target net zero - passive house...a passive house approach: basic systems to achieve market rate: 1....
TRANSCRIPT
![Page 1: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/1.jpg)
1
37 Hudson
Target Net Zero
Columbia City - Mixed Use Housing
Cascade Built & NK Architects
March 11th, 2016
![Page 2: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/2.jpg)
© 2016 Nicholson Kovalchick Architects
Outline
Where are we going?
A. Big Hairy Audacious Goal
B. Reality Check
C. What is Net Zero target?
D. Comments - Responses
![Page 3: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/3.jpg)
© 2016 Nicholson Kovalchick Architects
+ NK Architects
Passive House
Certified Projects:
Park Passive
View Haus 5
Mini-B backyard cottage
Built Using Passive
House Standards:
SolHaus
![Page 4: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/4.jpg)
© 2016 Nicholson Kovalchick Architects
Net Zero APARTMENTS in 4-stories:
Small Lot of 4900 square feet
35 small dwelling units averaging 400 SF
800 square foot corner retail
Solar PV array to achieve Net Zero annual ON-SITE performance
PROTOTYPE?
B.H.A.G. Opportunity (Big Hairy Audacious Goal)
![Page 5: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/5.jpg)
© 2016 Nicholson Kovalchick Architects
A Passive House approach:
Basic Systems to achieve Market Rate:
1. 2x6 wood stud + 3-inch Mineral Wool wrap
2. Sealed Sheathing for Airtightness
3. (8) Shared Energy Recovery Ventilators
4. Large Windows with Operable Shading
5. Cross Ventilation for Summer Cooling
Will this get the project to B.H.A.G?
![Page 6: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/6.jpg)
© 2016 Nicholson Kovalchick Architects
A few challenges:
1. SEDU’s = small footprint ------------- more people & stuff PSF
2. Open walks and stairs ------------- many entry doors
3. Cross ventilation ------------- less Treated Floor Area
4. Big west facing windows ------------- Few South Windows
5. Not the ideal orientation
![Page 7: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/7.jpg)
© 2016 Nicholson Kovalchick Architects
Building Plan - Upper Levels
![Page 8: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/8.jpg)
© 2016 Nicholson Kovalchick Architects
Building Plan - Ground Level
![Page 9: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/9.jpg)
© 2016 Nicholson Kovalchick Architects
Net Zero Strategy:
20 kWh/sf/yr
5 kWh/sf/yr
5 kWh/sf/yr
5 kWh/sf/yr
5 kWh/sf/yr
17 EUI
Building
Floor Area
1 sf
Production
4 sf
Use =
=
5 kWh/sf/yr
3.412 kbtu/kWh x
PV
Area
![Page 10: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/10.jpg)
© 2016 Nicholson Kovalchick Architects
Elevated PV for total lot coverage
5% slope for passive washing
Elevated for Fire Access
Exceeds Zoning Height Limit
Maximum PV array design
![Page 11: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/11.jpg)
© 2016 Nicholson Kovalchick Architects
Reality Check:
Land Use pushback on Height of PV Cap
Cost of Raised PV Structure
Fire Departmentt requires pathway on all sides
ELEVATED ARRAY:
72,000 kW array provides 18.0 kBtu/SF/year = 18 EUI
Meets the Passive House target of PHIUS+2015
ON-ROOF ARRAY:
48,000 kW array provides 12.0 kBtu/SF/year = 12 EUI
Not the Net Zero target intended!
![Page 12: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/12.jpg)
© 2016 Nicholson Kovalchick Architects
On-Roof Array:
ON-ROOF ARRAY:
48,000 kW array provides 12.0 kBtu/SF/year = 12 EUI
![Page 13: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/13.jpg)
© 2016 Nicholson Kovalchick Architects
On-Roof Array:
ON-ROOF ARRAY:
48,000 kW array provides 12.0 kBtu/SF/year = 12 EUI
![Page 14: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/14.jpg)
© 2016 Nicholson Kovalchick Architects
2000 watt Society 1998 Swiss global target of personal performance
A. 2,000 watts of energy flow per person – source energy
B. 12,000 watts of energy flow is US average today
if we use the 2000 watt Society as the benchmark, then
C. 1,470 kWhrs/year “SITE” energy per person
What if we apply this principal to 3700 S Hudson?
![Page 15: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/15.jpg)
© 2016 Nicholson Kovalchick Architects
Ventilation Strategy - 1 Distributed ERV’s
![Page 16: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/16.jpg)
© 2016 Nicholson Kovalchick Architects
Ventilation Strategy - 2 Distributed ERV’s
![Page 17: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/17.jpg)
© 2016 Nicholson Kovalchick Architects
Summer Shading Strategy
WINTER - pm
WINTER - am SUMMER - am
SUMMER - pm
![Page 18: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/18.jpg)
© 2016 Nicholson Kovalchick Architects
3700 S Hudson - as 2000 watt building
Operating as a 2000 watt building “IN THE FUTURE”
13,000 SF = 12 EUI
Initial PHPP:
5.11 kBtu / SF / year
(close but needs work!)
![Page 19: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/19.jpg)
© 2016 Nicholson Kovalchick Architects
The Brussels Experience
Exemplary Buildings Program
![Page 20: Target Net Zero - Passive House...A Passive House approach: Basic Systems to achieve Market Rate: 1. 2x6 wood stud + 3-inch Mineral Wool wrap 2. Sealed Sheathing for Airtightness 3](https://reader034.vdocuments.us/reader034/viewer/2022042117/5e95b24b4a89fc0d930ddefd/html5/thumbnails/20.jpg)
© 2016 Nicholson Kovalchick Architects
1
Thank you!