airtightness and insulation with solar study
TRANSCRIPT
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/2
015 1
7:2
5:4
5
Site Plan
21/01/15
Site Plan
1:500
ISN/AIR-JF-009
?
Existing Building Boundary:
Extension Building Boundary:
Arrows Indicating the Fall of Water:
Site Boundary Line:
Legend
North
00.00
04.62ExistingChapel
Fall to
Centre:
1:50
Proposed
Extension
00.00
04.62
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/2
015 1
7:3
8:3
1
Roof Plan
21/01/15
1:100
ISN/AIR-JF-001
?
Existing Building Boundary:
Extension Building Boundary:
Arrows Indicating the Fall of Water:
Legend
Roof Plan
North
UP Existing
Stairs
5080
43.25 m²465.5 SF
Reception161 H
9.81 m²105.6 SF
Male WC161 I
30.07 m²323.7 SF
Green Room158
18.79 m²202.3 SF
Changing Room161 E
5.23 m²56.3 SF
Costume Store154
5.95 m²64.0 SF
Costume Store155
5.32 m²57.2 SF
Costume Store156
5.74 m²61.7 SF
Costume Store157
8.95 m²96.3 SF
Female WC161 J
3.03 m²32.7 SF
Disabled WC161 K
13.01 m²140.0 SF
Glass Link161 G
5972
25285
15305
19670
2425
18430
13.44 m²144.6 SF
WC & Shower Room161 F
14.37 m²154.7 SF
Prop Store161 B
14.37 m²154.7 SF
Prop Store161 A
16.66 m²179.4 SF
Matrix Chair Store161 D
15.12 m²162.8 SF
Matrix Chair Store161 C
15.69 m²168.9 SF
Lobby?
17386
191.89 m²2065.5 SF
Room161 L
A-A
B-B
B-B
A-A
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/2
015 1
7:2
5:0
8
Ground Floor Plan
21/01/15
1:100
ISN/AIR-JF-004
?
Airtightness Boundary Line:
Insulation Boundary Line
Legend
00 Ground Level
0
Lower Ridge
7600
10 Chapel Ridge Level
11978
Link Roof Level
2775
00 Ground Level
0
10 Chapel Ridge Level
11978
Extension Flat Roof Level
4983
00 Ground Level
0
10 Chapel Ridge Level
11978
Extension Flat Roof Level
4983
Link Roof Level
2775
Chapel Flat Roof Level
4620
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/2
015 1
7:2
5:4
2
Elevations
21/01/15
West Elevation
South ElevationNorth Elevation
East Elevation
Existing Building:
Extension Building:
Legend
1:100
ISN/AIR-JF-006
?
00 Ground Level
0
01 Ground Floor
300
Chapel Flat Roof Level
4620
Chapel Eaves
7935
10 Chapel Ridge Level
11978
Eaves Detail
Ridge Detail
Stain Sill DetailExt. Wall Detail
Existing Slate
Existing Battens
150mmCompressed RockWool
60mm Calsitherm
Existing CutLimestone
60mm Calsitherm
Existing CutLimestone
Existing Slate
Existing Battens
150mmCompressed RockWool
60mm Calsitherm
Existing CutLimestone
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/20
15 1
7:38
:33
Existing Chapel Sections
21/01/15
Airtightness Boundary Line:
Insulation Boundary:
Legend
Section B-B
Section A-A
1:50
ISN/AIR-JF-002
?
00 Ground Level
0
Extension Flat Roof Level
4983
Ext. Wall Base Detail
215mm Conc.Retaining Wall
15mm Stucco
130mm GutexMultitherm
40mmBitumen
AluminiumParapet
20mm OSB
60mm Screed
Concrete Slab
160mm GutexThermofalt
130mm GutexThermofloor
60mm Screed
19mm OakFloor
00 Ground Level
0
01 Ground Floor
300
Extension Flat Roof Level
4983
Ext. Curtain Wall Sill Detail
Ext. Curtain Wall Head Detail
215mm Conc.Retaining Wall
15mm Stucco
130mm GutexMultitherm
40mmBitumen
AluminiumParapet
20mm OSB
60mm Screed
Concrete Slab
160mm GutexThermofalt
130mm GutexThermofloor
60mm Screed
19mm OakFloor
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/20
15 1
7:38
:33
Proposed Extension Sections
21/01/15
1:50
ISN/AIR-JF-003
?
Airtightness Boundary Line:
Insulation Boundary:
LegendSection B-B
Section A-A
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
21/0
4/20
15 1
5:35
:22
Sun Light Analysis / ShadowStudy
21/01/15
March 21st 09:00am March 21st 12:00pm March 21st 03:00pm March 21st 04:30pm
June 21st 09:00am June 21st 12:00pm June 21st 03:00pm June 21st 04:30pm
December 21st 09:00am December 21st 12:00pm December 21st 03:00pm December 21st 04:30pm
This shadow displays the shadow path of the sunat date & time intervals.
A shadow study is used to determine:
Where a proposed structure may interfere withsurrounding buildings daylight.
The most suitable placement and orientation of aproposed structure so that it will benefit from thesouth.
Where the building will benefit from naturaldaylight and show where artificial light may beneeded.
It also determines where you should put most ofyour glazing and where it will benefit from this.
With these characterisitcs in mind a sun lightanlysis will help determine the orientation of theglazing on your building and where you canmodify it towhere the glazing would yield themost fo the suns rays.
There are a line of trees indicated on the viewswhich show where trees are blocking daylightentering the extension building, there seems tobe no heritage or council protecting these treesallowing to us to uproot and replant these treeselse where to free up incoming daylight.
If the trees are to be kept from an aesthetic pointof view a clerestory can be added to the southfacing side to allow light to enter the building justlike in the illustration below.
1:500
ISN/AIR-JF-005
?
01
313 130
426
215 15
60
80
17
18
19
10
09
08
05
0403
21
16 14 11
13
15
02
281
460
50
60
80
17
18
19
10
09
02
08
20
11
14
12
1316
15
20mm OSB
Proclima Intello Membrane
50mm Service Cavity
12.5mm Gypsum Plaster Board
3mm Gypsum Skim Coat
Kingspan Alpha III Pedestal
Kingspan Alpha III Floor Panel
Intello Sealed with Orcon F Adhesive
60mm Screed
80mmGutex Thermofloor
Schuco Double Glazing
15mm Stucco
Primer
215mm Concrete Cast In-Situ
DPM
130mm Gutex Multitherm
Raft Foundation
Hardcore
Earth
Tongue & Groove Flooring10
09
08
07
06
05
04
03
02
01
19
18
17
16
15
14
13
12
11
20
Specifications
100x19mm Chamfered Skirting
240x50mm Timber
20mm Bitumen
45° Cut Timber Block
150mm Concrete Slab
160mm Gutex Thermoflat
Aluminium Parapet
19mm Suspended Ceiling
50mm C Stud
Intello Over Lap Orcon F Adhesived Joint
29
28
27
26
25
24
23
22
21
30
08
19
18
1416
02
05
04
02
08
12
13
15
313 15
11
50 130 215
16
09
12
13
27
23
01
24
30
01
28
05
150
19
150
25
26160
150
14
29
04
Fall 1:50
03
16
14
04
05 01
02
15
13
12
01 0230
313
50
20
130
215
15
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/2
015 1
7:2
5:4
3
Extension Details
21/01/15
Curtain Wall Base Detail External Wall Detail
1:5
ISN/AIR-JF-007
?
Curtain Wall Head Detail Eaves DetailExt. Wall Plan Detail
39
31
33
40
41
34
37
3203
37
04
05
35
30
36
29
38
20mm OSB
Proclima Intello Membrane
50mm Service Cavity
12.5mm Gypsum Plaster Board
3mm Gypsum Skim Coat
Kingspan Alpha III Pedestal
Kingspan Alpha III Floor Panel
Intello Sealed with Orcon F Adhesive
60mm Screed
80mm Gutex Thermofloor
Schuco Double Glazing
15mm Stucco
Primer
215mm Concrete Cast In-Situ
DPM
130mm Gutex Multitherm
Raft Foundation
Hardcore
Earth
Tongue & Groove Flooring10
09
08
07
06
05
04
03
02
01
19
18
17
16
15
14
13
12
11
20
Specifications
100x19mm Chamfered Skirting
240x50mm Timber
20mm Bitumen
45° Cut Timber Block
150mm Concrete Slab
160mm Gutex Thermoflat
Aluminium Parapet
19mm Suspended Ceiling
50mm C Stud
Intello Over Lap Orcon F Adhesived Joint
29
28
27
26
25
24
23
22
21
30
Wall Plate
60mm Calsitherm Climate Board
150mm Pitch Pine Rafter
Slate
Timber Batten
Timber Ceiling
Existing Lime Render
Timber Joist
Existing Cut Limestone
Existing Corbel
39
38
37
36
35
34
33
32
31
40
Existing Rain Water Gutter
Ridge Slate Capping
Existing Parquet Tiling
100mm Concrete
Limestone Sill
Stain Glass Frame
Stain Glass
Nordan Triple Glazed Window
150mm Compressed Rockwool49
48
47
46
45
44
43
42
41
50
49
02
2025
150
313 50 60 20 540 20
05
01
32
09
32
44
18
39
03
29
37
02
37
18 19
313 540 2050 60 20
43
33
36
34
35
15
38
42
49
18
18
44
32
09
43
02
04
04
05
29
37
37
15
39
32
3 50 60 20 175 20 60 133
43
29
15
60
60
100
32
32
45
39 37
46
47
05
04
02
37
48
03
313 50 60 20 540 20
SCALE (@ A1)
NUMBER
TITLE
PROJECT NUMBER
CLIENT
PROJECT
DRAWING NUMBER REV
DRAWN BY DATE
STATUS
Innovative ArchitecturalTechnology
Jonathan Flanagan
01
Jonathan Flanagan80 Gleann Rua,Renmore,Galway.
DESIGNERS ADDRESS
Air Continuity and Air Tightnessin Construction
Galway Mayo Institute ofTechnology
CONTACT DETAILS
Phone: 0830054478Email:[email protected]
G00262330
16/0
4/20
15 1
7:25
:43
Chapel Details
21/01/15
1:5
ISN/AIR-JF-008
?
Ridge Detail Stain Glass Sill Detail
Ext. Wall Base Detail
Eaves Detail
Int. Wall Detail