm indicators remain lit, proceed to the next step to check the high and low temperature alarm limits for that channel.

3 Check the high and low temperature limits by performing the following:

• On the front control panel (see Figure 3.1–2), push either the Upper or Lower channel selector for the desired channel.

• Push the Temperature Alarm Set button to check the high temperature alarm limit setpoint or push the Temperature Alarm Low button to check the low temperature alarm limit setpoint. The digital temperature display shows the current temperature alarm setpoint for the selected channel.

������������������

�����������������

��������������

���

TCU Model 2080 Operation and Maintenance (Revision B) 35

Page 50: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Purging the TCUStarting the TCU

If the limits do not reflect the system operating temperatures, adjust the limits as required by following the procedure detailed in the next step.

4 Adjust the hi/low temperature limits, by performing the following:

• On the front control panel of the electronics enclosure (see Figure 3.1–2), push either the Upper or Lower button to select either the upper or lower channel.

• Push either the Temperature Alarm Hi or Low Setpoint button. The Temperature display shows the current high or low limit alarm setpoint for that channel.

• Using a small, standard screwdriver, adjust the temperature limit alarm setpoints by rotating the Temperature Hi potentiometer for the high limit or the Temperature Low potentiometer for the low limit. Decrease the setpoint by rotating the potentiometer counterclockwise. Increase the setpoint by rotating the potentiometer clockwise.

• Check the new setpoints by pressing the Temperature Hi/Low Reset Alarm button for the desired channel. The status and alarm indicators should all turn off.

Figure 3.1–2. Hi/Low Temperature Controls and Meter

��� ��������

���������#����&

������������������ �������

������������������

�����������������

����������������

����������������� �������

36 TCU Model 2080 Operation and Maintenance (Revision B)

Page 51: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Purging the TCUStarting the TCU

5 If all interlock and EMO conditions have been satisfied, the Fail lamp turns off and the blue Intlk lamp illuminates (seeFigure 3.1–3).

Note Approximately 5–10 seconds after resetting the status indicators, the flow sensor reports a failure if the system flow has not been established.

Figure 3.1–3. Fail Indicator"��������

TCU Model 2080 Operation and Maintenance (Revision B) 37

Page 52: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Purging the TCUStarting the TCU

38 TCU Model 2080 Operation and Maintenance (Revision B)

Page 53: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

4Maintenance

The dual channel TCU is designed to provide reliable, long term operation with a minimum of service. The assemblies and components are easily accessible for both maintenance and repair.

Always be careful when you are performing any maintenance on the TCU. Be sure to observe the specific safety cautions and warnings when servicing this unit see Chapter 1, "Overview." See Appendix A, "Reference Documentation." for information on obtaining Material Safety Data Sheets.

Troubleshooting Precautions

If you need to perform troubleshooting procedures when the power is on, be sure to observe the following warning:

WarningMechanical Hazard: The refrigeration units are hermetically sealed. No user serviceable parts are inside. Any maintenance on this equipment should be performed only by trained and licensed refrigeration personnel.

WarningPhysical Hazard: The coolant and refrigeration system components change temperature drastically in both the heating and cooling modes of operation. Use extreme caution when working on these units. Some refrigeration components can reach temperature up to 300 degrees Fahrenheit (149 degrees Celsius).

WarningElectrical Hazard: Voltages from circuitry within the TCU can cause severe injury or death. Contact with 208 VAC (3 ∅) and 28 VAC circuitry is possible in the rear half of the electronic enclosure. Avoid any physical contact or placement of tools within the rear half of the electronic enclosure. In addition, DC voltages ranging from 5 VDC to 15VDC are present. Only trained, qualified personnel should perform any maintenance on this unit.

GENERAL ALERT

HOT SURFACE

ELECTRICAL

39

Page 54: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Troubleshooting PrecautionsMaintenance

40 TCU Model 2080 Operation and Maintenance (Revision B)

Page 55: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

4.1Preventive Maintenance

Lam recommends that you adhere to the following maintenance schedules to ensure that the TCU continues to function as specified.

Monthly PM Schedule

To perform the monthly preventive maintenance,

1 Check for leaks or condensation under, inside, and behind the TCU. Investigate and repair any abnormalities. See Chapter 6, "Troubleshooting."

2 Check the coolant specific gravity. For coolant composition and specific gravity, see Table 1–2 in Chapter 1, "Overview."

3 Analyze resistivity measurements from the last several weeks. Replace the polishing cartridges if the measurements are approaching default alarm setting (1 megohm absolute) or minimum process requirements. See Section 4.5, "Checking the Operation of the TCU."

Note Resistivity varies with temperature. High temperatures result in lower resistivity and conversely, low temperatures result in higher resistivity. Ensure that the TCU is at the same operating temperature each week when taking resistivity measurements. The TCU must also be running for at least 24 hours to ensure a proper resistivity reading.

41

Page 56: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Monthly PM SchedulePreventive Maintenance

42 TCU Model 2080 Operation and Maintenance (Revision B)

Page 57: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

4.2Filling the Reservoir

Use this procedure to fill the TCU reservoir.

Safety

Type 2 task involved.

Equipment Required

• Sixteen liters coolant (50/50 mixture by volume, DI water/ethylene glycol)

• Safety goggles, uniform, apron, and rubber gloves

• Funnel

• Several cloths (for spillage)

Procedure

To fill the TCU reservoir,

1 Locate the reservoir fill ports near the rear panel of the electronic enclosure (see Figure 4.2–2). Remove the fill plugs from the reservoir fill ports.

2 Using the funnel, fill one of the tanks with coolant consisting of a 50/50 mixture (by volume) of deionized water and ethylene

CautionPhysical Hazard: Be careful not to overfill the coolant reservoirs. Over filling causes the excess coolant to flow from the vent line located at the lower rear of the TCU (see Figure 4.2–2). Any over flow should be captured and disposed of in accordance with local, state and federal regulations. The reservoir tank capacity is 4.2 gallons (16 liters).

GENERAL ALERT

43

Page 58: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureFilling the Reservoir

glycol. Note that since the tanks are not full, both FILL limit indicators on the rear electronics enclosure are not illuminated.

3 Continue to add the coolant, until the FILL indicator light on the rear of the TCU illuminates. Add 20 to 30 fluid ounces of coolant after the FILL LED illuminates. The coolant is now at the proper level.

4 Once the tank is full, press the status indicator LEVEL and FILL Reset buttons on the front panel (see Figure 4.2–1) for the reservoir tank being filled, either upper or lower. The LEVEL and FILL indicators reset from red to green.

5 Repeat steps 3 and 4 for the other tank and when topping off.

Figure 4.2–1. Status Indicator Reset Buttons

WarningEquipment Hazard: The Lam specified 50/50 ethylene glycol/DI water mixture is required to properly lubricate the pump and to protect the coolant reservoir from freezing and cracking. Filling the reservoirs with anything other than the specified 50/50 coolant mixture will void the customer warranty.

GENERAL ALERT

����������������

44 TCU Model 2080 Operation and Maintenance (Revision B)

Page 59: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureFilling the Reservoir

Figure 4.2–2. Circuit Breakers and Reservoir Fill Ports

TU01C004Lt Rr OverVw 20

!-+*������

� ��%���

�� ����

�1/������

�15

�������� ������&

�� ����

�������� �����

�� ����

�������� ������&

�� ����

�������� �����

�� ����

$����� ���%����� ���� �

* ���� �����

"������&���������&

�� ����

"������&��������

�� ����

� ��%����� �����

����������%��������

+��%�����

+��%���#��

��� ��#��

$������%���� #�����!-+

�� ����./0/

�1�� �������'�����

����������%��������

�� �����

�������3

��� ��#��

$������%���� #�������� ����

./0�

TCU Model 2080 Operation and Maintenance (Revision B) 45

Page 60: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureFilling the Reservoir

46 TCU Model 2080 Operation and Maintenance (Revision B)

Page 61: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

4.3Replacing the Refrigerant

In order to comply with current Environmental Protection Agency (EPA) regulations that restrict the use of R403B (69L) refrigerant in semiconductor applications, Lam has selected refrigerant R404A as a replacement.

The following procedure describes the method for replacing refrigerant R403B (69L) with refrigerant R404A. Replacement is not required unless the system needs more refrigerant. Replacement is limited to only the later 2080 TCU systems.

Reference Documentation

None

Equipment Required

• Refrigerant R404A

• Refrigerant pressure gauge set

• Vacuum pump

• Vacuum gauge

• 5/16-inch square refrigeration (or adjustable) wrench

• Refrigerant scale (accuracy: ±0.5 of an ounce)

• Approved refrigerant recovery unit

47

Page 62: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SafetyReplacing the Refrigerant

Safety

Type 2 task involved.

Preparation

None

Procedure

To charge the refrigerant,

1 Charge the system only with refrigerant R404A. Charge the upper channel with 1 pound, 4.0 ounces and the lower channel with 1 pound, 6.0 ounces. See Section 4.4, "Charging the Refrigerant."

2 Turn the TX valve five turns clockwise from the fully open position.

3 Set the high-pressure cutout switch to 400 psi.

4 Perform Section 4.5, "Checking the Operation of the TCU."

CautionEquipment Hazard: The refrigeration units are hermetically sealed. No user-serviceable parts are inside. Only trained maintenance personnel should perform maintenance on this equipment.

Prior to opening this sealed system for either repair or parts replacement, recover all refrigerant in accordance with EPA standards (as required under section 608 of the Clean Air Act of 1990) or applicable local regulations.

The refrigeration units are sensitive to the amount of refrigerant charge. Charge only with the proper equipment. The refrigerant type and the amount of charge are indicated in the charging procedure. Do not attempt to adjust the charge. An overcharge or undercharge of as little as 2.0 ounces causes critically high refrigerant pressures or substantial loss of capacity.

GENERAL ALERT

48 TCU Model 2080 Operation and Maintenance (Revision B)

Page 63: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureReplacing the Refrigerant

5 Locate the label for refrigerant type on each compressor (covered with black tape). The color of the label is half orange and half green. Cut and peel off the tape from the left side of the label to reveal the text “R404A.”

6 Remove the 69L label on each compressor and replace it with the new R404A label (785-111064-101 and 785-111064-102).

7 Install the new R404A label (785-111065-101) on the back of the TCU next to the serial number label.

8 Install the new label “WITH R404A” (785-111066-101) on the back of the electronic enclosure, cover the silk-screen text “WITH R403B” (see Figure 4.3–1).

Note Note, if the system has already been upgraded, do not perform steps 5 through 8.

Figure 4.3–1. Electronic Enclosure

����������AB����$3�21C

TCU Model 2080 Operation and Maintenance (Revision B) 49

Page 64: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureReplacing the Refrigerant

50 TCU Model 2080 Operation and Maintenance (Revision B)

Page 65: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

4.4Charging the Refrigerant

In compliance with the current EPA regulations that restrict the use of R403B (69L) refrigerant in semiconductor applications, Lam has selected refrigerant R404A as a replacement.

Prior to opening this sealed system for either repair or parts replacement, recover all refrigerant in accordance with EPA standards (as required under section 608 of the Clean Air Act of 1990) or applicable local regulations.

The refrigeration units are sensitive to the amount of refrigerant with which they are charged. Charge only with the proper equipment. The factory charge for these systems is noted on the individual compressor label. Do not attempt to adjust the charge. An overcharge or undercharge of as little as 2.0 ounces causes critically high refrigerant pressures or substantial loss of capacity.

Safety

Type 2 task involved.

Equipment Required

• Refrigerant R404A

• Refrigerant pressure gauge set

• Vacuum pump

• Vacuum gauge

CautionMechanical Hazard: The refrigeration units are hermetically sealed. No user serviceable parts are inside. Any maintenance on this equipment should be performed only by trained and licensed refrigeration personnel.

GENERAL ALERT

51

Page 66: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureCharging the Refrigerant

• 5/16 inch square refrigeration (or adjustable) wrench

• Refrigerant scale (accuracy: ±0.5 ounces)

• Approved refrigerant recovery unit

Procedure

Charging The Channels

To charge the channels,

1 Completely power down the TCU.

2 Remove the protective caps from the access port and 3−way service valve. Connect the red hose of the gauge set to the high−pressure side of the compressor and the blue hose to the low−pressure side (see Figure 4.4–1). Ensure that all refrigerant is recovered in accordance with applicable standards. Repair or replace faulty parts, then leak check the system. Connect a vacuum pump to the center port of the gauge set.

3 Open the 3−way service valve with the 5/16−inch wrench, turning the valve adjustment six turns in a clockwise direction (see Figure 4.4–1).

4 On the gauge set, open both the red and blue valves by turning the valve handles fully counterclockwise.

CautionPhysical Hazard: Surface temperatures on the compressor and attached lines can become extremely hot and cause severe burns. Avoid contact with these surfaces. If components need servicing, allow sufficient time for the unit to cool down.

HOT SURFACE

52 TCU Model 2080 Operation and Maintenance (Revision B)

Page 67: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureCharging the Refrigerant

Figure 4.4–1. Gauge Set Connection Points-Refrigerant Charging

5 Evacuate the refrigerant loop by turning the vacuum pump on, and pumping the system down to 500 microns.

6 After pumping down the refrigerant loop, close both the red and blue valves on the gauge set by turning the valve handles fully clockwise.

7 Remove the vacuum pump line from the gauge set and connect the charging system in its place. Ensure that air is not trapped in the line by using previously purged lines with automatic shutoff valves. This ensures that no air enters the refrigeration system and that no refrigerant escapes into the atmosphere.

Note Charge with a measured liquid charge through the high−pressure side only.

8 Open the charging valve, then open the valve on the high−pressure side on the gauge set.

9 Open the refrigerant tank valve.

TU01C001Refgr Assy R R

������

2(��&������������>%�(�#���%�������@

8������#D���� �

>%�(�#���%�������@

1�������

�����������������

>%�(�#���%�������@

$�#����

>������������������@

"���� #��

��������

TCU Model 2080 Operation and Maintenance (Revision B) 53

Page 68: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureCharging the Refrigerant

10 Charge the sytem with R404A. Charge the upper channel with 1 pound, 4 ounces and the lower channel with 1 pound, 6 ounces.

11 After charging is complete, close the refrigerant tank valve, then the gauge set valves.

12 Turn the 3−way service valve counterclockwise and fully seat the valve in the closed position. Replace the black plastic cap and remove the hose. Install the brass knurled cap on the access port.

13 Remove the hose from the high−pressure side port and install the brass knurled cap on the access port.

14 Power up the TCU.

54 TCU Model 2080 Operation and Maintenance (Revision B)

Page 69: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

4.5Checking the Operation of the TCU

Perform an operational check after charging both channels on the TCU. This ensures that the charging procedure was successful and that the unit is meeting performance specifications.

Safety

Type 2 task involved.

Equipment Required

• Small, standard screwdriver

Preparation

None.

Procedure

Note Ensure that the system is in local mode.

To perform the operational check,

1 Operate the TCU at a setpoint of +20 degrees Celsius for 15 minutes.

2 Using the front control panel (see Figure 4.5–1 ), perform the following:

• Select the upper channel by pushing the button marked Upper.

• Depress and hold down the Local Temp Set button for the upper channel.

55

Page 70: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureChecking the Operation of the TCU

• Continue holding down the Local Temp Set button and use a small, standard screwdriver to turn the Local Temp Set potentiometer. Turn the potentiometer until the temperature display reads +80 degrees Celsius.

• Select the lower channel by pushing Lower.

• Press and hold down Local Temp Set for the lower channel.

• Continue holding down the Local Temp Set button and use a small, standard screwdriver to turn the Local Temp Set potentiometer. Turn potentiometer until the temperature display reads −20 degrees Celsius.

Figure 4.5–1. Front Control Panel

3 Allow both channels to operate at their respective setpoints see Table 1–2 in Chapter 1, "Overview."

4 Change the setpoints for each channel as follows:

• The upper channel setpoint = −15 degrees Celsius

• The lower channel setpoint = +80 degrees Celsius

Note Changing the setpoints for each channel takes approximately 45 minutes.

5 Allow both channels to operate at these setpoints for one hour.

��� ��������

���������#����&

������������������ �������

������������������

�����������������

����������������

����������������� �������

56 TCU Model 2080 Operation and Maintenance (Revision B)

Page 71: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureChecking the Operation of the TCU

6 If either channel does not cool down to its respective setpoint(−15 or −20 degrees Celsius), See Chapter 6, "Troubleshooting," “TCU does not cool down.”

TCU Model 2080 Operation and Maintenance (Revision B) 57

Page 72: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureChecking the Operation of the TCU

58 TCU Model 2080 Operation and Maintenance (Revision B)

Page 73: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

4.6Replacing Coolant Polishing

Filter Cartridges

Use this procedure to replace the TCU coolant polishing filter cartridges.

Safety

Type 2 task involved.

Equipment Required

• Strap wrench

• Four coolant polishing cartridges (775−091420−001)

• Safety goggles, uniform, apron, rubber gloves

• Cloths (for spillage)

Figure 4.6–1. Coolant Polishing Cartridges

���� ���� ���

���� ��� ������

"��������#

����� �������� ������#��

59

Page 74: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureReplacing Coolant Polishing Filter Cartridges

Procedure

To replace the coolant polishing filter cartridges,

1 On the front control panel, press the Power Off button to turn off the TCU (see Figure 4.6–2).

2 On the rear panel of the electronic enclosure, turn CB1, the main circuit breaker, off (see Figure 4.6–3).

Figure 4.6–2. Front Control Panel

Figure 4.6–3. TCU Rear Panel

3 Locate the coolant polishing canisters, (two per channel, four total) mounted on the rear panel of the TCU (see Figure 4.6–1). Remove the housing insulation sleeves by sliding them off the canisters.

��� ��������

���������#����&

������������������ �������

������������������

�����������������

����������������

����������������� �������

�1�

60 TCU Model 2080 Operation and Maintenance (Revision B)

Page 75: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureReplacing Coolant Polishing Filter Cartridges

4 Using a strap wrench, loosen and remove the filter housing canisters.

Note When removing the polishing cartridges, coolant will spill and drip from the cartridges. It is recommended to use lint-free wipes to clean up any spilled coolant.

5 Remove the coolant polishing cartridges from the canisters and discard them.

6 Clean all film and sediment from the inside of the housing canisters, and rinse the canisters with DI water.

7 Clean the underside of the mounts.

8 Place a new polishing cartridge into each canister.

Note Before installing the canisters, ensure that the O−rings are seated correctly to prevent leaking and damaging the O−ring.

9 Install the housing canisters and tighten. Install the insulation sleeves.

10 On the rear panel of the TCU, turn CB1 on (see Figure 4.6–3).

11 On the front control panel of the TCU, press all RESET buttons (see Figure 4.6–2).

12 Refill the coolant reservoirs. See Chapter 4.2, "Filling the Reservoir."

13 On the front panel of the TCU, press ON to turn on the TCU.

14 Check for leakage from the coolant cartridges.

TCU Model 2080 Operation and Maintenance (Revision B) 61

Page 76: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureReplacing Coolant Polishing Filter Cartridges

62 TCU Model 2080 Operation and Maintenance (Revision B)

Page 77: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

5Calibration

This chapter contains procedures for calibrating the TCU Model 2080.

Always follow your company’s safety practices, in addition to the safety guidelines noted in the procedures. Make sure to use the proper equipment and observe all cautions and warnings.

Before proceeding, see the safety information in Chapter 1, "Overview."

63

Page 78: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Calibration

64 TCU Model 2080 Operation and Maintenance (Revision B)

Page 79: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

5.1Calibrating the Temperature Probe

In order for the temperature probes to accurately track the reservoir liquid temperature for each channel, check the three potentiometers on the TCU control printed circuit board (PCB)(see Figure 5.1–1) to ensure that they are properly adjusted. The potentiometers are as follows:

• VR1 adjusts the scale factor for both upper and lower channel temperature probes. Temperature probes are preset to −2.7316 ± 0.0001 VDC.

• VR104 adjusts the upper channel remote temperature compensation See Section 5.2, "Adjusting the Remote Temperature Offset." The temperature compensation is preset to 0.000 ± 0.001 VDC.

• VR204 adjusts the lower channel remote temperature compensation. See Section 5.2, "Adjusting the Remote Temperature Offset." The temperature compensation is preset to 0.000± 0.001VDC.

Safety

Type 3 task involved.

Equipment Required

• Digital voltmeter

• Small, standard screwdriver

WarningElectrical Hazard: Power is applied to the Control PCB when performing calibration procedures. Accidental contact with components operating at less than 30 VDC is possible. Avoid contact unless adjusting potentiometers.

ELECTRICAL

65

Page 80: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

MaterialsCalibrating the Temperature Probe

Materials

• Glyptal™

Procedure

To calibrate the temperature probe,

1 Remove the electronics enclosure cover.

2 Remove the two hinge screws on the front panel, releasing the front panel. Pull the panel forward.

3 Pull out the interlock switches.

4 Power on the TCU. Allow five minutes for warm−up.

5 Connect the negative lead of the voltmeter to TPG3. Connect the positive lead to the test pins listed, and verify that the voltage readings are within the ranges shown.

These voltages are derived from the DC power supply. If any are out of specification, it is most likely a power supply problem.

6 Connect the positive lead of the voltmeter to the test pins listed, and verify the voltage readings are within the ranges shown.

These voltages are generated locally on the control PCB (see Figure 5.1–1). If any are out of specification, replace the control PCB.

TP9 4.85 to 5.15 VDC

TP11 14.25 to 15.75 VDC

TP13 −14.25 to −15.75 VDC

TP5 −4.940 to −5.060 VDC

TP7 8.273 to 8.393 VDC

TP8 9.950 to 10.050 VDC

66 TCU Model 2080 Operation and Maintenance (Revision B)

Page 81: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureCalibrating the Temperature Probe

7 Connect the positive lead of the voltmeter to the test pin listed, and verify that the voltage reading is within range.

This voltage is precision set (using a 5.5 digit voltmeter) at the factory to −2.7316 ± 0.0001 VDC. If it is necessary to make adjustments in the field, adjust VR1 until TP6 reads −2.743 ± 0.000. The voltage controls the temperature accuracy of the upper and lower channels.

8 Connect the negative lead of the voltmeter to TPG2. Connect the positive lead to TP112, and adjust VR104 until TP112 is 0.000 ± 0.001 VDC.

9 Connect the positive lead of the voltmeter to TP212. Adjust VR204 until TP212 is 0.000 ± 0.001 VDC.

10 Apply a small amount of Glyptol to all of the potentiometers that were adjusted.

11 Remove all test leads. Secure the front panel using two hinge screws, and replace the electronics enclosure cover.

TP6 −2.731 to −2.733 VDC

TCU Model 2080 Operation and Maintenance (Revision B) 67

Page 82: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureCalibrating the Temperature Probe

Figure 5.1–1. TCU Controller PCB

NOALM/ALMR23

D3 R24TP

G3

TP

10

TP

12

1 2

JP1

J109

TP

G2

1

TP

106

TP

103

TP

206

TP

204

TP

112

R11

6

Q10

1

TP

108

TP

109

TP

110

TP

107

R22

R23

D10

4

Q10

5C

113

C14

1C

142

C14

3

RN102VR104

R141

R140

R240

R243 U283

U11 VR204

TP105

C121

R113

R112

C122

Q102

C136

C114

U104

C102

C135

R103

C26

U101

RN101

RN101C29

C31

Q203

Q202

RN207

XXX

U204

C214

U201

C20

Q2

C13

JP2

C235R2

L3

L1

L2

R1

R15

C12

C8

C2

C5

C7

TP67

RF DEAD

RF DEAD

RF DEAD

C1

C4

C11

U206

C220

C223

U105

U3

R109

C110

C30C28

C210

U205

U108

U109

06

24

06

24

06

24

06

24

U10

2U

103

TP

104

R11

4

J2C

23

Q10

0Q

107

R11

0

C12

8

C12

01R

216

TP

RG

R13

9

R10

0

R20

9

J8

J10

TP

212

203

C21

8

C12

3R

N11

0R

N10

6R

N11

5

C11

6 C21

6

C11

7C

217

C11

8R

116C

22R

215

TP

G6

24

RN

206

RN

210

RN

208

R21

0

TP

210

TP

209

R21

4D

207

D20

9D

208

D20

6

U20

2U

203

J209

1T

P20

5

R20

9R

208

R21

2C

219

R21

1R

213

C22

1

D10

9

RN

100

RN

104

R10

4

RN

103

D10

2

D10

8

D10

6

C10

7

C10

8

C10

9C

119

C11

5

D10

3

J101

1

C10

9R

105

R10

7

C10

4

C10

4

C10

7

C10

8

C10

6

C10

0

C10

1

R10

1

R10

2C

105

13

2

1

32

VR

103

VR

203

VR

103

VR

203

UR

T

J201

R11

1

CL5

1T

P21

1

TP

208

TP

207

TP

5

R20

1

R20

2

C20

1

C26

3

C20

3C18

C23

4

C20

2

C20

5C

239

C20

7R

207

R20

5

C23

7R

N20

3

D20

2

D20

3

RN

204

C21

5C

204

C23

6R

N20

1

R29

4

C20

9

C22

2

C20

8

C20

6IL

3

LRT

C10 U

1T

P9

TP

11

TP

13

+5V

+15

V-1

5V

C9

C3

C6

J7J5

TP

8

TP

7

1C

14

R4

R10

R12

R3

R8

1

C17

R9

C15

U2

R11

C19

R7

R5

R6

U18

R14

R18

BP

1B

P1 BLK

NF

Z/F

ZN

FZ

/FZ

JP10

1JP

201

R10

6

C18

D20

1

D10

1

TP

6T

P11

1

VR

1

R28

R20

6

RE

DQ

1

TU01C019Chiller Control PCB

��

�� �

�� �

����

����

���

����

����

���

���

���

���

�����

�������?

68 TCU Model 2080 Operation and Maintenance (Revision B)

Page 83: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

5.2Adjusting the Remote Temperature Offset

Use this procedure to compensate for coolant temperature differences between the TCU and the main system due to losses in the coolant lines. These lines can run up to 50 feet in length.

Safety

Type 2 task involved.

Equipment Required

• Small, standard screwdriver

Materials

• Glyptal™

Procedure

To adjust the remote temperature offset,

1 Determine the coolant temperature being received from the upper channel of the TCU by the main system. Observe this by selecting the appropriate screen display.

2 Turn the TCU on, then select the upper channel. Quickly adjust potentiometer VR104 until the temperature that appears on the front panel of the TCU matches the temperature of the system.

3 Determine the coolant temperature being received from the lower channel of the TCU by the main system. Observe this by selecting the appropriate screen display at the system.

69

Page 84: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureAdjusting the Remote Temperature Offset

4 Turn the TCU on, and select the lower channel. Quickly adjust potentiometer VR204 until the temperature that appears on the front panel of the TCU matches the temperature of the system.

5 Apply a small amount of Glyptol to all potentiometers that were adjusted.

70 TCU Model 2080 Operation and Maintenance (Revision B)

Page 85: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

5.3Testing the Resistivity PCB

The following procedure is a manual test for checking the operation and function of the resistivity PCB and for calibrating the over−temperature probe. See Figure 5.3–1 for the locations of the potentiometers that you need to adjust.

Reference Documentation

Equipment Required

• Digital voltmeter

• Resistivity calibration tool, 685−110925−001

• Small, standard screwdriver

Materials

• Glyptal™

Document number Revision Description

856-097477-001 A KIT, 2080 RESISTIVITY UPGRADE

202-097479-001 A PROC, RES UPGRADE, 2080 TCU

202-098854-001 A PROC, RES SET POINT, 2080 TCU

71

Page 86: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SafetyTesting the Resistivity PCB

Safety

Type 3 task involved.

Procedure

The channels have been factory calibrated to trigger a low resistivity signal at 1 megohm centimeters. If adjustment is needed, use the following:

To test the resistivity PCB,

1 Connect the resistivity calibration tool to header U_ J1 on resistivity board (see Figure 5.3–1).

2 Power on the TCU. Allow the TCU to warm up for five minutes.

3 Set the calibration tool to the position marked 0 megohm centimeters. Select the upper channel from the front panel. Adjust potentiometer AR8 until the resistivity display reads 0.0 megohm centimeters.

4 Set the calibration tool to the position marked 1 megohm centimeters. Adjust potentiometer AR22 until the resistivity display reads 1.0 megohm centimeters.

5 Connect the positive lead of the voltmeter to test pin ATP2 and the negative lead to left side of resistor AR5. Adjust potentiometer AR3 until the voltmeter reads 0.000 (±0.005) VDC. There is an audible clicking from the electro−mechanical relay at the threshold. This adjustment sets the resistivity level, sending a low resistivity error to the tool.

6 Set the calibration tool to the position marked 0 megohm centimeters. Adjust potentiometer AR8 until the resistivity display reads −0.4 megohm centimeters. This calibrates the

WarningElectrical Hazard: Power is applied to the control PCB during calibration. Accidental contact with components operating at less than 30 VDC is possible. Avoid contact with components unless adjusting potentiometers.

ELECTRICAL

72 TCU Model 2080 Operation and Maintenance (Revision B)

Page 87: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureTesting the Resistivity PCB

resistivity board to the family of Thornton resistivity/conductivity meters (industry standard).

7 After completing the adjustment, the front panel display reads−0.4 megohm centimeters when the calibration tool is set at 0 megohm centimeters and 7.6 megohm centimeters when the calibration tool is set at 8 megohm centimeters.

8 Connect the calibration tool to header L_ J1 on the resistivity board.

9 Set the calibration tool to the position marked 0 megohm centimeters. Select the lower channel from the front panel. Adjust potentiometer BR8 until the resistivity display reads 0.0 megohm centimeters.

10 Set the calibration tool to the position marked 1 megohm centimeters. Adjust potentiometer BR22 until the resistivity display reads 1.0 megohm centimeters.

11 Connect the positive lead of the voltmeter to test pin BTP2 and the negative lead to the left side of resistor BR5. Adjust potentiometer BR3 until the voltmeter reads 0.000±0.005 VDC. There is an audible clicking from the electro−mechanical relay at the threshold. This adjustment sets the resistivity level, sending a low resistivity error to the tool.

12 Set the calibration tool to the position marked 0 megohm centimeters. Adjust potentiometer BR8 until the resistivity display reads −0.4 megohm centimeters. This calibrates the resistivity board to the family of Thornton resistivity/conductivity meters (industry standard).

13 Connect the positive lead of the voltmeter to test pin ATP9 and the negative lead to test pin GND1. Measure and note the voltage on ATP9. The voltage varies greatly depending on the temperature of the coolant.

14 Connect the positive lead of the voltmeter to test pin ATP14. Adjust potentiometer AR26 until the voltage on ATP14 is exactly 10 times greater than that of ATP9.

15 Connect the positive lead of the voltmeter to test pin BTP9 and the negative lead to test pin GND 2. Measure and note the voltage on BTP9.

TCU Model 2080 Operation and Maintenance (Revision B) 73

Page 88: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureTesting the Resistivity PCB

16 Connect the positive lead of the voltmeter to test pin BTP14. Adjust potentiometer BR26 until the voltage on BTP14 is exactly 10 times greater than that of BTP14.

17 Apply a small amount of Glyptol to all potentiometers that were adjusted.

18 Remove all test leads.

74 TCU Model 2080 Operation and Maintenance (Revision B)

Page 89: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureTesting the Resistivity PCB

Figure 5.3–1. TCU Resistivity PCB

BR

18

BR

3

BR

1

BR

2

BT

P2

BT

P3

BC

5B

C4 BR

13

L_J3

BC

R1

BR

3B

R7

BR

5

BR

12

BR

14

BR

6B

R9

BR

15

BR

16

BR

20

BR

19B

TP

8

BC

7

BR

11

BR

17

BC

10B

C11

BC

12

BC

20A

C20

BC

13

BR

28

BT

P1

BT

P15

BT

P13

BT

P11

BT

P10

BT

P7

BR

30

BR

43

BT

P20

BR

32

BR

39

BC

19

BR

22B

R21

BR

24

BR

29L_

J1B

C15

BC

3B

U2

BC

18

BT

P16

BR

31

BR

33

C6

BC

R2

BC

R3

BR

4

C3

C4

GN

D2

AT

P20

GN

D4

BT

P6

BU

3

BU

8B

C29

BC

28B

U7

BC

27B

C26

BU

6B

C25B

R46

BC

24

BR

44

BR

46

BR

47

BT

P19J2

L1

L2

C2

C1

TP

18T

P1

BK

1

BQ

1

BC14

TP3

TP2

BC2 BC3

BTP5

BC9

BR26

BU5 BC22

BC21BU4

AC

5

AC

4

AR

13

MADE IN USA

1996

U_J

3A

R8

AR

5

AR

9A

R6

AR

12A

R14

AR

15

AT

P13

AT

P8 A

TP

14

AT

P11

AR

30

AR

43

AT

P10

AT

P7

AT

P3

AR

32

AR

39

AC

19

AR

44

AR

22A

R21

AR

24

AR

29

U_J

1

AC15

AC

3

AU2

AC

18

AC

26A

U6

AC

25

AR

46A

R47

AT

P5

ATP4

AC6ATP15A

C9

AR26

AC21

AU4

AU5

AC22

BTP4

BTP9BTP12

BC1

AR

3 AR

4

AR

1

AR

2

AT

P2

AQ

1

AC

R1

AC7

AU1

AC

R2

AR

7

AR

11A

CR

3

AT

P1

CHILLER RESISTIVITY

810-025369-

S/H

DATE

REV

AC2 AC3AC1

BC6

BR34

BC23

BTP17

BC16

BR

20

BR

23

BR

38

BR

35

BR

36

BR

37

BC

17

BR

40

BR

42

BR

48

BT

P18

BR

25

BR

27

AR

18A

C10

AC

11A

C12

AC

13

AR

28

AR

19

AR

16

GN

D3

AT

P6

GN

D1 AU

3

AC14

ATP9ATP12

AR34

AC23A

TP

17

AC

16C

5

AR

20

AR

23

AR

38

AR

35

AR

36

AR

37

AC

17

AR

40

ATP18

AR

25

AR

27

BR

45

BR

49

BC

31

BC

30A

U8

AC

29A

C28

AU

7A

C27

AC

24

AR

44

AR

31

AR

33

ATP18

AR

42

AR

48

AR

45 AR

49

AC

31

AC

30

C

RESEARCH Lam

TU01C018Resistivity PCB

���

����

���

����

���

�����

����

����

�����

���

����

����

���

����

���

����

����

����

����

����

�������7

TCU Model 2080 Operation and Maintenance (Revision B) 75

Page 90: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

ProcedureTesting the Resistivity PCB

76 TCU Model 2080 Operation and Maintenance (Revision B)

Page 91: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

5.4Resistivity Alarm Range Upgrade

The 2080 TCU (851-110195-001 & -010) has a coolant low resistivity alarm which can only be set to actuate at 1 megohm centimeters. With the installation of the new Resistivity Upgrade Kit (856-097477-001), the range of the low resistivity alarm trigger will include settings of 1, 3, or 8 megohm centimeters. This kit also increases the range of resistivity displayed from [0 - 8 megohm centimeters] to [0 - 80 megohm centimeters].

The upgrade kit contains a new version PCB, new temperature probes, a calibration tool, and the procedure for performing the upgrade.

There is also a new calibration procedure (202-097479-001) for setting the low resistivity alarm trigger on the 2080 TCUs. This calibration procedure applies to all 851-110195-001 and -010 TCUs which have had the upgrade as well as all 851-110195-020 TCUs.

Reference Documentation

2080 TCU Resistivity Upgrade procedure 202-097479-001

Safety

Type 2 task involved.

Equipment Required

• Resistivity Upgrade Kit 856-097477-001

75

Page 92: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Equipment RequiredResistivity Alarm Range Upgrade

76 TCU Model 2080 Operation and Maintenance (Revision B)

Page 93: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

6Troubleshooting

The 2080 TCU is a dual channel, wide range (−20 to +80 degrees Celsius) system. It incorporates a closed loop design with no back pressure, and features continuous deionization of the coolant (Ethylene glycol/deionized water). Coolant is pumped from the TCU to the system and is circulated through the seal plates of the reaction chamber to maintain the desired system temperature. The coolant flow is approximately four gallons minimum per minute, at a delivery pressure up to 75 psi.

When troubleshooting the TCU (unplugging connectors, adjusting potentiometers, shutting off valves, and so forth) and the problem is not resolved, it is imperative to return the TCU to its original state before making further adjustments. It is equally important to follow the steps in this guide in a sequential order. Failure to do so may complicate the problem and compromise personal safety.

Schematics

On the following pages two schematics are given to be used for reference when troubleshooting the TCU. The first is the top level interconnect diagram (see Figure 6–1). The second is the electronic enclosure schematic (see Figure 6–2 and Figure 6–3). These drawings also include reference designators and part numbers for related Lam assemblies and schematics.

WarningPhysical Hazard: Voltages from circuitry within the electronic enclosure can cause severe injury or death. Contact with 208 VAC (3 Ø) and 28 VAC circuitry is possible in the rear half of the electronic enclosure. Avoid any physical contact or tools placed within the rear half of the AC box. In addition, DC voltages ranging from 5 to 15 are present. Only trained, qualified personnel should perform any maintenance in this unit.

ELECTRICAL

77

Page 94: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SchematicsTroubleshooting

Figure 6–1. Interconnect Diagram-210-110197-001

B10

M1

GN

D

CO

MP

RE

SS

OR

LS2

LR3

CL1

J5J6

P1/

P3

E8

FA

NC

RA

NK

CA

SE

HT

R

(REF 210-110198-020

E7

E6

A3

A1

B9

B4

B3

B2

B1

J7J1J2J3J4

853-

1104

28-0

20

SS

R

HE

/DI

TA

NK

HT

R

HG

BP

PU

MP

MO

TO

R

CO

ND

EN

SE

R

P2/

P4

853-

1101

29-0

01A

ND

-00

2

(RE

F 2

10-1

1019

8-00

1)

J10

J8J1

1J9

J12

FLO

WS

WIT

CH

LEV

EL

IND

ICA

TO

RO

VE

RT

EM

PP

RO

BE

RE

SIS

PR

OB

ET

EM

PP

RO

BE

NO

TE

S:

-001

US

ES

P1

AN

D P

2 (U

PP

ER

CH

AN

NE

L)

-002

US

ES

P3

AN

D P

4 (L

OW

ER

CH

AN

NE

L)

853-

1104

30-0

20

A6

A9

M2

LIN

EH

I/LO

PR

ES

UR

ES

WIT

CH

GN

D

LIN

E

B5

TB

1

B7

B6

B8

TU

00C

010

78 TCU Model 2080 Operation and Maintenance (Revision B)

Page 95: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SchematicsTroubleshooting

Figure 6–2. Electronic Enclosure Schematic-210-110198-001 Sheet 1

AC

PO

WE

RC

B1

K1

A2

A3

A4

A6

A7

A8

A10

A11

A12

K2

MA

INT

B

T1

T1-

1T

1-2

T1-

4T

1-6

A78 A77

T1-

11T

1-10

T1-

9T

1-8

T1-

12

T1-

7

TO

4P

3 (R

EF

)S

HE

ET

2 C

/B, 3

TO

4P

3 (R

EF

)S

HE

ET

2 C

/B, 3

LIN

E F

US

E

853-

1103

20-0

20

LIN

EF

US

E

853-

1103

74-0

01

853-

1103

75-0

01

853-

1103

60-0

01

TO

4P

7 (R

EF

)S

HE

ET

2 B

/C,3

K1A

2

K1A

1

K1A

2

TO

4P

7 (R

EF

)S

HE

ET

2 B

/C,3

A14

A15

A16

853-

1103

62-0

01

A21

A20

A19

A25

A26

A27

A28

A29

A30

A31

A32

A33

A34

A35

A36

DC

PO

WE

RS

UP

PLY

853-

1103

43-0

20

1J1

SS

R2-

L

SS

R1-

U

1J3

PS

1

TO

TB

2 (R

EF

)S

HE

ET

2 E

,5

A45

A46

A43

A44

853-

1103

16-0

20

TO

3P

9U (

RE

F)

SH

EE

T 2

E,4

853-

1103

45-0

20

853-

1103

45-0

20

TO

4P

7 (R

EF

)S

HE

ET

2 B

/C,3

853-

1103

45-0

20

TO

4P

7 (R

EF

)S

HE

ET

2 B

/C,3

853-

1103

45-0

20

A55

A38

A37

A42

A61

A62

A59

A60

TB

1

A39

A40

A41

A56

A57

A58

A51

A52

A54

A67

A68

A53

A66

A65

CB

2A

50A

49

A63

A64

A47

A48

A69

A70

A76

A75

A74

A73

CB

3

CB

4

CB

5

CB

6

4P7

4P8

RE

LAY

BO

AR

D

4P3

4P6

4P4

4P2

4P1

(RE

F)

SH

EE

T 2

B/C

,3

853-

1102

10-0

20

4P5

853-

1103

63-0

01

A72

A71

A24

A23

A22

K2A

1

TU

00C

011

TCU Model 2080 Operation and Maintenance (Revision B) 79

Page 96: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

SchematicsTroubleshooting

Figure 6–3. Electronic Enclosure Schematic-210-110198-001 Sheet 2

7B5B3B

1A 2A

1J2

853-

1103

43-0

01 DC

PO

WE

RS

UP

PLY

DS

3D

S3

2D

S3

1

DS

2 2

TB

2

6A

DS

2

8A

DS

1

7A

DS

2 1

3A

DS

1 2

5A

DS

1 1

4A

RE

SIS

TIV

ITY

BO

AR

D2P

1L

2P2

2P1U

1J4

PS

1(R

EF

) S

HE

ET

1 E

,3

853-

1104

24-0

01

1B

RE

F D

WG

210

-110

198-

001

DIS

PLA

Y

DT

1

DT

2

DIS

PLA

Y

TE

MP

.

RE

SIS

DR

2

DR

1

IT5

N.O

.IN

TLK

SW

ITC

H

HO

UR

ME

TE

R

HM

5

HM

6

IT5

CO

M

1J5

853-

1103

21-0

01

SS

R2-

L

SS

R1-

UA

45A

46 A43

A44

RE

AR

UP

PE

RF

ILL

LED

RE

LAY

BO

AR

D

4P1

4P2

4P3

4P4

4P6

4P7

4P8

B2

A2

Rea

rE

MO

B1

A1

1J99

3P1L

CO

NT

RO

LB

OA

RD

3P4L

3P1U

3P8

3P4U 85

3-11

0343

-001

(RE

F)

SH

EE

T 1

A/B

,2

TO

K1

AN

D K

2(R

EF

) S

HE

ET

1 D

,5A

ND

C,5

853-

1103

59-0

01

4P5

853-

1103

43-0

01(R

EF

) S

HE

ET

1 D

,2

853-

1102

10-0

01

3P3

3P9L

3P9U

3P7 85

3-11

0344

-001

72J1

72J2

S4B

1S

4A2

S2

1

FR

ON

T

S2

S1

A

S1

3S

1 B

S1

4

S2

1

S1

S4B

2E

MO

S2

2

853-

1103

16-0

01

853-

1103

19-0

01

853-

1103

17-0

01

853-

1103

18-0

01

853-

1103

61-0

01

853-

1103

46-0

01

S4A

1

853-

1103

20-0

01

853-

1103

45-0

01

PA

RT

OF

FR

ON

T P

AN

EL

2P3U

3P2

TO T1-7 AND T1-12(REF) SHEET 1 B,5

RE

AR

UP

PE

RF

ILL

LED

2P3L

3P5

TU

00C

012

Inte

rfac

e

EM

O

80 TCU Model 2080 Operation and Maintenance (Revision B)

Page 97: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic Troubleshooting Using the Controller PCBTroubleshooting

Basic Troubleshooting Using the Controller PCB

You can use certain connectors on the controller PCB for basic troubleshooting. These connectors have reference designators with a “U” or an “L” suffix. Since both channels on the TCU contain a great deal of identical circuitry, the suffix is used to distinguish between the upper and the lower channels. The following steps provide some basic troubleshooting techniques that you can perform using the controller PCB connectors.

To use the controller PCB for troubleshooting,

1 If the red Comp, Flow, Level, Heat, or Resis indicators for the lower channel (front panel) do not clear, try swapping 3P4U with 3P4L. If the indicators on the upper channel fail to clear, the problem is not with the PCB, but with the wiring harness or the sensor.

Note Ensure that relocated plugs are properly seated on all pins of the connector. It is possible for a plug to be 1 or 2 pins out of alignment and still appear to be properly seated.

2 If the TCU needs to be placed in maximum cooling mode, set the local setpoint to −30 degrees Celsius.

3 Jumper 72J2 (pins 5 and 6) or turn tool off, placing TCU into local mode.

Basic Troubleshooting

The following troubleshooting guide is to better assist the technician in finding any anomaly within the system. It describes the circuitry involved, the possible cause of a particular problem, and the corrective action steps to alleviate the problem.

CautionPhysical Hazard: The TCU, in maximum cooling mode, may reach temperatures to -25 degrees Celsius depending upon the installation and the distance from the system. Avoid direct contact with refrigeration lines and components.

GENERAL ALERT

TCU Model 2080 Operation and Maintenance (Revision B) 81

Page 98: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

Status Indicators

Located on the front control panel of the TCU are two separate rows of status indicators, one row for the upper channel and one for the lower channel. Status indicators appear green when the system is operating normally and red when an alarm condition exists. A red illuminated LED on the control panel indicates the following:

Table 6–1. Status Indicators

Comp The refrigerant pressure safety cut out has shut the TCU down.

Htr The reservoir temperature has exceeded the safe limit and the TCU has shut down.

Flow There is no flow returning from the electrode, the TCU has shut down. (Upper and lower indicators turn red when the TCU is shut down.)

Level The coolant level in the reservoir is dangerously low, and the TCU has shut down.

Fill The coolant level in the reservoir is low.

Resis The resistivity of the tank mixture is low.

WarningEquipment Hazard: The refrigeration units within the TCU are hermetically sealed and are not user serviceable. Only trained and licensed personnel should work on this equipment.

GENERAL ALERT

82 TCU Model 2080 Operation and Maintenance (Revision B)

Page 99: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

Table 6–2. Troubleshooting Guide

Problem Corrective Action Possible Causes Circuit Description

AC and fail lights are the only lights illuminated. TCU will not start.

Unlock the EMO button. Reset the status indicators and restart the TCU.

EMO circuit activated. The EMO circuit is a loop that travels through the TCU, the RF cart and the system. The TCU is also equipped with 6 safety interlocks (one on each of the covers). Removing any of these covers, while the TCU is running, shuts off the system.

Be sure the six covers are in place and pushing in the safety interlocks.

Interlock switch activated.

Check fuses in enclosure. Blown fuse.

Verify proper output voltage in enclosure.

Faulty transformer or power supply.

Verify the EMO circuit from the system, the TCU, and all remote equipment is continuous. Check the connector in the back of the TCU (72J2).

EMO signal cable is not a continuous circuit.

COMP status indicator appears red. TCU has shutdown. Low pressure cut out.

Wait five minutes to allow the pressure switch to reset. Depress the COMP status indicator to clear the alarm. If the indicator appears green, a low pressure cut out is indicated. Restart the system. If the indicator does not clear, proceed to the “High Pressure Cut Out” section of Table 6–2. If a low pressure alarm occurs again, perform the following:

Low pressure cut out activated. Low pressure is automatically reset. High pressure cut out must be manually reset.

The low pressure cut out switch is activated when the suction pressure falls below the factory setting indicated on the label. After the TCU had been shut off and the refrigerant pressure has been equalized, the switch automatically resets and you can clear the alarm on the TCU panel.

TCU Model 2080 Operation and Maintenance (Revision B) 83

Page 100: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

COMP status indicator is illuminated red. TCU shutdown. Low pressure cut out.(cont.)

Be sure the low pressure cut out switch is set as indicated on the label.

Low pressure cut out setting is too high.

The low pressure cut out and cut in pressures are factory adjusted. They can be accurately set only by the refrigerant pressure gauges monitoring the system.

If operating at temperatures below 0 degrees Celsius, check the specific gravity of the coolant using a hydrometer. The reading should be approximately 1.065±0.005 at 20 degrees Celsius.

Incorrect coolant mixture.

The DI water and Ethylene Glycol mixture must be exactly 50/50 for proper TCU operation. This provides proper lubrication of the pump, and protects the system from unexpected freezing damage. If setpoints near or below freezing are being used and the mix contains too much water, ice begins to form on the evaporator coil in the reservoir. This causes the thermostatic expansion valve to restrict and the compressor to cut out from low pressure.

With the channel in the cooling mode, check the sight glass for refrigerant flow. Check the baseplate, valves, and fittings for oil. If the sight glass is low or a leak is suspected, call a refrigeration service technician.

Low refrigerant charge. In the cooling mode, a turbulent flow of liquid and vapor are visible in the sight glass. If there is little or no liquid, the unit is low on refrigerant. This may indicate a refrigerant leak. You can perform further leak checking with a halogen detector.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

84 TCU Model 2080 Operation and Maintenance (Revision B)

Page 101: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

COMP status indicator appears red. TCU has shutdown. High pressure cut out.

Check the facilities water flow to the TCU (4 to 8 GPM and < 25 degrees Celsius). Be sure the supply and return facility lines are connected at the TCU. Push in the reset switch firmly to overcome the spring pressure and clear COMP status indicator.

Insufficient supply or improperly connected water lines.

A high−pressure cut out may be caused by an improper facilities water supply. The high−pressure cut out switches are located on the right side of the TCU. They will cut out the compressor if the refrigerant pressure exceeds the safety setting. Holes in the side cover allow access to the reset bar.

With the TCU in the cooling cycle, feel the condenser water valve and the outlet fitting from the condenser. They should be cold. If the outlet of the condenser is warm, it may indicate that the valve is not operating properly.

Defective condenser water valve.

The water valve is normally open, and remains open during the cooling cycle. It is energized (closed) only during the heat cycle. If it is not opening, the channel will cut out due to high pressure anytime it tries to cool.

With the channel in the cooling mode, look in the sight glass, to verify proper refrigerant flow. If the sight glass fills with liquid refrigerant, it may indicate an overcharge. Call a refrigeration service technician.

Refrigerant in channel is overcharged.

A high−pressure cut out can occur due to a refrigerant overcharge. This may be likely if the TCU has recently been recharged. The label on the compressor contains the charge weight. A precision scale should be used when charging.

Unplug J3, and remove the coil from the heat exchanger solenoid valve. Install it on the hot gas bypass valve using the J2 connector. If the valve opens, replace the coil. (Caution: Remove the coil from the valve only when it is unplugged. Energizing a solenoid coil when it is not snapped over a valve stem overheats the windings.)

Faulty solenoid coil. A defective hot gas bypass valve may cause a high−pressure cut out when the unit cycles to the heat mode. When placed in the heat mode, this valve should open with an audible click. You can hear the gas rushing through the tubing into the evaporator. The sight glass will empty, and the tubing and valve get very hot from gas flow.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

TCU Model 2080 Operation and Maintenance (Revision B) 85

Page 102: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

COMP status indicator appears red. TCU has shutdown. High pressure cut out (continued)

With the channel in the heat mode, listen for the gas rushing through the hot gas bypass tubing. If there is no gas flowing through the tubing and the TCU cuts out instantly, the solenoid valve cannot open. Call a refrigeration service technician.

Hot gas bypass valve unable to open.

A defective hot gas bypass valve may cause a high pressure cut out when the TCU cycles to the heat mode. When placing the TCU in the heat mode, SV107 should turn on with an audible click, and you can hear the gas rushing through the tubing into the evaporator.

Be sure the control PCB operates properly. Replace if faulty. To check orientation of the PCB see Section 5.1, "Calibrating the Temperature Probe."

Faulty control PCB.

HTR status indicator is illuminated red. TCU has shutdown.

Verify the setpoint from the system.

Improper setpoint from the system. Overheat protection is activated.

There is a separate temperature probe located in the top of each reservoir. The probe sends the reservoir temperature signal to the resistivity PCB. If the tank exceeds 94 degrees Celsius, it will cause an overheat shutdown of the TCU.

Verify the reservoir temperature. If the tank is overheating, see “TCU heats uncontrollably” section of Table 6–2.

Tank is overheated.

Verify tank temperature probe output. Bring the affected channel to 80 degrees Celsius. Use a DVM to measure voltage at test point ATP23 (upper) or BTP23 (lower) on resistivity PCB. If output is above 368 mV, replace the faulty probe.

Faulty tank temperature probe.

Check the wiring from the probe, through the connectors to the resistivity PCB.

Bad contact or faulty wiring from tank probe to PCB.

Be sure the resistivity and control PCBs are operating properly.

Faulty resistivity or control PCBs.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

86 TCU Model 2080 Operation and Maintenance (Revision B)

Page 103: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

FLOW indicator appears red. Note: Both FLOW status indicators are normally red when the TCU is off or has shut down from other failures.

Clear the status indicators and start TCU. The first flow LED to turn red is the affected channel. Remove the return line from the back of this channel. While holding it in a proper container, start the TCU. If there is no flow, continue with the following. If the flow is acceptable proceed to step f.

No flow. The 2080 TCU is equipped with a magnetically coupled gear pump. This pump requires an exact 50/50 mix for lubrication and proper operation. The pump circulates the mix past a bypass valve, over the temperature probe, to the system and back through a flow sensor into the tank. The flow sensors have a 10 second delay. This allows time to reset and start the machine. The flow sensor switches open when less than 1 gpm returns to the TCU.

Note: When one channel fails from poor flow, the TCU shuts down and the FLOW indicators for both channels illuminate red.) For testing purposes, press and hold the ON button. When released, the TCU stops.

Note: The TCU is wired in a way that causes one of the pumps to not operate correctly if one of the power phases is missing.

a. Be sure lines to the tool were purged.

Air in the lines to and from the system.

b. Be sure the coolant lines are not blocked and valves on the system are open.

Coolant lines are blocked or valves are closed.

c. Verify CB2 and CB4 are in the On position and functioning.

CB2 or CB4 are defective or off.

d. Be sure there is 3−phase power to TCU.

TCU is receiving only two phases of power.

e. Be sure mixture ratio is 1.065 specific gravity.

Coolant mixture is off, causing the drive magnet to decouple.

f. Replace motor/pump. Defective motor/pump.

g. After verifying good return flow, be sure the flow switch is functioning. Replace it if needed.

Faulty flow switch.

h. Check the wiring from P10 connector at the flow switch, through the harness, to the control board.

Defective connector or wiring.

i. Be sure the resistivity and the control PCBs are functioning.

Faulty resistivity or control PCB.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

TCU Model 2080 Operation and Maintenance (Revision B) 87

Page 104: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

LEVEL status indicator is red.

a. Fill TCU coolant tank to proper level and restart. Check lines and fittings for leaks. (See Section 4.2, "Filling the Reservoir.")

Coolant level sensor is activated.

The level sensor indicates the level of the coolant in the tank. The normal operation of this sensor as the tank level drops is: a) the FILL status indicator turns red b) the LEVEL status indicator turns red c) the TCU shuts down.

b.Verify the integrity of the wiring from the P8 connector, through the harness to the control board.

Defective connector or wiring.

P8 is the connector to the level sensor. The wiring goes through the resistivity PCB and onto the main PCB.

c. Remove and inspect the level sensor. Replace if defective.

Defective level sensor. If the tank is topped off and the red LEVEL warning will not clear, it may be a faulty level sensor.

d. Verify the operation of the main PCB. Replace if defective.

Faulty control PCB.

FILL status indicator appears red.

a. Add coolant to the tank, and verify that there are no leaks. Reset the status indicators.

Coolant is low. See Section 4.2, "Filling the Reservoir." If the tank is topped off and the red FILL warning does not clear, it may be a faulty level sensor.

b. Remove and inspect the level sensor. Replace if necessary.

Defective level sensor.

c. Check the main control PCB. Replace if necessary.

Faulty control PCB.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

88 TCU Model 2080 Operation and Maintenance (Revision B)

Page 105: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

RESIS indicator appears red.

a. Run TCU to allow the coolant to regain proper resistivity. (This may take up to 12 hours.)

Coolant has not been scrubbed due to TCU standing idle.

The deionizing loop starts at the coolant line near the temperature probe. It enters a capillary tube at a swagelok fitting and the flows through a heat exchanger. It exits into a 1/4−inch tube and travels through both polishing cartridges and returns to the reservoir. The flow can be checked by removing a cartridge housing and starting the TCU. After a few seconds, the mixture should trickle out in a small stream.

b. Verify proper flow through the deionizing loop. Be sure that the cartridges are not upside down.

Flow of the deionized loop is blocked.

c. Replace coolant and cartridges.

Bad coolant or cartridge: the coolant mixture maybe off, resistivity does not improve.

d. Check the resistivity and control PCBs. Replace if necessary.

Faulty resistivity or control PCB.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

TCU Model 2080 Operation and Maintenance (Revision B) 89

Page 106: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

TCU will not heat properly.

a. Verify the setpoint from the system.

Improper setpoint.

b. Place the TCU channel into the cool mode. Look for a turbulent flow of refrigerant in the sight glass. If refrigerant is low or a leak is suspected contact a refrigeration service technician.

Low refrigerant. When the channel is in the cooling mode, a rushing turbulent flow seen in the sight glass means the refrigerant is fully charged.

c. Verify 208 VAC across the contacts at J4. If there is power, and the heater is not activated, replace the immersion heater.

Faulty immersion heater.

When the setpoint is above the tank temperature, the control board sends a 5 VDC signal to the solid state relay. This in turn sends 208 VAC to the channel which opens the hot gas bypass valve, activates the immersion heater, and closes the condenser water valve.

d. Check the condenser water valve. Replace if necessary.

Condenser water valve will not close.

e. Check 3−phase power to TCU. With TCU on, verify power from J14 to compressor. If there is power to the compressor and the problem persists, contact a refrigeration service technician.

Compressor problem. The compressor is a 3−phase hermetically sealed non−serviceable unit. It also has an internal thermal cut out that shuts it down if it gets too hot.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

90 TCU Model 2080 Operation and Maintenance (Revision B)

Page 107: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

TCU will not cool down.

a. Verify the proper setpoint from the system to the TCU.

Improper setpoint. When the channel is in the cooling mode, a rushing turbulent flow seen in the sight glass means the refrigerant is fully charged. The hot gas bypass line is cool to the touch. The immersion heater is off, and the condenser water valve is open.

b. Check the flow direction, the temperature, and the flow rate of the facilities water.

Insufficient cooling water.

c. Check the coolant mixture. Improper coolant mixture.

d. Place the channel in the cooling mode. Look for a turbulent flow of refrigerant in the sight glass. If the refrigerant is low or a leak is suspected, contact a refrigerant service technician.

Low refrigerant level.

e. Check the bypass valve. If the solenoid valve is not energized or closed, and the hot gas line into the tank is hot, contact a refrigeration service technician.

Hot bypass valve unable to close.

f. Verify proper 3−phase power to TCU. With TCU on verify power from J14 to compressor. If there is power to the compressor and the problem persists, contact a refrigeration service technician.

Compressor problem.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

TCU Model 2080 Operation and Maintenance (Revision B) 91

Page 108: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

TCU heats uncontrollably.

Verify proper setpoint from the system to the TCU.

Improper setpoint. When the TCU (both channels) cycles to the heat mode, the main PCB sends a 5 VDC signal to the SSR (upper and lower). A 208 VAC is sent to the channel. The condenser water valve closes, the hot gas bypass valve opens, and the immersion heater activates. The piping from the hot gas bypass line to the tank becomes very hot and you can hear the gas entering the evaporator coil.

Ensure that all power plugs in the enclosure are connected, and that the upper and lower connectors are not reversed.

Connectors improperly inserted.

Check temperature probe, see Section 5.1, "Calibrating the Temperature Probe."

Faulty temperature probe.

With the channel in the cooling mode, unplug the hot gas bypass valve. The valve should be cool to the touch. If it is warm, and gas is still passing though it contact a refrigeration service technician.

Hot gas bypass valve unable to close.

Check the control PCB. Replace if necessary.

Faulty control PCB.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

92 TCU Model 2080 Operation and Maintenance (Revision B)

Page 109: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

TCU cools uncontrollably.

Verify the proper setpoint into TCU.

Improper setpoint from the system.

The setpoint voltage enters the TCU through the 37−pin connector as a DC voltage signal. 1 volt equals 10 degrees Celsius. (Example: 2.50 volts equals 25.0 degrees Celsius) If the 37−pin connector loses contact or if no DC signal is received, the TCU will cool to 0 degrees Celsius. The lower channel setpoint signal is pin 24 and the upper channel setpoint signal is pin 25. The signal travels to the PCB, and is compared to the TCU temperature probe. If the channel needs to warm, a 5 VDC signal is sent to the SSR. This activates the hot gas bypass valve, immersion heater, and water valve. If the channel needs to cool, no signal is sent. The AC power that activates the heater is sent from the SSR to the circuit breaker at the back of the enclosure, then it goes through the connectors and the terminal blocks to the components. Any interruption between the SSR and the channel will cause this problem.

Verify setpoint on TCU front panel display. If the setpoint does not agree with the system, check setpoint voltage at the 72J1 connector.

No setpoint voltage into TCU.

Check solid state relay. Replace if necessary.

Faulty solid state relay.

Check CB3 (lower) and CB5 (upper). They control the AC power that activates the heating circuit.

Faulty 10 amp breaker.

Check the connectors. Look for backed out pins, arcing, loose contacts, and so forth.

AC voltage is not going through the connector to the channel.

Ensure that all power plugs in the enclosure are connected, and that the upper and lower connectors are not reversed.

Connectors improperly inserted.

Check temperature probe. Compare the channel display to the actual coolant temperature. Replace probe if necessary, see Section 5.1, "Calibrating the Temperature Probe."

Faulty temperature probe.

Check control PCB. Replace if necessary.

Faulty control PCB.

Table 6–2. Troubleshooting Guide (continued)

Problem Corrective Action Possible Causes Circuit Description

TCU Model 2080 Operation and Maintenance (Revision B) 93

Page 110: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Basic TroubleshootingTroubleshooting

94 TCU Model 2080 Operation and Maintenance (Revision B)

Page 111: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Appendix AReference Documentation

Table A–1. Reference Drawings

Drawing number Revision Name

853-025245-202 A Assembly, Temperature Probe, Insul Tank

853-025245-203 A Assembly, Temperature Probe, Insul, Inln

810-025369-003 D Assembly, PCB, Chiller, Resistivity

810-025370-004 C Assembly, PCB Chiller Control

775-091420-001 1 Cartridge, DI Polishing

718-098540-001 A Flow Switch Mod.

800-110195-120 A Assembly, 2080 TCU CE97

851-110195-120 A Assembly, Top 2080 TCU CE97

210-110198-020 F Schematic, Electronic Box, 2080 CE97

800-110198-020 C Assembly Electronic Box, 2080 CE97

853-110566-001 A Assembly, Ind, Flt Sens, 2080 TCU

676-110636-003 B Pump, Motor Fan Cooled, Motified Inlet Port

210-110747-001 E Schematic, Refrigeration Unit Stainless 2080

800-110747-120 A Assembly, Channel, Stainless, 2080, CE97

852-110747-120 A Assembly, Channel, Stainless, Upper, 2080

852-110747-121 A Assembly, Channel, Stainless, Lower, 2080

800-110748-120 A Assembly, Refrigeration, Stainless, 2080

853-110748-XXX E Assembly, Refrigeration, Stainless, Upper, 2080

853-110748-121 B Assembly, Refrigeration, Stainless, Lower, 2080

853-110877-001 C Assembly, 2080, Resistivity Probe, K= .01

853-110997-003 A Assembly, Valve, Solenoid, 2-Way, Normally Open

95

Page 112: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Reference Documentation

96 TCU Model 2080 Operation and Maintenance (Revision B)

Page 113: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Index

CCalibrating

temperature probe 65Controller PCB (printed circuit board) 68Coolant 12

polishing filter cartridge 59Coolant Flow 10

DDrawings 95

EElectronic Enclosure

schematic 79emissions, air 3EMO (emergency off) 19

FFacility Requirements 23

deionized water 24electrical receptacle 24ethylene glycol 24floor mounts 25floor space 23water supply 23

Facility Water Flow 12Fail Indicators 37Front Control Panel 13Front Panel

channel control 14main controls 14main indicators 15

Hhigh/low temperature limits 36

IInstallation

standalone 29Interface Hardware 13Interlocks 19

OOperational Check 55

PPFC (perflurocarbons) 3Preventive Maintenance 41

monthly 41

RRear Panel 17

connectors 18controls 17electronic enclosure 17

Refrigerantcharging 47, 51connection points 53

Refrigerationassembly 11block diagram 9

Remote Temperature Offset 69Reservoir

fill ports 45filling 43

Resistivity Alarm Range 75Resistivity PCB (printed circuit board)

diagram 74testing 71

Resistivity Upgrade 75

SSafety

159

Page 114: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Index

emergency off 5enclosure interlocks 7energized electrical work types 5environmental regulations 3ergonomics 6HAPS (hazardous air pollutants)

regulations management 4hazardous waste 4lockout/tagout 5point-of-use abatement 3protective gear 6secondary containment 4shutdown 6training 3

Safety Circuits 20Start-Up

purge 34Start-up 34

160 TCU M

TTCU

operation 55refrigerant flow 8specifications 12

TCU (temperature control unit)description 7

Temperature Probes 65Troubleshooting 77

controller PCB (printed circuit board) 81Electronic Enclosure Schematic 79guide 83interconnect diagram 78status indicators 82

VVOC (volative organic compounds) 3

odel 2080 Operation and Maintenance (Revision B)

Page 115: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

For additional information,contact the closest Lam Research Corporation Office

To send e-mail,

For emergency assistance,Publications Department [email protected] Lam Tech Center (1) (510) 572-2020TSIC Support [email protected] Field Service (1) (800) LAM-HELPLam Tech Center [email protected] Customer Service (Parts) (1) (800) LAM-HELPVideo Department [email protected]

DOMESTIC OFFICES

CorporateCA Fremont (1) (510) 572-0200

Central RegionTX Austin (1) (512) 634-3100

TX Richardson (1) (972) 644-1717

MN Bloomington (1) (612) 858-7225

Eastern RegionMA Westborough (1) (508) 898-2090

NY Fishkill (1) (914) 896-0606

VT Williston (1) (802) 879-1153

FL Orlando (1) (407) 438-8448

VA Manassas (1) (703) 392-6403

ME South Portland (1) (207) 828-9462

Northwestern RegionID Boise (1) (208) 373-7400

OR Aloha (1) (503) 642-8671

WA Vancouver (1) (360) 260-9600

Southwestern RegionAZ Tempe (1) (480) 921-7373

CO Colorado Springs (1) (719) 577-4480

NM Albuquerque (1) (505) 857-0391

Western RegionCA Costa Mesa (1) (714) 641-1871

CA Fremont (1) (510) 572-5500

CA Milpitas (1) (510) 572-6109

JAPANESE OFFICES

Lam Research Co., Ltd.—HeadquartersKanagawa Sagamihara-shi (81) (427) 70-0320

Lam Research Co., Ltd.Kanagawa Sagamihara-shi (81) (427) 70-0321

Kanagawa Sagamihara-shi (81) (427) 70-0326

Ibaragi-ken Tsuchiura-shi (81) (298) 41-5930

Mie-ken Yokkaichi-shi (81) (593) 55-6170

Miyagi-ken Sendai-shi (81) (222) 18-2770

Hiroshima-ken Fukuyama-shi (81) (849) 28-9870

Toyama-ken Toyama-shi (81) (764) 44-2250

Osaka Osaka-shi (81) (6) 305-0052

EUROPEAN OFFICES

Lam Research SARLFrance Meyaln (33) (0) 476-614-900

France Le Coudray Montceaux

(33) (0) 164-93-7400

Lam Research GmbHGermany Munich (49) (0) 89-96099-0

Lam Research (Ireland) LimitedIreland Dublin (353) (1) 4579-186

Lam Research (Israel)Israel Natanya (972) (9) 8-659-085

Lam Research SRLItaly Agata Li-Battiati, CT (39) (95) 7254313

Italy Agrate Brianza-MI (39) (039) 657041

Italy Marsicana, AQ (39) (863) 412330

Lam Research BVThe

NetherlandsNijmegen (31) (24) 372-7110

Lam Research Ltd.Scotland East Kilbride (44) 13552-34430

Bristol Almondsbury (441) (454) 878-712

PACIFIC RIM OFFICES

Lam Research China PRC Beijing (86) (10) 6510-2990

Lam Research ShanghaiPRC Shanghai (86) (21) 3895-4540

Lam Research Korea LtdSungnam Kyungki-Do (82) (31) 710-6600

Lam TaiwanROC Hsin-chu (886) (35) 798666

ROC Hsin-chu (886) (35) 346123

Lam Singapore Pte, Ltd.Singapore (65) 347-6888

Page 116: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Lam Research Corporation HeadquartersFremont, California

Part Number: 406-240155-120

Page 117: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

For additional information,contact the closest Lam Research Corporation Office

To send e-mail,

For emergency assistance,Publications Department [email protected] Lam Tech Center (1) (510) 572-2020TSIC Support [email protected] Field Service (1) (800) LAM-HELPLam Tech Center [email protected] Customer Service (Parts) (1) (800) LAM-HELPVideo Department [email protected]

DOMESTIC OFFICES

CorporateCA Fremont (1) (510) 572-0200

Central RegionTX Austin (1) (512) 634-3100

TX Richardson (1) (972) 644-1717

MN Bloomington (1) (612) 858-7225

Eastern RegionMA Westborough (1) (508) 898-2090

NY Fishkill (1) (914) 896-0606

VT Williston (1) (802) 879-1153

FL Orlando (1) (407) 438-8448

VA Manassas (1) (703) 392-6403

ME South Portland (1) (207) 828-9462

Northwestern RegionID Boise (1) (208) 373-7400

OR Aloha (1) (503) 642-8671

WA Vancouver (1) (360) 260-9600

Southwestern RegionAZ Tempe (1) (480) 921-7373

CO Colorado Springs (1) (719) 577-4480

NM Albuquerque (1) (505) 857-0391

Western RegionCA Costa Mesa (1) (714) 641-1871

CA Fremont (1) (510) 572-5500

CA Milpitas (1) (510) 572-6109

JAPANESE OFFICES

Lam Research Co., Ltd.—HeadquartersKanagawa Sagamihara-shi (81) (427) 70-0320

Lam Research Co., Ltd.Kanagawa Sagamihara-shi (81) (427) 70-0321

Kanagawa Sagamihara-shi (81) (427) 70-0326

Ibaragi-ken Tsuchiura-shi (81) (298) 41-5930

Mie-ken Yokkaichi-shi (81) (593) 55-6170

Miyagi-ken Sendai-shi (81) (222) 18-2770

Hiroshima-ken Fukuyama-shi (81) (849) 28-9870

Toyama-ken Toyama-shi (81) (764) 44-2250

Osaka Osaka-shi (81) (6) 305-0052

EUROPEAN OFFICES

Lam Research SARLFrance Meyaln (33) (0) 476-614-900

France Le Coudray Montceaux

(33) (0) 164-93-7400

Lam Research GmbHGermany Munich (49) (0) 89-96099-0

Lam Research (Ireland) LimitedIreland Dublin (353) (1) 4579-186

Lam Research (Israel)Israel Natanya (972) (9) 8-659-085

Lam Research SRLItaly Agata Li-Battiati, CT (39) (95) 7254313

Italy Agrate Brianza-MI (39) (039) 657041

Italy Marsicana, AQ (39) (863) 412330

Lam Research BVThe

NetherlandsNijmegen (31) (24) 372-7110

Lam Research Ltd.Scotland East Kilbride (44) 13552-34430

Bristol Almondsbury (441) (454) 878-712

PACIFIC RIM OFFICES

Lam Research China PRC Beijing (86) (10) 6510-2990

Lam Research ShanghaiPRC Shanghai (86) (21) 3895-4540

Lam Research Korea LtdSungnam Kyungki-Do (82) (31) 710-6600

Lam TaiwanROC Hsin-chu (886) (35) 798666

ROC Hsin-chu (886) (35) 346123

Lam Singapore Pte, Ltd.Singapore (65) 347-6888

Page 118: TCU Model 2080 - Trilliumii TCU Model 2080 Operation and Maintenance (Revision B) EMO, Interlocks, and Safety Circuits 19 Emergency Off 19 Interlocks 19 Subsystem Safety Circuits 20

Lam Research Corporation HeadquartersFremont, California

Part Number: 409-240155-120