task academic computer center mścisław nakonieczny, [email protected] sławomir połomski,...
TRANSCRIPT
TASKTASKAcademic Computer Academic Computer Center Center
Mścisław Nakonieczny, [email protected]ławomir Połomski, [email protected]
7 VI 2004 - Gdańsk, Poland
Agenda
ACC TASK xWDM project at TASK
– CWDM– Passive optics: splitters, circulators– Economy of our solution– Future: 10GE, EPON
ACC TASK
Supercomputer Division– 256 Itanium processors based cluster– 128 Xeon cluster, SGI, SUN
Network Division– MAN in Gdańsk region– 140km of fiber optic cables – since
’93 to ’97 – ATM, GE backbone– 50 000 users
Map
140km of own fibers
ATM, GE
TASK’s backbone
AsyncSerial
TPGdy2
BibPAN
UG6
UG14
PRS
UG10
CTM
IMGW
ZIMW
WSM2
IPISD
IMr
ASP
AMG4
UG5
CTO1
IO
AMW
DSAM
AWF
IBW
UG1
IMP
UG4
AMG1
CI TASK
AMuzASP2
IES
MIR
ETI
AMG1
UG17
AMG9
9.6 kbps
SOIE
PG
AM
SZP
DS6UGAMG3
UG3
IMMT
BMTPIG
UG11
CI
AMor3
DS11UG
DS1UG
GWSH
ZSO
BGUG
I LO
AMG7
WSB
WSMSGiP
UG4
Port
WSF
PWR
AMG2
GSR
ZEIEN
Chop
DS11PG
EWŻ
CBM
UG8
DSAMuz
DSUG
Univ BaltVLO
IMr2
GSP
DSAMG AMG1
UG4ck
UG4por
UG6
TPGda
AMuzUG5
CTO1TPWrz
AMG3
ZE
UG1ck
UG10
DS8UG
DS7UG
AMG2DS1UG
IO
PWR
BTC
IMMT
PCK
UG3
AMW
WSM
TPGdy
WEJHEWZ
CI
GSP
WEJH
WSM
TPGdy
IO
UG3
UG2
UG1
CTMTASK
CI
PKP
EXTREME
ETI
AMG1
UG5
SOIE UG16
CTO1
TPWrz
AMG3
DS11UG
AMG2
CI
CI2
DSASP
IBW
AWF
PIONIER
GEANT
USA
CI
GFKM
UG2ck
TASK
UG1
HAAMG
UG2
UG1
KKNJO
KDM
BVI
MIR
MM
BBC
DS2AM
UMSOPOT
UMSop
CKU
WSFiR
IŁ
IMGW
UG7SMuz
DS11PG
UG1CK
UG1fiz
UG1Fiz
UG2zarz
HAUG
UG14
ILO
UG2
UG3
WSM
UG3
RCSS
TPGda
Frankf urt 2.5GbpsPraga 2.5Gbps
PUW3PUW3
622 Mbps
10 Gbps
KOM
PARK
PPTT
WSM
PIT
AWF
DSWSM2
DSAMuz
KOM
IO
DSAWF
KWP
HOTAS
MM
PUW
PUW
CTO1
PROREM
CTO2
UG2
UG2ekon
WSM2
MIR2
WSM2
PIWDS
DS5PG DS2PG
IMP
PIW
UG2pr
POLPAK
UG11
UG1ck
KOSZALIN
OLSZTYN
KOSZALIN
TPSA
WP
AMG1
AMG1
UG2cen
UG2zarz
UG2ekB
UG2zarz
Project WDM at TASK
CWDM Passive optics: splitters, circulators Economy of our solution Future: 10GE, wideband circulator,
EPON
Our goal – multiply fiber strands for a new GE/10GE backbone and schools in access layer
Our pilot CWDM network
SPARE SPARE
GBIC
WEST EAST
1470 1510 1550 1590 1470 1510 1550 1590
MUX/DEMUX-4 MUX/DEMUX-4
ACC TASK
EAST
EAST
EAST
WEST
WEST
WEST
1470nm OADM
1510nm OADM
1550nm OADM Maritime Academy
Univ. of Gdansk
Univ. of Sopot 1470nm GBIC
1550nm GBIC
1510nm GBIC 1510nm GBIC
1470nm GBIC
1550nm GBIC
Passive CWDM
4,8,16 lambdas -
Difficult to integrate ATM&TDM with passive OADM -
Costs -
Support for 10GE ?
Second solution – passive optics
Idea of FBT coupler
Idea of Circulator
What is a FBT coupler ?
FBT - Fused Biconical Taper
FBT coupling ratio
Coupling ratio as a function of pull length for a fused biconical taper coupler made of identical fibres
Fiber optic circulator
A fiber optic circulator is a passive device which transports an optical signal from one port to the next
port, only in one direction (i.e. 1 to 2, or 2 to 3).
Single-fiber bidirectional link
TP3 TP2
Coupler Coupler
Tx2
Rx2 Rx1
Tx1 single fiber
Link reflections
Transceiver Near
(High Power P max )
Transceiver Far
(Low Power P min ) fiber
range L (km)
Reflection due to ODN (far end terminated)
P Rx-signal =P min x Channel Loss
P Rx-reflect =P max x Channel Loss 2
x ORL + P max x ODN
Reflection due ORL
Intenal reflection (outside spec scope)
Channel Loss: Feber attenuation (0.5dB/km x10km) Connector (0.5dBx4)
Link Penalty: MPN and others – 3dB allotment
ODN – Optical Distribution Network
TASK’s access link realization
POP CWDM
1310 bidirectional
coupler coupler End User
One fiber
using standard 50/50 wideband couplers
TASK’s access link realization
using standard 50/50 and WDM couplers and two bidirectional transmissions within a single fiber
One fiber1310/1550
User 1(1310nm)
User 2(1550nm)
1550
1310
1550
1310
1310/1550
1310
1550
1310/1550
bidirectional
WidebandCoupler
50/50
1310
1550
WDMCoupler
1310/1550
1310/1550
1310/1550WidebandCoupler
50/50
WDMCoupler
1310/1550
WDMCoupler
1310/1550
WDMCoupler
1310/1550
Our handmade FBT WDM
Comparison of costs CWDM & FBT
CWDM4 lambdas MUX/DEMUX 4 channel 2800
Coloured GBICs 160004700 €/line
FBT2 lines Access line 1
2 std. couplers + 2 GBICs 360 €/line
2 lines / 2 lambdas Access line 2User12 WDM couplers + 2 GBICs 540User22 WDM couplers + 2 GBICs 1550nm 28402 std. couplers 240
1810 €/line
EPON downstream
EPON upstream
Summary
Single fiber solutions based on passive optics multiply capacity of optics layer and are very cost attractive
Links
ACC TASKhttp://www.task.gda.pl
Ethernet in the First Mile IEEE802.3ah Study grouphttp://www.ieee802.org/3/efm/index.html
Thank YouThank You